| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Qinji XDW3541 |
| Price | USD 9,200 (FOB Shanghai) |
| Xenon Lamp Power | 6 kW |
| Temperature Range | RT+10°C to 80°C ±1°C (customizable upper limit available) |
| Humidity Range | Not applicable (condensation-based moisture simulation only) |
| Spectral Range | 290–800 nm |
| Irradiance at 340 nm | 0.35–1.50 W/m²/nm (adjustable, calibrated per ISO 4892-2) |
| Lamp Life | ~2,000 h (typical, dependent on operating conditions and power cycling) |
| Sample Rotation Speed | 5 rpm |
| Sample Holder Radius (inner/outer) | 100 / 220 mm |
| Center-to-Sample Distance | 165 mm |
| Chamber Interior Dimensions | 500 × 500 × 600 mm (L×W×H) |
| Rainfall Duration | 0–9999 min (programmable) |
| Rainfall Interval | 0–240 min (programmable) |
| Cooling Method | Hybrid air/water-cooled lamp system (3 kW air-cooling + 4.5 kW water-cooling) |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK-562A |
| Chamber Type | Upright |
| Cooling Method | Air-cooled |
| Temperature Range | -40 °C to +150 °C |
| Humidity Range | 30–98 %RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high temp), ±2 °C (low temp) |
| Humidity Uniformity | ≤ ±2 %RH |
| Humidity Fluctuation | ±2 %RH |
| Internal Dimensions (W×D×H) | 450×400×350 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.0 kW |
| Net Weight | ~180 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJCK Rapid Temperature Change Test Chamber |
| Price | USD 7,000 (FOB Shanghai) |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJXDW3541 |
| Lamp Power | 4.5 kW (water-cooled) |
| Temperature Range | RT+10°C to 80°C ±1°C |
| Humidity Range | Not specified (condensation-based humidity simulation only) |
| Spectral Range | 290–800 nm |
| Radiant Intensity | 550 W/m² (300–800 nm) |
| Sample Rotation Speed | 5 rpm |
| Chamber Interior Dimensions | 500 × 500 × 600 mm |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Lamp Lifetime | ~2000 h |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 |
| Irradiance Range | 0.72 W/m² (at 313 nm) |
| Cycle Options | 4 h UV irradiation + 4 h condensation OR 8 h UV irradiation + 4 h condensation |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Spectrum | UV-B, 280–315 nm |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Relative Humidity During Condensation | ≥75% RH |
| Specimen-to-Lamp Distance | 55 mm |
| Lamp Center Spacing | 65–70 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | ~8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJSE-1 |
| Price | USD 7,650 (FOB Shanghai) |
| Max Operating Temperature | 300 °C |
| Product Type | Forced-Air Thermal Aging Chamber |
| Classification | Benchtop Aging Chamber |
| Temperature Range | Ambient +20 °C to 300 °C |
| Temperature Uniformity | ≤ ±0.5 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Temperature Deviation | ≤ ±2.0 °C |
| Heating Rate | ≤60 min (from ambient +20 °C to 200 °C) |
| Total Power Consumption | 6.7 kW (Heating: 6 kW |
| Auxiliary Systems | 0.7 kW) |
| Sound Pressure Level | ≤65 dB(A) |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJSE-1 |
| Temperature Range | RT+20 °C to 300 °C |
| Temperature Uniformity | ≤±2 °C (at steady state) |
| Temperature Fluctuation | ≤±0.5 °C |
| Heating Rate | RT+20 °C to 200 °C in ≤60 min |
| Air Exchange Rate | Adjustable, compliant with IEC 60540 requirements |
| Chamber Dimensions | Customizable (W×H×D) |
| Total Power Consumption | ~6.7 kW (Heating: 6 kW |
| Auxiliary Systems | 0.7 kW) |
| Noise Level | ≤65 dB(A) |
| Compliance | IEC 60540, ASTM D573, ISO 188, GB/T 3512 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJSCY-1215 |
| Price | USD 7,700 (FOB Shanghai) |
| Temperature Range | Ambient to +60 °C (optional ambient-controlled enclosure available) |
| Rainfall Intensity | Adjustable 0.5–10 L/min/m² (calibrated per IEC 60529 Annex B) |
| Droplet Diameter | 0.1–0.4 mm (monodisperse nozzle array, certified per ISO 16750-4) |
| Wind Speed Range | 0–12 m/s (optional integrated axial fan system) |
| Test Duration | 0–99 h 99 min 99 s (programmable timer with non-volatile memory) |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJYS-70 |
| Price | USD 2,800 (FOB Shanghai) |
| Internal Chamber Dimensions (Min–Max) | 600 × 450 × 400 mm to 1600 × 1000 × 500 mm |
| External Dimensions (Min–Max) | 1075 × 630 × 1185 mm to 2300 × 1200 × 1485 mm |
