Physical Property Testing Instruments
Filter
Showing 9961–9990 of 12279 results
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 28,000 (FOB) |
| Acceleration Range | 30–400,000 m/s² |
| Test Axes | X, Y, Z orthogonal directions |
| Max Load Capacity | 200 kg |
| Sample Height Limit | 200–300 mm |
| Radial Installation Radius | 200–1000 mm |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Continuous Operation Time | 30–60 min |
| Compliance | MIL-STD-810F, MIL-STD-883C, GJB 150A, GJB 360B, GB/T 2423, IEC 60068-2-27 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 28,000 (FOB) |
| Acceleration Range | 30–200,000 m/s² |
| Test Directions | X, Y, Z orthogonal axes |
| Max Specimen Height | 200–300 mm |
| Specimen Mounting Radius | 200–1000 mm |
| Startup Time | ≤3–5 min |
| Continuous Operation Duration | 30–60 min |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Dimensions (L×W×H) | 924×910×1242 mm to 1953×470×993 mm |
| Weight | 1000–2300 kg |
| Compliance | MIL-STD-810F, MIL-STD-883C, MIL-STD-202F, GJB 150, GJB 360, GB/T 2423, IEC 60068-2-27 |
| Brand | JByq |
|---|---|
| Model | JB-9K |
| Origin | Shanghai, China |
| Chamber Dimensions (L×W×H) | 1000 × 1000 × 1000 mm |
| Temperature Range | 20–90 °C (±1 °C accuracy) |
| Exposure Duration | 1–9999 s (±1 s resolution) |
| Jet Pressure | 8–10 MPa |
| Nozzle Configuration | 4 German-sourced high-pressure nozzles, adjustable tilt angles (0°, 30°, 60°, 90°) |
| Heating Power | 9 kW |
| Compliance | DIN 55662, ISO 16925, GM9531P, PV1503, VOLVO VCS 1029 54719, DBL 7381, FLTM BO 160-04, AA-0136 |
| Brand | MOTIS |
|---|---|
| Model | STF |
| Standard Compliance | UL 910 / NFPA 262 |
| Chamber Construction | Stainless Steel (304) with Refractory Brick Lining |
| Observation Window | Dual-Layer Quartz Glass |
| Flame Propagation Monitoring | LED Indicator Strip System |
| Smoke Seal | 2 mm 304 Stainless Steel Water-Tight Trough |
| Exhaust Fan | 3 kW, 380 V / 50 Hz, Variable-Frequency Drive, ≥8000 m³/h Capacity |
| Burner | Dual-Orifice Copper Burner, Heat Output Adjustable from 5.3 MJ/min (UL 910 baseline) up to 100 MJ/min via Mass Flow Control |
| Ignition System | High-Voltage Spark Igniter (44 kV / 50 mA, Minimum Electrode Voltage 1.8 kVp) |
| Pressure Monitoring | Differential Pressure Sensor, Range 0–250 Pa, Accuracy ±0.5 Pa (System Accuracy ±2 Pa) |
| Temperature & Smoke Signal Acquisition | 1 Hz Sampling Rate, Linearized Photometric Smoke Density Detection |
| Gas Control | 316 Stainless Steel Mass Flow Controller, Propane Range 0–2.3 g/s, Accuracy ±1% FS (0.6–2.3 g/s), Repeatability ±0.5% FS, NIST-Traceable Calibration |
| Software | Integrated Test Management Platform with Real-Time Logging of Airflow Velocity, Chamber Temperature, Optical Density, and Fuel Consumption |
| Auxiliary Systems | Municipal Water Supply Interface, Methane Gas Delivery Subsystem, Overhead Hoist for Sample Handling |
| Sample Mounting | Stepped Access Platform with Integrated Support for Calcium Silicate Cover Boards |
| Thermal Insulation | High-Temperature Ceramic Fiber Blanket within 304 Stainless Enclosure |
| Application Domain | Horizontal Cable Tray Fire Propagation Testing per UL 910/NFPA 262 for Plenum-Rated Communications Cables |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | STM-IVB Intelligent Krebs Viscometer |
| Pricing | Available Upon Request |
| Power Supply | 220 V AC, 50 Hz |
| Rotor Speed | 200 rpm ± 0.5 rpm |
