| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ-NZ |
| Max Torque | 10,000 N·m |
| Torque Measurement Range | 0–10,000 N·m |
| Torque Resolution | ±0.001° (angular) |
| Torsion Angle Range | 0 to ±100,000° |
| Motor Power | 2 kW |
| Torque Measurement Accuracy | ±0.5% FS |
| Torsion Angle Accuracy | ±0.5% FS |
| Angular Resolution | 0.001° |
| Torsion Speed Range | 0.01–1,000 °/min (infinitely variable) |
| Gauge Length Adjustment | up to 1,500 mm |
| Specimen Clamping Diameter | Φ8–Φ40 mm (expandable) |
| Dimensions (L×W×H) | 2800 × 4700 × 1250 mm |
| Weight | 1,500 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QJ-REB |
| Price | USD 5,900 |
| Power Supply | 220 V, 50 Hz |
| Drop Height | 460 mm |
| Steel Ball Diameter | 16 mm |
| Steel Ball Mass | 16.7 g |
| Time Resolution | 0.0001 s |
| Rebound Coefficient Range | 25%–80% |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJ210 |
| Price | USD 6,300 (FOB Shanghai) |
| Load Capacity | 10 N to 2500 N (interchangeable within range) |
| Accuracy Class | 0.5 |
| Effective Test Width | 150 mm |
| Effective Stroke | 300 mm |
| Speed Range | 0.01–300 mm/min (adjustable) |
| Speed Accuracy | ±0.5% of reading |
| Displacement Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Sensor | High-precision load cell (USA-sourced) |
| Controller | Panasonic全数字交流伺服系统 |
| Control Mode | Full-digital closed-loop control (constant load, constant strain, constant displacement) |
| Safety Protection | Dual mechanical & software-based limit protection, overload shutdown (>110% FS), emergency stop button |
| Power | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Net Weight | 45 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210 |
| Instrument Type | Electromechanical Tensile Tester |
| Maximum Test Load | 2.5 kN |
| Force Measurement Range | 0–2.5 kN |
| Force Accuracy | ±0.5% of full scale |
| Crosshead Travel | 300 mm |
| Displacement Resolution | 0.001 mm |
| Effective Test Width | 150 mm |
| Speed Range | 0.01–1000 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement Accuracy | ±0.5% of reading |
| Load Cell Resolution | 500,000 counts (full-scale, unsegmented) |
| Motor Power | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Net Weight | 40 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 2500 N |
| Force Accuracy Class | 0.5 |
| Effective Test Width | 150 mm |
| Effective Test Height | 300 mm |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Safety Protection | Dual electronic and mechanical limit switches, overload protection at 110% of full scale, emergency stop button |
| Power | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Net Weight | 40 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0–2500 N |
| Load Accuracy | ±0.5% of full scale |
| Effective Test Width | 150 mm |
| Effective Test Height | 300 mm |
| Crosshead Speed Range | 0.01–1000 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain/Deformation Measurement Accuracy | ±0.5% of indicated value |
| Power Motor | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Net Weight | 40 kg |
| Resolution | 500,000 counts (full-scale, no range switching) |
| Load Cell Resolution | Fixed throughout entire range |
| Safety Features | Electronic limit protection, overload protection at 110% of max load, manual/auto return, jog-controlled vertical movement |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210-2500N |
| Max Test Force | 2.5 kN |
| Force Range | 0–2.5 kN |
| Force Accuracy Class | 0.5 |
| Stroke | 300 mm |
| Speed Range | 0.001–300 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Load Cell Resolution | 0.01% of full scale |
| Effective Width | 150 mm |
| Safety Features | Electronic limit protection, emergency stop button |
| Weight | ~45 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJ210-F |
| Price | USD 7,800 (FOB Shanghai) |
| Max Load Capacity | 200 kgf |
| Force Accuracy Class | Class 1 (per ISO 7500-1) |
| Effective Force Range | 0.2–100% of full scale |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| XY Axis Travel | 0–75 mm |
