PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPSD-PF100-1A-0.5
Cleanroom ClassISO Class 4 (10-grade) & ISO Class 5 (100-grade)
Airflow ConfigurationHorizontal or Vertical Laminar Flow
FiltrationDual-stage — Pre-filter + HEPA (H14, ≥99.995% @ 0.3 µm)
Operating Air Velocity0.25 m/s ±10%
Vibration Amplitude≤3 µm
Sound Pressure Level≤67 dB(A)
UV Germicidal Lamp254 nm, 15 W
IlluminationFluorescent, ≥300 lx
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Ambient Temp.10–30 °C
Relative Humidity≤75% RH
Dimensions (W×D×H)360 × 450 × 580 mm
ConstructionPowder-coated steel frame, 304 stainless steel work surface
Optional AccessoriesHigh-purity nitrogen inlet with inline filter, articulated nitrogen purge nozzle, programmable bidirectional sample rotator
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Instrument TypeRotating Disc Electrode (RDE) Atomic Emission Spectrometer
Sample IntroductionDirect liquid introduction
Waste DisposalRear exhaust configuration
Atomization ModeVapor generation / Hydride generation
Detectable ElementsAl, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce
Detection Limit≤1 ppb (μg/L) for most elements
PrecisionRSD ≤1.5%
StabilityRSD ≤2.0%
Linear Dynamic Range5 orders of magnitude
Spectral Range190–800 nm
Optical Resolution≤0.015 nm
RF Generator Frequency27.12 MHz (±0.05%)
RF Power Output800–1600 W (±0.2%)
Grating Density2400 lines/mm
Grating Area80 × 110 mm
Minimum Sample Volume>1 mL
Operating Temperature20–45 °C
Relative Humidity0–90% RH (non-condensing)
SoftwarePICP-V2.1 multi-language platform (CN/EN/KO/JP), compliant with ASTM D6595, D6728, NB/SH/T 0865, SN/T 1652, DL/T 1550, JJF (Defense) 1752018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-601W
OriginShaanxi, China
Detection PrincipleLight Obscuration (LO) / Dual-Laser Narrow-Beam Particle Sensing
Sensor Generation8th-Generation Dual-Laser Narrow-Beam Detector
Flow ControlPrecision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System
Measurement Range1–450 µm (customizable sub-ranges: 1–100 µm or 4–70 µm(c)
Channel Count1000 adjustable channels
Sampling Flow Rate5–150 mL/min
Cleaning Flow Rate5–500 mL/min
Sample Temperature Range0–80 °C
Ambient Operating Temperature0–50 °C
Accuracy±5% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤5% at 1000 particles/mL
Resolution>95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated)
Sampling Precision<±1%
Compliance StandardsChP 0903 (2015/2020), USP <788>, <789>, <797>, EP 10.0, BP 2019, YBB00272004-2015, ISO 21501-4, ISO 4406, NAS 1638, GB/T 11446.9-2013, JJG 1061
SoftwareV8.9 Integrated Analysis Suite (PC & embedded touchscreen) with 5-level user权限 management, audit trail, electronic signature, and 21 CFR Part 11 compliance
Data IntegrityAuto-backup, restore, power-fail recovery, GLP/GMP-ready reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2GK
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Detection Range0.1–0.5 µm (standard), customizable to 1–100 µm or 4–70 µm (c)
Calibration StandardsJJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Spheres
Sampling MethodPrecision Metering Piston Pump
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit≤2.5% error at 1000 particles/mL
Output Interface4–20 mA analog output with configurable alarm relay
Data ReportingParticles per mL and ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPLD-GRS6
PriceUSD 6,700 (approx.)
Measurement PrincipleCoulometric Karl Fischer Titration
Measurement Range1 μg – 500 mg H₂O
Sensitivity0.1 μg
Accuracy±5% ±1 μg
Control SystemPULL T 8.0 Test Platform
Single-Test Duration2–4 min
Endpoint DetectionDual Platinum Electrodes
Titration Cell Volume150 mL
Stirring MethodMagnetic Stirrer
Power Supply220 V ±10%, 50 Hz ±0.5 Hz
Power Consumption40 W
Operating Temperature10–40 °C
Relative Humidity≤70%
Compliance StandardsGB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2+
PriceUSD 67,000 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Measurement Range1–450 µm (standard), 0.03–3000 µm (optional)
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2020, GB/T 18854, JJG 1061
Sensor Technology8th-Generation Dual-Laser Optical Particle Sensor
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Accuracy±3% typical (count), ±1% volumetric delivery
Coincidence Limit≤2.5% at 1000 particles/mL
Data Output4–20 mA analog interface,超标 alarm (customizable)
ReportingParticles per mL & ISO 4406 / NAS 1638 contamination codes
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC + iPad-compatible)
ComplianceFDA 21 CFR Part 11 ready (audit trail, electronic signature support), GLP/GMP-aligned workflow design
Display & Control10.1" capacitive touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic Instrument
ModelPSD-351B Microfiltration Membrane Filtration Tester
PriceUSD 1,600 (approx.)
