- All
- Favorite
- Popular
- Most rated
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD300 |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 155 W / 310 W (dual-step adjustable) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Throughput | ≥24 samples per run |
| Processing Chamber Volume | 750 mL |
| Dimensions (Controller) | 150 × 300 × 195 mm (W×D×H) |
| Dimensions (Processing Chamber) | 350 × 260 × 150 mm (W×D×H) |
| Weight | 20 kg |
| Timer Range | 0–60 sec or 0–15 min (on/off cycles) |
| Compatible Vessels | PCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes |
| Fragmentation Range (DNA) | 2 kb – <500 bp |
| Rotation Speed | Programmable constant-speed rotation during sonication |
| Compliance | CE-marked |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Loopster |
| Speed Range | 5–80 rpm |
| Adjustable Rotation Angle | 0°–90° |
| Timer Range | 1 s–5999 min |
| Platform Capacity | 2 kg (including fixtures) |
| Operating Temperature | 4–50 °C |
| Protection Class | IP21 |
| Dimensions (W×D×H) | 300 × 360 × 300 mm |
| Weight | 3 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Display | 7-segment LED |
| Speed Resolution | 1 rpm per step |
| Duty Cycle | Continuous operation supported |
| Platform Stackable | No |
| USB/RS232/Analog Output | None |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 501 Digital |
| Drive Type | Reciprocal & Circular Orbital |
| Orbit Diameter | 30 mm |
| Speed Range | 0–300 rpm |
| Speed Display | LED Digital |
| Load Capacity (incl. clamps) | 15 kg |
| Timer Range | 1–56 min |
| Timer Display | Analog Scale |
| Operating Mode | Timed or Continuous |
| Input Power | 74 W |
| Motor Input Power | 70 W |
| Motor Output Power | 19 W |
| Duty Cycle | 100 % continuous operation |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 (DIN EN 60529) |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Dimensions (W × H × D) | 505 × 120 × 585 mm |
| Weight | 26 kg |
| Clamp Assembly | Not included — ordered separately |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | VXR Basic Vibrax |
| Oscillation Mode | Orbital |
| Orbit Diameter | 4 mm |
| Speed Range | 0–2200 rpm |
| Load Capacity (incl. clamp) | 2 kg |
| Motor Input/Output Power | 35 / 13.2 W |
| Operating Mode | Continuous |
| Display Type | Analog Scale |
| Dimensions (W × D × H) | 157 × 247 × 130 mm |
| Weight | 6.1 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection Rating | IP21 |
| Compliance | DIN EN 60529 |
| Brand | Zhichu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-VCN |
| Instrument Type | CO₂-Controlled Temperature-Regulated Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Ø50 mm) |
| Oscillation Amplitude | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Number of Shaking Platforms | 3 |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| CO₂ Control Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % |
| Display | LCD Touchscreen |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| Noise Level | <55 dB(A) |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-CS9 |
| Instrument Type | CO₂-Controlled Temperature-Shaking Incubator |
| Stacking Configuration | 3-Layer Modular Stack |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Φ50 mm platform) |
| Oscillation Amplitude | Φ50 mm (standard), Φ26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Range | Ambient to 90 % RH |
| Humidity Accuracy | ±5 % RH |
| Humidity Resolution | 1 % RH |
| CO₂ Range | 0–20 % |
| CO₂ Accuracy | ±0.1 % (IR sensor) |
| CO₂ Decay Time | 30 min (5.0 % → 4.5 %) |
| Platform Dimensions (L×W) | 1000 × 530 mm per layer |
| Max Capacity (per layer, stainless steel clamps) | 250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 18 |
| Max Capacity (per layer, polymer clamps) | 250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 15 |
| Noise Level | <55 dB(A) |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| External Dimensions (W×D×H) | 1430 × 845 × 1740 mm (3-layer) |
| Net Weight | ~728 kg |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | new pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4 °C to ambient |
| Maximum Sample Capacity | 16 tubes |
| Sample Volume Range | 20 µL – 2 mL |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Brand | Zhilchu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZCZY-CSR8 |
