DAZHAN
Filter
Showing 31–59 of 59 results
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–30 g |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas channel with mass flow control (inert, oxidizing, reducing, static, dynamic) |
| Display | 7-inch LCD touchscreen |
| Data Interface | USB |
| Software | Integrated TGA analysis suite with TG/DTG curve fitting, multi-point temperature calibration, Excel/PDF export, and GLP-compliant reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3500S |
| Display | 7-inch capacitive touchscreen |
| Quartz tube dimensions | φ44 × 600 ± 5 mm |
| Furnace chamber | Φ45 × 300 ± 5 mm |
| Heating element | high-temperature alloy wire |
| Heating zone length | 350 mm |
| Operating temperature range | ambient to 1200 °C |
| Temperature control | intelligent programmable multi-segment PID |
| Temperature resolution | 0.1 °C |
| Power supply | AC 220 V / 50 Hz or 60 Hz |
| Gas flow control | dual-channel, program-automated switching |
| Cooling method | forced-air + lid-open rapid cooling (≤20 min from 900 °C to ambient) |
| Sample capacity | 4 positions per run |
| Data processing | built-in calculation engine for carbon black % and ash % |
| Optional accessories | exhaust filtration unit, thermal printer |
| Brand | DAZHAN |
|---|---|
| Model | DZ3500S |
| Origin | Jiangsu, China |
| Heating Range | Ambient to 1200 °C |
| Temperature Uniformity | ±5 °C across 350 mm heating zone |
| Control System | Intelligent programmable controller with multi-segment ramp/soak profiles |
| Sample Capacity | 4 positions simultaneously |
| Cooling Time | ≤20 min (900 °C → ambient) via lid-open forced cooling |
| Furnace Tube | Quartz, φ44 × 600 ±5 mm |
| Chamber Dimensions | φ45 × 300 ±5 mm |
| Heating Element | High-temperature alloy wire |
| Temperature Resolution | 0.1 °C |
| Gas Control | Dual-channel automated switching between N₂ and O₂ |
| Display | 7-inch capacitive touchscreen |
| Data Output | Built-in calculation engine for carbon black % and ash % |
| Compliance | Designed to support ASTM D1602, ISO 6964, and GB/T 3512-compliant workflows |
| Safety Features | Lid-open interlock, over-temperature alarm, real-time gas flow monitoring |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3500S |
| Heating Range | Ambient to 1200 °C |
| Sample Capacity | 4 positions |
| Temperature Control | Programmable multi-segment PID control |
| Cooling Time | ≤20 min (900 °C to ambient) |
| Display | 7-inch capacitive touchscreen |
| Quartz Tube Dimensions | φ44 × 600 ± 5 mm |
| Furnace Chamber Diameter | φ45 × 360 ± 5 mm |
| Heating Element | High-temperature alloy wire |
| Heating Zone Length | 350 mm |
| Temperature Sensor Resolution | 0.1 °C |
| Gas Flow Control | Dual-channel automated switching |
| Safety Features | Lid-open thermal warning, over-temperature cutoff |
| Optional Accessories | Exhaust filtration unit, thermal printer |
| Compliance Standards | GB/T 13021–1991, GB/T 13663.2–2018, GB/T 3515–2005, IEC 60881-4-1:2004, ASTM D1603–2012, GB/T 2951.41–2008 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3500S |
| Display | 7-inch capacitive touchscreen |
| Quartz tube dimensions | Φ44 × 600 ± 5 mm |
| Furnace chamber dimensions | Φ45 × 300 ± 5 mm |
| Heating element | high-temperature alloy wire |
| Heating zone length | 350 mm |
| Operating temperature range | ambient to 1200 °C |
| Temperature control | intelligent programmable controller with multi-segment ramp/soak profiles |
| Temperature resolution | 0.1 °C |
| Power supply | AC 220 V / 50–60 Hz |
| Gas flow control | dual-channel, program-automated switching |
| Cooling time | ≤20 min (from 900 °C to ambient), enabled by hinged lid design |
| Sample capacity | 4 positions per run |
| Sample handling | rail-mounted sample holder with lid-open access |
| Data processing | embedded software for automatic calculation of carbon black content and ash content |
