| Key | Brand: Yuelian |
|---|---|
| Model | YL-GQ-8000E |
| Internal Volume | 8000 L |
| Chamber Dimensions (W×D×H) | 200 × 200 × 200 cm |
| Temperature Range | −50 to +100 °C |
| Pressure Range | 10–101.3 kPa (abs) |
| Pressure Control Accuracy | ±2 kPa (10–40 kPa), ±5% (40–2 kPa), ±0.1 kPa (2–1 kPa) |
| Temp. Uniformity | ≤2.0 °C (at steady state, ambient pressure, unloaded) |
| Temp. Stability | ±0.5 °C |
| Temp. Resolution | 0.1 °C |
| Cooling Rate | 1 °C/min (25 → −50 °C, avg.) |
| Heating Rate | 3 °C/min (25 → +100 °C, avg.) |
| Pressure Ramp Rate | ≥10 kPa/min |
| Depressurization Time | ≤5 min (101.3 → 10 kPa at −50 °C) |
| Construction | Exterior – Reinforced cold-rolled steel with white epoxy coating |
| Safety Systems | Over-temperature, over-pressure, leakage current, overload, acoustic-optic alarm, explosion-proof design, smoke exhaust & filtration (optional) |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-H03C-SV |
| Display Type | Backlit LCD |
| Measurement Principle | Oscillating Electrometer (Electrostatic Induction) |
| Voltage Range (Standard Mode) | 10 V – 19.99 kV |
| Voltage Range (IB Mode) | 1 V – 1999 V |
| Resolution | 1 V (IB Mode), 10 V (Standard Mode) |
| Measurement Distance | 30 mm (fixed focal point via red LED alignment) |
| Sampling Rate | 2 Hz (0.5 s update interval) |
| Test Angle | 180° peel configuration |
| Peel Speed Control | 100–10,000 mm/min (adjustable via 5-inch touch interface) |
| Effective Travel | 500 mm |
| Specimen Width | 50 mm |
| Drive System | Delta servo motor + Delta servo driver |
| Transmission | Precision ball screw + linear guide rails |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 400 W |
| Operating Temperature | 0–40 °C |
| Dimensions (Tester Unit) | 68 × 22 × 138 mm (W×D×H) |
| Weight (Unit) | 230 g (incl. battery) |
| Dimensions (Main Frame) | 1363 × 420 × 850 mm (W×D×H) |
| Safety Features | Upper/lower voltage limits, specimen break detection, emergency stop logic |
| Compliance Notes | Designed for laboratory and production-line electrostatic process validation |
| Measurement Range | ±2 kV |
|---|---|
| Test Distance | 5 mm – 25 m |
| Sensing Area Diameter | 25–175 mm |
| Accuracy | ±5% of full scale |
| Resolution | 1 V |
| Operating Temp. | 15–35 °C, RH ≤85% non-condensing |
| Drift | <600 ppm/hour (time), <600 ppm/°C (temp.) |
| Response Time | <25 ms |
| Display | 3.5-digit LCD |
| Dimensions | 31 × 59 × 173 mm |
| Weight | 200 g |
| Power | 9 V battery (8 h continuous operation) |
| Analog Output | Yes |
| Hold Function | Yes |
| Sensor Thickness | Ultra-thin probe design |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-H60T |
| Max Operating Temperature | 200 °C |
| Temperature Range | RT to 200 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Deviation | ±1 °C |
| Heating Rate | ≤30 min (from RT to 200 °C) |
| Chamber Dimensions (W×H×D) | 1400 × 550 × 2000 mm |
| Test Capacity | 60 specimens (20 per tier, 3-tier vertical configuration) |
| Control System | PLC + HMI touchscreen interface |
| Display Resolution | 0.1 min (0–99999.9 min) |
| Load Application | Standard 1 kg stainless steel weights (304, ASTM-compliant mass tolerance) |
| Structural Material | Laser-cut & CNC-bent 304 stainless steel frame |
| Power Supply | 220 VAC, 50–60 Hz |
| Key | Brand: Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-JY-2T |
| Max. Crushing Force | 20 kN (2 metric tons) |
| Sample Chamber Dimensions | W300 × D300 mm |
| Stroke Range | 0–300 mm |
| Crushing Speed | 1–10 mm/s (adjustable) |
| Force Accuracy | ±0.5% of reading |
| Force Resolution | 1/500,000 FS |
| Displacement Resolution | 0.01 mm |
| Data Acquisition Rate | ≥30 Hz |
| Voltage Measurement Range | 0–36 V (±0.1% FS) |
| Temperature Measurement Range | 0–600 °C (±1 °C) |
| Control System | Servo Motor + PC-Based Software |
| Compliance | Designed for UN 38.3, GB/T 31485, IEC 62133, ISO 12405, and QC/T 743 test protocols |
| Key | Brand: Yuelian |
|---|---|
| Model | YL-JY-2T |
