| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML54T |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 52 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Stabilization Time | 2 s |
| Minimum Weight (USP <41>) | 120 mg |
| Minimum Weight (U=1%, k=2) | 12 mg |
| Calibration | FACT fully automatic internal calibration |
| Leveling System | LevelControl with on-screen guidance |
| Weighing Pan Dimensions | 90 mm diameter |
| Display | 4.5-inch full-color capacitive touchscreen |
| Connectivity | USB Host, USB Device, RS232, optional Bluetooth |
| Data Transfer | PC Direct mode (no driver or software required) |
| Housing Material | ABS/PC top cover with metal base |
| Environmental Protection | IP42-rated enclosure |
| Power Options | AC adapter or rechargeable Li-ion battery (up to 8 h operation) |
| Compliance | ISO/IEC 17025 traceable calibration records, USP <41> and <1251> compliant, GLP/GMP-ready audit trail (ISO Log), 21 CFR Part 11 compatible with optional software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HPD Handheld Powder Dispenser |
| Capacity Range | 100–200 g |
| Maximum Capacity | 100 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | 1 mg |
| Instrument Type | Precision Powder Dispensing System |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | XSR204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT) |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| Linearity Error (typ.) | ±0.2 mg |
| Dimensions (H × W × D) | 292 mm × 195 mm × 482 mm |
| Connectivity | USB-B, RS232 (integrated/optional), USB-A, Bluetooth (optional), Ethernet (LAN) |
| Compliance | 21 CFR Part 11–ready (with LabX), GLP/GMP-supportive audit trail, password-protected user management |
| Software Compatibility | LabX™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX204/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.05 mg |
| Minimum Weight (U=1%, k=2, typ.) | 10 mg |
| Minimum Weight (USP <41>, ±0.1%, typ.) | 100 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 90 mm |
| Dimensions (H×W×D) | 353 × 222 × 379 mm |
| Protection Rating | IP41 |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Quantos QA |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg |
| Repeatability | 1 mg |
| Liquid Dispensing Range | 1 mg to several grams |
| Compliance | Designed for GLP/GMP environments with full audit trail support |
| Integration | Compatible with XP/XPE analytical balances and QWB workflow software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MS104TS |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120.0 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Minimum Weight (USP <41> typical) | 160.0 mg |
| Calibration | Internal |
| Display | 7-inch full-color capacitive touchscreen |
| Connectivity | USB Host, USB Device, RS232, Bluetooth (optional) |
| Draft Shield | QuickLock removable without tools |
| Security | Password-protected access for calibration and configuration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Quantos QB |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg, 0.01 mg, 5 µg, 1 µg |
| Repeatability | 1 mg |
| Compliance | Designed for GLP/GMP environments, compatible with FDA 21 CFR Part 11–enabled software workflows |
| Integration | Modular upgrade for XP/XPE analytical balances |
| Application Scope | Gravimetric preparation of standards, stock solutions, multi-component reference materials, and final concentration dilutions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Imported Analytical Balance |
| Model | XPE105 |
| Maximum Capacity | 120.0 g |
| Readability | 0.01 mg |
| Minimum Weight (USP) | 14.0 mg |
| Repeatability | 0.015 mg |
| Calibration | Automatic |
| Static Detection & Neutralization | Integrated StaticDetect™ |
| Draft Shield Operation | SmartSens™ Infrared Sensor |
| Software Integration | LabX® Ready |
| Compliance Support | GLP/GMP, USP <41>, <1251>, FDA 21 CFR Part 11 Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Precision Balance |
| Model | ML203T |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ≤ ±1 mg |
