- All
- Favorite
- Popular
- Most rated
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 N |
| Measurement Principle | High-Temperature Combustion Coupled with Chemiluminescence (N), UV-Fluorescence (S), and Microcoulometric Titration (Cl/Br) |
| Detection Limits | Sub-ppb for N and S in liquid/gas matrices |
| Analysis Time | 2–5 min per sample |
| Sample Types | Liquids, Gases, LPG, LNG, Solids (with optional solid module) |
| Automation | Unattended 24/7 operation with remote monitoring capability |
| Dimensions | < 0.3 m² footprint |
| Interface | Integrated 10.1" capacitive touchscreen with intuitive GUI |
| Detection Technology | HiPerSens™ optimized signal processing |
| Compliance | Designed to meet ISO 14852, ISO 14855, ASTM D5762, D7183, D7556, USP <381>, and EPA Method 524/525/5310C requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S900 |
| Instrument Type | Portable |
| Measurement Range | 0–50 mg/L |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.05 mg/L |
| Detection Limit | 0 mg/L |
| Sensor Interface | Digital (InLab® OptiOx) |
| Channel Configuration | Single-channel, modularly expandable |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi N/C 3100 |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 4 ppb C |
| Repeatability | ≤1% RSD |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 SMPO |
| Detection Principle | High-Temperature Combustion Coupled with UV Fluorescence Detection (S) / Chemiluminescence Detection (N) |
| Detection Limits | S: 5 ppb, N: 10 ppb |
| Linear Dynamic Range | 5 ppb – 50,000 ppm (S), auto-ranging |
| Sample Types | Liquid fuels (gasoline, diesel, jet fuel), LPG, LNG, refinery streams, crude oil fractions, aqueous extracts |
| Compliance | ASTM D5453, D7039, D7183, ISO 20846, ISO 20884, UOP 390, IP 520, SH/T 0689, GB/T 11141, EN 15486 |
| Automation | Optional 18-position or 120-position autosamplers |
| Software | EAsy Control v3.x with 21 CFR Part 11 compliance mode, audit trail, electronic signatures, method library, remote monitoring |
| Dimensions | < 0.3 m² footprint (integrated combustion unit, detector, controller, autosampler base) |
| Safety | EAsy Protect real-time system parameter monitoring, HiPerSens high-sensitivity detection module, glove-compatible nano-coated touchscreen |
Show next