Beifen Sanpu
Filter
Showing 181–210 of 450 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cryo-Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-34340 |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Second-Stage Heating Rate | >3000 °C/min |
| Peak Width | <3 s |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Valve Max Temp | 240 °C |
| Tube Compatibility | OD ≤6.5 mm, L ≥150 mm |
| Power Consumption | 500 W |
| Dimensions (L×W×H) | 380×220×410 mm |
| Weight | ~15 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption (Cold Trap Flash) Temperature Range | 100–400 °C |
| Valve Oven Temperature Range | Ambient to 200 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Cold Trap Temperature Range | Down to −35 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Analyte Recovery Rate | >90% |
| Sample Capacity | 20 Adsorption Tubes |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ATDS-3430 |
| Instrument Type | Dual-stage thermal desorber (cold trap enabled) |
| Automation Level | Semi-automatic |
| Desorption Temperature Range | Ambient to 450 °C |
| Valve Injection Zone Temperature Range | Ambient to 200 °C |
| Transfer Line Temperature Range | Ambient to 200 °C |
| Cold Trap Temperature Range | Down to –35 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Analyte Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage (Cold Trap) Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 1 tube per run |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Application | Compliance with GB 50325-2020 for Indoor Environmental VOC Monitoring |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cryo-Focusing Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Dimensions | 380 × 220 × 410 mm |
| Weight | ~15 kg |
| Power Consumption | 500 W |
| Temperature Control Accuracy | < ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Second-Stage Heating Rate | >3000 °C/min |
| Peak Width | <3 s |
| Sample Tube Compatibility | OD ≤6.5 mm, L ≥150 mm |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-3430 |
| Instrument Type | Dual-stage thermal desorber, cryogenic trap thermal desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 1 tube per run |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-40A |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 450 °C (1 °C increments) |
| Valve Injection Zone Temperature Range | Ambient to 300 °C (1 °C increments) |
| Transfer Line Temperature Range | Ambient to 300 °C (1 °C increments, 24 V low-voltage heating) |
| Secondary Desorption Temperature Range | Ambient to 450 °C (1 °C increments) |
| Cryo-Focusing Trap Temperature Range | −35 °C to Ambient (1 °C increments |
| Temperature Control Accuracy | < ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 40 positions |
| Sample Tube Specification | 1/4″ OD × 3.5″ length (ASTM D6196-compliant) |
| Carryover Mitigation | Automated back-flush of valve and transfer line (0–100 mL/min, continuously adjustable) |
| Quantitative Reproducibility | RSD ≤2.5% (benzene at 0.05 μg in methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Simulated Sampling Flow | 0–160 mL/min (continuously adjustable) |
| Dimensions | 350 × 450 × 550 mm (W × D × H) |
| Weight | ~45 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beifen Sanpu Instruments Co., Ltd. |
| Model | ATDsS-20A |
| Instrument Type | Dual-stage thermal desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryo-Trap Temp Range | −35 °C to ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Temperature Control Precision | < ±0.5 °C |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorption Unit |
| Model | ATSD-20A |
| Sample Capacity | 20 positions |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Heating Ramp Rate (2nd Stage) | >3000 °C/min |
| Peak Width (2nd Stage) | <3 s |
| Valve Type | High-Temperature 6-Port Rotary Valve (up to 240 °C) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryotrap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Solid-State Electronic Refrigeration |
| Temperature Control Precision | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Valve Actuation | Motor-Driven 6-Port Rotary Valve |
| GC Interface | Universal low-diffusion interface compatible with Agilent, Thermo, Shimadzu, and PerkinElmer GC/GC-MS systems] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | 50–380 °C |
| Secondary Desorption Temp Range | 150–380 °C |
| Valve & Transfer Line Temp Range | Ambient to 200 °C |
| Cryo-Focusing Trap Temp | −30 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | > 80% |
| Sample Position Capacity | 1 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Sample Capacity | 10 or 20 positions |
