- All
- Favorite
- Popular
- Most rated
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | G-L |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | 0 / 800 – 15,700 rpm |
| Max RCF | 16,500 × g |
| Max Capacity | 12 × 1.5 / 2.0 mL tubes |
| Rotor Compatibility | Optional 0.4 / 0.5 mL microtubes and PCR strips |
| Timer Range | 20 s – 99 min 59 s (1 s increment) |
| Speed Accuracy | ±5% |
| Acceleration/Deceleration | Programmable |
| Safety Features | Automatic lid lock, imbalance detection, emergency stop, metal rotor cover |
| Rotor Exchange | Tool-free |
| Memory | 9 user-programmable protocols |
| Interface | USB for firmware updates |
| Ingress Protection | IP20 (DIN EN 60529) |
| Dimensions | 200 × 140 × 280 mm |
| Weight | 3.9 kg |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti JXN-26 |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | Up to 26,000 rpm |
| Max RCF | 82,000 × g |
| Max Capacity | 6 L |
| Rotor Configuration | Fixed-angle rotors standard |
| Sample Class | Cells and bacteria |
| Dimensions (W×D×H) | 86 × 71 × 86 cm |
| Compliance | Designed for GLP/GMP-aligned workflows, 21 CFR Part 11–ready software architecture |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Microfuge 16 |
| Centrifuge Type | Benchtop Centrifuge |
| Speed Range | 0–14,800 rpm |
| Max RCF | 16,163 × g |
| Max Capacity | 24 × 2.2 mL |
| Dimensions (W×D×H) | 266 × 266 × 176 mm |
| Rotor Configuration | Fixed-angle rotor with dual-row asymmetric bore geometry |
| Tube Compatibility | 0.2–2.2 mL microtubes |
| Acceleration Time | 13 s (0–14,800 rpm) |
| Deceleration Time | 11 s (14,800 rpm → 0) |
| Motor Type | Brushless induction motor |
| Rotor Sterilization | Autoclavable (121 °C, 20 min) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Allegra 25R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 15,000 rpm (rotor-dependent) / 5,700 rpm (rotor-dependent) |
| Max RCF | 25,160 × g / 6,130 × g |
| Max Capacity | 6 × 250 mL or 4 × 500 mL |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W × D × H) | 40.5 × 65 × 68.5 cm |
| Drive System | Brushless Induction Motor |
| Door Operation | Automatic Lid Locking |
| Sample Volume Range | 0.25 mL to 500 mL |
| Primary Application Domain | Nucleic Acid Purification, Bacterial & Cellular Pellet Recovery, Clarification of Lysates |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–16,000 rpm |
| Max RCF | 23,511 × g |
| Max Capacity | 4 × 400 mL |
| Temperature Range | –20 °C to +40 °C |
| Cooling | Eco-friendly refrigerant (R-134a) |
| Dimensions (W×D×H) | 46 × 55 × 35.5 cm |
| Certified Biosafety Rotors | Fixed-angle & swing-bucket rotors compliant with ISO 15189 and CLSI guidelines |
| Brand | Beckman Coulter |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Allegra C-34R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Cooling Function | Refrigerated |
| Configuration | Horizontal Rotor |
| Separation Level | Cellular & Bacterial |
| Maximum Capacity | 6 × 100 mL |
| Maximum Speed | 22,500 rpm |
| Maximum RCF | 34,020 × g |
| Dimensions (W×D×H) | 38.0 × 67.0 × 33.5 cm (closed) / 38.0 × 67.0 × 73.0 cm (lid open) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | ProteomeLab™ XL-A/XL-I |
| Instrument Type | Floor-standing Analytical Ultracentrifuge |
| Speed Range | Up to 70,000 rpm |
| Maximum RCF | 601,000 × g |
| Dimensions | 94 × 68.1 × 125.7 cm |
| Detection Systems | UV-Vis (XL-A: 190–800 nm) or Interference Optics (XL-I) |
