| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Rotating Disc Electrode (RDE) Atomic Emission Spectrometer |
| Sample Introduction | Direct liquid introduction |
| Waste Disposal | Rear exhaust configuration |
| Atomization Mode | Vapor generation / Hydride generation |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Detection Limit | ≤1 ppb (μg/L) for most elements |
| Precision | RSD ≤1.5% |
| Stability | RSD ≤2.0% |
| Linear Dynamic Range | 5 orders of magnitude |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (±0.05%) |
| RF Power Output | 800–1600 W (±0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Minimum Sample Volume | >1 mL |
| Operating Temperature | 20–45 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Software | PICP-V2.1 multi-language platform (CN/EN/KO/JP), compliant with ASTM D6595, D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Direct Nebulization |
| Waste Disposal | Rear Exhaust Design |
| Gas Flow Control | Rotameter-Based Pneumatic System |
| Detectable Elements | Al, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce |
| Relative Standard Deviation (RSD) | <1% |
| Linear Dynamic Range | 5 orders of magnitude (0.01–10,000 µg/L) |
| Detection Limits | Sub-ppb (≤0.01 µg/L) for most elements |
| Photomultiplier Tube Wavelength Range | 200–1000 nm |
| Atomizer Temperature Control Range | Ambient to 45 °C |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Requirement | >1 mL |
| Operating Temperature | 15–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Brand | PULUODY |
|---|---|
| Model | P-ICP-II |
| Origin | Shaanxi, China |
| Detection Principle | Rotating Disc Electrode Atomic Emission Spectrometry (RDE-AES) |
| Spectral Range | 190–800 nm |
| Optical Resolution | ≤0.015 nm |
| RF Generator Frequency | 27.12 MHz (stability ≤0.05%) |
| RF Power Output | 800–1600 W (stability ≤0.2%) |
| Grating Density | 2400 lines/mm |
| Grating Area | 80 × 110 mm |
| Sample Volume Required | >1 mL |
| Operating Temperature | 20–45 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Elemental Detection Capability | ≥61 elements |
| Detection Limit | down to 1 ppb (µg/L) for most metals |
| Linear Dynamic Range | 5 orders of magnitude |
| Analysis Speed | ≥4 elements per minute |
| Precision (RSD) | ≤1.5% |
| Stability (RSD) | ≤2.0% |
| Accuracy | ±3% (method-dependent) |
| Compliance Standards | ASTM D6595, ASTM D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018 |