BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPSD-650
PriceUSD 2,500 (FOB)
ComplianceGB/T 7597, IEC 60475, ASTM D923
Temperature SensorPT100 (±0.5 °C accuracy)
PowerReplaceable Battery
DesignPhysically Isolated Sampling Tube & Display Module
Sampling MethodContinuous Flushing Capability
Form FactorIntegrated Compact Assembly with Multi-Valve Control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-IGS-2025
OriginShaanxi, China
Housing Material316L Stainless Steel
Sample Volume1 L
Maximum Working Pressure≥1.3 MPa
Vacuum Pump Control Threshold1.3 MPa (auto-shutoff with overpressure cutoff and audible/visual alarm)
ComplianceDesigned for ISO/IEC 17025-aligned laboratory workflows, compatible with ASTM D6164 (gas sampling for radionuclide analysis), USP <661>, and IAEA Safety Standards RS-G-1.7
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULL
ModelPSD-650
OriginShaanxi, China
ComplianceGB/T 7597, IEC 60475, ASTM D923
Temperature SensorPT100 (±0.5 °C)
PowerReplaceable Battery
DesignIntegrated, Explosion-Protected, Physically Isolated Sampling Circuit
Sampling MethodContinuous Flushing Enabled
Form FactorCompact, Multi-Valve Integrated Unit
ApplicationIn-Service Transformer Oil Sampling for Dissolved Gas Analysis (DGA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelDMA-135D
PrincipleU-tube Oscillation Method
Measurement Range0.0000–3.0000 g/cm³
Resolution0.0001 g/cm³
Accuracy±0.001 g/cm³
Repeatability±0.0005 g/cm³
Temperature Range0.0–50.0 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.2 °C
Temp. Repeatability±0.1 °C
Sample Volume2 mL
Sampling MethodManual syringe or integrated pump (for liquids < 2000 mPa·s)
Measurement Time≤60 s
Display2.4″ color LCD, 320×240 pixels
Power9 V alkaline battery
Battery Life~90 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601ZY
Detection PrincipleLight Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing
Channel Count1000 adjustable channels
Detection Range1–450 µm
Minimum Detectable Size0.01 µm (c)
Sampling Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Sample Temperature Range0–80 °C
Ambient Operating Temperature0–50 °C
Accuracy±5% typical (per USP <788>, ISO 21501)
Coincidence Limit≤5% at 1000 particles/mL
Resolution>95% (ChP 2020 calibration), <10% (USP/ISO 21501 calibration)
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow regulation
Software ComplianceFDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, data backup & restore, power-fail recovery
Regulatory Standards SupportedChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPLD-IGS-2025
PriceUSD 3,650 (FOB)
Vessel Material316L Stainless Steel
Vessel Capacity1 L
Maximum Working Pressure≥1.3 MPa
Vacuum Pump Control Threshold1.3 MPa (auto-shutoff with audible/visual alarm)
Safety FeaturesOverpressure cutoff, leak-resistant isolation valve, pressure relief mechanism
ComplianceDesigned to meet ASTM D6159–22 (Standard Practice for Sampling Gaseous Effluents), ISO 8573-1:2010 (Compressed Air – Part 1: Contaminants and Purity Classes), and IAEA Safety Standards Series No. SSG-24 (Radiation Protection and Safety of Radiation Sources)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelPSD-650
PriceUSD 2,500 (approx.)
Sampling Volume Range100–1000 mL
Temperature Measurement Range−20 °C to 200 °C
Temperature Sensor Accuracy±0.5 °C (PT100 embedded probe)
ComplianceIEC 60475, ASTM D923, GB/T 7597
Core ComponentsTwo gas-tight glass syringes (standard 100 mL), two 600 mL aluminum sample cylinders, dual-port valves, 1 m PVC sampling hose, insulated carrying case with foam inserts
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2RX
Sensor Technology8th-generation dual-laser narrow-beam particle detection
Detection Range0.1–0.5 µm and 0.5–5.0 µm (customizable from 0.1 µm to 100 µm)
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% at 1000 particles/mL
Calibration StandardsJJG 1061, ISO 21501, or NIST-traceable latex spheres
Output Interface4–20 mA analog output with configurable contamination alarm
Data ReportingParticles per mL and ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP-aligned environments
SoftwareV8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPSD-250
PricingUpon Request
MaterialLC Super-Hard Aluminum Alloy
Capacity Options100–1000 mL (customizable for food-grade, pharmaceutical-grade, sterile, and corrosion-resistant applications)
Tubing Diameter4 mm / 6 mm / 8 mm (customizable)
Max Vacuum Pressure2 kPa
Tubing ComplianceNAS 1638 Class 0
Cleaning Bottle GradeNAS 1638 Classes 0–4 (customizable)
StandardsGB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2-U
PriceUSD 72,800 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Detector
Calibration StandardsISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres
Measuring Range0.05–0.2 µm, 0.1–0.5 µm
Customizable Channels1–100 µm or 4–70 µm(c), down to 0.1 µm(c)
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typ.)
