Physical Property Testing Instruments
Filter
Showing 2821–2850 of 12297 results
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCGEST-1600 |
| Quotation | Available Upon Request |
| Temperature Range | Ambient to 1650 °C |
| Heating Rate | 15 °C/min ±5 °C (adjustable) |
| Temperature Control Accuracy | ±2 °C |
| Atmosphere Control | Vacuum-compatible & gas-purged chamber (N₂, Ar, reducing/oxidizing options) |
| Sample Dimensions | Ø10 mm × 80 mm (cylindrical) |
| Sample Capacity | 1–4 parallel specimens (configurable) |
| Electrode Actuation | Motorized in-situ probe lift mechanism |
| Test Current Range | 10 μA to 10 A (9 discrete steps) |
| Resistivity Measurement Accuracy | ±0.5% of reading |
| Measurement Method | Four-Point Probe (van der Pauw compatible geometry) |
| Compliance Standard | GB/T 24523–2009 (Carbon Materials — Determination of Hot-State Electrical Resistivity) |
| Brand | Guance Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GEST-121A3 |
| Price | USD 1,550 (FOB Beijing) |
| Minimum Current Resolution | 1×10⁻¹⁶ A |
| Temperature Range | −40 °C to +250 °C |
| Heating/Cooling Rate | 0.5–10 °C/min |
| DC Voltage Ranges | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V |
| Electrode Diameter | 10 mm |
| Sample Stage | Motorized Vertical Positioning |
| Heating Method | Resistive Wire Heater (1500 W) |
| Cooling Method | Compressor-Based Refrigeration |
| Thermal Medium | Dimethyl Silicone Oil (2 cSt, 10 L capacity) |
| Data Acquisition | Real-time PC-controlled acquisition with dynamic curve visualization |
| Data Export | Excel-compatible .csv and PDF report generation |
| Weight | 100 kg |
| Brand | Guance Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-210.2 |
| Price | USD 1,420 (FOB Beijing) |
| Standards Compliance | YS/T 63.2–2006, GB/T 24525–2009, GB/T 24521–2018 |
| Measurement Principle | Four-Point Probe DC Resistivity Method with Current Reversal and Automated Contact Pressure Control |
| Brand | Guance Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GEST-210+ |
| Price | USD 1,420 (FOB Beijing) |
| Brand | Guance Instrument |
|---|---|
| Origin | Beijing, China |
| Model | PMLQ-500B |
| Drop Height | 460 mm (GB/ISO) / 500 mm (ASTM) |
| Steel Ball Diameter | 16 mm |
| Sample Dimensions | 100 × 100 × 50–100 mm |
| Rebound Accuracy | <1% |
| Sample Capacity | 3 specimens per test group |
| Height Detection | Automatic optical height sensing with dual verification (auto + manual scale reference) |
| Control System | Siemens PLC with 7-inch HMI touchscreen interface |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 560 × 360 × 860 mm |
| Weight | 25 kg |
| Compliance | GB/T 6670–2008, GB/T 10652–2001, ISO 8307, ASTM D3574 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZK-1895 |
| Price | USD 1,200 (FOB Beijing) |
| Application Field | General-purpose apparent density testing |
| Instrument Type | True Density Tester |
| Form Factor | Portable |
| Sample Type Support | Solid and Liquid |
| Density Measurement Range | 0–2 g/cm³ |
| Maximum Weighing Capacity | 20 g |
| Density Resolution | 0.1 g/cm³ |
| Display | Digital LCD |
| Operating Temperature Range | 0–40 °C |
| Repeatability | ±0.001 g/cm³ |
| Minimum Sample Volume | 1 mL (for liquids) / 1 g (for powders) |
| Funnel Outlet Diameter | 2.54 ± 0.16 cm |
| Funnel Top Diameter | 12.7 ± 1.0 cm |
| Funnel-to-Cup Vertical Gap | 3.8 cm |
| Cup Height | 24.0 ± 0.1 cm |
| Cup Internal Volume | 490 ± 2.0 mL |
| Funnel Angle | 24° |
| Construction Material | Stainless Steel (AISI 304) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BETA201A |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (BET & BJH) with Dynamic Preconditioning Capability |
| Analysis Stations | 1 |
| Surface Area Range | 0.0001 m²/g (Kr adsorption) to unlimited |
| Pressure Range | 0–133 kPa (0–1000 Torr) |