| Max Crushing Force | 20 kN (2 metric tons) |
| Max Sample Dimensions | 300 × 300 mm (W × D) |
| Stroke Range | 0–300 mm (adjustable) |
| Speed Range | 1–500 mm/min (programmable) |
| Force Accuracy | ±0.5% of reading |
| Force Resolution | 1/500,000 full scale |
| Displacement Accuracy | ±0.5% of reading |
| Displacement Resolution | 0.01 mm |
| Voltage Measurement | 0–36 V (±0.1% FS) |
| Temperature Measurement | 0–300 °C (±1 °C) |
| Data Acquisition Rate | ≥30 Hz |
| Compliance | Meets UN 38.3, IEC 62133, GB/T 31241, UL 1642, and ISO 12405 test requirements for mechanical abuse evaluation |
| Key Features | Max. crush force: 50 kN (5 T) |
|---|---|
| Sample chamber | W300 × D300 mm |
| Stroke range | 0–300 mm |
| Crush speed | 1–10 mm/s (adjustable, ±1 mm/s accuracy) |
| Force resolution | 1/500,000 FS |
| Force accuracy | ±0.5% of reading |
| Displacement resolution | 0.01 mm |
| Displacement accuracy | ±0.5% of reading |
| Data acquisition rate | ≥30 Hz |
| Voltage measurement | 0–36 V, ±0.1% FS |
| Temperature measurement | 0–600 °C, ±1 °C |
| Compliance | Designed per UN 38.3, GB/T 31485, IEC 62133, and ISO 12405 test protocols |
| Safety features | Dual-layer tempered explosion-proof observation window (350 × 400 mm), automatic pressure relief port, forced exhaust system, integrated LED lighting |
| Structural enclosure | Heavy-gauge cold-rolled steel (gray + blue epoxy finish) with stainless-steel interior |
| Key | Brand: Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-PW-2T |
| Max. Penetration Force | 20 kN (2 metric tons) |
| Needle Diameter Range | Φ5–Φ8 mm |
| Needle Tip Angle | 45°–60° |
| Penetration Speed | (25 ± 5) mm/s |
| Stroke Range | 0–300 mm |
| Positioning Accuracy | ±0.5% of full scale (force), ±0.5% of measured displacement |
| Force Resolution | 1/500,000 FS |
| Displacement Resolution | 0.01 mm |
| Data Acquisition Rate | ≥30 Hz |
| Voltage Monitoring Range | 0–36 V (±0.1% FS) |
| Temperature Monitoring Range | 0–600 °C (±1 °C) |
| Control System | Servo motor + PC-based software with real-time 5-channel (force, displacement, voltage, temperature, time) synchronized curve plotting |
| Safety Enclosure | Dual-layer tempered explosion-proof observation window (350 × 400 mm), forced exhaust, automatic pressure relief port, heavy-duty cold-rolled steel outer casing & stainless-steel inner chamber |
| Power Supply | AC220V/50Hz or AC380V/50Hz |
| Brand | Yuelian |
|---|---|
| Model | YL-RS-01 |
| Origin | Guangdong, China |
| Construction | Integrated chamber with cold-rolled steel outer shell and thickened stainless steel inner chamber |
| Internal Dimensions | W600 × D600 × H700 mm |
| External Dimensions | W1150 × D1100 × H1660 mm |
| Observation Window | 350 × 400 mm double-layer tempered blast-resistant glass |
| Flame Source | Bunsen burner (inner tube diameter 9.5 mm, length 100 mm) |
| Flame Height Adjustment Range | 10–75 mm (±5 mm accuracy) |
| Flame Application Time | 0–999.9 s (±0.1 s resolution) |
| Afterflame Time Measurement | 0–999.9 s (±0.1 s) |
| Test Orifice Diameter | 102 mm ± 2 mm |
| Steel Wire Mesh | 20 mesh, wire diameter 0.45 mm (aperture ≈ 800 µm per GB/T 6005-2008 R20) |
| Aluminum Enclosure Mesh | Octagonal, opposing sides 610 ± 10 mm, height 305 ± 5 mm, wire diameter 0.25 mm, 16–18 mesh (aperture ≈ 1.12 mm per GB/T 5330-2003 R20) |
| Ignition System | Automatic electronic ignition |
| Gas Supply | High-purity LPG (user-supplied) |
| Exhaust System | Forced-air exhaust with ducting interface |
| Pressure Relief | Integrated automatic pressure relief port |
| Control System | PLC-based HMI touchscreen interface |
| Power Supply | AC 220 V, 50 Hz |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YL-S70 |
| Price Range | USD 1,400 – 7,200 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N to 5 kN (dual-range configuration available) |
| Control Mode | Full PC-based closed-loop control |
| Force Resolution | 1/500,000 FS |
| Force Accuracy | Better than ±0.5% of full scale |