| Construction | Stainless steel base with chemical-resistant housing |
| Power Options | AC adapter or rechargeable battery |
| Compliance | ISO/IEC 17025, ASTM E898, USP <41>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX105DU/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 42 g / 120 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability (typ.) | 0.0125 mg |
| Minimum Weight (USP <41>, k=2, 0.1% tolerance, typ.) | 25 mg |
| Minimum Weight (uncertainty U=1%, k=2, typ.) | 2.5 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Certified Readability | 1 mg |
| Compliance | GxP-ready, USP <41>, ISO/IEC 17025 support, FDA 21 CFR Part 11 audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MR204/A |
| Maximum Capacity | 220 g |
| Readability (Certified) | 1 mg |
| Readability (High-Resolution Mode) | 0.1 mg |
| Repeatability (Typical) | 0.08 mg |
| Minimum Weight (USP <41>, k=2, 0.1% tolerance) | 160 mg |
| Minimum Weight (Uncertainty U=1%, k=2, typical) | 16 mg |
| Stabilization Time | 2 s |
| Calibration | Internal, Fully Automatic (FACT) |
| IP Rating | IP43 |
| Display | 4.5-inch color TFT touchscreen |
| Pan Diameter | 90 mm |
| Dimensions (H×W×D) | 354 mm × 209 mm × 351 mm |
| Interfaces | RS232, USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Compliance | USP <41>, ISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (with appropriate software configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ME103 |
| Maximum Capacity | 120 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity Error | ±0.002 g |
| Stabilization Time | 1.5 s |
| Sensitivity Drift | 3.0 ppm/°C |
| Pan Diameter | 120 mm |
| Net Weight | 4.6 kg |
| Calibration | Internal |
| Compliance | ISO/GLP-compliant data logging (date/time stamping) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPE Precision Balance |
| Instrument Type | Precision Balance |
| Capacity Range | 200 g – 64.1 kg |
| Readability | 0.1 mg – 1.0 g |
| Repeatability (typ.) | 0.12 mg – 40.0 mg |
| IP Rating | IP54 |
| Sensor Technology | Monobloc HighSpeed electromagnetic force compensation sensor |
| Compliance | ISO/IEC 17025, USP <41> & <1251>, ASTM E898, GLP/GMP-ready with audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | PL-E Portable Balance |
| Maximum Capacity | 1000 g |
| Readability | 0.1 g (PL1002E/PL8001E/PL6001E) |
| Typical Repeatability | 0.07 g (0.1 g models) / 0.007 g (0.01 g models) |
| Linearity Error | 0.02 g (PL602E) |
| Power Supply | AC adapter or 4 × AA batteries |
| Display | Backlit LCD with large, high-contrast digits |
| Built-in Applications | 10 preprogrammed weighing functions |
| Stackable Design | Up to 5 units vertically |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | XP105DR, XP205, XP205DR, XP204, XP504, XP504DR |
| Maximum Capacity | 31 g / 120 g to 101 g / 520 g |
| Readability | 0.01 mg to 1 mg |
| Repeatability (sd) | 0.015 mg – 0.6 mg |
| Linearity Error | 0.1 mg – 0.5 mg |
| Eccentricity Error | 0.2 mg – 0.5 mg |
| Sensitivity Drift | 2 × 10⁻⁶ to 4 × 10⁻⁶ × Rnt |
| Temperature Coefficient of Sensitivity | 1 × 10⁻⁶ /°C × Rnt |
| Stability | 1 × 10⁻⁶ /a × Rnt |
| Typical Stabilization Time | 1.5 s – 2.5 s |
| Six Preloaded Applications | Weighing, Counting, Percentage, Density, Statistics, Formulation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX205DU/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 82 g / 220 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability (typ.) | 0.0125 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 25 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2.5 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT technology) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Certified Readability | 1 mg |
| Compliance | GxP, USP <41>, ISO/IEC 17025, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPE Micro Analytical Balance |
| Maximum Capacity | 100 g |
| Readability | 0.001 mg (1 µg) |
| Minimum Weight (USP <41>) | 1.4 mg (typical) |
| Repeatability | ≤ ±0.001 g (≤ ±1 mg) |
| Internal Calibration | Automatic, motorized |
