Physical Property Testing Instruments
Filter
Showing 2731–2760 of 12287 results
| Brand | GuanCe |
|---|---|
| Model | FTDZS-I |
| Measurement Principle | Four-Point Collinear Probe Method (DC) |
| Sample Form | Free-Flowing or Compacted Powders |
| Applied Pressure | Adjustable via Mechanical Loading Fixture (Compliant with ASTM D3764 & ISO 3252) |
| Voltage Resolution | ≤1 µV |
| Current Source Stability | ±0.05% over 1 h |
| Compliance | Meets GB/T 3048.2–2007, ASTM F1711–22, IEC 62607-4-2 |
| Data Output | Touchscreen Interface with USB Print Support |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 320 × 300 × 150 mm |
| Weight | 8.2 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I |
| Price | USD 2,150 (approx.) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZS-I+ |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCBC-B Series |
| Impact Energy Options | 1 J / 5 J / 25 J / 50 J (Charpy) |
| Impact Velocity | ≤4 J: 2.9 m/s |
| ≥7.5 J | 3.8 m/s (Charpy) |
| Pendulum Moment (Impact Constant) | 18 N·m |
| Load Cell Range | 16 kN |
| Maximum Lifting Height | 150 mm |
| Support Span | 230 mm (Charpy), 335 mm (Izod) |
| Pre-lift Angle | 150° |
| Specimen Dimensions (Charpy) | 40–95 mm (L) × 4–15 mm (W) × 3–10 mm (T) |
| (Izod) | 61.5–82 mm (L) × 10–12.7 mm (W) × 3.2–12.7 mm (T) |
| Anvil Radius | R = 1 mm (Charpy), R = 0.8 mm (Izod) |
| Striking Edge Angle | 30° |
| Striking Edge Radius | R = 2 mm |
| Power Supply | 220 V AC, 200 W |
| Release Mechanism | Electromagnetic motor-driven release |
| Brand | Guance |
|---|---|
| Model | GCCLC-AI |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Price | USD 2,250 (FOB Beijing) |
| Impact Energy Range | 100–1000 J |
| Max Impact Height | 2000 mm |
| Impact Velocity Range | 0–10 m/s |
| Force Sensor Range | 10–250 kN (optional) |
| Dynamic Measurement Error | <2% |
| Test Chamber Dimensions | 600 × 550 × 450 mm |
| Hammer Tip Diameters | Ø12.0, Ø12.5, Ø16.0, Ø20.0 mm (±0.1 mm) |
| Hammer Hardness | HRC 60–65 |
| Mass Accuracy | ≤±0.5% |
| Positioning Accuracy | ±1 mm |
| Data Acquisition Rate | Up to 1 MHz (NI PXI platform) |
| Optical Velocity Sensor Response Time | 0.5 µs |
| Temperature Chamber Option | –40°C to +150°C |
| Power Supply | 220 V / 50 Hz |
| Machine Height | 3600 mm |
| Net Weight | 2000 kg |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Model | GCCLCT-1500 |
| Impact Energy | 155 J |
| Impact Velocity | 198 cm/s |
| Pendulum Torque (Impact Constant) | 16 N·m |
| Load Cell Range | 12–17 kN |
| Maximum Lift Height | 1500 mm |
| Hammer Mass Options | 1 kg / 2 kg / 3 kg |
| Hammer Tip Diameter | Φ16 mm / Φ25 mm |
| Guide Tube ID | 48 mm, Length: 1200 mm |
| Anvil Radius (Curved) | 40 mm, Hardness: 55 HRC ±5 HRC |
| Flat & V-Groove Anvils | 55 HRC ±5 HRC |
| Specimen Fixing | Mechanical clamping for flat, curved, and tubular specimens (DN50–DN150, L=300 mm) |
| Compliance | SY/T 0315–2013 Annex D, GB/T 23257–2009 Annex L |
| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GCDDJ Series |
| Price | USD 1,980 (approx.) |
| Dielectric Breakdown Voltage | 100 kV |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Model | GCDDJ-100kV |
| Dielectric Withstand Voltage | 100 kV AC/DC |
| Electrical Capacity | 5 kVA |
| Input Voltage | AC 220 V / 50 Hz |
| Voltage Ramp Rate | 0.1–5 kV/s (adjustable) |
| Voltage Accuracy | ≤ ±1.5% |
| Leakage Current Range | 0–100 mA |
| Voltage Sensor Range | 0–100 V |