| Sample Capacity | Up to 21 cells simultaneously |
| Vacuum System | High-efficiency dehydration-type |
| Power Consumption | 3.4 kW/h |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Safety Features | Dynamic rotor inertia monitoring, hermetic vacuum drive, HEPA-filtered exhaust |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing centrifuge |
| Category | Refrigerated high-speed centrifuge |
| Max Speed | 26,000 rpm |
| Max RCF | 82,000 × g |
| Max Capacity | 4 × 1000 mL |
| Drive System | Switched Reluctance Motor |
| Cooling Range | –10 °C to +40 °C |
| Heat Dissipation | ≤2.0 kW/h |
| Rotor Options | >30 interchangeable rotors including fixed-angle, swinging-bucket, continuous-flow, and microplate carriers |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Cooling | Refrigerated (2–30 °C) |
| Display | 15-inch capacitive touchscreen |
| Voltage Range | 180–264 VAC (auto-sensing) |
| Power Consumption (standby) | <60 W |
| Noise Level | <51 dBA |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP traceability features, ISO 13485-aligned design |
| Software | eXPert Centrifuge Software v5.x |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Microfuge 16 / Microfuge 18 / Microfuge 22R |
| Refrigeration | Yes (Microfuge 22R only) |
| Max RCF | 16,160 × g (Microfuge 16), 18,000 × g (Microfuge 18), 21,920 × g (Microfuge 22R) |
| Max Speed | 14,000 rpm (Microfuge 16), 14,800 rpm (Microfuge 18 & 22R) |
| Capacity | 3 × 1.5 mL (Microfuge 16), 24 × 1.5 mL (Microfuge 18 & 22R) |
| Temperature Range | –20 °C to +40 °C (Microfuge 22R) |
| Noise Level | ≤58 dBA |
| Acceleration/Deceleration Profiles | 10 selectable rates |
| Run Time | Up to 9 h 59 min continuous or short-spin mode |
| Balance Correction Range (ARIES) | ±50 g |
| Rotor Compatibility | 20 interchangeable rotors |
| Motor Type | Brushless DC drive |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model Series | Optima L-100XP, L-80XP, L-100K, L-90K |
| Max RCF | 802,400 × g (L-100XP/L-100K), 602,000 × g (L-80XP), 694,000 × g (L-90K) |
| Max Speed | 100,000 rpm (L-100XP/L-100K), 80,000 rpm (L-80XP), 90,000 rpm (L-90K) |
| Temperature Control Accuracy | ±0.3 °C (L-100XP), ±0.5 °C (L-80XP/L-100K/L-90K) |
| Software | eXPert Centrifuge Software (full version) |
| Vacuum System | Oil-free, dehydration-based |
| Motor Drive | Hermetically sealed vacuum drive |
| Safety | Dynamic rotor inertia monitoring, automatic rotor recognition, HEPA-filtered exhaust |
| Compliance | Designed for GLP/GMP environments |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing centrifuge |
| Cooling Function | Refrigerated |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 53,300 × g |
| Maximum Capacity | 4 L |
| Dimensions (H×W×D) | 91.4 cm × 63.5 cm × 80.0 cm |
| Drive System | Microprocessor-controlled variable reluctance drive |
| Friction Reduction | Intelligent vacuum-assisted FRS (Friction Reduction System) |
| Refrigerant | CFC-free eco-friendly refrigerant |
| Timer Range | 1 min – 99 hr 59 min, continuous operation |
| Noise Level | < 64 dBA |
| Heat Output | 2.0 kW (6,900 BTU/hr) |
| Weight | 267.4 kg |
| Humidity Limit | < 95% RH |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Equipment Type | Benchtop Refrigerated Centrifuge |
| Model | Allegra X-15R |
| Centrifugation Category | Low-Speed Centrifuge (up to 10,200 rpm) |
| Rotor Configuration | Horizontal (Swinging-Bucket) |
| Maximum Capacity | 6 × 100 mL or 4 × 750 mL |