| Test Speed | 0–500 mm/min (adjustable in 0.01 mm/min increments) |
| Max Test Height | 150 mm |
| Displacement Accuracy | ±1% of reading |
| Fine Adjustment Resolution | 0.01 mm |
| Drive Motor | 200 W, 220 VAC |
| Dimensions (L×W×H) | 400 × 300 × 1000 mm |
| Net Weight | 65 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ2105000N |
| Maximum Load Capacity | 5000 N |
| Load Cell Accuracy | 0.01% |
| Test Accuracy | < ±1% |
| Effective Width | 150 mm |
| Effective Stroke | 800 mm (extendable) |
| Test Speed Range | 1–300 mm/min |
| Speed Accuracy | ±1% |
| Displacement Measurement Accuracy | ±1% |
| Strain Measurement Accuracy | ±1% |
| Safety Features | Electronic Limit Switches, Emergency Stop Button |
| Weight | ~85 kg |
| [Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A |
| Instrument Type | Electromechanical Tensile Testing Machine |
| Maximum Load Capacity | Up to 5000 N |
| Accuracy Class | 0.5 |
| Effective Test Width | 150 mm |
| Effective Stroke | 500 mm |
| Test Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement Accuracy | ±0.5% of indicated value |
| Load Cell | High-precision U.S.-sourced sensor |
| Controller | Panasonic full-digital AC servo drive system |
| Control Mode | Full-digital closed-loop control (constant load, constant strain, constant displacement) |
| Power | 200 W |
| Dimensions (L×W×H) | 430 × 315 × 855 mm |
| Net Weight | 45 kg] |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A |
| Max Test Load | 50 kN |
| Load Application Rate | 1 kN/s (adjustable) |
| Platen Spacing Adjustment Range | 1 mm resolution |
| Platen Dimensions | 590 mm (L) × 355 mm (W) |
| Overall Dimensions | 590 × 355 × 1640 mm |
| Weight | ~85 kg |
| Load Cell Accuracy Class | 0.5 |
| Effective Test Width | 150 mm |
| Vertical Travel | 800 mm |
| Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Load Resolution | 500,000 counts (single-range, no auto-ranging) |
| Force Units | gf, kgf, N, kN, lbf |
| Control System | Panasonic full-digital AC servo controller |
| Load Cell | High-precision U.S.-sourced strain-gauge sensor |
| Safety Features | Software-based overload diagnosis, electronic limit switches, 110% over-load protection |
| Return Mode | Manual or programmable automatic return to initial position |
| Power Supply | 200 V AC, 400 W |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A |
| Maximum Test Load | 5 kN |
| Force Accuracy | ±0.5% or ±1% |
| Test Stroke | 150 mm |
| Displacement Resolution | ±0.5% of reading |
| Load Cell | High-precision U.S.-sourced sensor |
| Control System | Panasonic full-digital AC servo controller |
| Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Effective Test Width | 150 mm |
| Effective Tensile Travel | 800 mm |
| Load Range | 5 N to 5 kN (multi-range, auto-switching) |
| Force Resolution | 500,000 counts, no internal range switching |
| Units | gf, kgf, N, kN, lb |
| Compliance | ASTM D638, ISO 527, GB/T 1040, JIS K7113, DIN 53455, YY/T 0149, QB/T 2471 |
| Power Supply | 200 V, 400 W |
| Dimensions (L×W×H) | 590 × 355 × 1640 mm |
| Weight | ~85 kg |
| [Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Electronic Universal Tensile Tester |
| Max Test Load | 5 kN |
| Force Measurement Range | 0.2–100% of Full Scale |
| Force Accuracy | Class 0.5 (ISO 7500-1 / ASTM E4) |
| Crosshead Travel | 800 mm |
| Effective Test Width | 150 mm |
| Test Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Resolution | 0.001 mm (500,000-count encoder) |
| Force Resolution | Constant full-scale resolution, no range switching |
| Load Cell | High-precision imported strain-gauge sensor (USA-made) |
| Drive System | Panasonic AC servo motor + Taiwan-made precision gearmotor + preloaded ball screw |
| Control System | Full-digital servo controller with closed-loop feedback |
| Compliance | Fully supports GB, ISO 527, ISO 37, ASTM D412, ASTM D638, ASTM D882, JIS K6251, YY/T 0615.1, EN 455-2, EN 149, EN 13795] |
| Brand | Qinji |
|---|---|
| Model | QJ210A |
| Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 5000 N |
| Effective Test Width | 500 mm |
| Effective Tensile Travel | 600 / 800 mm |
