| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | EQ7000 |
| Water Grade | Type I (ASTM D1193-22, ISO 3696:1987, CLSI EP28-A3c) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | ≤ 5 ppb |
| Endotoxins | < 0.001 EU/mL |
| Microbial Count | < 1 CFU/100 mL |
| Particulates (>0.22 µm) | Not Detectable |
| Flow Rate | Up to 2 L/min (Q-POD® arm, three manual settings) |
| Display | 7-inch color touchscreen interface |
| Connectivity | Ethernet (DHCP/fixed IP), USB data export |
| Terminal Purifier Compatibility | Millipak®, Millipak® Gold, Biopak®, EDS-Pak®, LC-Pak®, VOC-Pak® |
| Compliance | Meets or exceeds ASTM, ISO, CLSI, and USP <1231> specifications for purified water and water for injection (WFI)-grade applications when paired with appropriate POD-Pak® modules |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q IQ 7000 |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | ≤2 ppb (µg/L), typical ≤5 ppb (µg/L) |
| Microbial Count | <0.01 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| RNase | <1 pg/mL |
| DNase | <5 pg/mL |
| Proteases | <0.15 µg/mL |
| Particles (>0.2 µm) | Zero particles >0.22 µm |
| Flow Rate | 0.05–2 L/min |
| Feed Water Conductivity | <100 µS/cm @ 25°C |
| Feed TOC | <50 ppb |
| Operating Pressure | 0.1–6 bar |
| Operating Temperature | 5–35°C |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Integral |
| Production Capacity | 3, 5, 10, or 15 L/h (Pure Water) / Up to 2 L/min (Ultrapure Water) |
| Resistivity (Ultrapure) | 18.2 MΩ·cm @ 25 °C (temperature-compensated) |
| TOC (Ultrapure) | 1–5 ppb |
| Bacterial Count (Ultrapure) | <0.1 CFU/mL |
| Particles >0.22 µm (Ultrapure) | <1/mL |
| Endotoxin (with UF module) | <0.001 EU/mL |
| Resistivity (Pure Water) | 5–15 MΩ·cm @ 25 °C |
| TOC (Pure Water) | <30 ppb |
| Silica Rejection | >99.9% |
| Microbial Load (Pure Water) | <10 CFU/mL |
| Integrated Online TOC Analyzer | Range 1–999 ppb, Accuracy ±1 ppb |
| Conductivity/Resistivity Sensors | Four independent cells, Cell Constant 0.01 cm⁻¹, Temp. Sensitivity ±0.1 °C |
| Water Tank | 30 L, Conical Bottom, Air Filter with 0.22 µm Hydrophobic Membrane, Overflow Protection, Level Accuracy ±5% |
| System Interface | Full-color graphical display, Chinese-language OS, Real-time水质 & Maintenance Status |
| Connectivity | RS232, Ethernet |
| Data Logging | 12-month integrated audit trail |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Direct 8 / Milli-Q Direct 16 |
| Purification Technology | RO + Ion Exchange + Dual-Wavelength UV (185/254 nm) + Final Polishing Cartridge |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | ≤5 ppb |
| Bacteria | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| RNase | <0.01 ng/mL |
| DNase | <4 pg/mL |
| Recovery Rate (RO) | Up to 66% |
| Feed Water Temperature Compensation | Yes |
| Pre-treatment | Progard® Cartridge with Recirculating Reject Loop |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Synergy UV |
| Production Flow Rate | 1.5 L/min |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | < 5 ppb |
| Particles > 0.22 µm | < 1/mL |
| Microbial Count | < 1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| Electrode Material | 316L Stainless Steel |
| Noise Level | < 40 dB (at 1 m) |
| Integrated UV Lamp | Dual-Wavelength (185/254 nm) |
| Final Filtration | 0.22 µm Terminal Filter |
| System Monitoring | Real-time Resistivity & TOC Trending, Cartridge Life Algorithm, Auto-Recirculation, Dry-Run & Low-Water Protection |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV10 Control |
| Capacity | 20 L |
| Ultimate Vacuum | <6.5 hPa (<4.9 Torr) |
| Rotation Speed | 20–280 rpm |
| Heating Bath Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Surface Area | 1200 cm² |
| Integrated Vacuum Controller | Yes |
| Solvent Database | User-Expandable |
| Auto-Distillation by Volume | Yes |
