- All
- Favorite
- Popular
- Most rated
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Compliance | GB/T 7597, IEC 60475, ASTM D923 |
| Temperature Sensor | PT100 (±0.5 °C accuracy) |
| Power | Replaceable Battery |
| Design | Physically Isolated Sampling Tube & Display Module |
| Sampling Method | Continuous Flushing Capability |
| Form Factor | Integrated Compact Assembly with Multi-Valve Control |
| Brand | PULUODY |
|---|---|
| Model | PLD-IGS-2025 |
| Origin | Shaanxi, China |
| Housing Material | 316L Stainless Steel |
| Sample Volume | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with overpressure cutoff and audible/visual alarm) |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows, compatible with ASTM D6164 (gas sampling for radionuclide analysis), USP <661>, and IAEA Safety Standards RS-G-1.7 |
| Brand | PULL |
|---|---|
| Model | PSD-650 |
| Origin | Shaanxi, China |
| Compliance | GB/T 7597, IEC 60475, ASTM D923 |
| Temperature Sensor | PT100 (±0.5 °C) |
| Power | Replaceable Battery |
| Design | Integrated, Explosion-Protected, Physically Isolated Sampling Circuit |
| Sampling Method | Continuous Flushing Enabled |
| Form Factor | Compact, Multi-Valve Integrated Unit |
| Application | In-Service Transformer Oil Sampling for Dissolved Gas Analysis (DGA) |
| Brand | PULUODY |
|---|---|
| Model | DMA-135D |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Sample Volume | 2 mL |
| Sampling Method | Manual syringe or integrated pump (for liquids < 2000 mPa·s) |
| Measurement Time | ≤60 s |
| Display | 2.4″ color LCD, 320×240 pixels |
| Power | 9 V alkaline battery |
| Battery Life | ~90 h |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601ZY |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing |
| Channel Count | 1000 adjustable channels |
| Detection Range | 1–450 µm |
| Minimum Detectable Size | 0.01 µm (c) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per USP <788>, ISO 21501) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Resolution | >95% (ChP 2020 calibration), <10% (USP/ISO 21501 calibration) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Software Compliance | FDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, data backup & restore, power-fail recovery |
| Regulatory Standards Supported | ChP 0903 (2015/2020), USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-IGS-2025 |
| Price | USD 3,650 (FOB) |
| Vessel Material | 316L Stainless Steel |
| Vessel Capacity | 1 L |
| Maximum Working Pressure | ≥1.3 MPa |
| Vacuum Pump Control Threshold | 1.3 MPa (auto-shutoff with audible/visual alarm) |
| Safety Features | Overpressure cutoff, leak-resistant isolation valve, pressure relief mechanism |
| Compliance | Designed to meet ASTM D6159–22 (Standard Practice for Sampling Gaseous Effluents), ISO 8573-1:2010 (Compressed Air – Part 1: Contaminants and Purity Classes), and IAEA Safety Standards Series No. SSG-24 (Radiation Protection and Safety of Radiation Sources) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PSD-650 |
| Price | USD 2,500 (approx.) |
| Sampling Volume Range | 100–1000 mL |
| Temperature Measurement Range | −20 °C to 200 °C |
| Temperature Sensor Accuracy | ±0.5 °C (PT100 embedded probe) |
| Compliance | IEC 60475, ASTM D923, GB/T 7597 |
| Core Components | Two gas-tight glass syringes (standard 100 mL), two 600 mL aluminum sample cylinders, dual-port valves, 1 m PVC sampling hose, insulated carrying case with foam inserts |
| Brand | PULUODY |
|---|---|
| Model | PMT-2RX |
| Sensor Technology | 8th-generation dual-laser narrow-beam particle detection |
| Detection Range | 0.1–0.5 µm and 0.5–5.0 µm (customizable from 0.1 µm to 100 µm) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Output Interface | 4–20 mA analog output with configurable contamination alarm |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-250 |
| Pricing | Upon Request |
| Material | LC Super-Hard Aluminum Alloy |
| Capacity Options | 100–1000 mL (customizable for food-grade, pharmaceutical-grade, sterile, and corrosion-resistant applications) |
| Tubing Diameter | 4 mm / 6 mm / 8 mm (customizable) |
| Max Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Grade | NAS 1638 Classes 0–4 (customizable) |
| Standards | GB/T 17489–1998, Q/CT 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-U |
| Price | USD 72,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Detector |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Measuring Range | 0.05–0.2 µm, 0.1–0.5 µm |