| Displacement Resolution | 1/500,000 mm |
| Sampling Rate | 50 Hz |
| Effective Stroke | 450 mm |
| Speed Range | 0.01–500 mm/min (customizable) |
| Test Space Width | 140 mm |
| Drive System | AC Servo Motor + Precision Ball Screw |
| Protection Features | Over-travel limit switch, overload cutoff, emergency stop, automatic fracture detection |
| Data Output Units | Force (N, kN, lbf, kgf), Displacement (mm, inch), Stress (MPa, Pa), Strain (%), and derived metrics (CPK, σ, median, trimmed mean, etc.) |
| Software Functions | Real-time multi-curve overlay (F–δ, F–t, δ–t, σ–ε), user-defined multi-step cyclic protocols, auto-return, auto-zero, bidirectional load cell polarity switching, 7 programmable test zones, 40 manual data points, 120 auto-sampled points |
| Included | USB/RS-232 interface cable, proprietary testing software, standard compression platens |
| Optional Accessories | Extensometers, custom fixtures (e.g., ASTM D3574 foam compression plates), dedicated PC workstation |
| Key | Brand: Yuelian |
|---|---|
| Model | YL-S70 |
| Max Test Load | 5 kN |
| Load Range | 10 N – 5 kN |
| Load Accuracy | Better than Class 0.5 |
| Travel Distance | 450 mm |
| Displacement Resolution | 1/500,000 mm |
| Drive System | AC Servo Motor + Precision Ball Screw |
| Control Mode | Full PC-Based Closed-Loop Control |
| Data Acquisition Rate | 50 Hz |
| Power Supply | 220 V, 50–60 Hz |
| Net Weight | 45 kg |
| Brand | Yuelian |
|---|---|
| Model | YL-S71 |
| Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N to 5 kN (dual-range configuration available) |
| Drive System | AC Servo Motor with Precision Ball Screw Transmission |
| Effective Travel | 700 mm |
| Speed Range | 0.01–500 mm/min (customizable) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | Better than ±0.5% of reading |
| Position Resolution | 1/500,000 mm |
| Data Acquisition Rate | 50 Hz |
| Test Space Width | 140 mm |
| Dimensions (W×D×H) | 520 × 590 × 1325 mm |
| Net Weight | 50 kg |
| Power Supply | 220 V, 50–60 Hz, 400 W |
| Compliance | Designed to support ASTM D882, D3330, D903, ISO 11339, ISO 8510-2, GB/T 2790–2792, and other standard methods for tensile, peel, and release force testing |
| Brand | Yuelian |
|---|---|
| Model | YL-S72 |
| Type | Electromechanical Universal Testing Machine |
| Drive System | AC Servo Motor with Precision Ball Screw Transmission |
| Max. Load Capacity | Up to 5 kN (configurable dual-range option available) |
| Effective Travel | 1000 mm |
| Test Speed Range | 0.01–500 mm/min (customizable) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | Better than Class 0.5 per ISO 7500-1 |
| Displacement Resolution | 1/500,000 mm |
| Data Acquisition Rate | 50 Hz |
| Power Supply | 220 V, 50–60 Hz |
| Net Weight | 55 kg |
| Dimensions (W×D×H) | 520 × 590 × 1530 mm |
| Compliance | ISO 7500-1, ASTM E4, ASTM D903, ASTM D3330, ISO 8510-2, GB/T 2790, GB/T 2791, GB/T 2792 |
| Key | Origin: Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Country of Origin | China |
| Model | YL-S90 |
| Max Test Force | 20 kN |
| Force Range | 20 kN (Full Scale) |
| Force Accuracy | ±0.5% FS |
| Travel Distance | 800 mm |
| Displacement Resolution | 1/500,000 mm |
| Drive System | Stepper Motor + Precision Ball Screw |
| Control Interface | PC-based via USB/RS-232 |
| Compliant Standards | GB/T 2792, ASTM D3330, GB/T 12914, GB 13022, GB/T 1040, GB/T 14344, GB/T 2191, QB/T 2171, GB/T 10003 |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-S90 |
| Maximum Test Load | 1 kN |
| Load Range | 100% FS |
| Load Accuracy | ±0.5% |
| Test Stroke | 450 mm |
| Displacement Resolution | 0.01 mm |
| Force Resolution | 1/120,000 full scale |
| Speed Range | 0.5–600 mm/min (computer-controlled) |
| Travel Width | 55 mm |
| Power Supply | 220 V, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 400 × 300 × 700 mm |
| Weight | ~28 kg |
| Interface | RS-232 |
| Compliance | ASTM D3330, ASTM D1000, ISO 29862, GB/T 2792, JIS Z 0237 |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-TB300AZK |
