Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelPULL-GP20-1000
Instrument TypeStandard Gas Sampler
ConfigurationSingle-Port Sampling Cylinder
Flow Range0–20 L/min
Maximum Sampling Pressure0–20 MPa
Flow Stability±1% FS
Flowmeter Accuracy±1% FS
Service Life Under Max Flow & Backpressure≥100,000 cycles
Continuous Operation at Max Flow & Backpressure24 h
Working Pressure Range4–20 MPa
Burst Pressure Rating7–38 MPa
Operating Temperature Range–60 °C to +80 °C
Cylinder MaterialASTM A240 UNS S31603 (316L stainless steel) or GB/T 1220 1Cr18Ni9Ti
Internal Coating (Optional)PTFE lining
Pressure GaugeIntegrated bourdon-tube gauge with direct-read dial
Valve ConfigurationDual-valve assembly — one standard needle valve, one pressure-relief safety valve with burst disc
Mounting Bracket304 stainless steel support stand (optional)
Volume Capacity1000 mL
ComplianceSH/T 0233–1992, SY/T ZJ1045
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPULL-GP20-300
Instrument TypeSingle-Channel Cryogenic Gas/Liquid Sampler
Flow Range0–20 L/min
Maximum Operating Pressure4–20 MPa
Flow Stability≤5% over 1 h
Flowmeter Accuracy≥±2.5% FS
Service Life at Max Flow & Backpressure≥5000 h
Continuous Operation Duration at Max Flow & Backpressure8 h
Construction MaterialASTM A240 316L Stainless Steel
Operating Temperature Range–190 °C to +80 °C
Volumetric Capacity Options100 mL to 5000 mL
ComplianceSH/T 0233–1992 (Liquefied Petroleum Gas Sampling Method)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULL
OriginShaanxi, China
ModelPLD-11901
Instrument TypeBenchtop Water Quality Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filter MembraneGlass Fiber or Quantitative Filter Paper (φ50 mm or φ60 mm, pore size 0.45 µm)
Drying Temperature103–105 °C (controlled at 104 ± 1 °C)
Weighing Accuracy≥ 0.1 mg
Vacuum Pressure Range20–80 kPa
Maximum Vacuum Flow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10 %, 50 Hz
Detection Limit2 mg/L
Recommended Sample Volume100 mL (adjustable for 5–100 mg expected suspended solids mass)
Compliance BasisAligns with ISO 11923:1997, EPA Method 160.2, and GB/T 11901–1989
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-11901
Instrument TypePortable Suspended Solids Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filtration MembraneGlass fiber or quantitative filter paper (φ50 mm or φ60 mm, pore size 0.45 µm)
Drying Temperature104 ± 1 °C
Weighing Accuracy≥ 0.1 mg
Vacuum Pressure Range20–80 kPa
Maximum Vacuum≥ 80 kPa
Airflow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10%, 50 Hz
Detection Range2–1000 mg/L (practical optimal range: 5–100 mg suspended solids per sample)
Sample Volume100 mL (adjustable based on expected concentration)
Compliance BasisASTM D5907, ISO 11923, EPA Method 160.2, GB/T 11901–1989
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPULL-GP20-500
Instrument TypeGeneral-Purpose Gas Sampler
ConfigurationSingle-Channel Sampling System
Flow Rate Range0–0.5 L/min
Maximum Suction Pressure0–20 MPa
Flow Stability≤ ±5%
Flowmeter Accuracy≥ ±2.5%
Service Life at Max Flow & Backpressure≥ 5000 h
Drift Under Rated Load≤ ±5%
Material1Cr18Ni9Ti Stainless Steel (AISI 321 Equivalent)
Design Pressure20 MPa
Hydrostatic Test Pressure35 MPa
Operating Temperature Range–60 °C to +80 °C
Available Volumes25 mL to 10,000 mL
ComplianceSH/T 0233, SY/T 1045
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPSD-351B
Instrument TypePortable Water Quality Analyzer
Detection TargetsSurface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water
Applicable StandardsSY/T 5329–2012, GB 11901–1989, GB/T 7600, GB/T 11133, GB/T 606
Gas SourceNitrogen (optional or customer-supplied)
Filter Diameterφ43 mm
Sample Volume Capacity3500 mL
Dimensions (L×W×H)≤500×500×800 mm
Construction MaterialsOrganic Glass (PMMA), Stainless Steel, Corrosion-Resistant Components
Pressure Regulation SystemIntegrated Inlet Pressure Control with Relief Valve, Pressure Gauge, Inlet/Outlet Valves
Temperature MeasurementDigital Thermometer
Timing MethodPrecision Stopwatch
Filtration ModuleBubble-Elimination Enabled High-Molecular-Weight Membrane Holder
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCALDEE
OriginShaanxi, China
ModelPLD-11901
Instrument TypeBenchtop Water Quality Analyzer
Detection PrincipleGravimetric Filtration (0.45 µm membrane)
Filter Diameterφ50 mm or φ60 mm
