Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelPS8011+
Price RangeUSD 135 – 525
Material OptionsPP, PE, PFA, PEEK, PFAD, High-Silica Borosilicate Glass
Volume Options50 mL to 1000 mL
Particle Cleanliness LevelRCL < 15 particles per 100 mL
Certified Cleanliness ClassesISO Class 1–9 (per ISO 14644-1)
Particle Detection Thresholds0.1 µm, 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm
Average Outgoing Quality Limit (AOQL)0.5%
Compliance StandardsISO 3722, ISO 14644-1, GB/T 17484, GB 50073-2001, JIS B9925:1997, JIS K0554:1995
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2801
Detection PrincipleDual-laser light scattering (narrow-beam, 8th-generation)
Particle Size Range0.1–0.5 µm (standard)
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% at 1000 particles/mL
Flow ControlPrecision piston pump + electromagnetic flow regulation
ComplianceUSP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061
Data Output4–20 mA analog interface
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI)
Operating InterfaceColor LCD touch screen + optional wireless keyboard/mouse
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2DN
PriceUSD 75,000 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Plunger Pump + Electromagnetic Flow Regulation
Calibration StandardsJJG 1061, ISO 21501-4, Polystyrene Latex (PSL) Reference Standards
Detection Range0.1–0.5 µm (standard)
Customizable1–100 µm or 4–70 µm (c)
Minimum Detectable Size0.1 µm (c)
Sampling Accuracy< ±1%
Measurement Accuracy< ±3% (typical)
Coincidence Limit≤2.5% at 1000 particles/mL
Output Interface4–20 mA analog output
Alarm FunctionConfigurable particle concentration threshold alert
Data ReportingParticles per mL + ISO 4406 / NAS 1638 contamination code
Power Input100–265 VAC, 50–60 Hz
Display & ControlColor LCD touchscreen + optional wireless keyboard/mouse
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC & embedded)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2LS
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Detection Range0.1–0.5 µm (standard)
Sampling MethodPrecision Metering Piston Pump
Flow ControlDual-Stage Electromagnetic + Precision Piston Pump
Accuracy±3% typical
Volume Accuracy±1%
Coincidence Limit≤2.5% error at 1000 particles/mL
Output4–20 mA analog interface with programmable contamination alarm
ReportingParticles per mL & ISO 4406 / NAS 1638 / SAE AS4059 contamination codes
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex spheres
SoftwareV8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen UI)
DisplayColor LCD touch interface + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for ISO Class 1–5 cleanroom environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Measurement Range0.03–3000 µm (configurable sensor modules)
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Accuracy±3% typical
Counting ResolutionCustomizable channels (e.g., 1–100 µm, 4–70 µm(c), 0.1 µm(c))
Coincidence Limit≤2.5% error at 1000 particles/mL
Sampling Precision<±1%
Output4–20 mA analog signal
AlarmConfigurable particle concentration threshold alert
Data InterfaceiPad-compatible wireless acquisition
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC & touchscreen)
ComplianceSupports 21 CFR Part 11 audit trail (optional configuration), GLP/GMP traceability mode
Power Input100–265 VAC, 50–60 Hz
Application ModeOnline continuous monitoring & offline portable/fixed sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2-C
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Measuring Range0.05–0.2 µm, 0.1–0.5 µm (standard)
Sampling MethodPrecision Metering Piston Pump + Electromagnetic Flow Control
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Output Interface4–20 mA analog output
Alarm FunctionConfigurable particle concentration threshold alert
Data ReportingParticles per mL & ISO 4406 / NAS 1638 contamination code
Compliance StandardsJJG 1061, ISO 21501-4, USP <788>, EP 2.9.19
Software PlatformV8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI)
Power Input100–265 VAC, 50–60 Hz
DisplayColor LCD touchscreen + optional wireless keyboard/mouse