HORIBA
Filter
Showing 271–300 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HP-200 |
| IP Rating | IP65 |
| Measurement Principle | Glass Electrode Method |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Repeatability | ±0.03 |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (equivalent input) |
| Output | Two isolated 4–20 mA DC outputs (max load: 900 Ω) |
| Relay Outputs | 5 SPDT (1c) contacts, configurable for alarm/control |
| Input | Dry-contact hold input for electrode cleaning/operation status |
| Communication | RS-485 (2-wire, input/output isolated) |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤15 W |
| Enclosure Material | Aluminum alloy |
| Mounting | Pole (Ø50 mm) or wall-mount |
| Ambient Operating Temperature | −20 to +55 °C |
| Weight | ~4.5 kg |
| Compliance | CE, FCC, RoHS, WEEE |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HP-300 |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Repeatability | ±0.03 |
| pH Linearity | ±0.03 |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C (equivalent input) |
| Output | 4–20 mA DC, isolated, max. load resistance 600 Ω |
| Power Supply | 24 V DC (21–32 V DC), max. 0.6 W |
| Enclosure Rating | IP65 |
| Ambient Operating Temperature | −20 to +60 °C |
| Housing Material | Aluminum alloy |
| Mounting | Pipe (50A) or wall-mounted |
| Weight | ~4 kg |
| Compliance | CE, FCC, RoHS, WEEE |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HP-480 |
| Measuring Range (pH) | 0–14 |
| Resolution (pH) | 0.01 pH |
| Temperature Range | 0–100 °C |
| Resolution (Temperature) | 1 °C (selectable display) |
| Repeatability (pH) | ±0.05 pH (at equivalent input) |
| Output | 4–20 mA DC, isolated, max. load resistance 900 Ω |
| Relay Outputs | 2 points (SPDT, 240 V AC / 30 V DC, 3 A) |
| Calibration | 2-point auto-calibration (using standard buffers pH 2, 4, 7, 9, 10) and manual calibration |
| Temperature Compensation | Automatic, selectable sensor types (500 Ω, 6.8 kΩ, 350 Ω, 1 kΩ, 10 kΩ) or none |
| Enclosure Rating | IP65 (panel mount) |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤10 VA |
| Environmental Operating Range | −5 to +45 °C |
| Compliance | CE, FCC, RoHS |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HP-480 |
| Measurement Principle | Glass Electrode Method |
| pH Range | 0–14 |
| pH Resolution | 0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 1 °C (selectable display) |
| Accuracy (pH) | ±0.05 pH (equivalent input) |
| Linearity (pH) | ±0.05 pH (equivalent input) |
| Output Signal | 4–20 mA DC, isolated, max load ≤ 600 Ω |
| Relay Outputs | 2 × SPDT (240 V AC / 30 V DC, 3 A resistive) |
| Calibration | 2-point auto/manual (pH 2/4/7/9/10 JIS standards) |
| Temperature Compensation | Selectable RTD types (350 Ω, 500 Ω, 1 kΩ, 6.8 kΩ, 10 kΩ) or none |
| Self-Diagnosis | Asymmetry potential, slope deviation, response time anomaly, reference junction fault, sensor open/short, out-of-range detection |
| Enclosure Rating | IP65 (panel-mounted, indoor use) |
| Operating Ambient | −5 to +45 °C |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤10 W |
| Certifications | CE, FCC |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HR-200 |
| Measurement Principle | Amperometric (Polarographic) |
| Range | 0–3 mg/L Cl₂ |
| Resolution | 0.01 mg/L |
| Repeatability | ±0.05 mg/L (max) |
| Linearity | ±0.05 mg/L (max) |
| Temperature Range | 0–50 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C |
| Output | Two isolated 4–20 mA DC (max load 900 Ω) |
| Relay Outputs | 3 SPDT (1c), configurable for alarm/control/clean activation |
| Digital Interface | RS-485 (2-wire, input/output isolated) |