| Max Speed | 10,200 rpm (for microtubes) / 4,750 rpm (for 750 mL bottles) |
| Max RCF | 11,400 × g / 5,250 × g |
| Temperature Range | –10 °C to +40 °C |
| Cooling Time | ≤4 min (from ambient to +4 °C) |
| Dimensions (W × H × D) | 34.3 × 76.2 × 62.2 cm |
| ARIES™ Auto-Balancing Rotor Capability | ±50 g imbalance tolerance |
| Compliance | Designed for GLP/GMP environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | mini G |
| Instrument Type | Benchtop Microcentrifuge |
| Speed | 6000 rpm |
| Max Capacity | 8 × 2.0 mL |
| Dimensions | 155 × 105 × 175 mm |
| Weight | 1.4 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Input Power | 12 W |
| Protection Class | IP30 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % |
| Acceleration | 2000 × g |
| Rotor Type | Fixed-angle rotor |
| Timer Range | 1–99 min |
| Timer Display | LED |
| Auto-Rotor Recognition | No |
| Quick-Stop Function | Yes |
| Lid Safety Interlock | Yes |
| Tool-Free Rotor Exchange | Yes |
| Noise Level | <45 dB(A) |
| Continuous Operation Duty Cycle | 100 % |
| Compliance | DIN EN 60529, IEC 61010-1 |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Microfuge 20 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Maximum RCF | 20,627 × g |
| Maximum Capacity | 36 × 1.5/2.0 mL tubes |
| Temperature Control | Non-refrigerated (Microfuge 20) |
| Rotor Options | 4 interchangeable fixed-angle rotors including biocontainment-certified rotor |
| Dimensions (W×D×H) | 31 × 42 × 27 cm |
| Compliance | Meets IEC 61010-1 safety standards |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Product Category | Imported Benchtop Centrifuge |
| Model | Allegra X-12 |
| Centrifuge Type | Low-Speed Centrifuge (max. 10,200 rpm) |
| Rotor Configuration | Horizontal Swing-Bucket Rotor |
| Sample Capacity | 6 × 100 mL or 4 × 750 mL |
| Max Speed | 10,200 rpm (fixed-angle) / 3,750 rpm (swing-bucket) |
| Max RCF | 11,400 × g (fixed-angle) / 3,270 × g (swing-bucket) |
| Dimensions | 34.3 × 76.2 × 62.2 cm (W × H × D) |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Product Category | Imported |
| Model | Allegra 64R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Max RCF | 64,400 × g |
| Max Capacity | 510 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W×D×H) | 38 × 61 × 66 cm |
| Rotor Compatibility | 13 interchangeable rotors (11 fixed-angle, 2 swing-bucket) |
| Sample Vessel Range | 0.25–85 mL |
| Acceleration/Deceleration Profiles | 10 programmable settings |
| Timer Range | 1 min–9 h 59 min or continuous/short-run mode |
| Display | Digital LCD with real-time RPM/RCF conversion |
| Drive System | Brushless induction motor |
| Safety Features | Automatic rotor recognition, imbalance detection, overspeed protection, biocontainment swing buckets, interlocked safety lid, stainless-steel chamber ring |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti J-26S XP |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | Up to 26,000 rpm |
| Maximum RCF | 82,000 × g |
| Maximum Capacity | 6 L |
| Dimensions (W×D×H) | 86 × 71 × 86 cm |
| Rotor Compatibility | Fixed-angle, swing-bucket, and elutriation rotors |
| Safety Certification | IEC 61010-2-020, UL 61010-2-020, CE marked |
| Temperature Control Range | –10 °C to +40 °C |
| Imbalance Tolerance | ±3 g per bucket (at max speed) |
| Noise Level | ≤59 dBA at 2 m |
| Drive System | Patented Variable Reluctance Drive (VRD) |
| Rotor Recognition | Automatic RFID-based rotor identification |
