- All
- Favorite
- Popular
- Most rated
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210K |
| Maximum Load Capacity | 2000 N |
| Force Sensor Accuracy | ±0.01% FS |
| Test Accuracy | Class 0.5 |
| Repeatability | ≤0.5% |
| Displacement Accuracy | ≤0.2% |
| Deformation Accuracy | ≤0.2% |
| Test Speed Range | 0.01–300 mm/min |
| Compliance | GB/T 6344–1996, GB/T 10807–2006, GB/T 20467–2006 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S |
| Max. Test Load | 20 kN |
| Platen Dimensions | 420 mm × 420 mm |
| Load Accuracy | ±0.5% of full scale |
| Force Resolution | 1/500,000 FS |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Accuracy | ±0.5% of set value |
| Displacement Resolution | 0.048 µm |
| Displacement Accuracy | ±0.5% of set value |
| Data Acquisition Rate | Up to 1000 Hz |
| Closed-Loop Control Frequency | 1000 Hz |
| Crosshead Speed Range | 1×10⁻⁷ – 1×10⁻³ mm/min (infinitely variable) |
| Test Width | 420 mm |
| Heating Power | 2000 W |
| Temperature Stability | ±1 °C |
| Temperature Accuracy | ±0.2 °C |
| Overall Dimensions (W×D×H) | 775 × 660 × 1740 mm |
| Motor Power | 750 W |
| Net Weight | 280 kg |
| Safety Features | Overload protection, mechanical travel limit, voltage overload protection |
| Compliance | Meets ISO 7500-1 Class 0.5, ASTM E4, ASTM D695, ISO 604, GB/T 228.1, GB/T 1041 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJYL872 |
| Price | USD 4,200 (FOB Shanghai) |
| Maximum Test Force | 300 kN |
| Force Loading Rate | 0–10 kN/s |
| Platen Spacing | Customizable |
| Platen Dimensions | Customizable |
| Flexural Test Capacity | 10 kN |
| Flexural Loading Rate | 0–0.075 kN/s |
| Relative Indication Error | ±1.0% |
| Compliance Standards | GB/T 17671–1999, GB 13544–2000, GB/T 50081–2002 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210K Sponge-Specific |
| Max Test Force | 2 kN |
| Load Rate Range | 0.01–300 mm/min |
| Platen Spacing | 500 mm |
| Platen Dimensions | 300 mm × 300 mm |
| Compliance | GB/T 10807–2006, GB/T 6344–1996, GB/T 20467–2006 |
| Force Sensor Accuracy | ±0.01% FS |
| Force Measurement Class | 0.5 |
| Repeatability | ≤0.5% |
| Displacement Accuracy | ≤0.2% |
| Deformation Accuracy | ≤0.2% |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | Qingji YL-2000 / YL-3000 |
| Max Load Capacity | 2000 kN / 3000 kN |
| Accuracy Class | Class I (per ISO 7500-1 & ASTM E4) |
| Force Range | 10–2000 kN / 10–3000 kN |
| Loading Rate | 1–15 mm/s (adjustable, closed-loop servo-controlled) |
| Internal Clearance (between platens) | 320 mm |
| Platen Dimensions | 320 × 320 mm or 400 × 400 mm |
| Motor Power | 0.75 kW / 1.1 kW / 2.2 kW |
| Net Weight | 1000 kg / 1500 kg |
| Overall Dimensions (W×D×H) | ~520×450×1350 mm or ~700×540×1800 mm |
| Control System | PC-based servo-hydraulic or electromechanical closed-loop control with real-time data acquisition |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211H |
| Max. Test Load | 30 kN |
| Platen Dimensions | 1000 mm × 1000 mm |
| Platen Spacing | 1000 mm |
| Accuracy Class | 0.5 |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Effective Test Width | 320 mm |
| Travel Range | 500 mm (extendable to 800 mm) |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement & Deformation Accuracy | ±0.5% of indicated value |
| Control System | Panasonic full-digital AC servo controller |
| Software | Full-closed-loop digital control system supporting constant-force, constant-strain, and constant-displacement modes |
| Safety Protection | Automatic overload cutoff at 110% FS, electronic limit switches, real-time software diagnostics |
| Power | 2–5 kW |
| Net Weight | ~145 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJ211H |
| Price | USD 7,900 (FOB Shanghai) |
