Empowering Scientific Discovery

Shanghai Qingji Instrumentation & Meter Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelQinji XDW3541
PriceUSD 9,200 (FOB Shanghai)
Xenon Lamp Power6 kW
Temperature RangeRT+10°C to 80°C ±1°C (customizable upper limit available)
Humidity RangeNot applicable (condensation-based moisture simulation only)
Spectral Range290–800 nm
Irradiance at 340 nm0.35–1.50 W/m²/nm (adjustable, calibrated per ISO 4892-2)
Lamp Life~2,000 h (typical, dependent on operating conditions and power cycling)
Sample Rotation Speed5 rpm
Sample Holder Radius (inner/outer)100 / 220 mm
Center-to-Sample Distance165 mm
Chamber Interior Dimensions500 × 500 × 600 mm (L×W×H)
Rainfall Duration0–9999 min (programmable)
Rainfall Interval0–240 min (programmable)
Cooling MethodHybrid air/water-cooled lamp system (3 kW air-cooling + 4.5 kW water-cooling)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQJCK-562A
Chamber TypeUpright
Cooling MethodAir-cooled
Temperature Range-40 °C to +150 °C
Humidity Range30–98 %RH
Temperature Uniformity≤ ±2 °C
Temperature Fluctuation±1 °C (high temp), ±2 °C (low temp)
Humidity Uniformity≤ ±2 %RH
Humidity Fluctuation±2 %RH
Internal Dimensions (W×D×H)450×400×350 mm
Power Supply220 V AC
Rated Power2.0 kW
Net Weight~180 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelQJCK Rapid Temperature Change Test Chamber
PriceUSD 7,000 (FOB Shanghai)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQJXDW3541
Lamp Power4.5 kW (water-cooled)
Temperature RangeRT+10°C to 80°C ±1°C
Humidity RangeNot specified (condensation-based humidity simulation only)
Spectral Range290–800 nm
Radiant Intensity550 W/m² (300–800 nm)
Sample Rotation Speed5 rpm
Chamber Interior Dimensions500 × 500 × 600 mm
Rainfall Duration0–9999 min (adjustable)
Rainfall Cycle Interval0–240 min (adjustable)
Lamp Lifetime~2000 h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQUV1003
Irradiance Range0.72 W/m² (at 313 nm)
Cycle Options4 h UV irradiation + 4 h condensation OR 8 h UV irradiation + 4 h condensation
Illumination Temperature RangeRT+10°C to 70°C
Black Panel Temperature RangeRT+10°C to 70°C
UV SpectrumUV-B, 280–315 nm
Chamber Internal Dimensions (L×W×H)450 × 1165 × 500 mm
Temperature Uniformity±3°C
Relative Humidity During Condensation≥75% RH
Specimen-to-Lamp Distance55 mm
Lamp Center Spacing65–70 mm
Standard Specimen Size75 × 150 mm
Water Consumption~8 L/day (deionized or distilled water required)
External Dimensions (D×W×H)600 × 1325 × 1480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelQJSE-1
PriceUSD 7,650 (FOB Shanghai)
Max Operating Temperature300 °C
Product TypeForced-Air Thermal Aging Chamber
ClassificationBenchtop Aging Chamber
Temperature RangeAmbient +20 °C to 300 °C
Temperature Uniformity≤ ±0.5 °C
Temperature Fluctuation≤ ±0.5 °C
Temperature Deviation≤ ±2.0 °C
Heating Rate≤60 min (from ambient +20 °C to 200 °C)
Total Power Consumption6.7 kW (Heating: 6 kW
Auxiliary Systems0.7 kW)
Sound Pressure Level≤65 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
ModelQJSE-1
Temperature RangeRT+20 °C to 300 °C
Temperature Uniformity≤±2 °C (at steady state)
Temperature Fluctuation≤±0.5 °C
Heating RateRT+20 °C to 200 °C in ≤60 min
Air Exchange RateAdjustable, compliant with IEC 60540 requirements