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Flow ControlPrecision Plunger Pump + Electromagnetic Flow Regulation
Data Output4–20 mA Analog Interface, Real-Time Alarm Trigger
ReportingParticles per mL & ISO 4406 / NAS 1638 Contamination Code
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP environments
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC + iPad-compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelPMT-2
PriceUSD 72,800 (approx. based on ¥520,000 @ 1 USD = ¥7.15)
Sensor Generation8th-generation dual-laser narrow-beam optical sensor
Detection Range0.1–0.5 µm (standard)
Sampling MethodPrecision metering piston pump
Flow ControlDual-stage — high-accuracy piston pump + ultra-precise electromagnetic flow regulator
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Error≤2.5% at 1000 particles/mL
Calibration StandardsISO 21501-4, JJG 1061, NIST-traceable latex spheres
ComplianceChinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368
Output Interface4–20 mA analog output
Alarm FunctionConfigurable particle threshold alert
Data AcquisitioniPad-integrated real-time acquisition
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version)
DisplayColor LCD touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ReportingParticles per mL + ISO 4406 / NAS 1638 contamination codes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-FX-801PL
Detection PrincipleDual-mode (Light Scattering + Light Obscuration)
Sensor Generation8th-generation dual-laser narrow-beam particle sensor
Measuring Range0.5–100.0 µm
Customizable Channels1–100 µm or 4–70 µm (c), down to 0.1 µm (c)
Sampling Accuracy<±1%
Counting Accuracy<±3% typical
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Flow ControlPrecision metering pump with dual-stage automatic dilution
Data Output4–20 mA analog interface with configurable alarm trigger
Calibration StandardsJJG 1061, ISO 21501, or NIST-traceable latex spheres
SoftwareV8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI)
Compliance SupportGLP/GMP audit trail logging, FDA 21 CFR Part 11-ready configuration options
Power Input100–265 VAC, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPSD-250
Sample Volume Options100–1000 mL (customizable, including food-grade, pharmaceutical-grade, sterile, and corrosion-resistant variants)
Tubing Diameter4–8 mm (customizable)
Maximum Vacuum Pressure2 kPa
Tubing ComplianceNAS 1638 Class 0
Cleaning Bottle CleanlinessNAS 1638 Classes 0–4 (customizable)
Material OptionsLC super-hard aluminum alloy (zinc-plated for corrosion resistance) or engineering-grade polymer (molded, hermetic seal)
Standards ComplianceGB/T 17489–1998, QC/T 29105.3–1992, DL/T 571–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPLD-601X
PriceUSD 26,500 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelPLD-601-D
PriceUSD 26,500 (FOB)
Sensor Generation8th-generation dual-laser narrow-beam particle sensor
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow control system
Detection Range0.01 µm to 450 µm (customizable sub-ranges: e.g., 1–100 µm, 4–70 µm(c), or 0.1 µm(c))
Channel Count1000 user-definable size channels
Sampling Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Sample Temperature Range0–80 °C
Ambient Operating Temperature0–50 °C
Accuracy±5% typical (per USP <788>, ISO 21501)
Coincidence Limit≤5% error at 1000 particles/mL
Resolution>95% (ChP 2015/2020 calibrated)
ComplianceFDA 21 CFR Part 11 (audit trail, electronic signature, role-based 5-level access, data backup/recovery, power-fail protection)
SoftwareV8.9 Particulate Analysis Suite (PC + embedded touchscreen)
Calibration StandardsJJG 1061, ISO 21501, NIST-traceable latex spheres
Regulatory AlignmentChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019, JP 17, IP 2015, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, NAS 1638, ISO 11171, MIL-STD-1246, SAE AS749D
Metrology SupportAccredited by NW National Metrology Center (CNAS) and Defense Science & Technology Commission Particle Metrology Station No. 116
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPSD-650
PriceUSD 2,500 (FOB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2
PriceUSD 67,500 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Plunger Pump + Electromagnetic Flow Regulation
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018
Measurement Range0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c)
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Output Interface4–20 mA analog output
Alarm FunctionConfigurable particle concentration threshold alert
Data AcquisitioniPad-compatible wireless telemetry & local touchscreen (color LCD)
SoftwarePULUODY V8.3 Particle Analysis Suite (PC & embedded integrated edition)
ComplianceSupports 21 CFR Part 11 audit trail, GLP/GMP-compliant reporting modules
Power Input100–265 VAC, 50–60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2BD
PriceUSD 75,000 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Calibration StandardsISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres
Measurement Range0.1–0.5 µm, 0.1–1.0 µm
Customizable Channels1–100 µm or 4–70 µm (c), down to 0.1 µm (c)
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit≤2.5% error at 1000 particles/mL
Output Interface4–20 mA analog output with programmable alarm threshold
Data ReportingParticles per mL and ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
Display & Control7-inch color TFT touchscreen + optional wireless keyboard/mouse
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded versions)
ComplianceDesigned for GLP/GMP environments