| Customizable Channels | 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typ.) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Data Output | 4–20 mA Analog Interface, Real-Time Alarm Trigger |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 Contamination Code |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + iPad-compatible) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2 |
| Price | USD 72,800 (approx. based on ¥520,000 @ 1 USD = ¥7.15) |
| Sensor Generation | 8th-generation dual-laser narrow-beam optical sensor |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision metering piston pump |
| Flow Control | Dual-stage — high-accuracy piston pump + ultra-precise electromagnetic flow regulator |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Error | ≤2.5% at 1000 particles/mL |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-traceable latex spheres |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368 |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle threshold alert |
| Data Acquisition | iPad-integrated real-time acquisition |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 contamination codes |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-FX-801PL |
| Detection Principle | Dual-mode (Light Scattering + Light Obscuration) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Measuring Range | 0.5–100.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | <±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision metering pump with dual-stage automatic dilution |
| Data Output | 4–20 mA analog interface with configurable alarm trigger |
| Calibration Standards | JJG 1061, ISO 21501, or NIST-traceable latex spheres |
| Software | V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance Support | GLP/GMP audit trail logging, FDA 21 CFR Part 11-ready configuration options |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-250 |
| Sample Volume Options | 100–1000 mL (customizable, including food-grade, pharmaceutical-grade, sterile, and corrosion-resistant variants) |
| Tubing Diameter | 4–8 mm (customizable) |
| Maximum Vacuum Pressure | 2 kPa |
| Tubing Compliance | NAS 1638 Class 0 |
| Cleaning Bottle Cleanliness | NAS 1638 Classes 0–4 (customizable) |
| Material Options | LC super-hard aluminum alloy (zinc-plated for corrosion resistance) or engineering-grade polymer (molded, hermetic seal) |
| Standards Compliance | GB/T 17489–1998, QC/T 29105.3–1992, DL/T 571–2007 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PLD-601X |
| Price | USD 26,500 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-601-D |
| Price | USD 26,500 (FOB) |
| Sensor Generation | 8th-generation dual-laser narrow-beam particle sensor |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow control system |
| Detection Range | 0.01 µm to 450 µm (customizable sub-ranges: e.g., 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Channel Count | 1000 user-definable size channels |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Ambient Operating Temperature | 0–50 °C |
| Accuracy | ±5% typical (per USP <788>, ISO 21501) |
| Coincidence Limit | ≤5% error at 1000 particles/mL |
| Resolution | >95% (ChP 2015/2020 calibrated) |
| Compliance | FDA 21 CFR Part 11 (audit trail, electronic signature, role-based 5-level access, data backup/recovery, power-fail protection) |
| Software | V8.9 Particulate Analysis Suite (PC + embedded touchscreen) |
| Calibration Standards | JJG 1061, ISO 21501, NIST-traceable latex spheres |
| Regulatory Alignment | ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019, JP 17, IP 2015, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, NAS 1638, ISO 11171, MIL-STD-1246, SAE AS749D |
| Metrology Support | Accredited by NW National Metrology Center (CNAS) and Defense Science & Technology Commission Particle Metrology Station No. 116 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PSD-650 |
| Price | USD 2,500 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,500 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Data Acquisition | iPad-compatible wireless telemetry & local touchscreen (color LCD) |
| Software | PULUODY V8.3 Particle Analysis Suite (PC & embedded integrated edition) |
| Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP-compliant reporting modules |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2BD |
| Price | USD 75,000 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Measurement Range | 0.1–0.5 µm, 0.1–1.0 µm |
| Customizable Channels | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output Interface | 4–20 mA analog output with programmable alarm threshold |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display & Control | 7-inch color TFT touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC & embedded versions) |
| Compliance | Designed for GLP/GMP environments |
Show next