Drying Temperature104 ± 1 °C
Weighing Precision≥ 0.1 mg
Minimum Detectable Concentration2 mg/L
Maximum Negative Pressure≥ 80 kPa
Vacuum Adjustment Range20–80 kPa
Airflow Rate≥ 20 L/min
Noise Level≤ 60 dB(A)
Power SupplyAC 220 V ± 10 %, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelDPC-2615
Instrument TypeHandheld
Flow Rate1.0 L/min
Flow Accuracy≤ ±5%
Timing Accuracy≤ ±1 s
Repeatability≤ ±5%
Size Distribution Accuracy≤ ±5%
Indication Error≤ ±5%
PM Measurement ChannelsPM1.0, PM2.5, PM10, TSP
Mass Concentration Range0–10 mg/m³ (extendable to 100 mg/m³)
Laser SourceIEC 60825-1 Class 2
Response Time1 s
Data Storage Capacity≥ 7,000,000 records
Battery Life≥ 4.5 h @ 25°C, 50% RH
Operating Temperature−20 to +60°C
Relative Humidity Range0–99% RH
Atmospheric Pressure Range86–110 kPa
Power InputDC 16.8 V / 1 A
Rated Power4.1 W
Display3.5-inch touchscreen
Dimensions175 × 105 × 65 mm
Weight0.89 kg
Calibration TraceabilityNIST-traceable standard particles
Compliance StandardsHJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPLD-11901
Instrument TypeBenchtop Laboratory Analyzer
Filtration Pore Size0.45 µm
Filter Diameterφ50 mm or φ60 mm
Drying Temperature Control104 ± 1 °C
Gravimetric Accuracy≥0.1 mg
Maximum Vacuum Pressure≥80 kPa
Vacuum Adjustment Range20–80 kPa
Airflow Rate≥20 L/min
Acoustic Noise Level≤60 dB(A)
Power SupplyAC 220 V ±10%, 50 Hz
Detection Limit2 mg/L
Recommended Sample Mass Range5–100 mg (corresponding to 100 mL sample volume at typical concentrations)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelDPC-2615A
Instrument TypeHandheld
Flow Rate1 L/min
Flow Accuracy≤±5%
Timing Error≤±1 s
Repeatability≤±5%
Size Distribution Error≤±5%
Indication Error≤±5%
PM1.0 Accuracy±9.5% or ±7.5 µg/m³
TSP Accuracy±15% or ±25 µg/m³
Operating Temperature−20–60 °C
Relative Humidity Range0–99% RH
Atmospheric Pressure Range86–110 kPa
Response Time1 s
Data Storage Capacity≥7,000,000 records
Battery Life≥4 h (25 °C, 50% RH)
Laser SourceIEC 60825-1 Class 2
Compliance StandardsHJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelPLD-11901
Instrument TypeLaboratory Water Quality Analyzer
Detection ParameterSuspended Solids (SS) in Surface Water, Groundwater, Domestic Wastewater, and Industrial Effluents
Filtration Pore Size0.45 µm
Filter Diameterφ50 mm or φ60 mm
Drying Temperature Range103–105 °C
Weight Precision≥0.1 mg
Maximum Vacuum Pressure≥80 kPa
Vacuum Adjustment Range20–80 kPa
Airflow Rate≥20 L/min
Noise Level≤60 dB(A)
Power SupplyAC 220 V ±10%, 50 Hz
Detection Limit2 mg/L
Gravimetric Accuracy Endpoint≤0.4 mg mass difference between consecutive weighings
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPSD-351B
OriginShaanxi, China
Instrument TypeLaboratory Water Quality Analyzer
Application ScopeSurface Water, Groundwater, Domestic Wastewater, Industrial Effluent, Oilfield Injection Water
Compliance StandardsSY/T 5329–2012, GB 11901–1989, GB/T 606–2006, GB/T 11133–2015, GB 7600–2014
Gas SourceNitrogen (externally supplied or optional integrated regulator)
Filter Diameterφ43 mm
Housing MaterialsCorrosion-resistant stainless steel + optical-grade acrylic
Pressure RegulationIntegrated pressure-reducing valve, precision pressure gauge, and dual-stage flow control valves
Temperature MonitoringDigital electronic thermometer (±0.5 °C accuracy)
TimingManual stopwatch interface with synchronized logging capability
Membrane De-airing FunctionIntegrated venting mechanism to eliminate air bubbles on membrane surface
Filtration ModeConstant-pressure gravimetric filtration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2DRD
Detection PrincipleCapacitive Sensing with Dual-Laser Narrow-Beam Optical Verification
Detection Range0.5–20.0 µm (standard)
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% error at 1000 particles/mL
Repeatability5%
Power Input100–265 VAC, 50–60 Hz
Output Interface4–20 mA analog signal with configurable particle concentration alarm
Compliance StandardsJJG 1061, ISO 21501-4, USP <788> & <789>, ASTM F3232
Software PlatformPULUODY V8.3 Integrated Analysis Suite (PC & tablet-compatible)
Display & ControlColor LCD touchscreen + optional wireless keyboard/mouse
Sample DeliveryPrecision metering piston pump with electromagnetic flow regulation
Data OutputParticle count per mL and ISO 4406 / NAS 1638 contamination code reporting
Show next