| P/P₀ Resolution | Up to 0.9995 |
| Vacuum Level | ≤1×10⁻⁸ Torr (with optional molecular pump) |
| Repeatability | <±1% (standard N₂ adsorption on certified reference materials) |
| Adsorption Gases | N₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Analysis Time | ~25 min per surface area measurement |
| Cryogen Capacity | 70 h continuous operation with standard 3.5 L liquid nitrogen Dewar |
| Isothermal Jacket | Integrated liquid nitrogen isothermal sleeve for thermal stability |
| Data Acquisition | 24-bit ADC |
| Compliance | Designed for GLP-compliant labs |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BETA201A.2 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (with Dynamic Mode Support) |
| Analysis Stations | 1 |
| Surface Area Range | 0.0001 m²/g (Kr adsorption) to unlimited |
| Pressure Range | 0–133 kPa |
| Repeatability | < ±1% (per ASTM D3663 and ISO 9277) |
| P/P₀ Resolution | Down to 1×10⁻⁷ |
| Vacuum Base Pressure | ≤1×10⁻⁸ Torr (with optional turbomolecular pump) |
| Adsorption Gases | N₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Analysis Time | ~25 min for surface area (N₂), ~3.5 h for full pore size distribution (N₂, 77 K) |
| Sample Temperature Control | Liquid nitrogen isothermal jacket with 70-h autonomous operation (optional auto-refill system) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BETA201A1 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (with optional dynamic mode support) |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | 0.0001 m²/g (using Kr adsorption) to unlimited |
| Pressure Range | 0–133 kPa (0–1000 Torr) |
| Theoretical Basis | Static Volumetric Gas Adsorption |
| Repeatability | ±0.001 m²/g (absolute) or <±1% relative |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BETA201A2 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Static Volumetric Method (with optional dynamic mode capability) |
| Number of Analysis Stations | 4 |
| Surface Area Range | 0.0001 m²/g (using Kr adsorption) to unlimited |
| Pressure Range | 0–133 kPa |
| Repeatability | ±1% (typical under controlled conditions) |
| Pore Size Range | 0.35 nm – 500 nm |
| Minimum Detectable Pore Volume | 0.0001 cm³/g (N₂ adsorption, with high-vacuum option) |
| Analysis Time | ~25 min per surface area measurement |
| Gas Compatibility | N₂, Ar, Kr, NH₃, CO₂, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Vacuum Base Pressure | ≤1×10⁻⁴ Torr (standard) |
| P/P₀ Resolution | up to 0.9995 |
| Detector | Imported capacitive absolute pressure transducer (0–10 Torr & 0–1000 Torr ranges), 0.1% full-scale accuracy, 24-bit ADC |
| Sample Tube Heating | Integrated in-situ degassing with dual-path valve isolation |
| Data Interface | USB or Ethernet (RJ45) |
| Software Language | Switchable Chinese/English UI & report output |
| Compliance | Designed for GLP-compliant environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | BETA202A |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Method (BET & DFT/NLDFT) |
| Analysis Stations | 1 dedicated station (optional dual-station configuration with 3 pressure transducers) |
| Surface Area Range | 0.0001 m²/g (using Kr adsorption) to unlimited |
| Pore Size Range | 0.35 nm – 500 nm |
| Pressure Range | 0–133 kPa (0–1000 Torr) |
| Repeatability | ±1% |
| Detection Limit for Pore Volume | 0.0001 cm³/g (N₂) |
| P/P₀ Resolution | down to 1×10⁻⁷ |
| Ultimate Vacuum | ≤1×10⁻⁸ Torr (with optional turbomolecular pump) |
| Thermal Control | Liquid nitrogen isothermal jacket + 70-hour Dewar capacity |
| Gas Compatibility | N₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Data Acquisition | 24-bit ADC, capacitive absolute pressure transducers (0.1% full-scale accuracy) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | BETA202A3 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Dynamic & Static Gas Adsorption (N₂, Ar, Kr, CO₂, etc.) |
