| Brand | Roche Diagnostics |
|---|---|
| Origin | Switzerland |
| Instrument Type | Digital PCR System |
| Model | Roche Digital LC |
| Regulatory Status | CE-IVD, FDA-cleared for in vitro diagnostic use (where applicable) |
| Compliance | ISO 13485, IVD Directive 98/79/EC, aligned with CLIA and CAP laboratory requirements |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniSeq |
| Instrument Class | Next-Generation Sequencing (NGS) Platform |
| Medical Device Classification | Non-Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 2 × 150 bp |
| Throughput | Up to 25 Gb per run |
| Run Time | ~17–32 hours depending on workflow |
| Supported Applications | Targeted sequencing, small RNA-seq, amplicon sequencing, gene expression profiling, and microbiome analysis |
| Library Prep Compatibility | Illumina-compatible library kits (e.g., TruSight, Nextera XT, RNA Prep with Enrichment) |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | iSeq 100 |
| Instrument Category | Next-Generation Sequencing (NGS) Platform |
| Regulatory Status | Not a Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 2 × 150 bp |
| Throughput | Up to 4 million reads per run |
| Accuracy | ≥99.5% Q30 at 2 × 150 bp |
| Run Time | ~17 hours for 2 × 150 bp sequencing |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | NovaSeq X |
| Instrument Category | Next-Generation Sequencing (NGS) Platform |
| Medical Device Classification | Not a Medical Device (Research-Use-Only) |
| Form Factor | Benchtop High-Throughput Sequencer |
| Read Length | 2 × 150 bp (paired-end) |
| Output per Run | Up to 8 Tb (NovaSeq X), up to 16 Tb (NovaSeq X Plus, dual flow cell) |
| Throughput per Flow Cell | Up to 26 billion single-end reads |
| Chemistry | XLEAP-SBS (eXtended LEAP – Sequencing by Synthesis) |
| Run Time | ~15–48 hours (dependent on application and read length) |
| Sample Input Capacity | Scalable from 165 Gb to 16 Tb per run |
| Integrated Bioinformatics | On-instrument DRAGEN Bio-IT Platform (supports concurrent execution of up to four secondary analysis pipelines per flow cell) |
| Data Output Format | Variant Call Format (VCF) and other standardized genomic outputs (e.g., BAM, CRAM) directly generated onboard |
| Brand | Roche Diagnostics |
|---|---|
| Origin | Switzerland |
| Model | LightCycler 480 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well plate or 8-tube strip |
| Heating Rate | 6.8 °C/s |
| Temperature Accuracy | ±0.1 °C (37–99 °C) |
| Well-to-Well Temperature Uniformity | ±0.1 °C (37–99 °C) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ExoCounter |
| Price Range | USD 7,000 – 14,000 |
| Instrument Category | Ultra-Micro Nucleic Acid and Protein Analyzer |
| Sample Volume | 12.5 µL |
| Counting Speed | >200,000 events/sec |
| Throughput | 16 samples per 15 min (single disc) |
| Linear Detection Range | 1×10⁶ – 3×10⁸ particles/mL |
| Detection Principle | Digital immunoassay coupled with Blu-ray optical disc-based microfluidic separation and fluorescence counting |
| Dimensions (Analyzer) | 210 mm (W) × 297 mm (D) × 250 mm (H) |
| Dimensions (Washer Module) | 210 mm (W) × 330 mm (D) × 350 mm (H) |
| Software | Proprietary data acquisition and analysis suite with CSV export capability |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Roche Diagnostics |
|---|---|
| Origin | Switzerland |
| Model | LightCycler® 96 |
| Instrument Type | Real-Time Quantitative PCR System |
| Sample Throughput | 96-well plate or 8-tube strip |
| Heating Rate | 6.8 °C/s |
| Temperature Accuracy | ±0.2 °C (37–98 °C) |
| Well-to-Well Temperature Uniformity | ±0.2 °C (37–98 °C) |
| Excitation Source | High-Stability White LED (Lifespan >20,000 h) |
| Optical Architecture | Dual 96-channel Fiber-Optic Detection System |
| Cycle Time | <60 min for 40 cycles |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (P.R.C.-assembled) |
| Model | NovaSeq 6000 |
| Instrument Class | Next-Generation Sequencing (NGS) Platform |
| Regulatory Status | Not a Medical Device (Non-IVD) |
| Form Factor | Benchtop High-Throughput Sequencer |
| Output Capacity | Up to 6 Tb per run |
| Read Yield | Up to 20 billion reads per run |
| Run Time | 3–5 hours (for rapid kits) |
| Read Length Configurations | 2 × 50 bp, 2 × 100 bp, 2 × 150 bp, and 2 × 250 bp (paired-end) |
| Flow Cell Options | S1, S2, S4, and SP flow cells (single or dual flow cell loading) |
| Compatibility | Illumina-compatible library prep kits (e.g., TruSight, Nextera, NovaSeq Xp) |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Megaruptor®3 |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Throughput | Up to 24 samples per run |
| Sample Volume Range | 20–200 µL |
| Processing Time per Batch | 15–45 minutes |
| Fragment Size Range | 2–75 kb |
| Display | Integrated 7-inch capacitive touchscreen |
| Cross-Contamination Control | Non-contact fluidic shearing |
| Compliance | Designed for GLP-compliant workflows, compatible with ISO/IEC 17025 laboratory accreditation requirements |
| Brand | Illumina |
|---|---|
| Origin | Shanghai, China |
| Model | NextSeq 1000/1000-CN |
| Instrument Type | Short-Read Sequencing Platform (Illumina SBS Chemistry) |
| Read Length | Up to 2 × 150 bp |
| Output per Flow Cell | Up to 30 Gb (P1), 120 Gb (P2), 360 Gb (P3) |
| Q30 Score | ≥85% at 2 × 150 bp |
| Run Time | ~19–48 hours depending on read length and flow cell type |
| Flow Cell Compatibility | P1, P2, P3 (P3 limited to NextSeq 2000/2000-CN) |
| On-Instrument Secondary Analysis | Integrated DRAGEN Bio-IT FPGA Accelerator |
| Laser Wavelengths | 449 nm, 523 nm, 820 nm |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 20–80% non-condensing |
| Altitude Limit | ≤2000 m |
| Safety Classification | Class 1 Laser Product |
| Compliance | IEC 61010-1, CE, FCC/IC, NRTL certified |