Applicable StandardsSY/T 5329–2012, GB 11901–1989, GB/T 606–2003, GB/T 11133–2015, GB 7600–2008
Gas SourceNitrogen (user-supplied or optional integrated regulator)
Filter Diameterφ43 mm
Sample Volume Capacity3500 mL
Dimensions (W×D×H)≤500 × 500 × 800 mm
Construction MaterialsBorosilicate organic glass, 316 stainless steel, and corrosion-resistant polymer components
Temperature MonitoringDigital electronic thermometer (±0.5 °C accuracy)
Timing MethodPrecision digital stopwatch (0.01 s resolution)
Pressure ControlAdjustable inlet pressure regulator with dual-stage precision gauge (0–1.0 MPa range)
Filtration SystemIntegrated bubble-venting filter housing with standardized membrane support and sealing mechanism
Drain/Exhaust ValvesStainless steel needle valves with calibrated flow restriction
ComplianceDesigned for GLP-compliant suspended solids quantification in environmental and petroleum water quality labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2G
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Measurement Range0.1–0.5 µm (standard)
Resolution0.1 µm(c) minimum detectable size
Sampling Accuracy<±1%
Counting Accuracy±3% typical
Coincidence Limit≤2.5% at 1000 particles/mL
Output4–20 mA analog signal with configurable particle concentration alarm
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex spheres
SoftwareV8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI)
Power Input100–265 VAC, 50–60 Hz
ComplianceSupports GLP/GMP audit trails, ASTM F3290 (for semiconductor process liquids), USP <788> & <789> (for insoluble particle assessment in polymer solutions)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-259A
OriginShaanxi, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
Rated Power500 W
Operating Voltage220 V AC, 50 Hz
Temperature Control RangeTR+10 °C to 100 °C
Temperature Display Accuracy±0.2 °C
Separatory Funnel Capacity250 mL
Graduated Cylinders50 mL and 100 mL
Test Tube Diameter Compatibilityφ15–20 mm
pH Measurement Range0.00–14.00
pH Accuracy±0.1 pH
mV Range±1999 mV
mV Accuracy±10 mV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPCS-3A
ApplicationHandheld/Portable
Element Detection RangeC₅–Cₙ organic compounds
Quantification Range1–2000 (unitless relative scale)
Energy Resolution0.01 FU (Fluorescence Unit)
Repeatability≥99%
Detector TypeX-ray-excited ultraviolet fluorescence (XUVF) detector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2L
PriceUSD 31,800 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Obscuration
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Calibration StandardsJJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Spheres
Measuring Range1–450 µm
Customizable Sub-Ranges1–100 µm or 4–70 µm (c), down to 0.1 µm (c) resolution
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit≤2.5% error at 1000 particles/mL
Output4–20 mA analog signal with configurable alarm threshold
Data ReportingParticles per mL & ISO 4406 / NAS 1638 contamination codes
InterfaceColor LCD touchscreen + optional wireless keyboard/mouse
SoftwareV8.3 Integrated Analysis & Calibration Suite (PC & iPad-compatible)
Power Supply100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPSD-PF10A-0.5
Cleanliness ClassISO Class 4 (10 particles ≥0.1 µm per cubic foot)
Airflow Velocity0.25–0.6 m/s (adjustable)
Vibration Amplitude≤3 µm
Noise Level≤67 dB(A)
UV Sterilization Time15 min for microbial reduction
Operating Temperature10–30 °C
Relative Humidity≤75% RH
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-GS2
Drive TypeBelt-driven orbital motion
DisplayDigital speed & timer display
Speed Range30–300 rpm (adjustable)
Timer Range1–999 minutes
Platform Size300 × 300 mm
Load Capacity≤5 kg
Operating Noise<50 dB(A)
ConstructionStainless steel platform with corrosion-resistant frame
Clamp SystemStainless steel spring clamps (customizable for vials, flasks, tubes, microplates)
Power SupplyAC 220 V ±10%, 50 Hz
ComplianceCE-marked design principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-601
OriginShaanxi, China
Sensor Technology8th-Generation Dual-Laser Narrow-Beam Light Obscuration
Detection PrincipleLight Obscuration (LO) per USP <788>, EP 2.9.19, and ChP 0903
Measurement Range1–500 µm (optional extension to 0.03–3000 µm)
Channel Resolution1000 adjustable size channels (down to 0.01 µm resolution)