| Instrument Type | CO₂-Controlled Temperature-Shaking Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Φ50 mm platform) |
| Oscillation Amplitude | Φ50 mm (standard), Φ26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Number of Shaking Decks | 3 |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Noise Level | <55 dB(A) |
| Max Load Capacity (stainless steel clamp) | 250 mL × 66 / 500 mL × 45 / 1000 mL × 28 / 2000 mL × 15 per deck |
| Deck Dimensions (L×W) | 928 mm × 530 mm |
| External Dimensions (L×W×H) | 1360 mm × 845 mm × 1740 mm (3-deck configuration) |
| Net Weight | ~596 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Hula Dancer digital |
| Instrument Type | Orbital Shaker |
| Oscillation Mode | Circular |
| Orbit Diameter | 4.5 mm |
| Speed Range | 1200–2800 rpm |
| Speed Resolution | Fixed or Adjustable (No Digital Display) |
| Load Capacity (incl. Clamp) | 0.1 kg |
| Temperature Operating Range | 5–40 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Class | IP42 (per DIN EN 60529) |
| Input Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Motor Input Power | 9.5 W |
| Motor Output Power | 5 W |
| Standby Power Consumption | 0.8 W |
| Continuous Operation Rated | 100 % |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Momentary Start Function | Yes |
| Timer | Not integrated |
| Speed Display | None |
| Brand | Zhilu |
|---|---|
| Model | ZCLY-180 |
| Instrument Type | CO₂-controlled incubator shaker |
| Timing Range | 0–999.9 h |
| Oscillation Frequency | 10–300 rpm (±1 rpm) |
| Amplitude | Ø26 mm |
| Temperature Range | 4–60 °C (at ambient 23–25 °C) |
| Temperature Uniformity | ±0.8 °C (at 37 °C) |
| Temperature Resolution | ±0.1 °C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Number of Shaking Platforms | 3 |
| Platform Size (L×W) | 485 × 485 mm |
| Max Capacity per Shelf | 250 mL × 25 / 500 mL × 16 / 1000 mL × 9 |
| Internal Chamber | R-cornered 304 stainless steel, seamless welded |
| Display | LCD touchscreen with real-time multi-parameter overlay |
| Data Logging | 1-min interval, up to 3 months’ storage |
| Connectivity | USB export |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 760 × 680 × 1280 mm |
| Net Weight | ~183 kg |
| Noise Level | <55 dB(A) |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-VCS8 |
| Instrument Type | CO₂-Regulated Temperature-Controlled Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Ø50 mm), 10–300 rpm (Ø26 mm) |
| Oscillation Amplitude | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient 23–25 °C) |
| Number of Shaking Decks | 3 |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| CO₂ Control Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % |
| CO₂ Decay Time | 30 min (from 5.0 % to 4.5 %) |
| Deck Dimensions (L×W) | 900 × 530 mm |
| Noise Level | <55 dB(A) |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | VORTEX 2 S025 |
| Oscillation Frequency | 50/60 Hz |
| Oscillation Amplitude | 4 mm |
| Operating Temperature Range | 5–40 °C |
| Speed Range | 500–2500 rpm |
| Orbit Diameter | 4 mm |
| Max Load Capacity (incl. attachment) | 0.4 kg |
| Input Power | 60 W |
| Motor Output Power | 9 W |
| Dimensions (W×D×H) | 120 × 140 × 138 mm |
| Weight | 3.9 kg |
| Protection Class | IP21 |
| Voltage | 220–240 V AC, 50/60 Hz |
| Relative Humidity Limit | 80 % RH |
| Continuous Duty Rating | 100 % |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZCZY-CS8 |
| Instrument Type | CO₂-Controlled Temperature-Controlled Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient 23–25 °C) |
| Number of Shaking Platforms | 3 |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX255 / VCX500 / VCX800 |
| Ultrasonic Output Power | 255 W / 500 W / 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Temperature Control Range | 1–100 °C |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Power Input | 220–240 V, 50/60 Hz |
| Brand | Zhichu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZCDY-BS8 |
| Instrument Type | CO₂-Controlled Constant-Temperature Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Number of Shaking Platforms | 2 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Vortex2 |
| Oscillation Frequency | 500–2500 rpm |
| Oscillation Amplitude | 4 mm |
| Platform Quantity | 1 |
| Maximum Load Capacity (including clamp) | 0.4 kg |
| Motor Input/Output Power | 39 / 9 W |