| Chamber Volume (Min–Max) | 108 L to 800 L |
| Salt Solution Reservoir Capacity (Min–Max) | 15 L to 40 L |
| Test Standards Compliance | GB/T 2423.17 (Neutral Salt Spray), GB/T 2423.18 (Acetic Acid Salt Spray), ASTM B117, ISO 9227, JIS Z2371 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJSCY-1216 |
| Price | USD 9,400 (FOB Shanghai) |
| Dust Concentration | 2–4 kg/m² |
| Sand Concentration | 2–4 kg/m² |
| Dust Blowing Velocity | Adjustable up to 2 m/s |
| Sand Blowing Velocity | Adjustable up to 2 m/s |
| Test Temperature Range | RT +10°C |
| Relative Humidity | 45–75% RH |
| Sieve Mesh Aperture | 50 µm nominal wire diameter, 70 µm nominal spacing |
| Talc Powder Loading | 2–4 kg/m² |
| Internal Chamber Dimensions | 800 × 800 × 800 mm |
| Power Supply | AC 380 V, 50 Hz |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJXDW3541 |
| Lamp Power | 6 kW |
| Temperature Range | RT+10°C to 80°C ±1°C (adjustable) |
| Humidity Range | RT+10°C to 80°C ±1°C (adjustable) |
| Spectral Range | 290–800 nm |
| Irradiance | 550 W/m² (300–800 nm) |
| Sample Rack Rotation Speed | 5 rpm |
| Interior Chamber Dimensions | 500 × 500 × 600 mm |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Cycle Interval | 0–240 min (adjustable) |
| Lamp Life | ~2000 h |
| Cooling Method | Air-cooled (3 kW) / Water-cooled (4.5 kW) |
| Lamp Voltage/Current | 220 V ±5%, 20 A |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJCYX-54 |
| Price Range | USD 4,900 – 7,000 |
| Temperature Range | 0°C to 60°C |
| Humidity Range | 40–98% RH (at 30–60°C) |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0°C/min |
| Cooling Rate | ≤20 min (from ambient to 10°C, non-restricted) |
| Ozone Concentration Range | 10–1,000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Mounting | Static Rack |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCYX-542 |
| Temperature Range | 0–60 °C |
| Humidity Range | 40–98% RH (at 30–60 °C) |
| Temperature Uniformity | ≤±2 °C |
| Temperature Stability | ≤±0.5 °C |
| Humidity Stability | +2 / −3% RH |
| Heating Rate | 0.7–1.0 °C/min |
| Cooling Rate | ≤20 min (from ambient to 10 °C, non-restricted) |
| Ozone Concentration Range | 10–1000 pphm |
| Gas Flow Velocity | 12–16 mm/s |
| Compliance | GB/T 7762–2003, GB/T 3642–1992 |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJCK |
| Temperature Range | -70 °C to +350 °C (steady-state at 350 °C) |
| Ramp Rate | ≥5 °C/min |
| Temperature Resolution | 0.1 °C |
| Load Capacity | up to 30 kN |
| Load Cell Accuracy | ±0.01% FS |
| Force Measurement Uncertainty | <±1% or <±0.5% |
| Displacement Accuracy | ±0.5% |
| Strain/Deformation Accuracy | ±0.5% |
| Speed Range | 0.001–500 mm/min (extendable to 1000 mm/min) |
| Speed Accuracy | ±0.5% |
| Effective Width | 420 mm |
| Effective Stroke | ~800 mm (height-adjustable) |
| Safety Features | Electronic travel limit switches, emergency stop circuit |
| Net Weight | 135 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJXDW3541 |
| Price | USD 7,700 (FOB Shanghai) |
| Xenon Lamp Power | 6 kW |
| Spectral Irradiance | 550 W/m² (300–800 nm) |
| Light Exposure Cycle | 0–240 min (adjustable on/off intervals) |
| Humidity Control Range | RT+10°C to 80°C ±1°C (programmable) |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Interval | 0–240 min (adjustable) |
| Spectral Output Range | 290–800 nm |
| Lamp Lifetime | ~2000 h |
| Sample Tray Radius (inner/outer) | 100 / 220 mm |
| Turntable Speed | 5 rpm |
| Distance from Lamp Center to Sample Plane | 165 mm |
| Sample Height Capacity | 420 mm |
| Chamber Interior Dimensions | 500 × 500 × 600 mm (W×D×H) |
| Temperature Uniformity | ≤2°C |
| Cooling Method | Air-cooled (3 kW) + Water-cooled (4.5 kW) |
| Lamp Operating Voltage | 220 V ±5% |
| Lamp Operating Current | 20 A |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-Type) |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Humidity Range | ≥75% RH |
| Illumination Temperatures | 50°C / 60°C / 70°C (60°C recommended) |
| Condensation Temperature | 50°C (±3°C) |
| Cycle Options | 4h UV / 4h Condensation or 8h UV / 4h Condensation |
| UV Lamp Type | UV-B (280–315 nm) |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| Interior Dimensions (D×W×H) | 450 × 1165 × 500 mm |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJCK |
| Price | USD 4,600 (approx.) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJCLR8731 |