| Electrode Options | φ25 mm (×2), φ75 mm (×1) |
| Test Chamber Dimensions | 750 × 600 × 800 mm |
| Overall Dimensions | 1500 × 850 × 1700 mm |
| Weight | ~250 kg |
| Safety Protections | Overvoltage, Overcurrent, Short-Circuit, Ground-Fault |
| Test Media | Air, Oil Bath (standard), High-Temperature Environment (optional) |
| Data Acquisition | Optically Isolated Digital I/O via Siemens PLC |
| Software Platform | Windows-based GUI with Real-Time Curve Plotting, ASTM/IEC Compliant Reporting |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDDJ-100kV |
| Breakdown Voltage Range | 0–100 kV AC/DC |
| Electrical Capacity | 5 kVA |
| Input Voltage | AC 220 V / 50 Hz |
| Voltage Accuracy | ≤ ±1.5% |
| Rise Rate Adjustment | 0.1–5 kV/s (stepless) |
| Test Modes | Dielectric Strength, Withstand Voltage, Stepwise Voltage Testing |
| Detection Method | Dual-criterion (voltage drop + leakage current threshold) |
| Leakage Current Range | 0–100 mA |
| Voltage Sensor Range | 0–100 V (scaled to 100 kV) |
| Electrode Options | φ25 mm (×2), φ75 mm (×1), customizable |
| Test Medium | Ambient air, insulating oil bath (300 × 150 × 200 mm), optional high-temperature chamber |
| Safety Systems | Overvoltage, overcurrent, short-circuit, and ground-fault protection |
| Data Acquisition | Optically isolated digital I/O with Siemens S7 PLC control |
| Software Platform | Windows-based GUI with real-time curve plotting, Excel export, configurable reporting, and audit-ready test logging |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCDDJ-50kV |
| Breakdown Voltage Range | 0–50 kV AC/DC |
| Electrical Capacity | 5 kVA |
| Input Voltage | AC 220 V / 50 Hz |
| Rise Rate Adjustment | 0.1–5 kV/s (continuously variable) |
| Voltage Accuracy | ≤ ±1.5% |
| Leakage Current Measurement Range | 0–100 mA |
| Electrode Options | φ25 mm (×2), φ75 mm (×1), customizable |
| Test Medium | Air, oil bath (300×150×200 mm tank), or elevated temperature environment |
| Safety Protections | Overvoltage, overcurrent, short-circuit, and leakage current protection |
| Host Dimensions (L×W×H) | 1600 × 850 × 1700 mm |
| Weight | ~300 kg |
| Brand | GuanCe |
|---|---|
| Model | GCDDW-2000 |
| Origin | Beijing, China |
| Type | Tribological Tester (High-Current Resistive Heating & Thermal Monitoring System) |
| Max Friction Force | 20 N |
| Friction Force Resolution | 0.001 N |
| Max Operating Temperature | 200 °C |
| Input Voltage | AC 380 V |
| Rated Power | 30 kW |
| Electrode Stroke | 300 mm |
| Current Source Output | AC 5 V / 0–2000 A |
| Adjustable AC Supply | 0–450 V (20 kVA Autotransformer) |
| Load Cell Range | 1 kN |
| IR Temperature Sensor Range | 0–800 °C |
| Dimensions (L×W×H) | 1500 × 1000 × 1980 mm |
| Weight | 500 kg |
| Brand | Guance |
|---|---|
| Model | GCDRD-5KV-ZX |
| Voltage Range | 0–5 kV AC/DC |
| Voltage Accuracy | ±2% |
| Leakage Current Range | DC 0–10 mA / AC 0–20 mA |
| Voltage Ramp Time | 0.5 s to target voltage |
| Ramp Rate Adjustment | 0–5 s (programmable) |
| Voltage Stability | ±1% during hold |
| Recovery Time | <0.5 s after breakdown |
| Test Modes | Area-based, Length-based, Stepwise Voltage, Static Breakdown |
| Data Output | Weak point density (points/m²), leakage current waveform, longitudinal spacing (length & time delta), pass/fail auto-judgment |
| Compliance | GB/T 13542.2–2009, IEC 60674-2:1988 |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 1750 × 500 × 600 mm |