| Dimensions (W × D × H) | 120 × 138 × 140 mm |
| Net Weight | 3.9 kg |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX130AT |
| Instrument Type | Ultrasonic Cell Disruptor |
| Power Output | 130 W |
| Operating Frequency | 20 kHz |
| Maximum Nebulization Rate | 16 L/hr |
| Droplet Size | 45 µm |
| Max. Fluid Viscosity | 60 cP |
| Nebulization Mode | Pressure-Free |
| Probe Replacement Cost | Low |
| Ambient Contamination | Minimal |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-CNH |
| Instrument Type | CO₂-Regulated Temperature-Controlled Orbital Shaker Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–1000 rpm (±1 rpm accuracy) |
| Oscillation Amplitude | Φ3 mm |
| Temperature Range | 4–60 °C (ambient 23–25 °C) |
| Number of Shaking Decks | 3 |
| CO₂ Control Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Resolution | ±0.1 °C |
| Deck Dimensions (L×W) | 435 × 298 mm per deck (dual-motor per deck) |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| Noise Level | <55 dB(A) |
| Internal Chamber | R-cornered 304 stainless steel |
| CO₂ Leak Rate | 5 % → 4.5 % in 30 min |
| Humidity Range (optional) | Ambient to 90 % RH (at 37 °C) |
| Data Logging | 5-year internal storage with temperature, RPM, and CO₂ concentration trend curves |
| Interface | Touchscreen LCD with USB data export |
| Compliance | Designed for GLP-compliant cell culture workflows |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VC255 / VC505 / VC800 |
| Output Power | 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Sealed Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Timer Range | 0–99 min 59 sec (microprocessor-controlled) |
| Pulse Mode | Adjustable 1–59 sec ON/OFF cycles |
| Remote Control Capability | Yes |
| Input Voltage | 220–240 V, 50/60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | ROCKER 3D basic |
| Oscillation Angle | 8° |
| Oscillation Amplitude | 30 mm |
| Temperature Range | 4–50 °C |
| Platform Quantity | 1 |
| Maximum Load (incl. fixture) | 2 kg |
| Continuous Operation | 100% duty cycle |
| Fixed Speed | 30 rpm |
| Dimensions (W × D × H) | 280 × 165 × 330 mm |
| Weight | 2.2 kg |
| Protection Rating | IP21 |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Power Consumption | 24 W |
| Operating Ambient Temperature | 4–50 °C |
| Relative Humidity Limit | 80 % |
| Stackable Platforms | Yes (30 mm height increment) |
| Slip-Resistant Rubber Mat | Included |
| Touch Control Interface | Yes |
| USB/RS232/Analog Output | None |
| Timer Function | None |
| Speed Display | None |
| Pulse Mode | No |
| Benchtop Brake | No |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Megaruptor |
| Application | High-Throughput HMW DNA Fragmentation for Long-Read Sequencing Platforms |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | VXR Basic Photoelectric-Controlled Mini Orbital Shaker |
| Timer Range | 10–100 min |
| Oscillation Frequency | 80–200 rpm |
| Orbit Diameter | 4 mm |
| Max Load Capacity (incl. clamps) | 2 kg |
| Operating Temperature Range | 5–40 °C |
| Plate Quantity | 1 |
| Dimensions (W×D×H) | 157 × 130 × 247 mm |
| Weight | 6.1 kg |
| Input Voltage | 220–240 V / 100–120 V, 50/60 Hz |
| Power Consumption | 45 W |
| Protection Class | IP21 (DIN EN 60529) |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Continuous Duty Rating | 100 % |
| Minimum Adjustable Speed | 100 rpm |
| Speed Range | 0–2200 rpm |
| Drive Type | Brushless DC Motor |
| Display | Analog Speed Scale |
| Interface | None |
| Analog Output | None |
| Microplate Compatibility | Not Designed for Microplates |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | KS 3000 i control |
| Timer Range | 1–59940 min |
| Oscillation Frequency | 10–500 rpm |
| Orbit Diameter | 20 mm |
| Temperature Range | RT +5 °C to 80 °C |
| Platform Quantity | 1 |
| Temperature Control Accuracy (with PT1000) | ±0.1 K |
| Temp. Uniformity (5×0.5 L vessels @ 37 °C) | ±0.5 K |
| Temp. Stability (1×0.5 L vessel @ 37 °C) | ±0.05 K |
| Max Load Capacity (incl. clamps) | 7.5 kg |
| Power Input | 1120 W |
| Interface | RS232 & USB |
| IP Rating | IP30 |
| Dimensions (W×D×H) | 465 × 430 × 695 mm |
| Weight | 35 kg |
| Brand | Zhichu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZHTY-70 |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–400 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Shelf Quantity | 3 |
Show next