| Price | USD 6,300 (FOB Shanghai) |
| High-Temperature Zone Range | +80 °C to +200 °C |
| Low-Temperature Zone Range | −10 °C to −70 °C |
| Thermal Shock Exposure Range | −40 °C to +180 °C |
| Temperature Stability | ≤ ±2 °C |
| Heating Rate | 1–3 °C/min |
| Cooling Rate | 0.7–1 °C/min |
| Temperature Uniformity | ±2 °C |
| Recovery Time | ≤ 5 min |
| Heating Time (RT to +200 °C) | ≤ 40 min |
| Cooling Time (RT to −70 °C) | ≤ 60–90 min |
| Controller | 7.5″ color LCD touchscreen (256-color, wide viewing angle, adjustable backlight), bilingual (English/Chinese) interface |
| Safety Protections | Fuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, overtemperature cutoff, fan overload protection |
| Standard Accessories | Two sample racks, one Ø50 mm cable port |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ-AGE Series |
| Temperature Range | RT+20°C to 300°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Heating Rate | ≤60 min (from RT+20°C to 200°C) |
| Total Power Consumption | 6.7 kW (Heating: 6 kW |
| Auxiliary Systems | 0.7 kW) |
| Noise Level | ≤65 dB(A) |
| Compliance | IEC 60540 (Ed. 2.0, 2019), ASTM D573, ISO 188, GB/T 2951.12–2008 |
| Control System | Imported Digital PID Controller with Dual-Air-Channel Circulation Architecture |
| Safety Features | Dual Independent Overtemperature Cut-off (Electrical & Optical), Redundant Thermal Fuse Protection |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJXDW3541 |
| Price | USD 7,800 (FOB Shanghai) |
| Xenon Lamp Power | 6 kW |
| Spectral Irradiance | 550 W/m² (300–800 nm) |
| Light Exposure Cycle | 0–240 min (adjustable on/off intervals) |
| Humidity Control Range | RT+10°C to 80°C ±1°C (programmable) |
| Rainfall Duration | 0–9999 min (adjustable) |
| Rainfall Interval | 0–240 min (adjustable) |
| Spectral Output Range | 290–800 nm |
| Lamp Lifetime | ~2000 h |
| Sample Tray Radius (inner/outer) | 100 / 220 mm |
| Turntable Speed | 5 rpm |
| Distance from Lamp Center to Sample Plane | 165 mm |
| Sample Height Capacity | 420 mm |
| Chamber Interior Dimensions | 500 × 500 × 600 mm (W×D×H) |
| Temperature Uniformity | ≤2°C |
| Cooling Method | Air-cooled (3 kW) + Water-cooled (4.5 kW) |
| Lamp Operating Voltage | 220 V ±5% |
| Lamp Operating Current | 20 A |
| Real-time & Integrated Irradiance Monitoring | Yes |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-type) |
| Illumination Temperature Range | 50, 60, 70 °C |
| Black Panel Temperature Range | 50, 60, 70 °C |
| UV Wavelength Range | 280–315 nm (UV-B) |
| Internal Chamber Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3 °C |
| Humidity During Condensation | ≥75 %RH |
| Cycle Options | 4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Qingji SCY-1215 |
| Price | USD 7,800 (FOB Shanghai) |
| Compliance | GB/T 4208–2017, GB/T 4942.1–1993, IEC 60529:2013 (equivalent) |
| Chamber Interior Dimensions | 800 × 800 × 800 mm (D×W×H) |
| External Dimensions | 1100 × 1300 × 1700 mm (D×W×H) |
| Oscillating Pipe Radius | 400 mm |
| Nozzle Quantity | 25 |
| Nozzle Diameter | Ø0.4 mm |
| Nozzle Spacing | 50 mm |
| Pipe Diameter | Ø16 mm |
| Water Flow Rate per Nozzle | 0.07 L/min |
| Total Flow Rate | ~1.8 L/min |
| Oscillation Angle | ±60° (120° total sweep) |
| Cycle Time per Full Oscillation | ~12 s |
| Timer Range | 00:00:00 to 99:59:59 (h:mm:ss) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Interior Material | SUS304 2B stainless steel |
| Exterior Enclosure | Cold-rolled steel with anti-rust pretreatment and electrostatic powder coating |
| Sample Tray | Custom stainless steel tray with precision-drilled drainage holes |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-type) |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Wavelength | 280–315 nm (UV-B) |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Humidity During Condensation | ≥75% RH |
| Cycle Options | 4h UV irradiation / 4h condensation or 8h UV / 4h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 |
| Illumination Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Wavelength Range | 280–315 nm (UV-B) |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Temperature Uniformity | ±3°C |
| Humidity During Condensation | ≥75% RH |
| Cycle Options | 4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | ~8 L/day (deionized or distilled water required) |