| Boiling Point Detection | Automatic |
| Data Interface | RS232 & USB |
| Safety Features | Auto Venting, Auto Coolant Shutoff, Heating Bath Overtemperature Protection, Real-Time Cooling Water Monitoring |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 10 digital V-C |
| Capacity | 3 L |
| Rotation Speed | 20–280 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Surface Area | 1500 cm² |
| Heating Bath Type | Dual-purpose (water/oil) |
| Interface | RS232 + IR remote control |
| Safety Features | Motorized lift with power-fail auto-retract, adjustable safety temperature cutoff, dry-run protection, programmable descent endpoint, bath lockout function |
| Optional | Explosion-proof coated glass assembly |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 8 V-C |
| Capacity | 3 L |
| Rotation Speed | 5–300 rpm |
| Heating Bath Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 K |
| Condenser Cooling Area | 1500 cm² |
| Lift Mechanism | Manual (120 mm travel) |
| Heating Power | 1300 W |
| Input Voltage | 100–240 V, 50/60 Hz |
| DC Motor Supply | 24 V |
| Dimensions (W×D×H) | 510 × 490 × 345 mm |
| Weight | 17.2 kg |
| IP Rating | IP20 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 10 control V-C auto |
| Capacity | 3 L |
| Ultimate Vacuum Range | 1050 – 1 mbar |
| Rotation Speed | 5 – 280 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 K |
| Condenser Surface Area | 1500 cm² |
| Motor Type | DC |
| Lift Stroke | 140 mm |
| Heating Power | 1300 W |
| Input Power | 1400 W |
| Dimensions (W × D × H) | 500 × 430 × 410 mm |
| Weight | 21.5 kg |
| IP Rating | IP20 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Vacuum Sensor Accuracy | ±2 mbar |
| Timer | Yes |
| RS232 Interface | Yes |
| Certifications | DIN EN 60529 compliant |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 3 pro V Complete |
| Capacity | 4 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 20–300 rpm |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±1 K |
| Condenser Surface Area | 1500 cm² |
| Motor Type | DC |
| Lift Stroke | 150 mm (manual) |
| Power Input | 1400 W |
| Dimensions (W×D×H) | 440 × 530 × 330 mm |
| Weight | 28.3 kg |
| Protection Class | IP20 |
| Voltage | 100–240 V, 50/60 Hz |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Milli-Q® SQ 2 Series |
| Price Range | USD 1,400 – 11,500 (FOB) |
| Feed Water | Municipal Tap Water |
| Product Water Grades | ASTM Type I (Ultra-pure), ISO 3696 Grade 1, CLSI EP28-A3c Class I, USP Purified Water (for RO mode) |
| Resistivity | ≥18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <5 ppb |
| Bacterial Count | <0.1 CFU/mL |
| Particulates (>0.22 µm) | <1/mL |
| Endotoxin | <0.001 EU/mL |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 8 FLEX |
| Capacity | 3 L |
| Rotation Speed | 5–300 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 K |
| Condenser Surface Area | 1500 cm² |
| Heating Power | 1300 W |
| Lift Stroke | 120 mm |
| Dimensions (W×D×H) | 510 × 490 × 345 mm |
| Weight | 15.5 kg |
| Protection Class | IP20 |
| Operating Voltage | 100–240 V, 50/60 Hz |
| DC Motor Supply | 24 V |
| Compatibility | Full mechanical and dimensional compatibility with IKA RV 10 series glassware |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | RV 10 basic V-C |
| Capacity | 3 L |
| Rotational Speed | 20–280 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±5 °C |
| Condensing Surface Area | 1500 cm² |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix Essential 3 / 5 / 10 / 15 |
| Production Rate | 3 / 5 / 10 / 15 L/h |
| Feed Water | Municipal tap water |
| Resistivity | >5.0 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <10 CFU/mL (with optional UV lamp) |
| Particles (>0.1 µm) | <1 particle/mL |
| System Recovery Rate | >15% |
| Water Grade | ASTM Type II / ISO 3696 Grade 2 / CLSI EP28-A3b compliant |
