Beifen Sanpu
Filter
Showing 151–180 of 450 results
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cold Trap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Temperature Control Precision | ±0.5 °C |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | ATDS-20A |
| Pricing | Upon Request |
| Sample Capacity | 20 positions |
| Cold Trap Temperature Range | −35 °C to ambient |
| Primary Desorption Temp | RT–450 °C |
| Secondary Desorption Temp | RT–450 °C |
| Valve & Transfer Line Temp | RT–300 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene in 0.05 μg methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Sampling Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Carrier Gas Flow (Purge/Backflush) | 0–100 mL/min |
| Simulated Sampling Flow | 0–160 mL/min |
| Heating Ramp Rate (2nd Stage) | >3000 °C/min |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-20A |
| Price | USD 21,800 (FOB Beijing) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cryo-Focusing Trap Temperature Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 adsorption tubes |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Sample Capacity | 20 positions |
| Primary Heating Zone Temp Range | Ambient to 450 °C (1 °C increments) |
| Secondary Desorption Zone Temp Range | Ambient to 450 °C (1 °C increments) |
| Cryogenic Trap Temp Range | −35 °C to ambient (electronic cooling) |
| Temperature Accuracy | ±0.5 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Relative Standard Deviation (RSD) | ≤2.5% (benzene at 0.05 μg) |
| Transfer Line & Valve Temp Control | Ambient to 300 °C |
| Re-focusing Time | 0–60 min |
| Injection Time | 0–60 min |
| Purge/Backflush Flow | 0–100 mL/min (adjustable) |
| Simulated Sampling Flow | 0–160 mL/min |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Interface | Motor-driven 6-port valve |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryogenic Trap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Electronic Peltier |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene on Tenax TA tube) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Valve Actuation | Motor-driven 6-port switching valve |
| GC Interface | Universal GC inlet compatibility (split/splitless, PTV, etc.) |
| Dimensions | 350 × 450 × 510 mm (W×D×H) |
| Weight | ~40 kg] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ATDS-20A |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 positions |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | ATDS-20A |
| Instrument Type | Dual-Stage Thermal Desorber, Thermal Desorption Unit |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryotrap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cooling Method | Electronic refrigeration |
| Temperature Control Precision | ±0.5 °C |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Valve Actuation | Motor-driven 6-port switching valve |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| GC Interface | Universal low-diffusion interface compatible with all major GC/GC-MS systems |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% |
| Sample Positions | 20 |
| Temperature Control Precision | < ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Repeatability | High reproducibility across sequential runs |
| Compliance | Designed for ASTM D6196, ISO 16017-1, US EPA TO-17, HJ 644–2013, HJ 583–2010, HJ 734–2014, GB/T 18883–2002, GB 50325–2010 |
| Brand | Beifen Sanpu |
|---|---|
| Model | ATDS-20A |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to −35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 adsorption tubes |
| Origin | Hebei, China |
| Manufacturer | Beifen Sanpu Instruments Co., Ltd. |
| Compliance | HJ 734–2014, HJ 644–2013 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | ATDS-20A |
| Instrument Type | Two-stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 450 °C |
| Secondary Desorption Temperature Range | 100–450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Electronic Refrigeration |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Specification | 1/4″ OD × 3.5″ length (ASTM D6196-compliant) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 450 °C |
| Secondary Desorption (Flash) Temperature Range | 100–450 °C |
| Cryo-Focusing Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Electronic Peltier Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Specification | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Valve Actuation | Motor-driven 6-port switching valve |
| GC Synchronization | TTL-level trigger output for GC start and data system |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-20A |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryo-Focusing Trap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Cold Trap Cooling Method | Electronic Peltier |
| Sample Tube Standard | 1/4″ OD × 3.5″ (ASTM D6196-compliant)] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Sample Capacity | 20 positions |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −40 °C to +40 °C |
| Desorption Recovery Rate | ≥95% (for target VOCs per ISO 16000-6 & HJ 644-2013) |
| Control System | Microprocessor-based with programmable multi-step thermal protocol |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryo-Trap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (benzene at 0.05 μg) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Valve Actuation | Motor-driven 6-port switching valve |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ATDS-20B |