| Rotor Dimensions | 54 mm × 7.9 mm × 0.8 mm |
| Sample Container | Φ85 mm × 85 mm (H) |
| Measurement Range | 40.2–141.0 KU |
| Load Range | 32–1099 g |
| Viscosity Range (CP) | 27–5250 cP |
| Accuracy | ±2% of full scale |
| Repeatability | ±1% of full scale |
| Display | LCD showing real-time KU value, load (g), CP-equivalent viscosity, and ambient temperature |
| Dimensions (L×W×H) | 180 × 210 × 470 mm |
| Net Weight | 7 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | STM-IV Stormer Viscometer |
| Pricing | Available Upon Request |
| Power Supply | 220 V AC, 50 Hz |
| Impeller Dimensions | 54 mm × 7.9 mm × 0.8 mm |
| Sample Cup Dimensions | Ø85 mm × 85 mm |
| Measurement Range | 40.2–141.0 KU and 32–1099 g |
| Accuracy | ±2% of full scale |
| Repeatability | ±1% of full scale |
| Rotational Speed | 200 rpm ±0.5 rpm |
| Compliance Standards | ASTM D562, GB/T 9269–1988 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-160 |
| Hardness Test Method | Rockwell, Ball Indentation (HBT), Vickers Hardness (HVT) |
| Load Range (Major Load) | 1–250 kgf (9.8–2450 N) |
| Test Anvil | Ø80 mm, Removable |
| Max Specimen Height | 300 mm |
| Max Specimen Depth | 200 mm |
| Display | 7-inch Touchscreen Interface |
| Illumination | LED at Indentation Zone |
| Optional Feature | Motorized Z-axis (Duramin-160 Z) |
| Compliance | ASTM E18, ISO 6508, EN ISO 6508, JIS Z 2245 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-3000 |
| Hardness Test Method | Brinell |
| Load Range | 62.5–3000 kgf (612.9–29400 N) |
| Maximum Specimen Height | 190 mm |
| Maximum Specimen Depth | 220 mm |
| Indentation Evaluation | Handheld Zoom Camera with Auto-Measurement |
| Control System | Embedded PC with Touchscreen & Mouse Interface |
| Compliance | ASTM E10, ISO 6506-1, EN ISO 6506-1 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-4 |
| Instrument Type | Microhardness Tester |
| Load Ranges | 0.0098–19.6 N (10 gf–2 kgf) and 9.81–613.1 N (1 kgf–62.5 kgf) |
| Test Height Range | 0–200 mm (M1), 0–400 mm (M2) |
| Measurement Method | Eyepiece-based manual indentation evaluation |
| Turret | Motorized 6-position |
| Stage | Manual XY stage (90 mm × 90 mm travel, 25 mm × 25 mm scratch area), manual Z-axis with micrometer adjustment |
| Display | 8-inch touchscreen interface |
| Compliance | Designed to meet ASTM E384, ISO 6507-1, ISO 6506-1, and EN ISO 2039-1 requirements for micro- and macro-hardness testing |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-600 |
| Load Ranges | 1–250 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Automation Level | Semi-automatic with motorized 6-position turret |
| Z-axis Options | Manual (M) or Motorized (Z) |
| Max Specimen Height | 330 mm |
| Max Specimen Depth | 260 mm |
| Display | 15-inch color touchscreen |
| Force Measurement | Load cell-based |
| Illumination | Ring light with dark-field mode |
| Software Interface | Integrated embedded PC with touch/mouse operation |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-650 |
| Load Ranges | 1–250 kgf, 3–750 kgf, 5–3000 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Automation Level | Semi-Automatic & Fully Automatic |
| Max Specimen Height | 300 mm |
| Max Specimen Depth | 220 mm |
| Control Interface | 15″ Color LCD Touchscreen |
| Load Cell Technology | Yes |
| Motorized Indenter | Yes |
| Motorized XY Stage (AC variants) | 390 × 262 mm travel, 250 × 160 mm scratch area |