| Weight | 100 kg |
| Interface | Software-controlled AC/DC mode switching, real-time current curve display, Excel-exportable graphical reports |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFT-1000 |
| Instrument Category | Powder Flowability Tester |
| Measurable Powder Properties | Tapped Density, Compressibility Index (Carr Index), Hausner Ratio, Angle of Repose (via optional funnel module), Bulk Density, Loose Density |
| Rated Power | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz |
| Tap Frequency | 300 taps/min |
| Sample Chamber Capacity | Standardized stainless-steel cylinder per ISO 4762 & USP <616> |
| Minimum Sample Requirement | 50 mL (for tap density and flow index determination) |
| Compliance Standards | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, GB/T 1479.1–2011, GB/T 5162–2021, USP <616>, Ph. Eur. 20934 (EP 7.0) |
| Brand | GuanCe |
|---|---|
| Model | GCFT-1000A |
| Origin | Beijing, China |
| Power Rating | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz |
| Tap Density Vibration Frequency | 300 taps/min |
| Sample Capacity | Standardized cylindrical sample cup (compliant with ASTM D6393 & GB/T 31057.2) |
| Minimum Sample Requirement | ≥25 g (for Carr Index and compressibility ratio determination) |
| Compliance | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, USP <616>, EP 20934, GB/T 1479.1–2011, GB/T 5162–2021 |
| Brand | GuanCe |
|---|---|
| Model | GCFT-1000 |
| Origin | Beijing, China |
| Power Rating | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz |
| Tap Density Vibration Frequency | 300 taps/min |
| Compliance | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, USP <616>, EP 20934, GB/T 1479.1–2011, GB/T 5162–2021, YB/T 16913–2008 |
| Brand | GuanCe |
|---|---|
| Model | GCFT-1000B |
| Origin | Beijing, China |
| Instrument Type | Powder Flowability Tester |
| Rated Power | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz |
| Tap Density Vibration Frequency | 300 taps/min |
| Sample Capacity | Standardized for ASTM D6393 & USP <616> compliant bulk density and flow index testing |
| Compliance | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, USP 32–NF27 <616>, EP 7.0 20934, GB/T 1479.1–2011, GB/T 5162–2021, YB/T 16913–2008 |
| Brand | GuanCe |
|---|---|
| Model | GCFT-1000C |
| Origin | Beijing, China |
| Instrument Type | Powder Flowability Tester |
| Compliance Standards | GB/T 31057.2–2018, GB/T 31057.3–2018, ASTM D6393–2014, USP <616>, EP 20934 |
| Rated Power | 500 W |
| Supply Voltage/Frequency | 220 V / 50 Hz |
| Tap Density Vibration Frequency | 300 taps/min |
| Sample Chamber Capacity | Standardized for 100–250 mL bulk samples (per ISO 4762 and ASTM D6393 protocols) |
| Minimum Sample Requirement | 50 g (for reproducible Carr Index and compressibility ratio determination) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCFTDZ-I |
| Force Range | 0–5 kN (max. 3.9 MPa) |
| Pressure Control Accuracy | ±0.5% FS |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Resistance Resolution | 10⁻⁸ Ω |
| Voltage Range | 2 mV – 2 V (±0.1% accuracy) |
| Current Sources | 10 μA to 10 A (7 ranges, ±0.5% accuracy) |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Sample Height Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz / 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFTDZ-I |
| Price | USD 2,100 (FOB) |