| Biocontainment | Biosafety-certified rotors, sealed rotor lids, and aerosol-tight centrifuge chamber |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | J6 |
| Maximum RCF | 6,835 × g |
| Maximum Speed | 6,000 rpm |
| Microprocessor Control | Yes |
| Acceleration/Deceleration Rates | 9/9 |
| Programmable Methods | 10 |
| Brushless Drive Motor | Yes |
| Capacity | 6 L (e.g., 12 blood bags, 18 microplates, or 336 RIA tubes) |
| Rotor Compatibility | JS-4.2A, JS-4.2SMA ARIES (auto-balancing within ±50 g), JE-6B & JE-5.0 elutriation rotors |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Range | Up to 100,000 rpm |
| Max RCF | 802,000 × g |
| Max Capacity | 6 × 85 mL |
| Drive System | Refrigerated Brushless Induction Motor |
| Temperature Control | 0–40 °C (±0.5 °C) |
| Power Supply | 180–264 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 94 × 68.1 × 125.7 cm |
| Acoustic Noise Level | <51 dBA |
| Standby Power Consumption | <60 W |
| Compliance | ISO 13485, IEC 61010-1, FDA 21 CFR Part 11 (software-enabled audit trail), GLP/GMP-ready configuration options |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti JXN-30 |
| Instrument Type | Floor-Model Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Max RCF | 110,500 × g |
| Max Capacity | 4 L (4 × 1 L rotors) |
| Cooling Range | -10 °C to +40 °C |
| Dimensions (W×D×H) | 86 × 71 × 86 cm |
| Rotor Compatibility | Fixed-angle, swinging-bucket, JLA series ultra-lightweight rotors |
| Drive System | Variable Reluctance Motor |
| Acceleration/Deceleration Rates | 12/13 steps |
| Timer Range | 0:01–99:59 h, Hold mode, ω²t integration |
| Data Storage | 1,000 user-defined protocols, 50 user accounts, real-time run curve logging |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11 audit trail requirements via optional software modules |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Avanti J-HC |
| Centrifuge Type | Floor-Model Refrigerated Centrifuge |
| Speed Range | 10,000 rpm |
| Max RCF | 17,700 × g |
| Max Capacity | 9 L |
| Dimensions (H×W×D) | 86 cm × 71 cm × 86 cm |
| Drive System | Microprocessor-Controlled Variable-Reluctance Drive |
| Vacuum-Assisted Bearing System | Intelligent Vacuum Lubrication |
| Refrigerant | CFC-Free Eco-Friendly Refrigerant |
| Timer Range | 1 min – 99 hr 59 min (including continuous mode) |
| Programs | 30 Dual-Step Protocols |
| Heat Output | 2.0 kW (6,900 BTU/hr) |
| Sound Level | < 60 dB(A) |
| Weight | 300 kg |
| Relative Humidity Limit | < 95% non-condensing |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | Allegra X-30 / Allegra X-30R |
| Maximum Capacity | 4 × 400 mL (horizontal rotor) or 6 × 85 mL (fixed-angle rotor) |
| Maximum Speed | 18,000 rpm |
| Relative Centrifugal Force (RCF) | 29,756 × g |
| Temperature Range | –20 °C to +40 °C |
| Cooling Time | ≤10 min to reach 4 °C from ambient |
| Dimensions (H × W × D) | 550 × 355 × 460 mm |
| Drive Type | Brushless Induction Motor |
| Acceleration/Deceleration Profiles | 10 independent settings each |
| Safety Features | Automatic door interlock, real-time imbalance detection, reinforced steel perimeter containment ring |
| Noise Level | <65 dBA at maximum speed |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F0650 |
| Instrument Type | Benchtop Centrifuge |
| Maximum Capacity | 6 × 50 mL |
| Maximum Speed | 21,000 rpm (with Allegra 64R) |
| Maximum RCF | 41,400 × g (with Allegra 64R) |
| Rotor Type | Fixed-Angle |
| k-Factor | 795 |
| BioC Certification | Not Applicable |