- All
- Favorite
- Popular
- Most rated
| Brand | NanoMEGAS |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | DigiSTAR |
| Pricing | Upon Request |
| Brand | Quantum Detectors |
|---|---|
| Origin | United Kingdom |
| Model | Quantum C100 |
| Frame Rate | 2000 fps (continuous) |
| Pixel Array | 2048 × 2048 |
| Readout | Fiber-optic coupled direct electron detection |
| Interface | GUI-controlled, open-format data export (TIFF, MRC, HDF5) |
| Compatibility | Optimized for 100 keV transmission electron microscopes |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Sigray |
|---|---|
| Origin | Shanghai, China |
| Model | TriLambdaXRM-30 |
| Spatial Resolution | 35 nm (at 1.7 keV) |
| X-ray Energy Range | 1.7–8.04 keV |
| Max. Number of Selectable Anode Targets | 3 (e.g., Si, Cr, Fe, Cu) |
| Source Type | Patented Multi-Target Reflective X-ray Source with Diamond Heat Sink |
| Optical Configuration | Triple Parabolic X-ray Optics + Fresnel Zone Plate Objective Lens |
| Phase Ring | Zernike Phase-Shifting Ring |
| Reconstructed Volume Resolution | Down to 65 nm voxel (LFOV mode) |
| Field of View (LFOV) | 65 µm diameter |
| FOV (HR mode) | ~10–20 µm |
| Reconstruction Software | GigaRecon (iterative CBCT reconstruction, <45 s for 2048×2048×2200 dataset) |
| Acquisition Software | Sigray3D with AI-assisted AutoPilot & Sample Handling Robot (SHR) integration |
| Control Architecture | Dual-Workstation (Windows GUI + Linux real-time EPICS-based control) |
| Dimensions | 2.3 m (L) × 1.3 m (W) × 1.5 m (H) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Sigray |
|---|---|
| Origin | USA |
| Model | QuantumLeap-V210 |
| Energy Range | 1.7–10 keV |
| XAS Modes | Transmission |
| XANES Resolution | ≤0.7 eV |
| EXAFS Resolution | <10 eV |
| Beam Spot Size | 100 µm (diameter) |
| Vacuum Level | <10⁻⁵ Torr |
| X-ray Source | Patented Multi-Target Microfocus Source (W & Mo anodes, 300 W, 20–50 kV) |
| Focusing Optics | Dual-Parabolic Capillary Lens (Pt-coated, ~80% transmission, 1:1 magnification) |
| Analyzer Crystals | HAPG/HOPG, Ge(111), Ge(220), Ge(400) |
| Detector | Spatially Resolved Photon-Counting Detector |
| Sample Capacity | Up to 16 × 3 mm diameter samples |
| Dimensions | 107 cm W × 241 cm H × 191 cm D |
| Brand | Sigray |
|---|---|
| Origin | Shanghai, China |
| Model | AttoMap-310 |
| Spatial Resolution (with high-res optics) | 3–5 µm |
| Detection Sensitivity | sub-ppm (relative), femtogram-level (absolute) |
| Incident Angle Range | 3° to 90° (0.01° step) |
| X-ray Source | Patented microfocus source with up to 5 selectable anode targets (e.g., Si, Cr, Cu, Rh, Mo, W, Au, Ti, Ag) |
| Max Power / Voltage | 50 W / 20–45 kVp |
| X-ray Optics | Dual-parabolic grazing-incidence mirrors, ~80% transmission efficiency, 1:1 default magnification |
| Detector | Silicon Drift Detector (SDD), energy resolution <129 eV (Mn-Kα) |
| Vacuum Chamber | <10⁻⁴ Torr |
| Sample Stage Travel | 100 × 100 mm |
| Light Element Detection Limit | Down to boron (B), quantitative for C, N, O at <1% wt. |
| Brand | VitroTEM |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Naiad |
| Pricing | Available Upon Request |
| Brand | SIGRAY |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | APEX Hybrid |
| Pricing | Upon Request |
| Brand | Sigray |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eclipse-900 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Spatial Resolution | 300 nm (achievable voxel size <10 nm) |
| Working Distance Resolution (50 mm) | <700 nm |