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow regulation
Accuracy±3% typical (per ChP 2020)
Coincidence Limit≤2.5% error at 1000 particles/mL
Calibration StandardsNIST-traceable latex spheres, ISO 21501-4, JJG 1061
Software ComplianceFDA 21 CFR Part 11, ALCOA+ principles, audit trail, electronic signature, 5-level user权限 management
Operating InterfaceTouchscreen + optional wireless keyboard/mouse
Sample Temperature Range0–80 °C
Ambient Operating Range−15–50 °C
Regulatory AlignmentCompliant with ChP 2015/2020, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, WHO IntPh IV, YBB00272004-2015, GB/T 11446.9-2013, ISO 4406, ISO 11171, NAS 1638, SAE AS4059, MIL-STD-1246, ASTM D6786, GB/T 18854, DL/T 432, and more
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDPC-2602
Price RangeUSD 140 – 39,500 (FOB)
Sensor Technology7th-Generation Dual-Laser Narrow-Beam Optical Detection
Particle Size ChannelsConfigurable Sets Including 0.3/0.5/1.0/2.5/5.0/10.0 µm
Counting Accuracy<5% coincidence error at 2×10⁶ particles/ft³
Flow Rate2.83 L/min (0.1 cfm)
Sampling TimeProgrammable (default 60 s)
Operating Temperature5–45 °C
Relative Humidity Limit≤90% RH (non-condensing)
BatteryRechargeable 4100 mAh Li-polymer
Display3.45″ industrial-grade full-view color LCD
Data Storage10,000 measurement records
ComplianceISO 14644-1:2015, GB/T 16292–1996, EU GMP Annex 1 (2022), USP <788>
Optional ModulesIntegrated temperature/humidity sensor (–40 to 120 °C / 0–100% RH), CO/HCHO electrochemical gas sensors
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelPLD-GRS6
PriceUSD 680 (FOB)
Measurement PrincipleCoulometric Karl Fischer Titration
Detection ElectrodeDual Platinum Electrodes
Control SystemPULL T 8.0 Embedded Microcontroller Platform
Measurement Range1 µg – 30 mg H₂O (standard mode)
Sensitivity0.1 µg H₂O
Accuracy±5% relative or ±1 µg absolute, whichever is greater
Sample TypesLiquids, Gases, Solids (with optional oven adapter)
Titration Cell Volume150 mL
Stirring MechanismIntegrated Magnetic Stirrer
Display20×2 Character LCD with real-time clock, electrolysis rate (µg/s), and endpoint status
Endpoint DetectionDual-platinum amperometric detection
OutputBuilt-in thermal printer (16-character line, auto-print of parameters and results)
Power Supply220 V ±10%, 50 Hz ±0.5 Hz
Power Consumption40 W
Operating Temperature10–40 °C
Relative Humidity≤70% RH
Compliance StandardsGB/T 7600, GB/T 11133, GB/T 6283, SH/T 0207, SH/T 0246, SH/T 0255
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2
PriceUSD 67,500 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Piston Pump + High-Accuracy Electromagnetic Flow Regulation
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368-2018
Measurement Range0.1–0.5 µm and 0.1–1.0 µm (standard)
Sampling Accuracy<±1%
Counting Accuracy±3% typical
Coincidence Limit≤2.5% error at 1000 particles/mL
Output Interface4–20 mA analog output with programmable alarm thresholds
Data AcquisitionIntegrated iPad-compatible wireless data capture
SoftwarePULUODY V8.3 Particle Analysis & Calibration Separation Platform (PC + embedded GUI)
DisplayColor LCD touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelPLD-MPCS2.0
PriceUSD 50,000 (FOB)
Measurement PrincipleBrightfield Microscopy + Digital Image Analysis
ComplianceChinese Pharmacopoeia ChP 0903 Method 2 (Microscopic Particle Counting), USP <788>, USP <789>, EP 2.9.19, ISO 21501-4, ISO 21510, GB/T 11446.9-2013
Particle Detection Range1–500 µm
Magnification40×–1000×
Resolution0.1 µm
Repeatability Error<5% (excluding sample preparation variability)
CCD Sensor3 MP monochrome digital camera
Calibration TraceabilityNorthwest Metrology & Testing Center (Civil Products)
Software PlatformWindows 2000/XP compatible
InterfaceRS-232 or USB 2.0
Automatic Field StitchingFull membrane scan with seamless mosaic generation
Particle Segmentation Speed<1 s per image
Segmentation Success Rate>93%
Accuracy±3% typical (ChP 2020 reference calibration)
Coincidence Limit10,000 particles/mL (5% coincidence error)
Resolution Performance>95% (ChP 2020), <10% false-negative rate (USP/ISO 21501-4)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPGS-OC1
PriceUSD 3,950 (FOB)
Measurement PrincipleElectrochemical (Galvanic Cell)
Range0.0–10 / 100 / 1000 ppm O₂ (selectable)
Accuracy≤ ±2% FS