Chamber DimensionsCustomizable (W×H×D)
Total Power Consumption~6.7 kW (Heating: 6 kW
Auxiliary Systems0.7 kW)
Noise Level≤65 dB(A)
ComplianceIEC 60540, ASTM D573, ISO 188, GB/T 3512
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelQJSCY-1215
PriceUSD 7,700 (FOB Shanghai)
Temperature RangeAmbient to +60 °C (optional ambient-controlled enclosure available)
Rainfall IntensityAdjustable 0.5–10 L/min/m² (calibrated per IEC 60529 Annex B)
Droplet Diameter0.1–0.4 mm (monodisperse nozzle array, certified per ISO 16750-4)
Wind Speed Range0–12 m/s (optional integrated axial fan system)
Test Duration0–99 h 99 min 99 s (programmable timer with non-volatile memory)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQJYS-70
PriceUSD 2,800 (FOB Shanghai)
Internal Chamber Dimensions (Min–Max)600 × 450 × 400 mm to 1600 × 1000 × 500 mm
External Dimensions (Min–Max)1075 × 630 × 1185 mm to 2300 × 1200 × 1485 mm
Chamber Volume (Min–Max)108 L to 800 L
Salt Solution Reservoir Capacity (Min–Max)15 L to 40 L
Test Standards ComplianceGB/T 2423.17 (Neutral Salt Spray), GB/T 2423.18 (Acetic Acid Salt Spray), ASTM B117, ISO 9227, JIS Z2371
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelQJSCY-1216
PriceUSD 9,400 (FOB Shanghai)
Dust Concentration2–4 kg/m²
Sand Concentration2–4 kg/m²
Dust Blowing VelocityAdjustable up to 2 m/s
Sand Blowing VelocityAdjustable up to 2 m/s
Test Temperature RangeRT +10°C
Relative Humidity45–75% RH
Sieve Mesh Aperture50 µm nominal wire diameter, 70 µm nominal spacing
Talc Powder Loading2–4 kg/m²
Internal Chamber Dimensions800 × 800 × 800 mm
Power SupplyAC 380 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQJXDW3541
Lamp Power6 kW
Temperature RangeRT+10°C to 80°C ±1°C (adjustable)
Humidity RangeRT+10°C to 80°C ±1°C (adjustable)
Spectral Range290–800 nm
Irradiance550 W/m² (300–800 nm)
Sample Rack Rotation Speed5 rpm
Interior Chamber Dimensions500 × 500 × 600 mm
Rainfall Duration0–9999 min (adjustable)
Rainfall Cycle Interval0–240 min (adjustable)
Lamp Life~2000 h
Cooling MethodAir-cooled (3 kW) / Water-cooled (4.5 kW)
Lamp Voltage/Current220 V ±5%, 20 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQJCYX-54
Price RangeUSD 4,900 – 7,000
Temperature Range0°C to 60°C
Humidity Range40–98% RH (at 30–60°C)
Temperature Uniformity≤ ±2°C
Temperature Stability≤ ±0.5°C
Humidity Stability+2 / −3% RH
Heating Rate0.7–1.0°C/min
Cooling Rate≤20 min (from ambient to 10°C, non-restricted)
Ozone Concentration Range10–1,000 pphm
Gas Flow Velocity12–16 mm/s
Sample MountingStatic Rack
ComplianceGB/T 7762–2003, GB/T 3642–1992
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
ModelQJCYX-542
Temperature Range0–60 °C
Humidity Range40–98% RH (at 30–60 °C)
Temperature Uniformity≤±2 °C
Temperature Stability≤±0.5 °C
Humidity Stability+2 / −3% RH
Heating Rate0.7–1.0 °C/min
Cooling Rate≤20 min (from ambient to 10 °C, non-restricted)
Ozone Concentration Range10–1000 pphm
Gas Flow Velocity12–16 mm/s
ComplianceGB/T 7762–2003, GB/T 3642–1992
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQJCK
Temperature Range-70 °C to +350 °C (steady-state at 350 °C)
Ramp Rate≥5 °C/min
Temperature Resolution0.1 °C
Load Capacityup to 30 kN
Load Cell Accuracy±0.01% FS
Force Measurement Uncertainty<±1% or <±0.5%