| Turret | 6-position (M) or 8-position (AC) motorized |
| Optical System | Panoramic overview camera + laser positioning + auto-focus + auto-illumination |
| Compliance | ASTM E384, ASTM E10, ASTM E18, ISO 6507, ISO 6506, ISO 6508, ISO 2039 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVersa-100 |
| Instrument Type | Universal Hardness Tester |
| Load Range Options | 200 gf–250 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Turret | Motorized 9-position |
| Automation Features | Motorized Z-axis with auto-focus, motorized XY-stage (optional), anti-collision system, panoramic camera, embedded PC with touch interface |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVigo-150 |
| Hardness Test Method | Rockwell & Superficial Rockwell |
| Load Range | 3–250 kgf (29.4–2452.5 N) |
| Frame Type | C-frame with reinforced steel construction |
| Depth Measurement System | Direct sub-micron axial displacement sensor |
| Display | 6.5-inch capacitive color touchscreen |
| Interface | USB port for data export |
| Compliance | ISO 6508-1, ASTM E18, EN ISO 2039-2 |
| Software Features | Statistical analysis, hardness conversion tables, upper/lower limit visualization (green/red), surface correction, GLP-compliant audit trail |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVista-40 |
| Hardness Test Methods | Vickers, Knoop, Brinell |
| Load Range | 0.1 gf to 62.5 kgf |
| Automation Level | Semi-Automatic and Fully Automatic Micro/Macro Testing |
| Software | DuraSoft PC Control Software |
| Display | 27" Full-HD Touchscreen |
| Turret | Motorized 6-Position |
| Stage | Manual and Motorized XY Stage Options |
| Z-Axis | Motorized with Auto-Focus and Collision Protection |
| Camera | 18 MP High-Resolution Measurement Camera |
| Optional | Panoramic Camera Module |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | MoviPol-5 |
| Power Source | Rechargeable Li-ion Battery (1.5 h continuous operation) |
| Application | On-site metallographic surface preparation |
| Technique | Electrochemical polishing & etching |
| Portability | Handheld, field-deployable unit |
| Surface Marking | Non-invasive, minimal surface alteration |
| Typical Use Cases | Weld inspection, pipeline integrity assessment, large-component joint analysis |
| Compliance | Designed for ISO 14823, ASTM E3, ASTM E407, and EN 1369-compliant metallographic workflows |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | PSM-5 / PSM-10 |
| Magnification | 100× (standard), up to 400× (PSM-5), up to 600× (PSM-10) |
| Objective Lenses | 10×, 20×, 40× (standard) |
| Eyepiece | 10× wide-field |
| Illumination | Battery-powered high-intensity LED |
| Optional Accessories | Digital camera module, measuring eyepiece, stage micrometer, magnetic cross-stage (PSM-10 only), high-tripod base for curved surfaces (PSM-10 only), aluminum transit case |
| Brand | Struers |
|---|---|
| Origin | France |
| Model | PSM-5 / PSM-10 |
| Magnification | up to 400× (PSM-5), up to 600× (PSM-10) |
| Illumination | Integrated battery-powered LED |
| Construction | Lightweight aluminum housing |
| Accessories | Digital camera adapter, eyepiece micrometer, thin-film thickness gauge, magnetic cross-stage (PSM-10 only), high tripod base (PSM-10 only) |
| Carrying case | Rugged aluminum transport case with integrated tool storage |