| Test Speed Range | 0.001–1000 mm/min |
| Speed Accuracy | ±1% of indicated value |
| Load Resolution | ±1/250000 full scale (constant across entire range) |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain Measurement Accuracy | ±0.5% of indicated value |
| Safety Features | Electronic limit protection, overload protection (10% above capacity), manual/auto return to initial position |
| Dimensions (W×D×H) | 960 × 650 × 2000 mm |
| Weight | 85 kg |
| Compliance | ISO 11339, ASTM D903, ASTM D3330, ISO 8510-2, JIS Z 0237 |
| Brand | Qinji |
|---|---|
| Model | QJ210A-5000N |
| Load Capacity | 0–5 kN |
| Load Accuracy | ±0.5% of full scale |
| Effective Test Width | 150 mm |
| Max Travel Distance | 800 mm |
| Speed Range | 0.01–500 mm/min |
| Speed Accuracy | ±0.5% of set value |
| Displacement Accuracy | ±0.5% of reading |
| Deformation Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Power Supply | 200 V AC, 400 W |
| Dimensions (L×W×H) | 590 × 355 × 1640 mm |
| Net Weight | ~85 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ210A-5KN |
| Load Capacity | 0–5000 N |
| Load Accuracy | ±0.5% |
| Test Speed Range | 0.001–1000 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Measurement Accuracy | ±0.5% |
| Strain/Deformation Accuracy | ±0.5% |
| Effective Test Width | 150 mm |
| Effective Tensile Travel | 300 mm (extendable) |
| Safety Features | Electronic travel limit protection, emergency stop button |
| Machine Weight | ~45 kg |
| Control Interface | Full LCD digital control + PC-based software integration |
| Compliance | Designed for ASTM E8/E21, ISO 6892-1, GB/T 228.1 testing protocols |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211 Series |
| Type | Electromechanical Universal Testing Machine |
| Maximum Load Capacity | 30 kN |
| Load Cell Accuracy | 0.01% FS |
| Force Measurement Accuracy | < ±0.5% |
| Test Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Deformation Measurement Accuracy | ±0.5% |
| Effective Test Width | ~420 mm |
| Effective Tensile Travel | ~800 mm |
| Safety Features | Electronic Limit Switches, Emergency Stop Button, Stroke Safeguard |
| Machine Weight | ~140 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211D-1 |
| Frequency Range | 0.01–100 Hz |
| Force Accuracy | ±1% (2–100% FS) |
| Dynamic Force Ripple | ≤2% |
| Actuator Stroke | ±200 mm (±0.5% accuracy) |
| Closed-Loop Control Bandwidth | 10 kHz |
| Waveform Options | Sine, Square, Triangle, Trapezoidal, Sawtooth, Half-Sine, Half-Triangle, Random, User-Defined, and External Input |
| Control Modes | Force, Displacement, and Strain |
| Frequency Resolution | 0.001 Hz |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211-H |
| Instrument Type | Electronic Universal Testing Machine |
| Load Capacity | 0.00 N to 30 kN |
| Load Accuracy | ±0.5% |
| Effective Test Width | 320 mm |
| Effective Tensile Stroke | 500 mm (optional 800 mm) |
| Test Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement Measurement Accuracy | ±0.5% of reading |
| Deformation Measurement Accuracy | ±0.5% of reading |
| Load Cell Resolution | 500,000 counts (single-range, no auto-ranging) |
| Control System | Panasonic全-digital AC servo controller |
| Data Acquisition | High-precision U.S.-sourced load cell |
| Safety Protection | Software-based diagnosis, electronic travel limit, overload protection at 110% capacity |
| Power Requirement | 2–5 kW |
| Net Weight | ~145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211H |
| Max. Test Load | 30 kN |
| Platen Dimensions | 1000 mm × 1000 mm |
| Platen Spacing | 1000 mm |
| Accuracy Class | 0.5 |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Effective Test Width | 320 mm |
| Travel Range | 500 mm (extendable to 800 mm) |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement & Deformation Accuracy | ±0.5% of indicated value |
| Control System | Panasonic full-digital AC servo controller |
| Software | Full-closed-loop digital control system supporting constant-force, constant-strain, and constant-displacement modes |
| Safety Protection | Automatic overload cutoff at 110% FS, electronic limit switches, real-time software diagnostics |
