- All
- Favorite
- Popular
- Most rated
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 |
| Temperature Range | RT to 1600 °C |
| Mass Resolution | Sub-microgram |
| Automation | Integrated Robotic Sample Changer |
| 炉 Atmosphere Control | Hermetic Furnace Design |
| Coupling Compatibility | MS and FTIR for Evolved Gas Analysis |
| Modular Architecture | Field-upgradable Hardware Modules |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 1 |
| Temperature Range | –150 °C to 700 °C |
| Sensor Configuration | 56- or 120-pair star-arranged thermocouples |
| Optional Modules | UV-DSC, HP-DSC (up to 100 bar / down to 10 mbar), DSC-Microscopy System |
| Autosampler Capacity | Up to 34 samples |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | Programmable (5 min to Tmax from 50 °C) |
| Cooling Time (Tmax to 50 °C) | 6 min |
| Capillary Capacity | 6 melting point capillaries per run |
| Sample Throughput | Up to 12 measurements per user session |
| Display | 7-inch full-color touchscreen |
| Video Resolution | High-definition color video recording (300 min total storage) |
| Data Export | SD card, USB drive, or direct PC connection |
| Compliance | 21 CFR Part 11 and EU Annex 11 (with LabX software) |
| Audit Trail | Available via LabX software |
| Report Format | PDF (60 stored reports) |
| Reference Substance Library | 100 entries |
| Dimensions (W × H × D) | 18 × 35 × 19 cm |
| Weight | 4 kg |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Russian, Japanese, Korean |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1 to 20 °C/min |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200 °C to Tmax) |
| Sample Capacity | Up to 4 samples |
| Display | 5.7" VGA color touch screen |
| Video Resolution | Color AVI, >6× magnification |
| Data Export | PDF reports, GLP/GMP-compliant audit trail |
| Compliance | 21 CFR Part 11 ready (with LabX software) |
| Power Consumption | 120 W |
| Dimensions | 18 × 35 × 19 cm |
| Weight | 4.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DMA/SDTA861 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | −150 to 500 °C |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 N |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA861e |
| Temperature Range | −150 to 600 °C (standard), up to 1100 °C with gas-tight furnace option |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 mN |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Resolution | 1 nm |
| Measurement Modes | Static TMA, Dynamic Load TMA (DLTMA), Simultaneous Differential Thermal Analysis (SDTA) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C200 |
| Measurement Modes | Isothermal, Fast Dynamic, Manual, Time-Controlled |
| Standards Compliance | DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711 |
| Max Energy Range | 40,000 J |
| Operating Voltage | 24 V DC (instrument), 100–240 V AC / 50–60 Hz (external power supply) |
| Power Consumption | ≤100 W (calorimeter), ≤120 W (system) |
| Dimensions (W×D×H) | 400 × 400 × 400 mm |
| Weight | 21 kg |
| Protection Class | IP21, Class III |
| Ambient Conditions | 20–25 °C, ≤80 % RH, up to 2,000 m altitude |
| Interfaces | 1× RS-232, 1× Centronics parallel port |
| Software | Calwin C 5040 (real-time monitoring, data export to Excel/Word) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC |
| Temperature Range | –95 to 450 °C |
| Heating/Cooling Rates | Up to 10⁶ K/s (heating), up to 10⁵ K/s (cooling) |
| Sensor Response Time | < 1 ms |
| Sample Mass Range | 1–500 ng |
| Compliance | ISO 11357, ASTM E794, ASTM E1269, USP <1151>, FDA 21 CFR Part 11 (with optional software module) |
Show next