| Compliance | Designed for field-deployable non-destructive evaluation in accordance with aerospace surface inspection best practices |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | RepliSet |
| Pricing | Available Upon Request |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | TransPol-5 |
| Power Supply | Rechargeable Li-ion battery or AC adapter (100–240 V, 50/60 Hz) |
| Motor | High-torque brushless DC motor |
| Grinding/Polishing Plate Diameter | 32 mm |
| Cable Length | 3 m remote control cable |
| Weight | ≤ 4.5 kg |
| Dimensions (L×W×H) | 220 × 120 × 180 mm |
| Included Accessories | Battery pack, charger, transport case, consumables kit (grinding papers, polishing cloths, diamond suspension), remote control unit |
| Compliance | CE, RoHS, IP54 rated for dust and water resistance |
| Brand | Stuart |
|---|---|
| Origin | UK |
| Model | SMP10 |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 1 °C |
| Accuracy | ±1.0 °C at 20 °C, ±2.5 °C at 300 °C |
| Heating Rate | 20 °C/min (pre-heat), 2 °C/min (melting determination) |
| Display | 3-digit LED |
| Sensor | PT100 platinum resistance thermometer |
| Sample Capacity | 2 capillaries simultaneously |
| Dimensions (W×D×H) | 160 × 220 × 170 mm |
| Net Weight | 1.8 kg |
| Power Supply | 230 V / 50 Hz, 75 W |
| Includes | 100 sealed-end capillary tubes (SMP10 kit) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP30 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | 12 min |
| Heating Time (50 °C → 350 °C) | 6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Temperature Memory | 8 readings per sample |
| Display | 40×4 character LCD |
| Sensor | PT100 platinum resistance thermometer |
| Power Supply | 230 V, 50 Hz, 60 W |
| Dimensions (W×D×H) | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Capillary Storage Compartment | Integrated |
| Observation Chamber | Dual-height adjustable |
| Illumination | Integrated high-intensity LED lighting |
| Surface Finish | Biocote® antimicrobial coating |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP30 |
| Price Range | USD 1,400–2,800 |
| Sample Capacity | 3 capillaries |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.5–10.0 °C/min (0.1 °C increments) |
| Temperature Memory | 8 readings per sample |
| Sensor | PT100 platinum resistance thermometer |
| Cooling | Integrated air pump |
| Dimensions | 325 × 200 × 170 mm |
| Net Weight | 3.6 kg |
| Power Supply | 230 V, 50/60 Hz, 60 W |
| Standard Accessories | Glass capillary tubes (SMP10/1) |
| Brand | Stuart |
|---|---|
| Origin | United Kingdom |
| Model | SMP40 |
| Temperature Range | Ambient to 400 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 0.1–10 °C/min (adjustable in 0.1 °C increments) |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Sample Capacity | 3 capillaries simultaneously |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200 measurement records with embedded AVI video |
| Compliance | Pharmacopoeial standards (USP <741>, EP 2.2.14, JP 2.60), GLP-ready, includes traceable calibration certificate |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Power Supply | 230 V / 50 Hz / 60 W |
| Capillary Storage Compartment | Yes |
| Glass Tool Storage Compartment | Yes |
| Antimicrobial Surface Coating | Biocote® silver-ion technology |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMP40 |
| Price Range | USD 4,200–7,000 (est.) |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–10.0 °C/min (adjustable in 0.1 °C increments) |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Capillary Length | 100 mm |