| Max Test Load | 30 kN |
| Load Rate Range | 0.01–300 mm/min |
| Platen Spacing | 500 mm (extendable to 800 mm) |
| Platen Dimensions | 500 mm × 500 mm (optional 800 mm × 800 mm) |
| Load Cell Accuracy Class | 0.5 |
| Force Resolution | 1 part in 500,000 full scale (no internal range switching) |
| Effective Test Width | 320 mm |
| Crosshead Travel | 500 mm (extendable to 800 mm) |
| Speed Accuracy | ±0.5% of set value |
| Displacement & Deformation Measurement Accuracy | ±0.5% of reading |
| Load Sensing | High-precision strain-gauge transducer (USA-sourced) |
| Control System | Panasonic全数字 AC servo controller |
| Control Mode | Full-digital closed-loop control supporting constant load, constant strain, and constant displacement protocols |
| Vertical Positioning | Dual-speed (fast/slow) motorized crosshead with manual override |
| Safety Protection | Software-based overload diagnosis, electronic limit switches, automatic shutdown at >110% of rated load |
| Return Function | Manual rapid return or programmable auto-return post-test |
| Fixture Customization | Application-specific compression platens and restraining fixtures available upon request |
| Power Requirement | 2–5 kW, 3-phase AC |
| Net Weight | ~145 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | QJYL872 |
| Price | USD 4,950 (FOB Shanghai) |
| Max. Compression Load Capacity | 300 kN |
| Flexural Load Capacity | 10 kN |
| Load Application Rate (Compression) | 0–10 kN/s |
| Load Application Rate (Flexure) | 0–0.075 kN/s |
| Maximum Platen Spacing | 500 mm |
| Platen Dimensions | Customizable per application requirement |
| Indicated Relative Error | ±1.0% |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJYL-2000 / QJYL-3000 |
| Max Load Capacity | 2000 kN / 3000 kN |
| Accuracy Class | Class I (per GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 20–2000 kN / 10–3000 kN |
| Loading Rate Adjustment | 1–15 mm/s (motor-driven, stepless control) |
| Internal Clearance (between platens) | 320 mm |
| Platen Dimensions | 320 × 260 mm or 350 × 300 mm |
| Motor Power | 0.75 kW / 1.1 kW / 1.5 kW (3-phase, 380 V, 50 Hz) |
| Net Weight | ~800 kg |
| Overall Dimensions (W×D×H) | ~850 × 500 × 1480 mm |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL872 |
| Maximum Test Force | 200 kN |
| Compressive Force Range | 0–200 kN |
| Flexural (3-Point Bending) Force Capacity | 10 kN |
| Load Rate Control Range (Compression) | 0–10 kN/s |
| Load Rate Control Range (Flexure) | 0–0.075 kN/s |
| Indicated Relative Error | ±1% |
| Compliance Standards | GB/T 17671–1999, GB 13544–2000, GB/T 50081–2002 |
| Application Scope | Cement mortar, concrete cubes, fired bricks, autoclaved aerated concrete blocks, structural ceramics, and metallic components |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211H-30KN |
| Max. Test Force | 30 kN |
| Platen Dimensions | 1000 mm × 1000 mm |
| Platen Spacing | 1000 mm |
| Load Cell Accuracy Class | 0.5 |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Effective Test Width | 1000 mm |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement & Deformation Accuracy | ±0.5% of reading |
| Load Sensing | High-precision U.S.-sourced load cell |
| Control System | Panasonic full-digital AC servo controller |
| Software | Full-closed-loop digital control system supporting constant-force, constant-strain, and constant-displacement modes |
| Safety Protection | Electronic limit switches, software-based overload diagnosis (10% over capacity), automatic return post-test |
| Power | 2–5 kW |
| Net Weight | ~145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A |
| Max Test Load | 50 kN |
| Load Application Rate | 1 kN/s (adjustable) |
