- All
- Favorite
- Popular
- Most rated
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-H |
| Price | USD 72,800 (approx.) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.5–5.0 µm |
| Repeatability | ≤3% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Metering Plunger Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Sample Interface | 4–20 mA Analog Output |
| Data Acquisition | iPad-Compatible Wireless Interface |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Reporting Units | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Voltage Input | 100–265 VAC, 50–60 Hz |
| Counting Accuracy | <±1% volumetric error |
| coincidence limit | 1000 particles/mL (≤2.5% coincidence error) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PSD-PF10A-0.5 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Cleanroom Classification | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Repeatability | ±1% |
| Measurement Time | 15 s |
| Airflow Velocity Range | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for microbial reduction to sterile conditions |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1511 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–500 µm |
| Repeatability | <1% |
| Measurement Time | 60 sec |
| Detection Principle | Optical Diffraction & Scattering / Laser Flow Imaging |
| Compliance | ISO 13320, ISO 13321 |
| Sample Throughput | One sample per ≤2 min |
| Software Interface | Bilingual (English/Chinese), Windows-compatible |
| Reporting | D3, D10, D25, D50, D75, D80, D90, D97, D100, Span, Specific Surface Area, Aspect Ratio, Circularity Distribution |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PLD-601 |
| Price Range | USD 55,000–69,000 (FOB UK) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.1–800 µm |
| Repeatability | ≥99% |
| Measurement Time | 10–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanliness Classes | ISO Class 4 (10 particles/ft³ ≥0.1 µm), ISO Class 5 (100 particles/ft³ ≥0.5 µm) |
| Airflow Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Germicidal Lamp |
| Optional Accessories | Pneumatic Rotary Stage (bidirectional), High-Purity Nitrogen Inlet with Particle Filter, Adjustable Gooseneck Nozzle |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration (LO) Particle Counter |
| Measurement Range | 1–500 µm |
| Repeatability | 1000 particles/mL (2.5% coincidence error) |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2-K |
| Price | USD 34,800 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 2–750 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Software Version | V8.3 Integrated Analysis & Calibration Suite (PC + Touchscreen) |
| Sampling Accuracy | <±1% |
| Size Accuracy | <±3% (typ.) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with customizable over-limit alarm |
| Reporting | Particles/mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1–450 µm |
| Repeatability | <5% |
| Measurement Time | 20 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC-2300 |
| Price | ¥98,000 |
| Dispersion Method | Dry/Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 2–750 µm |
| Repeatability | ±5% |
| Measurement Time | 0.01 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1513-a |
| Price | USD 39,200 (approx.) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 1% |
| Measurement Time | 30–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513-b |
| Origin | Shaanxi, China |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 5% |
| Measurement Time | 30–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 1–150 µm |
| Repeatability | 1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Microscopy-Based Particle Counting System |
| Measurement Range | 1 µm – 500 µm |
| Repeatability | < 5% (excluding sample preparation variability) |
| Analysis Time | 60 seconds |
| Magnification | 40× – 1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm division) |
| Software Environment | Windows OS (XP through 11) |
| Interface | RS-232 or USB |
| Particle Recognition Accuracy | >95% (per ChP 2020), <10% misclassification (per USP <788> & ISO 21501-1) |
| Overlap Tolerance | ≤5% at 10,000 particles/mL |
| Image Stitching | Fully automated, seam-free membrane scanning |
| Segmentation Speed | <1 second per field |
| Segmentation Success Rate | >93% |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PS8011 |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ±1% RSD |
| Measurement Time | ≤10 seconds |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Laser Particle Counter |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ±3% |
| Measurement Time | 60 s |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2020, GB 8368 |
| Data Output | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Analog Output | 4–20 mA with customizable alarm threshold |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PLD-601-X |
| Price | USD 26,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 5–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Sample Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Counting Resolution | 0.1 µm (c) minimum detectable threshold |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Analog Output | 4–20 mA |
| Data Interface | IPAD-compatible wireless acquisition system |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-601 |
| Price | USD 35,200 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm available upon configuration) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | ≤60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm optional) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2-S |
| Price | USD 53,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | ≤60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | OPCI Series |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1–150 µm |
| Repeatability | ±1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513 |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Laser Diffraction & Flow Imaging Hybrid Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | <5% (D50) |
| Measurement Time | ≤30 s per sample |
| Detection Principle | Laser Diffraction (ISO 13320 compliant) + Hydrodynamic Focusing Flow Imaging (ISO 13321 compatible) |
| Sample Introduction | Static cuvette & recirculating wet dispersion unit |
| Software Platform | Windows-native, bilingual (EN/CN), 20 report templates |
| Compliance | SY/T 5329–2012, Q/SY 01004–2016, SY/T 6596–2016, SY/T 5523–2016 |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
Show next