Displacement Accuracy±0.5%
Strain/Deformation Accuracy±0.5%
Speed Range0.001–500 mm/min (extendable to 1000 mm/min)
Speed Accuracy±0.5%
Effective Width420 mm
Effective Stroke~800 mm (height-adjustable)
Safety FeaturesElectronic travel limit switches, emergency stop circuit
Net Weight135 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelQJXDW3541
PriceUSD 7,700 (FOB Shanghai)
Xenon Lamp Power6 kW
Spectral Irradiance550 W/m² (300–800 nm)
Light Exposure Cycle0–240 min (adjustable on/off intervals)
Humidity Control RangeRT+10°C to 80°C ±1°C (programmable)
Rainfall Duration0–9999 min (adjustable)
Rainfall Interval0–240 min (adjustable)
Spectral Output Range290–800 nm
Lamp Lifetime~2000 h
Sample Tray Radius (inner/outer)100 / 220 mm
Turntable Speed5 rpm
Distance from Lamp Center to Sample Plane165 mm
Sample Height Capacity420 mm
Chamber Interior Dimensions500 × 500 × 600 mm (W×D×H)
Temperature Uniformity≤2°C
Cooling MethodAir-cooled (3 kW) + Water-cooled (4.5 kW)
Lamp Operating Voltage220 V ±5%
Lamp Operating Current20 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
ModelQUV1003 (Spray-Type)
Temperature RangeRT+10°C to 70°C
Temperature Uniformity±3°C
Humidity Range≥75% RH
Illumination Temperatures50°C / 60°C / 70°C (60°C recommended)
Condensation Temperature50°C (±3°C)
Cycle Options4h UV / 4h Condensation or 8h UV / 4h Condensation
UV Lamp TypeUV-B (280–315 nm)
Lamp Center-to-Center Spacing65–70 mm
Specimen-to-Lamp Distance55 mm
Standard Specimen Size75 × 150 mm
Water Consumption8 L/day (deionized or distilled water required)
Interior Dimensions (D×W×H)450 × 1165 × 500 mm
External Dimensions (D×W×H)600 × 1325 × 1480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelQJCLR8731
PriceUSD 6,300 (FOB Shanghai)
High-Temperature Zone Range+80 °C to +200 °C
Low-Temperature Zone Range−10 °C to −70 °C
Thermal Shock Exposure Range−40 °C to +180 °C
Temperature Stability≤ ±2 °C
Heating Rate1–3 °C/min
Cooling Rate0.7–1 °C/min
Temperature Uniformity±2 °C
Recovery Time≤ 5 min
Heating Time (RT to +200 °C)≤ 40 min
Cooling Time (RT to −70 °C)≤ 60–90 min
Controller7.5″ color LCD touchscreen (256-color, wide viewing angle, adjustable backlight), bilingual (English/Chinese) interface
Safety ProtectionsFuseless circuit breaker, compressor high-pressure/overheat/overcurrent protection, overtemperature cutoff, fan overload protection
Standard AccessoriesTwo sample racks, one Ø50 mm cable port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQinji
OriginShanghai, China
ModelQJ-AGE Series
Temperature RangeRT+20°C to 300°C
Temperature Uniformity≤ ±2°C
Temperature Fluctuation≤ ±0.5°C
Heating Rate≤60 min (from RT+20°C to 200°C)
Total Power Consumption6.7 kW (Heating: 6 kW
Auxiliary Systems0.7 kW)
Noise Level≤65 dB(A)
ComplianceIEC 60540 (Ed. 2.0, 2019), ASTM D573, ISO 188, GB/T 2951.12–2008
Control SystemImported Digital PID Controller with Dual-Air-Channel Circulation Architecture
Safety FeaturesDual Independent Overtemperature Cut-off (Electrical & Optical), Redundant Thermal Fuse Protection
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelQJXDW3541
PriceUSD 7,800 (FOB Shanghai)
Xenon Lamp Power6 kW
Spectral Irradiance550 W/m² (300–800 nm)
Light Exposure Cycle0–240 min (adjustable on/off intervals)
