BrandMETTLER TOLEDO
OriginSwitzerland
ModelTGA/DSC 1
Temperature RangeRT to 1600 °C
Mass ResolutionSub-microgram
AutomationIntegrated Robotic Sample Changer
炉 Atmosphere ControlHermetic Furnace Design
Coupling CompatibilityMS and FTIR for Evolved Gas Analysis
Modular ArchitectureField-upgradable Hardware Modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDSC 1
Temperature Range–150 °C to 700 °C
Sensor Configuration56- or 120-pair star-arranged thermocouples
Optional ModulesUV-DSC, HP-DSC (up to 100 bar / down to 10 mbar), DSC-Microscopy System
Autosampler CapacityUp to 34 samples
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginGermany
ModelMP90
Temperature RangeAmbient to 400 °C
Heating RateProgrammable (5 min to Tmax from 50 °C)
Cooling Time (Tmax to 50 °C)6 min
Capillary Capacity6 melting point capillaries per run
Sample ThroughputUp to 12 measurements per user session
Display7-inch full-color touchscreen
Video ResolutionHigh-definition color video recording (300 min total storage)
Data ExportSD card, USB drive, or direct PC connection
Compliance21 CFR Part 11 and EU Annex 11 (with LabX software)
Audit TrailAvailable via LabX software
Report FormatPDF (60 stored reports)
Reference Substance Library100 entries
Dimensions (W × H × D)18 × 35 × 19 cm
Weight4 kg
Language SupportEnglish, Chinese, German, Spanish, French, Italian, Portuguese, Russian, Japanese, Korean
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
Temperature RangeRT to 350 °C
Heating Rate0.1 to 20 °C/min
Temperature Accuracy±0.2 °C (30–200 °C), ±0.5 °C (200 °C to Tmax)
Sample CapacityUp to 4 samples
Display5.7" VGA color touch screen
Video ResolutionColor AVI, >6× magnification
Data ExportPDF reports, GLP/GMP-compliant audit trail
Compliance21 CFR Part 11 ready (with LabX software)
Power Consumption120 W
Dimensions18 × 35 × 19 cm
Weight4.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelDMA/SDTA861
Instrument TypeDynamic Mechanical Analyzer (DMA/DMTA)
Temperature Range−150 to 500 °C
Temperature Accuracy±0.5 °C
Force Range0.001–40 N
Displacement Range±1.6 mm
Frequency Range0.001–1000 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelTMA/SDTA861e
Temperature Range−150 to 600 °C (standard), up to 1100 °C with gas-tight furnace option
Temperature Accuracy±0.5 °C
Force Range0.001–40 mN
Displacement Range±1.6 mm
Frequency Range0.001–1000 Hz
Resolution1 nm
Measurement ModesStatic TMA, Dynamic Load TMA (DLTMA), Simultaneous Differential Thermal Analysis (SDTA)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelC200
Measurement ModesIsothermal, Fast Dynamic, Manual, Time-Controlled
Standards ComplianceDIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
Max Energy Range40,000 J
Operating Voltage24 V DC (instrument), 100–240 V AC / 50–60 Hz (external power supply)
Power Consumption≤100 W (calorimeter), ≤120 W (system)
Dimensions (W×D×H)400 × 400 × 400 mm
Weight21 kg
Protection ClassIP21, Class III
Ambient Conditions20–25 °C, ≤80 % RH, up to 2,000 m altitude
Interfaces1× RS-232, 1× Centronics parallel port
SoftwareCalwin C 5040 (real-time monitoring, data export to Excel/Word)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelFlash DSC
Temperature Range–95 to 450 °C
Heating/Cooling RatesUp to 10⁶ K/s (heating), up to 10⁵ K/s (cooling)
Sensor Response Time< 1 ms
Sample Mass Range1–500 ng
ComplianceISO 11357, ASTM E794, ASTM E1269, USP <1151>, FDA 21 CFR Part 11 (with optional software module)