| Brand | Merck |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IPAK Gard® Pre-Treatment Purification Cartridge |
| Price Range | USD 85 – 1,420 (FOB) |
| Feed Water Compatibility | Elix® System Output |
| Final Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Heavy Metals & Soluble Silica | < 0.1 ppb |
| Total Organic Carbon (TOC) | < 5 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particles (> 0.1 µm) | < 1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Milli-Q Advantage A10 |
| Pure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix Reference 3 / 5 / 10 / 15 |
| Purified Water Grade | ASTM D1193 Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm (at 25 °C) |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Contamination | <0.25 CFU/mL |
| Heavy Metals & Soluble Silica | Compliant per ISO 3696 and ASTM D1193 |
| Particulates (>0.1 µm) | Not specified |
| Feed Water | Municipal tap water |
| Storage Tank Options | 30 L / 60 L / 100 L (PE, cylindrical with conical bottom, CO₂-absorbing air filter) |
| Data Logging | 1-year automatic水质 history |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix Reference |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Contamination | <10 CFU/mL (with optional UV lamp) |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rios Essential |
| Price Range | USD 6,800–13,600 (est.) |
| Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | >0.05 MΩ·cm (at 25 °C) |
| Total Organic Carbon (TOC) | <200 ppb |
| Particulates (>0.1 µm) | Not Specified |
| Microbial Content | Not Specified |
| Heavy Metals & Soluble Silica | Not Specified |
| Ion Rejection Rate | >95% |
| Organic & Particle Rejection Rate | >99% |
| Flow Rates | 5 / 8 / 16 / 24 L/h (±15%, at 7–35 °C) |
| Daily Output Capacity | 30–480 L (model-dependent) |
| Recovery Rate | 25.0–44.4% (model-dependent) |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | RiOs 30/50/100/150/200 |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | >10 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <30 ppb |
| Feed Water Conductivity | <2000 µS/cm @ 25°C |
| Feed Pressure | 2–6 bar |
| Minimum Flow Rate | >5 L/min @ 2 bar |
| Recovery Rate | Adjustable RO system with reject water recirculation |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Model | IX7003 / IX7005 / IX7010 / IX7015 |
| Purified Water Grade | ASTM Type II |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <1 ppb |
| Total Organic Carbon (TOC) | ≤30 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | AFS E Large |
| Pure Water Grade | Type II (ASTM D1193-20, CLSI C3-A4, NCCLS C3-A3) |
| Compliance | CAP, ISO 15189, CNAS, GLP/GMP-ready |
| Technology | Integrated RO + Elix® Continuous Electrodeionization (CEDI) + Dual UV (185/254 nm) + E.R.A.™ Adaptive Recovery Algorithm |
| Data Logging | 2-year automatic electronic audit trail |
| Remote Access | Web-enabled via Ethernet/Wi-Fi |
| Power & Water Optimization | Smart RO with real-time feedwater adaptation |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Reference |
| Flow Rate | 50–2000 mL/min |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | <5 ppb |
| Particles (>0.22 µm) | <1 particle/mL |
| Microbial Count | <0.1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| UV Lamps | Dual-wavelength (185 nm & 254 nm) |
| Conductivity Sensors | 2 built-in |
| Noise Level | <40 dB at 1 m |
| Display | LCD with Chinese interface |
| Data Logging | 12-month traceable water quality history |
| Compliance | ASTM D1193 Type I, NCCLS, CAP, GLP, ISO 9001/ISO 14001 certified |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Elix 20 |
| Pure Water Grade | ASTM Type II (Analytical Grade) |
| Resistivity | >5 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Contamination | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Maximum Daily Output | 4,000 L |