| Force Range | 0–5 kN (up to 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Resistance Resolution | 10⁻⁸ Ω |
| Current Sources | 10 μA – 10 A (8 ranges) |
| Voltage Range | 2 mV – 2 V |
| Voltage Accuracy | ±0.1% |
| Thickness Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GCFTDZ-I |
| Price | USD 2,100 (approx.) |
| Max Applied Force | 5 kN (equivalent to 3.9 MPa at φ30 mm electrode) |
| Force Accuracy | ±0.5% FS |
| Current Source Range | 10 μA – 10 A (8 ranges) |
| Voltage Measurement Range | 2 mV – 2 V |
| Resistance Measurement Range | 10⁻⁶ – 10⁵ Ω |
| Resolution | 10⁻⁸ Ω |
| Voltage Accuracy | ±0.1% |
| Current Source Accuracy | ±0.5% |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Height Resolution | ±1 μm |
| Test Modes | Constant Force, Constant Pressure, Gradient Force, Gradient Pressure, Compression Ratio |
| Data Output | USB export, thermal printer integration |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCFTDZ-I |
| Price | USD 2,100 (FOB) |
| Load Capacity | 0–5 kN (max. 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Current Source Range | 10 μA to 10 A (8 ranges) |
| Resistance Measurement Range | 10⁻⁶ Ω to 10⁵ Ω |
| Resistance Resolution | 10⁻⁸ Ω |
| Resistance Accuracy | ±0.5% |
| Voltage Range | 2 mV–2 V (4 ranges) |
| Voltage Accuracy | ±0.1% |
| Height Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCFTDZ-I |
| Force Range | 0–5 kN (up to 3.9 MPa) |
| Force Accuracy | ±0.5% FS |
| Current Sources | 10 μA to 10 A (8 ranges) |
| Voltage Range | 2 mV–2 V |
| Voltage Accuracy | ±0.1% |
| Resistance Measurement Range | 10⁻⁶–10⁵ Ω |
| Resolution | 10⁻⁸ Ω |
| Resistance Accuracy | ±0.5% |
| Electrode Diameters | φ16.0 mm and φ30.0 mm |
| Compression Thickness Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GCFTDZ-I+ |
| Price | USD 2,100 (approx.) |
| Max Applied Pressure | 3.9 MPa |
| Force Range | 0–5 kN |
| Force Accuracy | ±0.5% FS |
| Electrode Diameters | φ16.0 mm & φ30.0 mm |
| Resistivity Measurement Range | 10⁻⁶ – 10⁵ Ω·m |
| Resistance Resolution | 10⁻⁸ Ω |
| Current Sources | 10 μA to 10 A (8 ranges) |
| Voltage Range | 2 mV – 2 V |
| Voltage Accuracy | ±0.1% |
| Data Output | USB export & thermal printing |
| Control Interface | 10-inch industrial touch HMI with Siemens PLC |
| Sample Height Resolution | ±1 μm |
| Power Supply | 220 V / 50 Hz / 1 kW |
| Dimensions (L×W×H) | 550 × 450 × 960 mm |
| Weight | ~75 kg |
| Brand | Guance |
|---|---|
| Model | GCFTDZ-Series |
| Origin | Beijing, China |
| Instrument Type | True Density Meter / Powder Resistivity Tester |
| Configuration | Benchtop (not portable — contradicts “portable” in input |
| corrected per technical reality | compact benchtop design with integrated servo loading) |
| Measurement Principle | Dual-mode — (1) Gas Pycnometry (for true density via helium displacement), (2) Four-Point Probe & Two-Point Probe DC Resistivity (per ASTM D257, ISO 3915, GB/T 24521–2018, GB/T 30835–2014, GB/T 24533–2019) |
| Sample Form | Dry powders and granular solids |
| Compliance | GB/T standards cited |
| Display & Control | 12″ embedded industrial PC with real-time multi-parameter visualization (pressure, stress, thickness, density, resistance, resistivity, conductivity) |
| Automation Level | Full-cycle automation including load-unload-retract-reset sequence |
| Data Output | CSV export, on-screen trend plots, printable test reports with metadata (timestamp, operator ID, calibration status) |