| Optional accessories | exhaust filtration unit, thermal printer |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit) |
| Q Accuracy | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution) |
| Capacitance Range | 1 pF – 25 nF (0.1 pF resolution) |
| Main Tuning Capacitor | 17–240 pF (silver-plated, ±1 pF or <1% error) |
| Signal Source Stability | 3×10⁻⁵ ±1 digit |
| ADC Resolution | 12-bit |
| Auto-Null Compensation | Residual inductance & lead inductance |
| Display | LCD with real-time F, L, C, Q, Lₜ, Cₜ, εᵣ, tan δ |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-Factor Based) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Capacitance Range (Tuning) | 17–240 pF |
| Capacitance Direct Measurement | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| AD Sampling | 12-bit |
| Automatic Residual Inductance Compensation | Yes |
| Motorized Capacitor Tuning | Yes |
| Display | LCD with Real-Time Parameters (F, L, C, Q, Lt, Ct, εᵣ, Tn) |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Parallel-Plate Capacitor Configuration) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Residual & Lead Inductance Compensation | Yes |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, tanδ, Tn |
| Compliance | GB/T 1693–2007, ASTM D150, GB 9622.9–1988 / SJ/T 11043–1996 |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Tuning Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Auto Capacitance Search | Yes (stepper motor driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Residual Inductance Compensation | Yes |
| Data Interface | RS-232/USB for PC connectivity |
| Compliance | Designed per IEC 60250 and ASTM D150 guidelines for dielectric property measurement |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Residual Inductance Compensation | Yes |
| Auto-Resonance Search | Yes (stepper motor–driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Compliance | Designed for ASTM D150, IEC 60250, GB/T 1409, and ISO 18732-compliant dielectric characterization workflows |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | −30 °C to 200 °C |
| Accuracy | ±0.00001 W/(m·K) |
| Repeatability | ≤1% |
| Measurement Time | ≤160 s |
| Sample Forms | Solid, liquid, powder, paste, gel, thin film, and insulating materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Power Consumption | <300 W |
| Sample Dimensions (Solid) | ≥15 mm × 15 mm × 7.5 mm (Probe #1), ≥30 mm × 30 mm × 15 mm (Probe #2) |
| Liquid/Powder Capacity | 18 mL via dedicated fixture |
| Operating Environment | Ambient temperature, air atmosphere |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Temperature Range | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Sample Forms | Solid, Liquid, Powder, Paste, Gel, Coating, Thin Film |
| Probe Diameters | 7.5 mm, 15 mm, 50 mm (interchangeable) |
| Measurement Time | 5–160 s (user-configurable) |
| Repeatability | ≤3% |
| Power Supply | AC 220 V, <500 W |
| Sample Dimensions (min.) | 15×15×3.75 mm (for 7.5 mm probe) |
| Compliance | ASTM D5334, ISO 22007-2, GB/T 32064–2015 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (extendable to −40 °C to 300 °C) |
| Sample Forms | Solid, Liquid, Gel, Paste, Powder, Film, Granular, Metallic, Insulating Materials |
| Probe Options | 7.5 mm, 15 mm, 50 mm diameter dual-spiral probes |
| Measurement Time | 5–160 s (user-configurable) |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V |
| Max. Power Consumption | <500 W |
| Probe Power Limits | ≤1 W (Φ7.5 mm), ≤20 W (Φ15 mm), ≤22 W (Φ50 mm) |
| Minimum Sample Dimensions | ≥15×15×3.75 mm (Φ7.5 mm probe), ≥30×30×7.5 mm (Φ15 mm probe), ≥50×50×15 mm (Φ50 mm probe) |
| Optional Accessories | Custom powder test cell |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (extendable to 300 °C) |
| Sample Forms | Solid, Liquid, Gel, Paste, Powder |
| Probe Options | 7.5 mm, 15 mm, 50 mm diameter planar sensors |