| X-ray Source | 160 kV Ultra-Bright Nanofocus Source with Multi-Target Spectral Contrast Option (W/Diamond substrate |
| Detector | High-Efficiency High-Resolution Flat-Panel Detector (Standard: 6.7 MP, 50 µm pixel |
| Optional | 13 MP or 23 MP) |
| Stage | Standard Air-Bearing Rotary Stage (XYZ travel: 100 × 40 × 100 mm) |
| Optional Motorized Stage (XYZ | 50 × 100 × 50 mm) |
| Imaging Modes | Phase-Contrast Imaging, Phase Retrieval, Offset Scanning, Helical Scan |
| Brand | Quantum Detectors |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MERLIN T4 |
| Pricing | Upon Request |
| Brand | NanoMEGAS |
|---|---|
| Origin | Belgium |
| Model | ADT-3D |
| Compatible TEM Voltage | 120–300 kV |
| Compatible Sources | LaB6, W, FEG |
| Minimum Crystal Size (Organic) | ~100 nm |
| Minimum Crystal Size (Inorganic) | ~20 nm |
| Tilt Range (Cell Parameter Determination) | −15° to +15°, 1° step |
| Recommended Tilt Range (Structure Solution) | −45° to +45°, 1° step or continuous rotation (MicroED) |
| Data Acquisition Modes | Manual or automated PED |
| Detector Compatibility | CCD cameras ≥1k × 1k resolution |
| Sample Holder Support | Single-tilt, tomography, cryo holders |
| Output | 3D reciprocal space reconstruction, unit cell parameters (2–5% error), space group assignment, integrated 3D reflection intensities |
| Compliance | Fully compatible with standard TEM workflows under GLP-aligned data handling practices |
| Brand | NanoMEGAS |
|---|---|
| Origin | Belgium |
| Model | ASTAR® |
| Compatibility | 120–300 kV TEM (including Cs-corrected FEG-TEM) |
| Spatial Resolution | 1–4 nm (FEG-TEM), <10 nm (LaB₆ TEM) |
| Acquisition Speed | Up to >1000 fps (with direct electron detectors) |
| PED Tilt Angle Range | 0.2°–2.5° |
| Output Data Types | Orientation Maps, Phase Maps, Correlation Index, Confidence Index, Virtual BF/DF Images, Grain Boundary Networks, Pole Figures, Strain-Compatible Integration (with TopSPIN) |
| Compliance | Fully compatible with GLP/GMP workflows requiring audit trails |
| Brand | Quantum Detectors |
|---|---|
| Origin | United Kingdom |
| Model | MerlinEELS |
| Detector Architecture | Hybrid Pixel (4 × Medipix3 RX chips) |
| Format | 1024 × 256 pixels |
| Frame Rate | up to 3600 fps (6-bit mode, full frame) |
| Dynamic Range | >16 million counts per pixel |
| Readout Noise | 0 e⁻ rms |
| Dead Time | 0 ns (dual counter per pixel) |
| Pixel Size | 55 µm |
| Energy Thresholding | User-configurable single-electron discrimination |
| ROI Modes | 4–128 rows selectable (N × 256 px) |
| Integration | TEM-compatible with dedicated scan generator and multi-signal synchronization |
| Brand | Quantum Detectors |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MerlinEM |
| Pricing | Available Upon Request |
| Detector Material | 500 µm thick silicon |
| Detector Type | Reverse-biased hybrid silicon diode array |
| Pixel Size | 55 × 55 µm |
| Active Area | 1R (single chip): 14 × 14 mm² |
| 4R/4S (quad-chip) | 28 × 28 mm² |
| Pixel Count | 1R: 256 × 256 |
| 4R/4S | 512 × 512 |
| Readout Noise | Effectively 0 e⁻ (threshold-based discrimination) |
| Signal-to-Noise Ratio (SNR) | 107:1 |
| Detective Quantum Efficiency (DQE) at 60 keV | 1.0 (zero frequency), 0.45 (Nyquist frequency) |
| Modulation Transfer Function (MTF) at 60 keV | >0.62 at Nyquist frequency (mode-dependent) |
| Frame Rate (full-frame, continuous) | 18,800 fps (1-bit), 3,600 fps (6-bit), 1,800 fps (12-bit), 800 fps (24-bit) |
| Region-of-Interest (ROI) readout | up to 7,200 fps (128 × 256, 6-bit), 14,400 fps (64 × 256, 6-bit) |
| Inter-frame gap time | 0 µs |
| Dynamic Range | Up to 24-bit per pixel (16,777,216 counts/pixel) |