| Analysis Stations | 100 (software-configurable multi-sample queue) |
| Surface Area Range | 0.0005 m²/g (Kr) to unlimited |
| Pore Diameter Range | 0.35 nm – 500 nm |
| Minimum Detectable Pore Volume | 0.0001 cm³/g (N₂) |
| Pressure Measurement Range | 0–10 Torr & 0–1000 Torr |
| Absolute Pressure Accuracy | ±0.1% FS (capacitive transducers, 24-bit ADC) |
| P/P₀ Resolution | up to 10⁻⁷ |
| Ultimate Vacuum | ≤1×10⁻⁸ Torr (with optional turbomolecular pump) |
| Repeatability | <±1% RSD |
| Analysis Time | ~25 min per BET surface area |
| Isotherm Points | Up to 1000 data points per run |
| Dewar Hold Time | 70 h (standard 3.5 L liquid N₂ dewar) |
| Gas Compatibility | N₂, Ar, Kr, CO₂, H₂, O₂, CH₄, C₄H₁₀, NH₃ (non-corrosive only) |
| Vacuum System | All-stainless-steel manifold with metal-sealed valves, silver-plated internal surfaces, dual-layer vacuum jacketing |
| Data Output | PDF/Excel export, bilingual (EN/CN) reporting, time-series comparative analysis, customizable test protocols |
| Compliance | Designed for GLP-compliant environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BETA202A4 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Gas Adsorption (BET, BJH, DFT, NLDFT, t-plot, αs-method) |
| Number of Analysis Stations | 10 |
| Specific Surface Area Range | 0.0005 m²/g (Kr) to unlimited |
| Pore Size Range | 0.35 nm – 500 nm |
| Pressure Range | 10⁻⁸ Torr – 1000 Torr |
| Relative Pressure (P/P₀) Resolution | Down to 10⁻⁷ |
| Repeatability | < ±1% (for N₂ at 77 K) |
| Detection Limit for Pore Volume | 0.0001 cm³/g |
| Vacuum System Base Pressure | ≤1×10⁻⁸ Torr (with optional turbomolecular pump) |
| Thermal Management | Integrated liquid nitrogen isothermal jacket with 70-hour autonomy |
| Gas Compatibility | N₂, Ar, Kr, CO₂, NH₃, H₂, CO, O₂, CH₄, C₄H₁₀ (non-corrosive only) |
| Data Acquisition | 24-bit ADC, dual-capacitance manometers (0–10 Torr & 0–1000 Torr), dedicated P₀ reference sensor |
| Connectivity | USB 2.0 or Ethernet (TCP/IP), remote control & multi-instrument management supported |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI.11 |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy Range | 0–100 J (pneumatically adjustable clamping force) |
| Maximum Impact Velocity | 5.5 m/s |
| Hammer Mass Options | 2–7 kg (standard configuration includes 5 kg, 15 kg, and 20 kg hammers) |
| Maximum Lift Height | 3000 mm |
| Effective Test Height | 1500 mm |
| Force Sensor Range | 0–100 J equivalent |
| Dimensions (L×W×H) | 1200 × 700 × 2100 mm |
| Weight | 300 kg |
| Automation Features | Motorized hammer lifting, automatic hammer latching/release, anti-reimpact safety mechanism |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CLC-AI2 |
| Instrument Type | Drop-Weight Impact Tester |
| Impact Energy Range | 0–100 J (standard) |
| Impact Velocity | 5.5 m/s (standard) |
| Hammer Mass Range | 2–7 kg |
| Force Sensor Range | 0–100 J (energy equivalent) |
| optional load cells | 10–250 kN |
| Maximum Lift Height | 2000 mm |
| Test Chamber Dimensions | 600 × 550 × 450 mm |
| Hammer Tip Diameters | Ø12, Ø12.5, Ø16, Ø20 mm (±0.1 mm) |
| Hammer Hardness | HRC 60–65 |
| Positioning Accuracy | ±1 mm |
| Dynamic Test Error | <2% |
| Data Acquisition Rate | 2 MHz |
| ADC Resolution | ≥16-bit |
| Force Sensor Sensitivity | 0.05–1 mV/lbf |
| Accelerometer Sensitivity | 2 pC/(m/s²) |
| Frequency Response (Accelerometer) | 1–12,000 Hz |
| Operating Temperature Range | –40°C to +150°C (optional environmental chamber) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (China) |
| Model | DW-1000A |
| Price Range | USD 1,550 – 7,000 (FOB) |
| Max Output Current | 1000 A AC |
| Temperature Channels | 2 independent acquisition + 1 closed-loop control |
| Control System | Siemens S7-1200 PLC + 15″ HMI touchscreen |