| Weighing Pan | SmartGrid™ grid design with ErgoClip™ sample handling accessories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | ME54 / ME104 / ME204 / ME54E / ME104E / ME204E |
| Maximum Capacity | 52 g / 120 g / 220 g |
| Readability | 0.1 mg |
| Repeatability | ≤ ±0.1 mg |
| Linearity Error | 0.2 mg |
| Stabilization Time | 2 s |
| Sensitivity Drift | 2.0 ppm/°C |
| Pan Diameter | Ø 90 mm |
| Net Weight | 4.7 kg (ME) / 4.5 kg (ME E) |
| Calibration | Internal (ME series) or External (ME E series) |
| Compliance | ISO/IEC 17025, GLP, GMP, USP <41>, ASTM E898 |
| Power Consumption | Reduced by up to 50% vs. prior generation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | ML54, ML104, ML204, ML203, ML802, ML6001, ML303E |
| Max Capacity | 52 mg to 6200 g |
| Readability | 0.1 mg to 0.1 g |
| Repeatability | 0.1 mg to 0.001 g |
| Linearity Error | 0.2 mg to 0.002 g |
| Pan Dimensions | Ø90 mm to 170×190 mm |
| Calibration | Internal or External |
| Connectivity | RS232 & USB |
| Power | AC adapter or rechargeable battery |
| Applications | Formulation, piece counting, density determination, statistical analysis, dynamic weighing, checkweighing, percentage weighing, and data retrieval |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX303N/A |
| Instrument Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 1 mg |
| Minimum Weight (U=1%, k=2) | 100 mg |
| Minimum Weight (USP <41>, 0.1% tolerance) | 1 g |
| Repeatability (typ.) | 0.5 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT) |
| Pan Dimensions (W×D) | 127 mm × 127 mm |
| Display | 7-inch color TFT touchscreen |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Protection Class | IP41 |
| Verification Scale Interval (d) | 0.01 g |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | XSR105/AC |
| Type | Analytical Balance |
| Max Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability (typ.) | 0.008 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 16 mg |
| Stabilization Time | 3 s |
| Calibration | Internal, Fully Automatic (FACT) |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| Linearity Error (typ.) | ±0.2 mg |
| Dimensions (H × W × D) | 292 mm × 195 mm × 482 mm |
| Interface Options | USB-B, RS232 (integrated/optional), USB-A, Bluetooth (optional), Ethernet (LAN) |
| Compliance | 21 CFR Part 11–ready, GLP/GMP-supportive documentation, password-protected user management, audit trail logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX303/A |
| Instrument Type | Precision Balance |
| Maximum Capacity | 320 g |
| Readability | 1 mg |
| Minimum Weight (U=1%, k=2) | 100 mg |
| Minimum Weight (USP <41>, 0.1% tolerance) | 1 g |
| Repeatability (typ.) | 0.5 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT) |
| Pan Dimensions (W×D) | 127 mm × 127 mm |
| Display | 7-inch color TFT touchscreen |
| Interfaces | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Protection Class | IP41 |
| Legal-for-Trade Compliance | Yes |
| Software Compliance | GxP-ready with audit trail, user management, and electronic records |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX105/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability (typ.) | 0.0125 mg |
| Minimum Weight (U=1%, k=2, typ.) | 2.5 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Connectivity | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Compliance | GxP, USP <41>, <1251>, ISO/IEC 17025, FDA 21 CFR Part 11 (with appropriate software configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | MX104/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (typical) | 0.05 mg |
| Minimum Weight (U=1%, k=2, typical) | 10 mg |
| Stabilization Time | 2 s |
| Calibration | Internal (fully automatic FACT) |
| Display | 7-inch color TFT touchscreen |
| Pan Diameter | 90 mm |
| Dimensions (H×W×D) | 353 mm × 222 mm × 379 mm |
| Protection Class | IP41 |
| Certified Readability | 1 mg |
| Connectivity | USB-A, USB-C, Ethernet (LAN), Bluetooth (optional) |
| Compliance | GxP, USP <41>, <1251>, ISO/IEC 17025, FDA 21 CFR Part 11 (with LabX software) |