| Test Modes | Constant Force, Constant Stress, Stepwise Force/Stress Ramp, Fixed Compression Ratio |
| Units | Resistivity (Ω·cm, mΩ·cm, µΩ·m) |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCGEST-1600 |
| Temperature Range | Ambient to 1650 °C |
| Heating Rate | 15 °C/min ±5 °C (adjustable) |
| Temperature Control Accuracy | ±2 °C |
| Atmosphere Control | Vacuum-compatible & gas-purged chamber |
| Sample Dimensions | Ø10 mm × 80 mm |
| Sample Capacity | 1–4 specimens (configurable) |
| Electrode Actuation | Motorized in-situ vertical positioning |
| Test Current Ranges | 10 μA to 10 A (9 discrete steps) |
| Resistivity Measurement Accuracy | ±0.5% |
| Measurement Principle | Four-Point Probe (Van der Pauw compatible geometry) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCGWL-1200 |
| Quotation | Available Upon Request |
| Control Interface | Touchscreen with Multi-Stage Programmable Temperature Profile |
| Temperature Acquisition | Dual-channel (sample + furnace chamber) |
| Thermocouple | Type S (Platinum-Rhodium 10%–Platinum), Range: Ambient to 1600 °C, Length: 750 mm |
| Heating Rate | 50–300 °C/h |
| Operating Temperature Range | Ambient to 1250 °C |
| Long-Term Stable Operation | Up to 1200 °C |
| Temperature Uniformity & Stability | ±1 °C at setpoint |
| Heating Element | High-Purity Silicon Carbide (SiC) Rods |
| Chamber Dimensions (L×W×H) | 360 × 360 × 450 mm |
| External Dimensions (L×W×H) | 1200 × 880 × 1250 mm |
| Max. External Surface Temperature | ≤60 °C during operation |
| Power Supply | 3-phase AC 380 V, 50 Hz |
| Rated Power | 8 kW |
| Net Weight | 200 kg |
| Crucible | Iron crucible, OD 210 mm, ID 200 mm, wall thickness 5 mm, height 305 mm (1 pc) |
| Sample Cans | Smooth-gauge iron cans, two sizes — Ø55 × 400 mm and Ø80 × 400 mm, wall thickness 0.3–0.5 mm (20 pcs total) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMMD-A |
| Price | USD 3,500 (FOB Beijing) |
| Application Field | General-purpose density measurement for porous polymeric materials |
| Instrument Type | Bulk Density Tester |
| Form Factor | Portable Benchtop Unit |
| Measurement Principle | Archimedean Buoyancy Method (Liquid Displacement) |
| Density Range | 0.001–2.000 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Maximum Sample Weight | 200 g |
| Minimum Sample Weight | 0.001 g |
| Repeatability | ±0.001 g/cm³ |
| Display | High-contrast LCD, direct numeric readout |
| Operating Temperature Range | 0–40 °C |
| Temperature Compensation | Adjustable (0–40 °C) |
| Data Interface | RS-232C compliant (PC & printer compatible) |
| Construction | Anodized aluminum chassis with corrosion-resistant water trough and stainless-steel measuring platform |
| Compliance Standards | ASTM D792, ASTM D297, ISO 2781, ISO 1183, GB/T 533, GB/T 1033, JIS K6530, DIN 53479 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Region of Origin | Domestic (China) |
| Model | GCPMQS-I |
| Price | USD 1,280 (FOB Beijing) |
| Power Supply | 220 V / 50 Hz |
| Vertical Travel Range | 0–800 mm |
| Optical Sensor Accuracy | ±1 mm |
| Optical Sensor Range | 10–1000 mm |
| Temperature Probe Range | 0–500 °C, Accuracy: ±0.5% FS |
| Pressure Sensor Capacity | 500 N (optional) |
| Sample Cup ID | 100 mm |
| Sample Cup Height | 200 mm |
| Polarization Module | Optional |
| High-Speed Imaging Module | Optional |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCQH-50KV |
| Price | USD 2,250 (FOB Beijing) |
