- All
- Favorite
- Popular
- Most rated
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 3200 Series |
| Frequency Range | 0.0001 – 300 Hz |
| Force Capacity Options | ±225 N or ±450 N (standard) |
| Optional Torsion Motor | 14 N·m or 25 N·m |
| Optional Linear Extension | +150 mm stroke |
| Encoder Resolution | High-resolution optical encoder (torsion mode, up to 62 revolutions) |
| Environmental Compatibility | Integrated with temperature chambers, saline baths, and bioreactors |
| Sensor Range | ±0.002 N to ±450 N (interchangeable load cells) |
| Drive Type | Direct-drive linear electromagnetic motor |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DMA 850 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 to 600 °C |
| Force Range | 0.0001–18 N |
| Resolution (Displacement) | 0.1 nm over 25 mm travel |
| Bearing Type | Frictionless air bearing |
| Actuation | Non-contact lightweight motor |
| Control Technology | DirectStrain™, Auto-Ranging |
| Cooling | Integrated mechanical refrigeration (down to –100 °C without LN₂) |
| Software | TRIOS™ |
| Warranty | 5-year furnace warranty |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TestBenches |
| Load Capacity Options | 200 N or 400 N |
| Configuration | Planar Biaxial TestBench with Integrated Digital Video Extensometry |
| Distribution Type | Authorized Distributor (Imported Equipment) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RS-DSC |
| Sample Throughput | Multi-sample simultaneous measurement |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | 20–100 °C |
| Temperature Accuracy | ±0.02 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | FOX 50 |
| Thermal Conductivity Range | 0.1–10 W/m·K |
| Dimensions (L×W×H) | 250×170×360 mm |
| Accuracy | ±3% |
| Temperature Range | −10°C to 110°C |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA Flex |
| Drive Type | High-Resolution Direct-Drive Motor |
| Torque Sensor | Patented High-Stiffness, Wide-Range Transducer |
| Frame | Ultra-Rigid Monolithic Structure |
| Control | Fully Programmable Strain, Frequency, Temperature, Time, and Mold Closure Pressure |
| Automation | Integrated Robotic Sample Handler |
| Mold Closure | Pneumatically Actuated, Adjustable Pressure Disc |
| Calibration | User-Executable with Replaceable Die Plates |
| Upgrade Path | Field-Upgradeable to Extended Frequency and Strain Range |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA elite |
| Drive Type | Direct-drive motor with high-resolution strain control |
| Torque Sensor | Patented high-stiffness, wide-range sensor with low noise floor |
| Frame Stiffness | Ultra-rigid monolithic frame eliminating instrument compliance |
| Temperature Control | Integrated gas-cooling unit for rapid and stable thermal regulation |
| Pressure Control | Pneumatically actuated, user-adjustable die closure pressure |
| Automation | Optional robotic autosampler for unattended operation |
| Calibration | User-performed torque and geometry calibration |
| Compliance | Designed to support ASTM D6204, ISO 6673, and ISO 10985 test methods |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 2500 |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | –180 °C to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Throughput | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without LN₂) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery X3 DSC |
| Sample Capacity | Up to 3 simultaneous samples |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | –180 °C to 550 °C |
| Temperature Accuracy | ±0.025 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 25 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | Up to 200 K/min |
| Temperature Precision | ±0.01 °C |
| DSC Heat Flow Range | ±500 mW |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 802/802L |
| Measurement Principle | True Mechanical Differential Expansion Detection |
| Sensor Type | High-Stability LVDT with Digital Amplification |
| Contact Force Range | 0.02–1.00 N (User-Adjustable) |
| Configuration | Convertible Between Differential and Single-Sample Modes |
| Thermal Uniformity | Optimized Horizontal Furnace Design |
| Vibration Resistance | Integrated Mechanical Isolation Architecture |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC 250 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −180 °C to 725 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Precision | ±0.008 °C |
| Heating/Cooling Rate | up to 200 K/min |
| DSC Heat Flow Range | ±500 mW |