| Measurement Time | 5–160 s |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V, <500 W |
| Sample Size Requirements | ≥15×15×3.75 mm (for 7.5 mm probe), ≥30×30×7.5 mm (for 15 mm probe), ≥50×50×15 mm (for 50 mm probe) |
| Compliance | ASTM D5334, ISO 22007-2, GB/T 32064–2015 |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Sample Forms | Metals, Liquids, Solids, Powders, Pastes, Gels |
| Test Duration | 5–160 s |
| Operating Temperature | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Probe Diameters | 7.5 mm, 15 mm, 50 mm |
| Power Supply | AC 220 V, <500 W |
| Minimum Sample Dimensions (per probe) | 15×15×3.75 mm |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Dimensions (L×W×H) | 455 × 390 × 200 mm |
| Repeatability | ≤3% |
| Temperature Range | Room temperature to 130 °C (extendable to 300 °C with optional heating module) |
| Sample Forms | Solids (bulk, film, coating), powders, liquids, pastes, gels, and aerogels |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-S |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | Ambient to 130 °C (optional extension: −40 °C to 300 °C) |
| Sample Forms | Solids (bulk, granular, coated, thin-film), Liquids, Gels, Pastes, Powders |
| Test Duration | 5–160 s per measurement |
| Probe Options | 7.5 mm, 15 mm, and 50 mm diameter probes |
| Dimensions (L×W×H) | 440 × 390 × 220 mm |
| Power Supply | AC 220 V, <500 W |
| Max. Probe Power | 1 W (7.5 mm), 20 W (15 mm), 22 W (50 mm) |
| Sample Size Requirements | ≥15×15×3.75 mm (7.5 mm probe), ≥30×30×7.5 mm (15 mm probe), ≥50×50×15 mm (50 mm probe) |
| Software | Integrated TPS data acquisition & thermal property calculation module with real-time curve fitting and ASTM/ISO-compliant reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Dimensions (L×W×H) | 455 × 390 × 200 mm |
| Repeatability | ≤3% |
| Temperature Range | Room temperature to 130 °C (extendable to –40 °C to 300 °C with optional modules) |
| Sample Forms | Solids (bulk, film, powder, paste, gel), Liquids, Coatings, Insulating materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC300 |
| Sample Capacity | Single-sample |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Isothermal Hold Duration | Up to 24 h |
| Atmosphere Control | Dual-gas automatic switching (N₂, Air, Ar, or custom), 0–200 mL/min flow, ≤0.5 MPa pressure |
| Control Mode | Fully programmable 6-segment heating/holding/cooling sequences with PID regulation |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB |
| Calibration Standards Included | Indium, Tin, Lead |
| Software Features | Multi-point temperature calibration, real-time baseline correction, GLP-compliant data logging |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Sample Capacity | Single |
| Instrument Type | DSC |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling (Fully Automated) |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (Expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Gas Control | Dual-channel Automatic Switching (N₂, Air, or Custom Gases), Flow Rate 0–200 mL/min, Max Pressure 0.5 MPa |
| Thermal Calibration Standards Included | Indium, Tin, Lead |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit TFT LCD Touchscreen |
| Power Supply | AC 220 V / 50 Hz (Optional Custom Voltage) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA200 |
| Coupling Technique | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Sensitivity | 0.01 mg |
| DSC Range | ±800 mW |
| DSC Resolution | 0.001 mW |
| Display | 7-inch 24-bit Color Touchscreen |
| Communication Interface | USB 2.0 |
| Gas Control | Dual-channel Mass Flow Controller with Integrated Flow Meters |
| Calibration | Multi-point Temperature & Enthalpy Calibration |
| Software Compliance | Audit Trail, Data Export (CSV, Excel, PDF), GLP-Ready Reporting |
| Brand | DAZHAN |
|---|---|