| Price | Upon Request |
| Control System | Self-developed Touchscreen HMI |
| Coating Methods | Interchangeable Doctor Blade & Wire Rod |
| Speed Range | 1–10 m/min (adjustable) |
| Stroke Length | 10–420 mm (adjustable) |
| Leveling Mechanism | Integrated Auto-Leveling System |
| Thickness Accuracy | ±0.003 mm |
| Coating Width | 300 × 450 mm |
| Wet Film Thickness Range | 0.005–5 mm |
| Temperature Range | Ambient to 160 °C (PID-controlled恒温) |
| Vacuum Adsorption | Yes |
| Wire Rod Length | 400 mm |
| Doctor Blade Material | Alloy Stainless Steel |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Power Consumption | 48 W |
| Dimensions (L×W×H) | 800 × 380 × 410 mm |
| Net Weight | 32 kg |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-UC200 |
| Price | Upon Request |
| Coating Head Type | Adjustable Comma Coater |
| Coating Thickness Range (Wet) | 1–60 mil (25–1,500 g/m²) |
| Adhesive Viscosity Range | 1,500–9,000 cP |
| Coating Width Adjustment | 12–300 mm (motorized or manual挡胶板 positioning) |
| Standard Web Width | 300 mm (custom widths available) |
| Coating Length | Unlimited (manual web draw-off) |
| Metering System | Digital Thickness Gauge (metric & imperial units) |
| Reservoir Capacity | 125 g |
| Max. Unwinding Roll OD | 300 mm |
| Dimensions (L×W×H) | 480 × 560 × 460 mm |
| Net Weight | 25 kg |
| Key | Brand: Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-WD100 |
| Contact Angle Range | 0–180° |
| Measurement Accuracy | ±0.1° |
| Measurement Methods | Sessile Drop, Insertion, Captive Bubble |
| Analysis Algorithms | Automatic Circle Fitting, Ellipse Fitting, Curved Surface Fitting, Height-Width Method, Tangent Method, Dynamic Sequence Analysis |
| Surface Energy Models | Fowkes, OWRK, Zisman, EOS |
| Stage Travel (X/Y/Z) | 100/100/50 mm (sample stage), 150 mm (fixed plate), 80 mm (microscope, ±3 mm fine adjustment) |
| Sample Max Size | 100 mm (W) × 80 mm (D) |
| Microscope | 2× Fixed-Magnification Optical System |
| Imaging | High-Resolution CMOS Camera with Video Capture, Frame-by-Frame Export, Real-Time Playback |
| Lighting | Adjustable Cold LED Backlight |
| Compliance Standards | GB/T 24368–2009, SY/T 5153–2007, ASTM D724–99(2003), ASTM D5946–2004, ISO 15989 |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | PGC Instruments, Inc. |
| Type | Upright Environmental Test Chamber |
| Capacity | 25 cu ft (708 L) |
| Temperature Range | 8–45°C |
| Temperature Uniformity | ±0.2°C |
| Temperature Accuracy | ±0.2°C |
| Relative Humidity Range | 20–83% RH |
| RH Uniformity | ±0.5% RH |
| RH Accuracy | ±1.0% RH |
| RH Uncertainty | ±0.5% RH |
| Power Supply | 115 V / 16 A / 60 Hz or 220 V / 12 A / 50 Hz (single-phase) |
| Construction | Corrosion-resistant stainless steel (interior & exterior) |
| Controller | SmartPad™ with real-time display, programmable alarms, and RS-232 serial output |
| Brand | York Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Smart Pad |
| Instrument Type | Upright |
| Humidity Control Method | Dew Point Generation System |
| Temperature & Humidity Uniformity | High Precision (±0.3°C, ±1.5% RH typical) |
| Controller | Smart Pad — 60-Stage Programmable, Real-Time Display, Standard Alarm Outputs & RS-485 Communication |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ATC 300A |
| Instrument Type | Bomb Calorimeter |
| Ignition Method | Cotton Thread & Ignition Wire |
| Temperature Resolution | 0.0001 °C |
| Test Mode | Isothermal |
| Test Duration | ≤15 min (Standard Method), ≤10 min (Rapid Method) |
| Calorific Value Range | ≤34,000 J |
| Heat Capacity Precision | ≤0.10% |
| Heat Capacity Drift | ≤0.20% |
| Oxygen Bomb Max Pressure | 240 bar |
| Bomb Material | Stainless Steel & Hastelloy (Corrosion-Resistant) |
| Data Storage Capacity | ≥10,000 Tests |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BAC-1000A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | RT to 300 °C (–25 °C with optional low-temp module) |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Needle Penetration Stroke | Programmable |