| Instrument Type | Secondary Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% |
| Sample Capacity | 40 tubes (dual 20-position carousel) |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Thermal Desorption System |
| Model | ATDS-20B |
| Sample Capacity | Dual 20-position (40 total) |
| Sample Tube Specification | 1/4″ × 3.5″ (ASTM D6196-compliant) |
| Injection Mode | Motor-driven 6-port valve |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption (Cold Trap) Temp Range | –35 °C to ambient (Peltier-cooled) |
| Transfer Line Temp Range | Ambient to 300 °C |
| Valve & Interface Temp Range | Ambient to 300 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Heating Rate (2nd Stage) | >3000 °C/min |
| Simulated Sampling Flow | 0–160 mL/min (adjustable) |
| Purge/Backflush Flow | 0–100 mL/min (adjustable) |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg in methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Dimensions | 350 × 450 × 550 mm |
| Weight | ~40 kg] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ATDS-20B |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorber |
| Primary Desorption Temperature Range | 100–450 °C |
| Secondary Desorption (Focusing) Temperature Range | Room Temp–450 °C |
| Cryo-Focusing Trap Temperature Range | –35 °C to Room Temp |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 40 positions (dual 20-position carousel) |
| Carrier Gas Flow Control | 0–100 mL/min (purge/flush), 0–160 mL/min (calibration/sampling simulation) |
| Temperature Accuracy | < ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Heating Ramp Rate | >3000 °C/min (secondary desorption zone) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Interface | Motor-driven 6-port valve, GC-compatible universal inlet adapter |
| Dimensions | 350 × 450 × 550 mm (W × D × H) |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 450 °C (1 °C increments) |
| Valve Injection Zone Temperature Range | Ambient to 300 °C (1 °C increments) |
| Transfer Line Temperature Range | Ambient to 300 °C (1 °C increments) |
| Cryo-Focusing Trap Temperature Range | −35 °C to ambient (1 °C increments) |
| Temperature Control Accuracy | < ±0.5 °C |
| Analyte Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 24 positions |
| Cooling Rate | ≤ −35 °C with rapid thermal stabilization |
| Secondary Desorption Ramp Rate | >3000 °C/min |
| Carryover Reduction | Integrated valve and transfer line back-flush (0–100 mL/min, adjustable) |
| Calibration & Activation | Onboard tube activation protocol and simulated sampling flow control (0–160 mL/min) |
| Precision | RSD ≤ 2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Format | 1/4″ OD × 3.5″ length (ASTM D6196-compliant stainless steel or quartz-lined tubes) |
| Interface | Motor-driven 6-port switching valve |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Two-stage thermal desorber / Thermal desorption unit |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | Ambient to 450 °C (1 °C increments) |
| Valve Injection Zone Temperature Range | Ambient to 300 °C (1 °C increments) |
| Transfer Line Temperature Range | Ambient to 300 °C (1 °C increments) |
| Cryo-Focusing Trap Temperature Range | −35 °C to ambient (1 °C increments) |
| Temperature Control Accuracy | < ±0.5 °C |
| Analyte Recovery Rate | > 99% (compound-dependent) |
| Sample Capacity | Dual 24-position trays (48 total samples) |
| Dimensions | 350 × 450 × 550 mm (W × D × H) |
| Weight | ~40 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ATDS-342 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | 30–400 °C |
| Cold Trap Temperature Range | −30 °C |
| Desorption Recovery Rate | >85% |
| Sample Capacity | 20 positions |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ATDS-3420 |
| Pricing | Upon Request |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to –35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 adsorption tubes |
| Dimensions | 360 × 170 × 390 mm |
| Weight | ~10 kg |
| Temperature Control Accuracy | < ±0.5 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Single-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption / Focusing Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to –35 °C |
| Desorption Recovery Rate | >90% (compound-dependent) |
| Sample Capacity | 20 adsorbent tubes |
| Dimensions | 360 × 170 × 390 mm |
| Weight | ~10 kg |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | ATDS-3420 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 400 °C |
| Secondary Desorption Temperature Range | 100–400 °C |
| Cold Trap Temperature Range | Down to –35 °C |
| Desorption Recovery Rate | >90% |
| Sample Capacity | 20 adsorption tubes |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | ATDS-3420HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3430 |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |
| Cooling Method | Semiconductor-based Peltier cooling |
| Peak Width | <3 s |
| Second-Stage Heating Rate | >3000 °C/min |
| Valve Type | High-Temperature 6-Port Switching Valve (up to 240 °C) |
| Interface Compatibility | Universal GC/GC-MS inlet coupling (including Agilent, Thermo, Shimadzu, PerkinElmer) |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-3430 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Primary Desorption Temperature Range | Ambient to 450 °C |
| Cryo-Trap Temperature Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Capacity | 1 tube |