| Model | DZ-DSC101 |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 800 °C |
| Temperature Accuracy | ±0.001 °C |
| Temperature Precision | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | ±800 mW |
| Temperature Control Method | Digital PID algorithm with programmable ramp-hold-cool profiles |
| Sensor Material | Constantan-based thermocouple array |
| Atmosphere Control | Dual-gas switching system with integrated flow regulation and auxiliary purge gas inlet |
| Cooling Method | Forced-air cooling |
| Compliance | Designed for GLP-compliant thermal analysis workflows |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300 |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Programmable Segments | Up to 6 heating/holding/cooling steps |
| Atmosphere Control | Dual-gas auto-switching (0–200 mL/min, ≤0.5 MPa) |
| Data Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), 0.1–40 K/min (cooling) |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| DSC Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (up to 200 mL/min, ≤0.5 MPa), plus dedicated purge gas inlet |
| Thermal Program | Up to 6-segment ramp/hold |
| Display | 7-inch 24-bit color LCD touchscreen |
| Interface | Standard USB with auto-reconnect capability |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1–20 °C/min (cooling, air-cooled variant) |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual mass-flow-controlled gas channels + auxiliary purge line |
| Cooling Options | Air cooling, Peltier, mechanical refrigeration, or liquid nitrogen (model-dependent) |
| Software | Integrated GLP-compliant data acquisition and analysis suite with audit trail capability |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Intelligent PID Algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), –0.1 to –20 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Cooling Options | Forced-air, Peltier, Mechanical Refrigeration, Liquid Nitrogen |
| Atmosphere Control | Dual independent mass-flow-controlled gas channels + dedicated purge gas inlet |
| Sensor Type | Corrosion-resistant, EMI-shielded thermocouple array |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −50 °C to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Temperature Precision (Resolution) | 0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Scan Modes | Isothermal, dynamic heating, dynamic cooling |
| DSC Signal Range | ±1000 mW |
| Temperature Stability (Drift) | ≤0.1 °C/h |
| Cooling Method | Peltier-based active refrigeration (standard) |
| Gas Control | Triple-gas manifold with automatic dual-atmosphere switching (e.g., N₂ ↔ O₂), plus dedicated inert purge line |
| Temperature Control Algorithm | Adaptive PID with self-tuning and dynamic/static hybrid compensation |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID with Self-Tuning & Adaptive Optimization |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.001 °C |
| Cooling Method | Integrated Thermoelectric (Peltier) Module |
| Gas Flow Control | Triple-channel Mass Flow System (0–200 mL/min per channel), Dual Atmosphere Switching with <3 s stabilization time, plus Dedicated Inert Purge Line |
| Temperature Resolution | 0.001 °C |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400D |
| Price Range | USD 19,500–27,800 (FOB China) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −70 °C to 600 °C |
| Temperature Control | Intelligent PID algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −60 °C/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Range | 0–200 mL/min (expandable) |
| Cooling Method | Integrated mechanical refrigeration system (supplemented by optional air-cooling, Peltier, and liquid nitrogen interfaces) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400L |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −80 K/min (cooling) |
| Scan Modes | Isothermal, Heating, Cooling |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min, expandable), plus dedicated purge/protect gas inlet |
| Cooling Method | Liquid nitrogen cryogenic cooling (supplemented by optional air-cooling, Peltier, or mechanical refrigeration modules) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Balance Sensitivity | 0.01 mg |
| DSC Range | 0 to ±800 mW |
| DSC Resolution | 0.001 mW |
| Atmosphere System | Dual-gas mass flow control with integrated flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Crucible Material | High-purity alumina ceramic |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price Range | USD 21,000–28,000 |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Maximum Sample Mass | 30 g (expandable to 50 g) |
| Mass Resolution | 0.01 mg |
| Mass Accuracy | ±1 mg |
| DSC Sensitivity | ±1000 mW |
| Atmosphere Control | Triple-gas mass flow control (digital MFCs) |
| Data Acquisition Interval | Real-time, 2 s, 5 s, or 10 s selectable |
| Cooling Time | ≤15 min (1000 °C → 50 °C) |
| External Water Cooling | Integrated chiller interface (−10 °C to 60 °C) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Sample Capacity | 30 g max |
| Mass Measurement Range | 0.01 mg–3 g (expandable to 50 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.01 µg |
| DSC Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Atmosphere Control | Integrated Digital Mass Flow Controller |
| Cooling Mode | Optional External Water Chiller (−10 to 60 °C) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA401 |
| Technique | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.01 °C |
| Mass Resolution | 1 µg |
| Mass Range | 0.01 mg–3 g (expandable to 50 g) |
| Maximum Sample Capacity | 30 g |
| Atmosphere Control | Inert, oxidative, reductive |
| Gas Flow Control | Digital mass flow controller |
| Cooling Time (1000 °C → 50 °C) | ≤20 min |
| Temperature Resolution | 0.1 °C |
| DSC Sensitivity | ±1000 mW |
| Furnace Material | Dual-wound Pt-Rh alloy heating element |
| Sensor | High-purity noble metal alloy microbalance sensor |
| Thermal Insulation | Dual-layer vacuum-insulated furnace housing |
| Integration Capability | FTIR coupling interface compliant with standard gas outlet port |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Mass Resolution | 1 µg |
| Mass Accuracy | ±1 µg |
| Dynamic Weighing Capacity | 0.01 mg–3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Load | 50 g |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA201 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.001 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 0.01 µg |