| Current Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | ≤0.5 °C |
| Temperature Control Range | RT to 300 °C |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Nail Penetration Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BAC-420B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Detection Threshold | < 0.02 °C/min |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420R |
| Measurement Mode | Adiabatic Calorimetry |
| Adiabatic Chamber Dimensions | 420 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module down to −25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–13°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <0.5°C |
| Max Sample Length | 600 mm |
| Compliance | GB/T 36276-2023, GB 38031-2020, SN/T 3078.1-2012, SAE J2464-2009, SAND2005-3123, UL 9540A-2019, SAND99-0497-1999 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Model | BAC-800A |
| Compliance | GB/T 36276–2023, UL 9540A, SAE J2464-R2009, ASTM E1981–98(2012), UL 1973, SN/T 3078.1–2012, SAND99-0497, FreedomCAR SAND 2005-3123 |
| Adiabatic Chamber Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Differential | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temperature module down to –25 °C) |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Puncture Stroke | Software-Configurable |
| Current Capacity of Charging/Discharging Electrode Posts | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-800B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Adiabatic Chamber Internal Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Difference | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temp module: –40 °C to 300 °C |
| Pressure Range | 0–2 MPa |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Nail Penetration Max Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-800R |
| Compliance | GB/T 36276-2023, GB 38031-2020, SAE J2464-2009, UL 9540A-2019, SN/T 3078.1-2012, SAND 2005-3123, SAND 99-0497-1999 |
| Adiabatic Chamber Dimensions | 800 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module: –25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–15°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <1°C |
| Maximum Sample Length | ≤600 mm |
| Safety Features | Pressure Relief Valve + Mechanical Interlock on Lid |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-90A |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | RT to 500 °C |
| Temperature Resolution | 0.001 °C |
| Chamber Dimensions | Ø90 mm × 110 mm depth |
| Temperature Tracking Rate | 0.005–40 °C/min |
| Minimum Detectable Temperature Rise Rate | 0.005–0.02 °C/min |
| Power Supply | 220 V / 50 Hz |
| Max Power Consumption | ≤3000 W |
| Data Interface | USB or RJ45 |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BIC-400A |
| Pricing | Upon Request |
| Automation | Fully Automated |
| Instrument Type | Isothermal Calorimeter |
| Measurement Principle | Power Compensation Isothermal Calorimetry |
| Temperature Range | −40 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Thermal Enthalpy Measurement Accuracy | ±1% (Power Compensation Mode) |
| Baseline Noise | 10 mW (Power Compensation), 0.2 mW (Heat Flow Mode) |
| Maximum Sample Dimensions | 345 mm × 230 mm × 100 mm |
| Max Compensation Power | 200 W |
| Sensitivity | 10 mW (Power Compensation), 0.2 mW (Heat Flow) |
| Temperature Stability | ±0.005 °C (Oil Bath Operation) |
| Oil Bath Temp Range | −40 °C to 200 °C |
| Heating Power | 3 kW |
| Cooling Capacity | 1.5 kW @ 20 °C, 1.5 kW @ 0 °C, 1 kW @ −20 °C, 0.3 kW @ −40 °C |
| Circulation Flow Rate | 22–26 L/min |
| Dual-Stage Pump Pressure | 0.4–0.7 bar (Heating/Cooling Loop), 0.2–0.4 bar (Suction) |
| Bath Opening/Volume | 12 × 11 / 16 cm, 5 L |
| Communication Interface | RS-232 (RJ45 adapter available) |
| Optional Battery Cycler | 4-channel, ±400 A / 0–5 V, ±0.1% FS voltage & current accuracy, SOC estimation support |