| Sample Capacity | Single-sample configuration |
| Cooling Option | Mechanical refrigeration (optional, extends low-temperature operation without liquid nitrogen) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DSC2500 |
| Temperature Range | –180 to 725 °C |
| Temperature Accuracy | ±0.025 °C |
| Temperature Precision | ±0.005 °C |
| Baseline Flatness (–50 to 300 °C) | <5 μW |
| Baseline Repeatability (–50 to 300 °C) | <10 μW |
| Enthalpy Accuracy | ±0.04 % |
| Heating/Cooling Rate | 0.1–100 K/min |
| Modulated DSC | Standard |
| Tzero® Technology | Advanced (T4P) |
| Direct Cp Measurement | Supported |
| User-Replaceable Furnace | Yes |
| 54-Position Autosampler | Standard |
| Dual-Gas Delivery Module | Standard |
| Color Touchscreen Interface | Standard |
| Optical Accessory Compatibility | Optional |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 801 / DIL 801L |
| Configuration | Horizontal, single-sample dilatometer |
| Operating Atmosphere | Air, vacuum, or inert gas (N₂, Ar) |
| Temperature Range | −150 °C to 1600 °C (dependent on furnace and sensor option) |
| Force Control | User-adjustable contact force from 0.02 N to 1.00 N |
| Sensor Type | High-stability LVDT with digital signal conditioning |
| Compliance | ASTM E228, ISO 11359-1/-2, DIN 51045-1, USP <671> |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DLF-1200 |
| Temperature Range | RT to 1200 °C |
| Laser Pulse Width | 300–400 µs |
| Atmosphere Options | Air, Inert Gas, Vacuum (down to 10⁻³ torr) |
| Detection | Liquid Nitrogen-Cooled IR Detector |
| Heating System | Resistive Furnace |
| Measurement Principle | Laser Flash Analysis (LFA) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | 3450 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA) / DMTA |
| Force Range | ±3 kN (standard), ±6 kN (high-load option) |
| Displacement Range | up to ±22 mm |
| Frequency Range | 0.0001 Hz to 200 Hz |
| Temperature Range | –150 °C to 300 °C |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DLF 2800 |
| Instrument Principle | Laser Flash Method (LFA) |
| Dimensions (L×W×H) | 12.7 × 12.7 × 6 cm |
| Accuracy | ±2.3% |
| Thermal Conductivity Range | 0.1–2000 W/m·K |
| Repeatability | ±2% |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DIL 803/803L |
| Configuration | Dual-sample horizontal dilatometer with differential capability |
| Sensor Type | High-stability LVDT with digital amplifier |
| Contact Force Range | User-adjustable from 0.02 N to 1.00 N |
| Furnace Compatibility | Interchangeable TA furnace modules |
| Operating Mode | Simultaneous dual-sample or differential (sample vs. inert reference) |
| Compliance | Designed for ASTM E228, ISO 11359-2, and USP <640> thermal expansion testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | TAM 48 |
| Simultaneous Sample Capacity | Up to 48 |
| Temperature Range | 4–150 °C |
| Temperature Accuracy | ±0.1 °C |
| Instrument Type | Isothermal Titration & Reaction Microcalorimeter |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 5500 |
| Frequency Range | 0.0001 – 20 Hz |
| Force Control Range | ±0.002 N to ±200 N |
| Architecture | Single-Beam Open-Frame Design |
| Environmental Compatibility | Compatible with Incubators & Gloveboxes |
| Optional Fixture | 24-Well Compression Fixture for Multi-Specimen Testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ElectroForce |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Control | Physiological Saline Bath |
| Loading Mode | Displacement-Controlled Tension-Tension or Compression-Compression |
| Sample Capacity | Multiple Independent Test Stations |
| Cycle Resolution | High-Resolution Linear Encoder-Based Displacement Measurement |
| Compliance | Designed for ISO 14242-1, ASTM F2129, and FDA Guidance for Cardiovascular Implant Fatigue Testing |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DTC-300 |
| Measurement Principle | Guarded Heat Flow Method (ASTM E1530) |
| Sample Temperature Range | −40 °C to 200 °C (with optional chiller and heater modules) |
| Thermal Resistance Range | Three interchangeable sensor modules covering low-, medium-, and high-resistance regimes |
| Sample Form Compatibility | Solids, thin films (multi-layer stack), pastes, liquids (with custom containment) |
| Compliance | ASTM E1530, ISO 8301, EN 12667 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery SDT 650 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1500 °C |
| Temperature Stability | ±2% |
| Maximum Sample Mass | 200 mg |
| Base Pressure | 50 μTorr |