Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelPLD-MPCS2.0-B
PriceUSD 53,800 (approx.)
Microscope ConfigurationUpright
Integrated Image Analysis SystemYes
Total Magnification Range40× to 1000×
Eyepiece10×
Objective Lenses10× (standard), with optional 4×, 20×, 40×, 100× oil immersion
Camera Resolution3 MP CCD
Optical Resolution0.1 µm
Measurement Accuracy±3% (typical)
Repeatability Error<5% (excluding sample preparation variability)
Particle Detection Resolution>95% (calibrated per ChP 2020)
Coincidence Limit10,000 particles/mL (5% coincidence error)
Image Segmentation Speed<1 sec per frame
Segmentation Success Rate>93%
Calibration ValidationCertified by Northwest National Metrology & Testing Center (Civil Products)
Software CompatibilityWindows 2000/XP (legacy support)
Analytical OutputsParticle size distribution (1–500 µm), aspect ratio distribution, circularity distribution, particle count per volume, length-weighted mean diameter, projected area equivalent diameter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-MPCS2.0-C
Microscope TypeUpright Metallurgical Microscope
Image Analysis SystemIntegrated
Total Magnification Range40× to 1000×
Eyepiece10×
Objective Lenses20× (standard), with full parfocal objective set supporting 4×, 10×, 40×, 100× oil immersion
Resolution0.1 µm
Measurement Accuracy±3% (typical, per ChP 2020 calibration)
Repeatability Error<5% (excluding sample preparation variability)
Digital CCD Camera3 MP
Particle Detection Efficiency>95% (per ChP 2020)
Particle Concentration LimitUp to 10,000 particles/mL (5% coincidence error threshold)
Automatic Segmentation Speed<1 s per field-of-view
Segmentation Success Rate>93%
Calibration Standard TraceabilityCertified by Northwest National Metrology & Testing Center (Civil Products)
Compliance StandardsChP 0903 (2015/2020), USP <788>, <789>, EP 6.0–8.0, BP 2009–2013, JP 14–16, IP 2010, WHO IntPh V, GB/T 11446.9–2013, ISO 21510, ISO 11171, GB 8368
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2YC
PriceUSD 75,000 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Measurement Range0.5–20.0 µm (standard)
Sensor Generation8th-Generation Dual-Laser Particle Sensor
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex spheres
Output Interface4–20 mA analog output with programmable alarm thresholds
Data ReportingParticles per mL and ISO 4406 / NAS 1638 contamination codes
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC + iPad-compatible)
Display & ControlColor LCD touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-MPCS2.0-A
Microscope TypeUpright
Image Analysis SystemIntegrated
Total Magnification Range40× to 1000×
Detection Range1 μm – 500 μm
Resolution0.1 μm
Repeatability Error< 5% (excluding sample preparation variability)
CCD Camera3 MP
Calibration Accuracy±3% (typical)
Particle Segmentation Speed< 1 s
Segmentation Success Rate> 93%
Software PlatformWindows 2000 / XP
InterfaceRS232 or USB
Compliance StandardsUSP <788>, USP <789>, EP, JP, ChP 2020, GB/T 11446.9-2013, ISO 21501, ISO 21510, ASTM F312, ISO 4406 (adapted)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2GJ
PriceUSD 75,000 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Calibration StandardsISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres
Detection Range0.1–100 µm (configurable sub-ranges: 0.1–0.5 µm, 4–70 µm(c), or user-defined 1–100 µm)
Sample Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% error at 1000 particles/mL
Output4–20 mA analog signal,超标 alarm relay (customizable)
Data InterfaceiPad-compatible wireless acquisition, USB, RS232
Display & ControlColor LCD touchscreen + optional wireless keyboard/mouse
ReportingParticles per mL and ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC & embedded)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0