Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULL
OriginShaanxi, China
ModelPLD-11901
Instrument TypeBenchtop Water Quality Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filter MembraneGlass Fiber or Quantitative Filter Paper (φ50 mm or φ60 mm, pore size 0.45 µm)
Drying Temperature103–105 °C (controlled at 104 ± 1 °C)
Weighing Accuracy≥ 0.1 mg
Vacuum Pressure Range20–80 kPa
Maximum Vacuum Flow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10 %, 50 Hz
Detection Limit2 mg/L
Recommended Sample Volume100 mL (adjustable for 5–100 mg expected suspended solids mass)
Compliance BasisAligns with ISO 11923:1997, EPA Method 160.2, and GB/T 11901–1989
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-11901
Instrument TypePortable Suspended Solids Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filtration MembraneGlass fiber or quantitative filter paper (φ50 mm or φ60 mm, pore size 0.45 µm)
Drying Temperature104 ± 1 °C
Weighing Accuracy≥ 0.1 mg
Vacuum Pressure Range20–80 kPa
Maximum Vacuum≥ 80 kPa
Airflow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10%, 50 Hz
Detection Range2–1000 mg/L (practical optimal range: 5–100 mg suspended solids per sample)
Sample Volume100 mL (adjustable based on expected concentration)
Compliance BasisASTM D5907, ISO 11923, EPA Method 160.2, GB/T 11901–1989
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPSD-351B
Instrument TypePortable Water Quality Analyzer
Detection TargetsSurface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water
Applicable StandardsSY/T 5329–2012, GB 11901–1989, GB/T 7600, GB/T 11133, GB/T 606
Gas SourceNitrogen (optional or customer-supplied)
Filter Diameterφ43 mm
Sample Volume Capacity3500 mL
Dimensions (L×W×H)≤500×500×800 mm
Construction MaterialsOrganic Glass (PMMA), Stainless Steel, Corrosion-Resistant Components
Pressure Regulation SystemIntegrated Inlet Pressure Control with Relief Valve, Pressure Gauge, Inlet/Outlet Valves
Temperature MeasurementDigital Thermometer
Timing MethodPrecision Stopwatch
Filtration ModuleBubble-Elimination Enabled High-Molecular-Weight Membrane Holder
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCALDEE
OriginShaanxi, China
ModelPLD-11901
Instrument TypeBenchtop Water Quality Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filter Diameterφ50 mm or φ60 mm
Drying Temperature104 ± 1 °C
Weighing Precision≥ 0.1 mg
Minimum Detectable Concentration2 mg/L
Maximum Negative Pressure≥ 80 kPa
Vacuum Adjustment Range20–80 kPa
Airflow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10 %, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelPLD-11901
Instrument TypeLaboratory Water Quality Analyzer
Detection ParameterSuspended Solids (SS) in Surface Water, Groundwater, Domestic Wastewater, and Industrial Effluents
Filtration Pore Size0.45 µm
Filter Diameterφ50 mm or φ60 mm
Drying Temperature Range103–105 °C
Weight Precision≥0.1 mg
Maximum Vacuum Pressure≥80 kPa
Vacuum Adjustment Range20–80 kPa
Airflow Rate≥20 L/min
Noise Level≤60 dB(A)
Power SupplyAC 220 V ±10%, 50 Hz
Detection Limit2 mg/L
Gravimetric Accuracy Endpoint≤0.4 mg mass difference between consecutive weighings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPSD-351B
OriginShaanxi, China
Instrument TypeLaboratory Water Quality Analyzer
Application ScopeSurface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water
Compliance StandardsSY/T 5329–2012, GB 11901–1989, GB/T 606–2006, GB/T 11133–2015, GB 7600–2014
Gas SourceNitrogen (externally supplied or optional integrated regulator)
Filter Diameterφ43 mm
Housing MaterialsCorrosion-resistant stainless steel + optical-grade acrylic
Pressure RegulationIntegrated pressure-reducing valve, precision pressure gauge, and dual-stage flow control valves
Temperature MonitoringDigital electronic thermometer (±0.5 °C accuracy)
TimingManual stopwatch interface with synchronized logging capability
Membrane De-airing FunctionIntegrated venting mechanism to eliminate air bubbles on membrane surface
Filtration ModeConstant-pressure gravimetric filtration