| Power Supply | 380 VAC ±10%, 50 Hz ±0.5 Hz, 20 kW |
| Ambient Operating Temp | −30 °C to +40 °C |
| Relative Humidity | ≤85 % RH |
| Altitude Limit | ≤1000 m |
| Enclosure Dimensions (L×W×H) | 1400 × 1150 × 1700 mm |
| Weight | 500 kg |
| Grounding Resistance | ≤4 Ω |
| Seismic Rating | Horizontal 3 m/s² / Vertical 1.5 m/s² |
| Safety Compliance | IEC 61000-4 (EMC), GB/T 16927.1–2011 (High-Voltage Test Techniques), GB 4793.1–2007 (Electrical Safety for Lab Equipment) |
| Brand | Guance Instruments |
|---|---|
| Model | DW-1000B |
| Max Output Current | 1000 A AC |
| Temperature Acquisition Channels | 2 (ambient + sample) |
| Temperature Control | 1 loop |
| Current Accuracy | ±1% FS |
| Power Supply | 380 VAC ±10%, 50 Hz ±0.5 Hz, 20 kW |
| Operating Ambient | –30–40 °C, ≤85% RH, ≤1000 m altitude |
| Enclosure Dimensions (L×W×H) | 1400 × 1150 × 1700 mm |
| Weight | 500 kg |
| Protection | Overcurrent, overtemperature, grounding (≤4 Ω), seismic rating (horizontal 3 m/s² / vertical 1.5 m/s²) |
| Control System | Siemens PLC + 15″ HMI touchscreen |
| Compliance | Designed per IEC 60950-1, GB/T 20641–2014 (low-voltage switchgear thermal testing), and general industrial safety requirements for high-current test environments |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (excl. tax & shipping) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 820 (FOB) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (excl. tax & shipping) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | FTDZ-I+ |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | FTDZ-I2 |
| Price | USD 2,500 (FOB Beijing) |
| Brand | Guance Instruments |
|---|---|
| Model | FTDZS-I |
| Measurement Principle | Four-Point Collinear Probe Method (Van der Pauw geometry compatible) |
| Resistivity Range | 10⁻⁵ – 10⁵ Ω·cm |
| Voltage Range | 2 mV – 2 V (4½-digit resolution, ±0.5% reading + 2 digits) |
| Current Sources | 1 μA – 100 mA (6 precision steps, ±0.5% reading + 2 digits) |
| Probe Spacing | 1.0 mm (tungsten carbide-tipped probes) |
| Sample Area | 3.142 cm² (20 mm diameter die) |
| Sample Mass Control | 2.501–2.5099 g (±0.005 g repeatability) |
| Electrode Loading | Dual-mode — manual pre-load + motorized servo-controlled compression (0–10 kN, integrated load cell) |
| Compliance Standards | YS/T 587.6–2006, GB/T 24525–2009, GB/T 30835–2014 |
| Interface | Touchscreen HMI with embedded data logging, USB export, and thermal printer support |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | FTDZS-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTJC-100 |
| Price | USD 1,750 (FOB Beijing) |
| Measurement Principle | Faraday Cup-based Triboelectric Charge Quantification |
| Charge Range | ±50.00000 µC / ±500.0000 nC |
| Resolution | 0.01 nC (10 pC) |
| Basic Accuracy | ±0.05% of Full Scale |
| Adjustable Filtering | 32-step digital low-pass filter |
| Sampling Rate | Up to 600 Hz (selectable: 5/10/20/50/100/200/400/600 Hz) |
| Interface | RS-232 with included PC cable and proprietary data acquisition software |
| Environmental Control | Integrated temperature & relative humidity monitoring |
| System Architecture | Modular, fully enclosed Faraday cage design compliant with IEC 61340-2-3 and ASTM D257 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTYS-10 |
| Instrument Type | True Density Tester |
| Form Factor | Portable |
| Sample Type Compatibility | Solid Powders & Liquids |
| Density Measurement Range | 0–10 g/cm³ |
| Maximum Load Capacity | 10 kgf |
| Density Accuracy | ±3% |
| Display | Digital LCD (7-inch Touchscreen) |
| Temperature Range | 20–50 °C |
| Humidity Range | 20–98% RH |
| Repeatability | ±0.1% |
| Resolution | 0.01 g/cm³ |
| Minimum Sample Mass | 0.1 g |
| Compliance Standard | GB/T 24533–2009 (Lithium-ion Battery Graphite Anode Materials — Test Method for Powder Compaction Density) |