| Mass Accuracy | 0.01 mg |
| Heating Rate | 0.1–100 °C/min |
| Cooling Rate | –0.1 to –40 °C/min |
| Maximum Sample Mass | 30 g |
| Mass Precision | 0.01 mg |
| Temperature Stability | ±0.01 °C |
| Cooling Time (1000 °C → 50 °C) | ≤20 min (standard), ≤15 min with optional cryo-cooling unit |
| Atmosphere Control | Triple-gas mass flow controller |
| Data Acquisition Intervals | Real-time, 2 s, 5 s, or 10 s selectable |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3320A |
| Sample Capacity | Single |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV (expandable) |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Interface | USB bidirectional communication |
| Display | 7-inch 24-bit color LCD touchscreen |
| Sensor Material | Ni-Cr alloy thermocouple |
| Furnace Design | Top-opening vertical furnace |
| Atmosphere Control | Programmable internal gas switching |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ3500A |
| Price Range | USD 2,100 – 4,200 |
| Display | Color TFT Touchscreen |
| Furnace Tube Dimensions | Φ30 × 400 ±5 mm |
| Heating Element | High-Temperature Alloy Wire |
| Heating Zone Length | 200 mm |
| Uniform Temperature Zone Length | 150 mm |
| Operating Temperature Range | Ambient to 990 °C |
| Temperature Control | Intelligent Programmable PID Controller |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ3500S |
| Pricing | Available Upon Request |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient temperature operation |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±1% |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms | Solids (bulk, metallic, thin films), powders, granules, liquids, gels, pastes, and insulating materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Test Environment | Ambient temperature (with optional environmental chamber integration) |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | –30 °C to 200 °C |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% RSD |
| Accuracy | ±2% (traceable to NIST-certified reference materials) |
| Sample Forms | Solids (bulk, thin films, foams), liquids, powders, pastes, gels, and elastomers |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Display | 7-inch color capacitive touchscreen interface |
| Control Architecture | Bidirectional software–instrument communication (USB/Ethernet) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Temperature Range | −40 °C to 200 °C |
| Accuracy | ±0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Measurement Time | ≤160 s |
| Sample Forms | Solids (blocks, metals, films), Liquids, Powders, Gels, Pastes, and Insulating Materials |
| Sample Requirements | Surface must be flat and smooth |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Power Consumption | <300 W |
| Solid Sample Dimensions (Probe #1) | ≥15 mm × 15 mm × 3.75 mm |
| Solid Sample Dimensions (Probe #2) | ≥30 mm × 30 mm × 7.5 mm |
| Liquid/Powder Sample Volume | 18 mL (with dedicated fixture) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Operating Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.0001 W/(m·K) |
| Temperature Range | −40 °C to 200 °C (expandable) |
| Sample Form Compatibility | Solid blocks, metals, liquids, powders, gels, pastes, thin films, thermal insulation materials, alloys, ores, polymers, and foams |
| Test Duration | <160 s |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Sample Dimensions | Probe #1: 7.5 × 7.5 × 3.75 mm |
| Probe #2 | 15 × 15 × 7.5 mm |
| Power Supply | AC 220 V |
| Max. Power Consumption | <300 W |
| Max. Sample Temperature Rise | <20 °C |
| Probe Power Range | Probe #1: 0–1 W |
| Probe #2 | 0–15 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Temperature Range | −40 °C to +200 °C (expandable) |
| Sample Forms | Solid blocks, metals, liquids, powders, pastes, gels, thin films, foams, polymers, alloys, minerals, and thermal insulation materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.00001 W/(m·K) |
| Test Atmosphere | Ambient air (no controlled atmosphere) |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms Supported | Solids (bulk, metallic), liquids, powders, pastes, gels, thin films, and aerogels |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature (standard) |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Sample Forms | Solid blocks, pastes, granular solids, gels, liquids, powders, coatings, thin films, and thermal insulation materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC100A |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Gas Flow Control | 0–200 mL/min (digital mass flow meter) |
| DSC Sensitivity | 0.01 mW |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Interface | USB 2.0 bidirectional communication |
| Control Architecture | ARM Cortex-M3 microcontroller |
| Calibration | Integrated standard reference materials with one-click temperature & enthalpy calibration |
| Power Supply | AC 220 V / 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC300C |
| Temperature Range | −40 to 600 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Signal Range | 0–±800 mW (expandable) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual-gas auto-switching (up to 200 mL/min, ≤0.5 MPa), plus inert purge line |
| Data Interface | USB 2.0 with auto-reconnect |
| Display | 7-inch 24-bit color touchscreen |
| Calibration Standards Included | Indium, Tin, Lead |
| Power Supply | AC 220 V / 50 Hz (customizable) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Balance Resolution | 0.01 mg |
| DSC Range | ±800 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Display | 7-inch 24-bit color touchscreen |
| Software | Integrated thermal analysis suite with TG, DTG, DSC, and TG-DSC overlay |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA300 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.001 °C |
| Max Sample Mass | 30 g |
| DSC Sensitivity | 0.001 mW |
| Mass Resolution | 0.01 mg |
| Atmosphere Control | Integrated Digital Mass Flow Controller |
| Data Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Coupling Technology | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | N₂ (digital mass flow controller) |
| Weight Resolution | 0.1 µg |
| DSC Sensitivity | ±1000 mW |
| Weighing Range | 0.01 mg–3 g (expandable to 50 g) |
| Weight Accuracy | 1 µg |
| Cooling Time (1000 °C → 50 °C) | ≤20 min |
| Temperature Resolution | 0.1 °C |
| Control Method | Intelligent PID |