| Heating Block Temperature Range | Ambient to 380 °C |
| Transfer Line Temperature Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Timing Range | 1 s to 99 min 59 s |
| Timing Accuracy | <0.1% |
| Power Supply | 220 VAC, 50 Hz |
| Max Power Consumption | <400 VA |
| Optional Configurations | Ambient-Temperature or Cryogenic Secondary Trapping |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AutoTDS-III |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | 50–380 °C |
| Cold Trap Temp Range | −30 °C (electronic Peltier cooling) |
| Secondary Desorption Temp Range | 150–380 °C |
| Secondary Desorption Ramp Rate | >1800 °C/min |
| Valve & Transfer Line Temp Range | Room Temp to 200 °C |
| Temperature Control Accuracy | <±0.1 °C |
| Desorption Recovery Rate | ≥90% |
| Sample Position Capacity | 1 |
| Brand | Beifen Sanpu |
|---|---|
| Model | AutoTDS-III |
| Instrument Type | Dual-stage thermal desorber |
| Desorption Temperature Range (1st stage) | 50–380 °C |
| Cold Trap Temperature Range | −30 °C |
| Desorption Temperature Range (2nd stage) | 150–380 °C |
| Heating Rate (2nd stage) | >1800 °C/min |
| Transfer Line Temperature Range | 50–200 °C |
| Power Consumption | <800 VA |
| Sample Capacity | 1 tube |
| Desorption Recovery Rate | ≥90% |
| Simulated Sampling Flow Rate | 0–1000 mL/min (adjustable) |
| Cooling Method | Peltier-based electronic cold trap |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | AvHS-20A PLUS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AwTDS-20A |
| Temperature Control Range (Desorption 1) | Ambient to 450 °C (1 °C increments) |
| Valve & Transfer Line Temp Range | Ambient to 300 °C (1 °C increments) |
| Cryogenic Trap Temp Range | −35 °C to Ambient (1 °C increments, electronic cooling) |
| Temperature Accuracy | < ±0.5 °C |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Sample Capacity | 20 positions |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Re-injection & Backflush Flow | 0–100 mL/min (adjustable) |
| Simulated Sampling Flow | 0–160 mL/min (adjustable) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Heating Rate (2nd Stage) | >3000 °C/min |
| Dimensions | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve & Transfer Line Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Wash Time | 0–30 min |
| RSD | <1.0% (at 100 ppm ethanol in water) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL, 100 mL) |
| Sample Heating Range | 40–220 °C (optional up to 300 °C) |
| Valve & Transfer Line Heating Range | 40–220 °C (optional up to 300 °C) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | < ±0.5 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out/Flush Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Quantitative Loop Volume | 1 mL (optional: 0.5, 2, 5 mL) |
| RSD | < 1.0% (for 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Interface | USB |
| Inert Flow Path | Deactivated fused-silica and PEEK tubing throughout |
| Valve Configuration | High-precision 6-port rotary valve with integrated heated zone |
| Sampling Mode | Single-shot, multi-shot per vial, or sequential multi-vial |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BF-1000N |
| Power Consumption | 200 W |
| Nitrogen Purity | 99.996% (v/v, O₂-equivalent) |
| Output Flow Rate | 0–1000 mL/min |
| Output Pressure | 0.4 MPa |
| Input Air Pressure | 0.5 MPa |
| Operating Temperature | 10–40 °C |
| Relative Humidity | <85% RH |
| Dimensions (L×W×H) | 520×280×400 mm |
| Weight | ~25 kg |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments, compatible with GLP/GMP workflows requiring documented gas supply integrity |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BF-2L |
| Price Range | USD 1,400 – 7,000 (est.) |
| Hydrocarbon Removal Principle | Catalytic Cracking |
| Output Flow Rate | 0–300 mL/min |
| Output Pressure | 100 psi (6.9 bar) |
| Total Hydrocarbon Content | ≤0.1 ppm (as methane equivalent) |
| Dew Point | −10 °C |
| Noise Level | ≤42 dB(A) |
| Input Voltage | AC 220 V, 50 Hz |
| Rated Power | 150 W |
| Weight | 23 kg |
| Dimensions (L×W×H) | 490 × 240 × 380 mm |
| Operating Ambient Temperature | 15–40 °C |
| Relative Humidity | <70% RH (non-condensing) |
| Air Purity Grade | Oil-free, Triple-stage Purified Air |
| Brand | Beifen Sanpu |
|---|---|
| Model | BF-5 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Output Flow | 0–5 L/min (0–5000 mL/min) |
| Output Pressure | 0.4 MPa (standard for GC air supply) / 0.5 MPa (for air input to nitrogen generators) |
| Hydrocarbon Content | <0.1 ppm (HC) |
| Dew Point | –60 °C |