| Trigger Interface | 3.3 V / 5 V TTL pulse or software-controlled via TCP/IP |
| Energy Range | 30–300 keV |
| Software Suite | 4D STEM acquisition platform, LabVIEW drivers, GM3 integration interface, native TCP/IP communication |
| Mounting Options | Side-insertion retractable or bottom-fixed configuration |
| Optional Integration | NanoMEGAS precession electron diffraction (PED) interface |
| Brand | Sigray |
|---|---|
| Origin | Shanghai, China |
| Model | EclipseXRM-910 |
| Spatial Resolution | 0.3 µm |
| Voxel Size | <30 nm |
| Working Distance Capability | Sub-micron resolution at ≥100 mm sample diameter |
| X-ray Source | Dual-source configuration — 160 kVp nanofocus tungsten source (diamond substrate) + optional Multi-Spectral Source (MSS) with up to 7 selectable anode materials (Cr, Cu, Rh, Mo, Ag, Ti, Au, W) |
| Detector Configuration | Dual-detector system — 6.7 MP HyperCapture-Pro CMOS (upgradable to 13 MP or 27 MP) + 16 MP UltraVision-HDX CMOS |
| Reconstructive Software | GigaRecon (FDK & iterative reconstruction |
| Acquisition Software | Sigray3D with AI-assisted AutoPilot and robotic sample handling (up to 20 samples) |
| Phase Contrast Imaging | Enabled natively via propagation-based phase retrieval |
| Compliance Framework | Designed for GLP/GMP-aligned workflows |
| Operating Environment | Dual-workstation architecture — Windows GUI + real-time Linux control kernel (EPICS-compatible) |
| Brand | Sigray |
|---|---|
| Origin | Shanghai, China |
| Model | APEX XCT-150 |
| X-ray Source | Sealed-tube nanofocus transmission source (30–160 kVp, 25 W, tungsten target) |
| Spatial Resolution | 0.5 µm (uncompromised across full 300 mm diameter field of view) |
| Minimum Voxel Size | 70 nm |
| Detector | 6.7 MP, 50 µm pixel pitch, 9 FPS, 14 × 11 cm active area |
| Optical Alignment Camera | 16 MP visible-light camera |
| Software Suite | Sigray3D acquisition platform + GigaRecon iterative reconstruction engine |
| Reconstruct Speed | <45 s for 2048 × 2048 × 2200 dataset |
| Sample Handling | Automated Sample Handling Robot (SHR), supports up to 20 samples per batch |
| Motion Stage | XYZ travel 100 × 100 × 20 mm (customizable extension available) |
| System Dimensions | 2.24 m (L) × 1.24 m (W) × 2.34 m (H) |
| Operating Systems | Dual-station architecture — Windows-based GUI workstation + Linux-based real-time control workstation (EPICS-compatible) |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Quantum Detectors |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CheeTah T3 EELS |
| Pricing | Available Upon Request |
| Brand | NanoMEGAS |
|---|---|
| Origin | Belgium |
| Model | TOPSPIN |
| Application | Precession Electron Diffraction (PED)–Enabled 4D-STEM Acquisition |
| Integration | DigiSTAR Beam Control & Direct Electron Detection |
| Compliance | TEM/STEM-Compatible with ASTAR & STRAIN Software Ecosystem |
| Brand | NanoMEGAS |
|---|---|
| Origin | Belgium |
| Model | TopSPIN STRAIN |
| Application | Automated High-Resolution Strain Mapping in Scanning Transmission Electron Microscopy (STEM) using 4D Scanning Precession Electron Diffraction (4D-SPED) |
| Spatial Resolution | 2–3 nm (FEG-TEM) |
| Strain Sensitivity | < 2 × 10⁻⁴ |
| Typical Acquisition Time | 5–10 min (150 × 150 pixels) |
| Pixel Dwell Time | 10–40 ms |
| Strain Quantification Accuracy | ±0.02% (at 200 kV FEG-TEM) |
| Analysis Engine | AppFive proprietary algorithm |
| Output Modalities | Point, line, and 2D strain tensor maps (εₓₓ, ε_zz, ε_xz), orientation/phase/strain/STEM co-registration |