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Dual-gas manifold with integrated mass flow meters and automated switching |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | Standard USB |
| Software | Integrated TGA analysis suite with TG/DTG curve processing, Excel/PDF export, multi-point temperature calibration, and audit-ready reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Sensitivity | 0.01 mg |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Programmable Stages | Up to 5 temperature segments |
| Isothermal Hold Duration | 0–300 min per segment (configurable up to 72 h total) |
| Display | 7-inch Chinese-language LCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.1 °C |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 600 min (standard), user-definable |
| Atmosphere Control | Triple-Gas Mass Flow Controller (MFC) System |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Intelligent PID with Self-Tuning & Hybrid Static/Dynamic Optimization |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ3500A |
| Price | USD 3,500 (FOB Jiangsu) |
| Display | Color TFT Touchscreen |
| Heating Element | High-Temperature Alloy Wire |
| Furnace Dimensions | Ø30 × 400 ±5 mm |
| Heating Zone Length | 200 mm |
| Isothermal Zone Length | 150 mm |
| Operating Temperature Range | Ambient to 990 °C |
| Temperature Control | Intelligent Programmable PID |
| Power Supply | AC 220 V / 50–60 Hz |
| Sensor Resolution | 0.1 °C |
| Gas Flow Control | Dual-Channel — 0–200 mL/min & 0–2 L/min |
| Atmosphere | N₂ → O₂ switchable purge sequence |
| Measurement Principle | Thermogravimetric Analysis (TGA) under controlled inert/oxidizing atmosphere |
| Brand | DAZHAN |
|---|---|
| Model | DZ3500S |
| Application | Carbon black dispersion & ash content determination in polyolefins, rubber, cable compounds, and polymer composites |
| Temperature Range | Ambient to 1200 °C |
| Heating Zone Length | 350 mm |
| Quartz Tube Dimensions | Ø44 × 600 ± 5 mm |
| Furnace Chamber Dimensions | Ø45 × 300 ± 5 mm |
| Sample Capacity | 4 positions (simultaneous analysis) |
| Cooling Time | ≤20 min (900 °C → ambient, with lid open) |
| Control Interface | 7-inch capacitive touchscreen |
| Temperature Control | Intelligent programmable multi-segment PID |
| Power Supply | AC 220 V / 50–60 Hz |
| Temperature Sensor Resolution | 0.1 °C |
| Gas Flow Control | Dual-channel automated switching |
| Optional | Exhaust filtration unit, thermal printer |
| Compliance | Designed per ASTM D1606, ISO 6964, GB/T 3512, and relevant portions of USP <467> residual carbon methodology |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3500S |
| Display | 7-inch capacitive touchscreen |
| Quartz tube dimensions | Φ44 × 600 ± 5 mm |
| Furnace chamber | Φ45 × 300 ± 5 mm |
| Heating zone length | 350 mm |
| Operating temperature range | Ambient to 1200 °C |
| Temperature control | Intelligent programmable multi-segment controller |
| Temperature resolution | 0.1 °C |
| Power supply | AC 220 V / 50 Hz or 60 Hz |
| Gas flow control | Dual-channel, program-automated switching |
| Cooling method | Forced open-lid rapid cooling (≤20 min from 900 °C to ambient) |
| Sample capacity | 4 positions per run |
| Data processing | Built-in calculation engine for carbon black content and ash content |
| Optional accessories | Exhaust filtration unit, thermal printer |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Principle | Transient Plane Source (TPS) Method |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.00001 W/(m·K) |
| Temperature Range | −30 °C to 200 °C |
| Sample Form Compatibility | Solids (bulk, metallic, powder, film), liquids, gels, pastes, and thermal insulation materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 3.75 mm (Probe #1) or 30 mm × 30 mm × 7.5 mm (Probe #2) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Duration | ≤160 s |
| Power Consumption | <300 W |
