| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD300 |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 155 W / 310 W (dual-step adjustable) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Throughput | ≥24 samples per run |
| Processing Chamber Volume | 750 mL |
| Dimensions (Controller) | 150 × 300 × 195 mm (W×D×H) |
| Dimensions (Processing Chamber) | 350 × 260 × 150 mm (W×D×H) |
| Weight | 20 kg |
| Timer Range | 0–60 sec or 0–15 min (on/off cycles) |
| Compatible Vessels | PCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes |
| Fragmentation Range (DNA) | 2 kb – <500 bp |
| Rotation Speed | Programmable constant-speed rotation during sonication |
| Compliance | CE-marked |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | new pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4 °C to ambient |
| Maximum Sample Capacity | 16 tubes |
| Sample Volume Range | 20 µL – 2 mL |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX255 / VCX500 / VCX800 |
| Ultrasonic Output Power | 255 W / 500 W / 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Temperature Control Range | 1–100 °C |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Power Input | 220–240 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX130AT |
| Instrument Type | Ultrasonic Cell Disruptor |
| Power Output | 130 W |
| Operating Frequency | 20 kHz |
| Maximum Nebulization Rate | 16 L/hr |
| Droplet Size | 45 µm |
| Max. Fluid Viscosity | 60 cP |
| Nebulization Mode | Pressure-Free |
| Probe Replacement Cost | Low |
| Ambient Contamination | Minimal |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VC255 / VC505 / VC800 |
| Output Power | 800 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 250 µL to several liters |
| Dimensions (H×W×D) | 235 × 190 × 340 mm |
| Weight | 6.8 kg |
| Transducer Type | CV334 Sealed Piezoelectric Converter (PZT) |
| Probe Standard | Φ13 mm Titanium Alloy (Ti-6Al-4V), 136 mm length, 340 g |
| Timer Range | 0–99 min 59 sec (microprocessor-controlled) |
| Pulse Mode | Adjustable 1–59 sec ON/OFF cycles |
| Remote Control Capability | Yes |
| Input Voltage | 220–240 V, 50/60 Hz |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VC800/VCX800 |
| Ultrasonic Output Power | 800 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–100 °C |
| Sample Volume Capacity | 250 µL to several liters |
| Number of Samples per Run | 1 |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX1500 |
| Output Power | 1500 W |
| Operating Frequency | 20 kHz |
| Maximum Continuous Flow Rate | 100 L/h (with optional flow-through chamber) |
| Standard Probe Tip Diameter | 25 mm |
| Probe Material | Titanium Alloy (Grade 5) |
| Cooling | Air-Cooled Transducer |
| Control System | Microprocessor-Based with Real-Time Parameter Display |
| Timer & Pulse Mode | Yes |
| Amplitude Adjustment | Variable (0–100%) |
| Input Power Requirement | 200 V, 50/60 Hz |
| Dimensions (H×W×D) | 279.4 × 380 × 463.5 mm |
| Net Weight | 9.5 kg |
| Transducer Model | CV294 |
| Transducer Dimensions | Ø76.2 mm × 158.7 mm |
| Transducer Weight | 900 g |
| Cable Length | 3 m |
| Compliance | CE, UL Listed |
| Standard Configuration | Host unit, 25 mm probe, tool kit, operator manual |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Pico |
| Ultrasonic Power | 25–210 W |
| Operating Frequency | 20–60 kHz |
| Temperature Range | −20 °C to 40 °C |
| Sample Volume Capacity | 5 µL – 12 mL (dependent on adapter selection) |
| Maximum Simultaneous Samples | 12 |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Fragment Size Range (DNA) | 100 bp – 1 kb |
| Adapter Standard | 0.5 mL tube holder with mechanical locking mechanism |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Plus |
| Instrument Type | Non-contact ultrasonic cell disruptor |
| Sample Capacity | 6–12 tubes (0.5 mL to 50 mL) |
| Cooling | Integrated 4 °C water bath with optional recirculating chiller |
| Control Interface | Digital LCD timer & power selector (Low/High) |
| Safety | Fully sealed tube processing, acoustic shielding enclosure, overheat protection |
| Compliance | Designed for GLP-compliant chromatin shearing and DNA fragmentation workflows per EN ISO 13485-aligned manufacturing standards |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD-300 (Plus) |
| Instrument Type | Non-contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 160–320 W |
| Operating Frequency | 40 kHz (typical, fixed-frequency transducer array) |
| Temperature Range | −20 °C to +40 °C (with optional chiller integration) |
| Sample Volume Capacity | 5 µL – 20 mL (dependent on adapter configuration) |
| Throughput | 1–12 samples per run (6–12 standard with rotating rack |
| Cooling Method | External recirculating chiller or integrated Peltier-assisted bath temperature control |
| Brand | Sonics |
|---|---|
| Origin | USA |
| Model | VCX150PB / VCX150 |
| Output Power | 150 W |
| Frequency | 20 kHz |
| Sample Volume Range | 150 µL – 150 mL |
| Display | Digital Power Readout |
| Control | Microprocessor-Based |
| Pulse Mode | Manual or Programmable (1–59 s ON/OFF, up to 10 h timer) |
| Transducer | CV188 (VCX150PB) / CV18 (VCX150) |
| Probe Options | φ2 mm, φ3 mm, φ6 mm, φ13 mm (Ti-6Al-4V alloy) |
| Dimensions (H×W×D) | 115 × 250 × 320 mm (VCX150PB), 115 × 250 × 320 mm (VCX150) |
| Weight | 3.0 kg (VCX150PB), 3.2 kg (VCX150) |
| Input Voltage | 220–240 V, 50/60 Hz |