| Power | 2–5 kW |
| Net Weight | ~145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211H-30KN |
| Max. Test Force | 30 kN |
| Platen Dimensions | 1000 mm × 1000 mm |
| Platen Spacing | 1000 mm |
| Load Cell Accuracy Class | 0.5 |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Effective Test Width | 1000 mm |
| Crosshead Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Displacement & Deformation Accuracy | ±0.5% of reading |
| Load Sensing | High-precision U.S.-sourced load cell |
| Control System | Panasonic full-digital AC servo controller |
| Software | Full-closed-loop digital control system supporting constant-force, constant-strain, and constant-displacement modes |
| Safety Protection | Electronic limit switches, software-based overload diagnosis (10% over capacity), automatic return post-test |
| Power | 2–5 kW |
| Net Weight | ~145 kg |
| [Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211H2 |
| Max Load Capacity | 30 kN |
| Load Accuracy | Class 0.5 |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Effective Test Width | 320 mm |
| Effective Stroke | 500 mm (extendable to 800 mm) |
| Test Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Sensor | High-precision U.S.-sourced load cell |
| Controller | Panasonic all-digital AC servo system |
| Control System | Full-digital closed-loop architecture supporting constant stress, constant strain, and constant displacement modes |
| Safety Protection | Software-based diagnostics, electronic limit switches, overload protection at 110% of full scale |
| Power | 2–5 kW |
| Net Weight | ~145 kg] |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S |
| Max. Test Load | 20 kN |
| Platen Dimensions | 420 mm × 420 mm |
| Load Accuracy | ±0.5% of full scale |
| Force Resolution | 1/500,000 FS |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Accuracy | ±0.5% of set value |
| Displacement Resolution | 0.048 µm |
| Displacement Accuracy | ±0.5% of set value |
| Data Acquisition Rate | Up to 1000 Hz |
| Closed-Loop Control Frequency | 1000 Hz |
| Crosshead Speed Range | 1×10⁻⁷ – 1×10⁻³ mm/min (infinitely variable) |
| Test Width | 420 mm |
| Heating Power | 2000 W |
| Temperature Stability | ±1 °C |
| Temperature Accuracy | ±0.2 °C |
| Overall Dimensions (W×D×H) | 775 × 660 × 1740 mm |
| Motor Power | 750 W |
| Net Weight | 280 kg |
| Safety Features | Overload protection, mechanical travel limit, voltage overload protection |
| Compliance | Meets ISO 7500-1 Class 0.5, ASTM E4, ASTM D695, ISO 604, GB/T 228.1, GB/T 1041 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | QJ211S |
| Price Range | USD 4,900 – 7,000 |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity | 0.02 N to 30 kN |
| Load Accuracy | ±0.5% |
| Accuracy Class | 0.5 |
| Effective Force Measurement Range | 0.4%–100% of Full Scale |
| Force Control Rate Range | 0.4–100% FS/s |
| Force Control Rate Error | ±0.5% of set value |
| Force Resolution | 500,000 counts (no internal range switching, constant resolution across full scale) |
| Effective Test Width | 400 mm |
| Effective Tensile Stroke | 500 mm |
| Test Speed Range | 0.01–500 mm/min (adjustable in real time) |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Control Accuracy | ±0.5% of set value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Displacement Resolution | 0.025 µm |
| Strain/Deformation Measurement Accuracy | ±0.5% of indicated value |
| Encoder Resolution | 1000 pulses/rev, positional accuracy: 0.001 mm |
| Crosshead Movement | Dual-speed (fast/slow) motorized control with jog function |
| Safety Protection | Electronic travel limit switches |
| Return Function | Manual or programmable automatic return to initial position |
| Overload Protection | Automatic shutdown at >110% of rated load |
| Motor | 400 W, 220 V AC |
| Dimensions (L×W×H) | 500 × 450 × 1650 mm |
| Net Weight | 165 kg |
| Brand | Qinji |
|---|---|
| Model | QJ211S |
| Maximum Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Effective Tensile Stroke | 500 mm (optional 800 mm) |