| Filtration Stages | Triple-stage purification (particulate, coalescing, catalytic hydrocarbon removal) |
| Pressure Regulation | Dual-stage precision pressure regulation |
| Safety Features | Over-pressure protection, automatic condensate drain valve |
| Noise Level | ≤42 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 180 W |
| Weight | 24 kg |
| Dimensions (L×W×H) | 490 × 240 × 380 mm |
| Operating Temperature | 15–40 °C |
| Relative Humidity | <70% RH |
| Ambient Requirements | Low-dust, non-corrosive environment |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BF-500 |
| Hydrogen Purity | 99.999% (O₂ < 1 ppm) |
| Hydrogen Flow Range | 0–500 mL/min |
| Hydrogen Working Pressure | 0.4 MPa (adjustable, factory-set) |
| Air Flow Range | 0–5 L/min |
| Air Pressure | 0.4 MPa |
| Air Filtration | Oil-free, 3-stage purification (particulate, hydrocarbon, moisture) |
| Output Stability | ≤ ±0.01 MPa |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 280 W |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions (L×W×H) | 520 × 280 × 400 mm |
| Net Weight | 42 kg |
| Electrolyte | KOH aqueous solution (160 g in 400 mL distilled water, total reservoir volume 1.6 L) |
| Water Refill Requirement | Distilled water only |
| Safety Features | Non-return liquid trap, over-pressure cutoff, electrolyte level sensor, thermal protection, auto-shutdown on leak or dry-run |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BFS-9860 |
| Pricing | Upon Request |
| Detection Gases | H₂ (0–2000 µL/L, LOD 2 µL/L, RSD ≤10%), CO (0–5000 µL/L, LOD 25 µL/L, RSD ≤10%), CH₄ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₄ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₆ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₂ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), H₂O (optional, 2–100% RH, LOD 2% RH, RSD ≤10%), CO₂ (optional, 0–15000 µL/L, LOD 25 µL/L, RSD ≤10%) |
| Analysis Cycle | ≥1 hour (user-configurable) |
| Data Retention | 10 years |
| Temperature Control Accuracy | ±0.1°C |
| Operating Ambient | −40°C to +70°C, 5–95% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz, THD <5% |
| Carrier Gas | High-purity compressed air (≥400 analyses per cylinder) |
| Mechanical Robustness | Compliant with GB/T 14537 (Shock, Class I) and GB/T 11287 (Vibration, Class I) |
| EMC Compliance | GB/T 17626, IEC 61000, Q/GDW 535–2010 |
| Communication Interfaces | RS-485, Ethernet, Fiber Optic, CAN bus, GPRS/CDMA |
| Network Scalability | Up to 16 field units per central server |
| Alarm Output | Dual-level (audible/visual), remote signal transmission |
| Software Platform | SQL Server 2000, role-based access control, IEC 61850 support, TCP/IP native |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | BFSPGC-9860 |
| Dimensions (L×H×W) | 520 × 480 × 500 mm |
| Column Oven Size | 260 × 250 × 150 mm |
| Column Installation Span | 152.4 mm (6-inch standard interface) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| Oven Temperature Range | +5 °C to 400 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Gradient | ±1% (100–350 °C) |
| Ramp Rate | 0.1–50 °C/min (0.1 °C increment) |
| Max Programmed Time | 6000 min |
| Programmable Steps | 8 |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| FID Linear Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (⁶³Ni source) |
| FPD Detection Limit (P/S) | ≤1×10⁻¹² g/s |
| NPD Detection Limit (N/P) | ≤5×10⁻¹³ g/s |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | BFTDS-III |
| Pricing | Upon Request |
| [Brand | Beifen Sanpu |
|---|---|
| Model | BFTDS-III |
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Benchtop Laboratory Thermal Desorption System |
| Heating Zones | Dual independent temperature-controlled zones (desorption furnace + syringe heater) |
| Desorption Temp Range | Ambient to 400 °C (1 °C increment, stability < ±0.5 °C) |
| Syringe Heater Temp Range | Ambient to 100 °C (1 °C increment, stability < ±0.5 °C) |
| Compatible Tube OD | 6 mm or 1/4″ |
| Carrier Gas Flow Control | 10–200 mL/min, stability < 0.1% |
| Syringe Capacity | Up to 100 mL gas-tight glass syringe |
| Desorption Recovery | >85% (compound-dependent) |
| Dimensions (H×W×D) | 390 × 170 × 360 mm |
| Power Consumption | ~500 W |
| Net Weight | ~9 kg |
| Compliance | Designed per GBZ/T 300.62–2017, GB 50325–2006, and ISO 16000-6 for VOC analysis] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BFYZ-15L |
| Nitrogen Generation Principle | Integrated durable synthetic carbon molecular sieve (CMS) for deep nitrogen purification |
| Output Flow Rate | 0–15 L/min |
| Output Pressure | 0–100 psi (≈0.69 MPa) |
| Nitrogen Purity | ≥99.9% |
| Dew Point | ≤−40 °C |