Humidity Control RangeRT+10°C to 80°C ±1°C (programmable)
Rainfall Duration0–9999 min (adjustable)
Rainfall Interval0–240 min (adjustable)
Spectral Output Range290–800 nm
Lamp Lifetime~2000 h
Sample Tray Radius (inner/outer)100 / 220 mm
Turntable Speed5 rpm
Distance from Lamp Center to Sample Plane165 mm
Sample Height Capacity420 mm
Chamber Interior Dimensions500 × 500 × 600 mm (W×D×H)
Temperature Uniformity≤2°C
Cooling MethodAir-cooled (3 kW) + Water-cooled (4.5 kW)
Lamp Operating Voltage220 V ±5%
Lamp Operating Current20 A
Real-time & Integrated Irradiance MonitoringYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQUV1003 (Spray-type)
Illumination Temperature Range50, 60, 70 °C
Black Panel Temperature Range50, 60, 70 °C
UV Wavelength Range280–315 nm (UV-B)
Internal Chamber Dimensions (L×W×H)450 × 1165 × 500 mm
Temperature Uniformity±3 °C
Humidity During Condensation≥75 %RH
Cycle Options4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation
Lamp Center-to-Center Spacing65–70 mm
Specimen-to-Lamp Distance55 mm
Standard Specimen Size75 × 150 mm
Water Consumption8 L/day (deionized or distilled water required)
External Dimensions (D×W×H)600 × 1325 × 1480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelQingji SCY-1215
PriceUSD 7,800 (FOB Shanghai)
ComplianceGB/T 4208–2017, GB/T 4942.1–1993, IEC 60529:2013 (equivalent)
Chamber Interior Dimensions800 × 800 × 800 mm (D×W×H)
External Dimensions1100 × 1300 × 1700 mm (D×W×H)
Oscillating Pipe Radius400 mm
Nozzle Quantity25
Nozzle DiameterØ0.4 mm
Nozzle Spacing50 mm
Pipe DiameterØ16 mm
Water Flow Rate per Nozzle0.07 L/min
Total Flow Rate~1.8 L/min
Oscillation Angle±60° (120° total sweep)
Cycle Time per Full Oscillation~12 s
Timer Range00:00:00 to 99:59:59 (h:mm:ss)
Power SupplyAC 220 V ±10%, 50 Hz
Interior MaterialSUS304 2B stainless steel
Exterior EnclosureCold-rolled steel with anti-rust pretreatment and electrostatic powder coating
Sample TrayCustom stainless steel tray with precision-drilled drainage holes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQUV1003 (Spray-type)
Illumination Temperature RangeRT+10°C to 70°C
Black Panel Temperature RangeRT+10°C to 70°C
UV Wavelength280–315 nm (UV-B)
Chamber Internal Dimensions (L×W×H)450 × 1165 × 500 mm
Temperature Uniformity±3°C
Humidity During Condensation≥75% RH
Cycle Options4h UV irradiation / 4h condensation or 8h UV / 4h condensation
Lamp Center-to-Center Spacing65–70 mm
Specimen-to-Lamp Distance55 mm
Standard Specimen Size75 × 150 mm
Water Consumption8 L/day (deionized or distilled water required)
External Dimensions (D×W×H)600 × 1325 × 1480 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQingji
OriginShanghai, China
ModelQUV1003
Illumination Temperature RangeRT+10°C to 70°C
Black Panel Temperature RangeRT+10°C to 70°C
UV Wavelength Range280–315 nm (UV-B)
Chamber Internal Dimensions (L×W×H)450 × 1165 × 500 mm
Temperature Uniformity±3°C
Humidity During Condensation≥75% RH
Cycle Options4 h UV irradiation + 4 h condensation or 8 h UV + 4 h condensation
Lamp Center-to-Center Spacing65–70 mm
Specimen-to-Lamp Distance55 mm
Standard Specimen Size75 × 150 mm
Water Consumption~8 L/day (deionized or distilled water required)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0