- All
- Favorite
- Popular
- Most rated
| Brand | PULUODY |
|---|---|
| Model | PMT-2GT |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard), customizable to 1–100 µm or 4–70 µm(c) |
| Resolution | 0.1 µm(c) minimum detectable threshold |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm triggers |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex sphere reference materials |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Model | PMT-2DJY |
| Detection Principle | Dual-laser narrow-beam light scattering |
| Sensor Generation | 8th-generation dual-laser optical particle sensor |
| Measurement Range | 0.5–20.0 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision piston pump + ultra-precise electromagnetic flow regulation |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alarm |
| Data Acquisition | iPad-integrated wireless acquisition |
| Software | V8.3 Integrated Analysis & Calibration Software (PC version) |
| Display & Control | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1 cleanroom monitoring, USP <788> and <789> particulate matter testing, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2CS |
| Price | USD 72,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Measuring Range | 0.05–2.0 µm (standard), 0.1–0.5 µm (high-sensitivity mode) |
| Customizable Ranges | 1–100 µm or 4–70 µm (c), 0.1 µm (c) selectable |
| Sampling Method | Precision Metering Piston Pump |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alarm |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Particle Analysis Suite (PC + embedded touchscreen interface) |
| Compliance | Designed for ISO 14644-1 cleanroom monitoring, SEMI F57, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Model | PMT-2SD |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation |
| Measuring Range | 0.1–0.5 µm & 0.5–5.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Output | 4–20 mA analog interface,超标 alarm output (customizable) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI) |
| Display | Color LCD touch interface + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2, USP <788>, ISO 8573-4, and semiconductor-grade liquid purity monitoring workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-261D |
| Price | USD 7,800 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | CLDEE-CCACS2.0 |
| Price | USD 5,180 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2CD |
| Price | USD 75,000 (FOB) |
| Detection Range | 1–450 µm |
| Calibration Standard | ISO 21501-4 / JJG 1061 / NIST-Traceable Latex Spheres |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with customizable particle concentration alarm threshold |
| Data Interface | iPad-compatible wireless acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Standalone Touchscreen Mode) |
| Compliance | Designed to support ISO 14644-1 cleanroom monitoring, USP <788> and <789>, ASTM F3231, and GLP/GMP-aligned audit trail requirements |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2T |
| Price | USD 31,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Measurement Range | 1–450 µm |
| Customizable Sub-Ranges | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Output Interface | 4–20 mA analog output with configurable alarm relay |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | PLD-260C |
| Price | USD 780 (FOB Shanghai) |
| Brand | PULUODY |
|---|---|
| Model | PLD-FX-801LX |
| Detection Principle | Dual-mode (Light Obscuration + Light Scattering) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Measurement Range | 0.5–100.0 µm |
| Customizable Sub-ranges | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Sample Delivery | Precision metering pump |
| Output | 4–20 mA analog interface with configurable alarm triggers |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11–ready configuration options |
| Power Input | 100–265 VAC, 50–60 Hz |
Show next