| Sample Capacity | 3 samples simultaneously |
| Temperature Resolution | 0.1 °C |
| Cooling Time (350 °C → 50 °C) | ≤10 min |
| Heating Time (50 °C → 350 °C) | ≤6 min |
| Display | 5.7″ color VGA touchscreen |
| Sensor | PT100 platinum resistance thermometer |
| Data Storage | 200+ test records with full AVI video capture |
| Power Supply | 230 V / 50 Hz, 60 W |
| Dimensions (W×D×H) | 175 × 210 × 328 mm |
| Net Weight | 3.2 kg |
| Brand | SumSpring |
|---|---|
| Model | CNY-1 |
| Measurement Principle | Rolling Ball Method per FINAT Test Method No. 9 & GB/T 31125–2014 |
| Load Capacity Options | 20 N or 300 N (selectable) |
| Force Accuracy Class | Class 1 |
| Test Speed Range | 1–500 mm/min (standard operating speed: 300 mm/min) |
| Speed Accuracy | ±2% |
| Specimen Dimensions | 180 mm (L) × 25 mm (W) |
| Test Plate Dimensions | 25 mm × 72 mm × 3 mm (L × W × H) |
| Overall Dimensions | 310 mm × 400 mm × 560 mm (L × W × H) |
| Weight | 26 kg |
| Operating Environment | 23 ± 2 °C, RH ≤ 80% (non-condensing) |
| Power Supply | 220 V, 50 Hz |
| Compliance | FINAT TM9, GB/T 31125–2014 |
| Standard Configuration | Main Unit, Micro Thermal Printer, Fixture Set, Stainless Steel Test Plates |
| Brand | SumSpring |
|---|---|
| Model | CNY-1 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Initial Adhesion Tester (Rolling Ball Method) |
| Adjustable Incline Angle | 0–60° |
| Test Stations | 3 |
| Test Zone Width | 80 mm |
| Tabletop Width | 120 mm |
| Standard Steel Balls | 1/32″ to 1″ (0.794 mm to 25.4 mm) |
| Dimensions (L×W×H) | 430 × 160 × 170 mm |
| Weight | 7 kg |
| Operating Temperature | 15–50 °C |
| Relative Humidity | ≤80% RH, non-condensing |
| Compliance | GB/T 4852–2002, Chinese Pharmacopoeia 2015 & 2025 Editions |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DLJ-2000 |
| Drop Height Range | 300–1500 mm (customizable) |
| Max. Specimen Weight | 65 kg |
| Max. Specimen Dimensions | 800 × 800 × 800 mm (L×W×H) |
| Impact Platform Size | 1700 × 1200 × 14 mm (L×W×H) |
| Drop Height Accuracy | ±10 mm |
| Levelness Tolerance of Drop Surface | <2° |
| Overall Dimensions | 1700 × 1200 × 2300 mm (L×W×H) |
| Net Weight | 260 kg |
| Operating Temperature | 15–35 °C |
| Relative Humidity | ≤70% RH (non-condensing) |
| Power Supply | 380 V, 50 Hz |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electronic Tensile Testing Machine |
| Load Capacity Options | 50 N, 500 N, 1500 N, 2000 N (selectable) |
| Accuracy Class | Class 1 (per ISO 7500-1 / ASTM E4) |
| Test Speed Range | 1–500 mm/min, infinitely variable |
| Displacement Accuracy | ±2% |
| Test Width | 50 mm (custom fixtures available) |
| Maximum Travel | 650 mm |
| Dimensions (L×W×H) | 450 × 300 × 1350 mm |
| Weight | 78 kg |
| Operating Environment | 23 ± 2 °C, ≤80% RH (non-condensing) |
| Power Supply | 220 V, 50 Hz |
| Brand | SumSpring |
|---|---|
| Model | LT-3000 |
| Measurement Range | 20 N or 300 N (selectable) |
| Accuracy Class | Class 1 |
| Test Speed | 1–500 mm/min (standard setting: 300 mm/min) |
| Speed Accuracy | ±2% |
| Specimen Size | 180 mm (L) × 25 mm (W) |
| Test Plate Dimensions | 25 mm × 72 mm × 3 mm |
| Overall Dimensions | 310 mm × 400 mm × 560 mm (L×W×H) |
| Weight | 26 kg |
| Operating Environment | 23 ± 2 °C, RH ≤ 80% (non-condensing) |
| Power Supply | 220 V, 50 Hz |
| Compliant Standards | FINAT Test Method No. 9, GB/T 31125–2014 |