| Platen Spacing Adjustment Range | 1 mm resolution |
| Platen Dimensions | 590 mm (L) × 355 mm (W) |
| Overall Dimensions | 590 × 355 × 1640 mm |
| Weight | ~85 kg |
| Load Cell Accuracy Class | 0.5 |
| Effective Test Width | 150 mm |
| Vertical Travel | 800 mm |
| Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Load Resolution | 500,000 counts (single-range, no auto-ranging) |
| Force Units | gf, kgf, N, kN, lbf |
| Control System | Panasonic full-digital AC servo controller |
| Load Cell | High-precision U.S.-sourced strain-gauge sensor |
| Safety Features | Software-based overload diagnosis, electronic limit switches, 110% over-load protection |
| Return Mode | Manual or programmable automatic return to initial position |
| Power Supply | 200 V AC, 400 W |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL872A-200KN |
| Max. Test Load | 200 kN |
| Load Application Rate | 500 N/s |
| Platen Dimensions | 260 mm × 260 mm |
| Platen Spacing | 260 mm |
| Accuracy | ±0.5% of full scale |
| Load Rate Range | 0–2.4 kN/s (±200 N/s) |
| Column Spacing | 310 mm |
| Screw Travel | 100 mm |
| Catalyst Compression Fixture | 250 mm × 250 mm |
| Power Consumption | 0.75 kW |
| Supply Voltage | 220 V AC |
| Dimensions (W×D×H) | 730 mm × 600 mm × 1426 mm |
| Weight | 450 kg |
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJYL872 |
| Max. Compression Load Capacity | 300 kN |
| Max. Flexural Load Capacity | 10 kN |
| Load Application Rate (Compression) | 0–10 kN/s |
| Load Application Rate (Flexure) | 0–0.075 kN/s |
| Relative Indication Error | ±1% |
| Platen Spacing | Customizable |
| Platen Dimensions | Customizable |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJYL3000KN |
| Max. Test Load | 3000 kN |
| Loading Rate | 1–15 mm/s (adjustable) |
| Platen Spacing (clear height) | 320 mm |
| Platen Dimensions | 320 × 320 mm or 400 × 400 mm |
| Accuracy Class | ISO 7500-1 Class I |
| Control System | Servo-controlled hydraulic actuation with PC-based closed-loop feedback |
| Compliance | ASTM C39/C109/C140, ISO 7500-1, GB/T 7742-2008, JGJ/T 70-2009 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL872A |
| Max. Test Load | 3000 kN |
| Load Application Rate | 0–2.4 kN/s ±200 N/s |
| Platen Spacing | 260 mm |
| Platen Dimensions | 250 × 250 mm |
| Accuracy Class | Class I (per ISO 7500-1 & GB/T 3159) |
| Force Measurement Range | 10–3000 kN |
| Crosshead Speed | 1–15 mm/s (adjustable) |
| Motor Power | 0.75 / 1.1 / 2.2 kW |
| Net Weight | 1000–1500 kg |
| Overall Dimensions | Approx. 520×450×1350 mm or 700×540×1800 mm |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJWE-Series |
| Max. Test Load | 2000 kN |
| Load Application Rate | 1.5 (kN/s, typical default setting) |
| Platen Spacing | Customizable |
| Platen Dimensions | Customizable |
| Accuracy | ±0.5% of full scale |
| Resolution | ≤0.5% of full scale |
| Compression Space | 480–510 mm |
| Tensile Space | 480–610 mm |
| Round Specimen Grip Range | φ10–70 mm (by model) |
| Flat Specimen Grip Range | 0–40 mm (by model) |
| Piston Stroke | 150–170 mm |
| Bend Support Span | 100–500 mm |
| Shear Specimen Diameter | φ10–30 mm |
| Motor Power | 1.5 kW or 2.1 kW, 3-phase |
| Dimensions (L×W×H) | 800×520×1850 to 950×650×2220 mm |
| Weight | 1650–2500 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL-2000 / QJYL-3000 |
| Max Load Capacity | 2000 kN / 3000 kN |
| Accuracy Class | Class I (per ISO 7500-1 & ASTM E4) |
| Force Range | 10–3000 kN |
| Loading Speed | 1–15 mm/s (adjustable) |
| Internal Clear Distance | 320 mm |
| Compression Platens | 320 × 320 mm or 400 × 400 mm |
| Motor Power | 0.75 / 1.1 / 2.2 kW |
| Net Weight | 1000 kg / 1500 kg |
| Overall Dimensions | ~520 × 450 × 1350 mm or 700 × 540 × 1800 mm |
Show next