| Test Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of indicated value |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement & Strain Measurement Accuracy | ±0.5% of indicated value |
| Load Cell | High-precision U.S.-sourced sensor |
| Control System | Panasonic full-digital AC servo controller |
| Software | Windows-based closed-loop test management system supporting constant stress/strain/displacement control |
| Safety Protection | Electronic limit switches, software self-diagnosis, overload protection at 110% of full scale |
| Power Requirement | 2–5 kW |
| Net Weight | ~145 kg |
| Compliance | GB, ISO, ASTM, JIS, DIN, YB, YY, QC, HG, and other international and industry-specific standards |
| Brand | Qinji |
|---|---|
| Model | QJ211S |
| Type | Electronic Universal Testing Machine |
| Max Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Stroke (Tensile Space) | 500 / 800 mm |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Load Cell | High-precision U.S.-sourced sensor |
| Controller | Panasonic全数字 AC servo controller |
| Control System | Full-digital closed-loop system supporting constant stress, constant strain, and constant displacement modes |
| Safety Protection | Software-based overload diagnosis, electronic travel limit, auto-return function, 110% over-load cut-off |
| Weight | ~145 kg |
| Compliance | GB, ISO, ASTM, JIS, DIN, EN, YB, JT, JG, QC, YY, YD, HG, SL, SY, BB, QB standards |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S Glass-Specific |
| Max Load | 10 kN |
| Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Stroke (Tensile) | 500/800 mm |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement Accuracy | ±0.5% of reading |
| Strain Measurement Accuracy | ±0.5% of reading |
| Load Cell | High-Precision U.S.-Sourced Sensor |
| Controller | Panasonic Full-Digital AC Servo System |
| Control Mode | Full-Digital Closed-Loop (Constant Load, Constant Displacement, Constant Strain) |
| Safety Protection | Software Diagnostics, Electronic Limit Switches, Overload Protection (110% FS), Automatic Return Post-Test |
| Weight | ~145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | QJ211S |
| Price | USD 1,700 (FOB Shanghai) |
| Instrument Type | Electromechanical Universal Tensile Tester |
| Maximum Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Effective Stroke | 500 mm |
| Speed Range | 0.01–50,000 mm/min (standard default: 300 mm/min) |
| Speed Accuracy | ±0.5% of indicated value |
| Displacement Measurement Accuracy | ±0.5% of indicated value |
| Strain Measurement Accuracy | ±0.5% of indicated value |
| Load Resolution | 500,000 counts (full-scale, no internal range switching) |
| Motor Power | 400 W |
| Net Weight | 145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S-30KN |
| Max Test Load | 30 kN |
| Load Speed Range | 0.01–500 mm/min |
| Force Accuracy | ±0.5% of reading |
| Displacement Accuracy | ±0.5% of reading |
| Deformation Accuracy | ±0.5% of reading |
| Effective Test Width | 420 mm |
| Effective Vertical Travel | 500 mm |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Crosshead Return | Manual rapid return & automatic post-test return |
| Overload Protection | Activates at >110% of full scale |
| Motor Power | 400 W |
| Net Weight | 145 kg |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211S2 |
| Type | Electromechanical Universal Testing Machine |
| Max Load Capacity | 10 kN |
| Load Accuracy Class | 0.5 |
| Effective Test Width | 320 mm |
| Stroke (Tensile) | 500/800 mm |
| Speed Range | 0.01–300 mm/min |
| Speed Accuracy | ±0.5% of reading |
| Force Resolution | 500,000 counts (full-scale, no range switching) |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Sensor | High-Precision U.S.-Sourced Load Cell |
| Controller | Panasonic Full-Digital AC Servo System |
| Control Mode | Closed-Loop Digital Control (Constant Load, Constant Displacement, Constant Strain) |
| Safety Protection | Software Diagnostics, Electronic Limit Switches, Overload Protection (110% FS), Emergency Stop |
| Weight | ~145 kg |
| Compliance | GB, ISO 178, ASTM D790, JIS K7203, DIN 53455, EN 1288-3, YB/T 5349, JT/T 604, QC/T 989 |