Sample Flow Rate400 ± 10 mL/min
Inlet Pressure Range0.05–0.5 MPa
Response Time (T₉₀)≤ 60 s
Display128×64 OLED, monochrome, high-brightness
Data Storage3200 records with trend curve
Power SupplyAC 220 V ±10%, 50 Hz ±10% (charger)
Built-in Sampling PumpYes
Operating Temperature–5 °C to +45 °C
Operating Humidity≤ 90% RH (non-condensing)
Alarm OutputUser-configurable threshold (factory default: 5 ppm O₂)
ComplianceDesigned for ISO 8573-3, ASTM D6299, and GLP-aligned field verification workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-6010
OriginShaanxi, China
Detection PrincipleLight Obscuration (LO) / Dual-Laser Narrow-Beam Particle Counting
Sensor Generation8th-Generation Dual-Laser Narrow-Beam Sensor
Measurement Range1–500 µm (optional 0.03–3000 µm)
Channel Resolution1000 customizable channels (down to 0.01 µm bin width)
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow control system
Sample Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Accuracy±3% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤2.5% at 1000 particles/mL
Resolution>95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated)
Temperature Range (fluid)0–80 °C
Environmental Operating Temp−15–50 °C
ComplianceFDA 21 CFR Part 11 (audit trail, e-signature, 5-level user权限, data backup/recovery, power-fail protection), GLP/GMP-ready
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex spheres
Regulatory AlignmentChP 2015/2020 <0903>, USP <788>/<789>/<797>, EP 10.0/9.0, BP 2019, JP 17, WHO IntPh IV, YBB 00272004-2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, ASTM D6786
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-GS2
TypeOrbital Shaker
DisplayLED Digital Speed & Timer
Drive MechanismEccentric Cam with Belt-Driven Motion
Platform Size300 × 300 mm (standard)
Speed Range30–300 rpm
Speed Accuracy±1 rpm
Timer Range1–999 min
Platform Load Capacity≤5 kg
Noise Level≤50 dB(A)
ConstructionPowder-Coated Steel Frame with Stainless Steel Platform
ComplianceCE, ISO 9001, GB/T 12803–2021 (Laboratory Equipment – Orbital Shakers)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Instrument TypeMulti-Channel Atomic Fluorescence Spectrometer
Sample IntroductionDirect Nebulization
Waste DisposalRear Exhaust Design
Gas Flow ControlRotameter-Based Pneumatic System
Detectable ElementsAl, Ba, B, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, P, Si, Ag, Na, Sn, Ti, V, Zn, K, Li, Sb, Sr, Bi, As, In, Zr, W, Co, Ce
Relative Standard Deviation (RSD)<1%
Linear Dynamic Range5 orders of magnitude (0.01–10,000 µg/L)
Detection LimitsSub-ppb (≤0.01 µg/L) for most elements
Photomultiplier Tube Wavelength Range200–1000 nm
Atomizer Temperature Control RangeAmbient to 45 °C
Optical Resolution≤0.015 nm
RF Generator Frequency27.12 MHz (stability ≤0.05%)
RF Power Output800–1600 W (stability ≤0.2%)
Grating Density2400 lines/mm
Grating Area80 × 110 mm
Sample Volume Requirement>1 mL
Operating Temperature15–45 °C
Operating Humidity0–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2DR
Detection PrincipleDual-Laser Narrow-Beam Light Obscuration
Detection Range0.5–20.0 µm (standard)
Sensor Generation8th-Generation Dual-Laser Obscuration Sensor
Sampling MethodPrecision Metering Piston Pump + Electromagnetic Flow Control
Accuracy±3% typical
Volume Accuracy<±1%
Coincidence Limit≤2.5% error at 1000 particles/mL
Data Output4–20 mA analog interface with configurable particle concentration alarm
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex spheres
SoftwareV8.3 Integrated Analysis & Calibration Software (PC & tablet-compatible)
Display & ControlColor LCD touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-FX-801
Detection PrincipleDual-mode (Light Obscuration + Light Scattering)
Sensor Generation8th-generation dual-laser collimated beam sensor
Measuring Range0.5–100.0 µm
Customizable Channels1–100 µm or 4–70 µm (c), down to 0.1 µm (c)
Sampling Accuracy<±1%
Counting Accuracy±3% typical
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Flow ControlPrecision metering pump
Output4–20 mA analog interface with configurable alarm
Calibration StandardsJJG 1061, ISO 21501-2, NIST-traceable latex spheres
SoftwareV8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI)
Compliance SupportGLP/GMP audit trail, FDA 21 CFR Part 11 ready (optional configuration)
Power Input100–265 VAC, 50–60 Hz