| Enclosure Rating | IP65 |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤35 VA |
| Operating Ambient | 0–55 °C |
| Weight | ~4.5 kg |
| Compliance | CE, FCC, RoHS, WEEE |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HR-400 |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HR-480 |
| Measurement Principle | Galvanic Cell (Electrochemical) |
| Measurand | Free Residual Chlorine |
| Range | 0–2 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ±0.05 mg/L (max) |
| Linearity | ±0.05 mg/L (max) |
| Output | Isolated 4–20 mA DC (max load: 900 Ω) |
| Relay Outputs | 2 × SPDT (240 V AC / 30 V DC, 3 A) |
| Enclosure Rating | IP65 |
| Certifications | CE, FCC, RoHS, WEEE |
| Operating Temperature | −5 to +45 °C |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤10 W |
| Compatible Sensor | HORIBA RS-1 Free Chlorine Electrode |
| Calibration | Zero calibration (using zero solution), Span calibration (against DPD colorimetric reference) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HU-200SS |
| Measurement Principle | Optical Transmission (Infrared LED Light Path) |
| Measuring Range (MLSS) | 0–20,000 mg/L |
| Resolution | 1 mg/L (0–10,000 mg/L), 10 mg/L (10,000–22,000 mg/L) |
| Accuracy | ±3% of reading or ±10 mg/L (whichever is greater) |
| Output | Isolated 4–20 mA DC (max. load 900 Ω) |
| Relay Outputs | 3 SPDT dry contacts (configurable for alarm, cleaning, fault) |
| Digital Interface | RS-485 (2-wire, input/output isolated) |
| Enclosure Rating | IP65 |
| Ambient Operating Temperature | −20 °C to +55 °C |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤35 VA |
| Weight | Approx. 4.5 kg |
| Compliance | CE, FCC, RoHS, WEEE |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HU-200TB |
| Measurement Principle | Dual-source 90° light scattering |
| Turbidity Range (Formazin) | 0–1000 NTU |
| Resolution | 0.1 NTU (10–100 NTU range) |
| Repeatability | ±2% or ±0.04 NTU (whichever is greater) |
| Linearity Deviation | ±2% or ±0.04 NTU at mid-range calibration point |
| Output | Isolated 4–20 mA DC (max load 900 Ω) |
| Relay Outputs | 3 SPDT dry contacts (configurable for alarm, cleaning activation, or fault indication) |
| Digital Interface | RS-485 (2-wire, input/output isolated) |
| Enclosure Rating | IP65 |
| Compliance | CE, FCC, RoHS, WEEE |
| Operating Temperature | 0–55 °C |
| Power Supply | 90–264 V AC, 50/60 Hz, ≤35 VA |
| Weight | ~4.5 kg |
| Housing Material | Aluminum alloy |
| Mounting | Pole-mounted (50A pipe) or wall-mount |
| Cleaning System | Motor-driven wiper (integrated, converter-triggered) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HU-200TB |
| Type | Online Turbidimeter |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Operating Ambient Temperature | ±25 °C |
| Accuracy | ±1% of reading |
| Optical Configuration | Quadruple-light-path detection system |
| Compliance | Designed for continuous process monitoring in water treatment and environmental applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-320 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 0.1 GU |
| Accuracy | ±0.5% F.S. ±1 digit |
| Spot Size | 16 mm × 12 mm |
| Display | LED numeric |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W×H×D) | 78 × 189 × 58 mm |
| Calibration | Automatic self-calibration with reference standard recognition |
| Detector Design | Detachable sensor head |
| Data Memory | Stores up to 99 measurement points with statistical analysis (mean, standard deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-320 |
| Measurement Angle | 60° |
| Gloss Range | 0–100 GU |
| Resolution | 0.1 GU |
| Accuracy | ±0.5% F.S. ±1 digit |
| Spot Size | 16 × 12 mm |
| Repeatability (Haze) | 0.2% |
| Repeatability (Transmittance) | 0.5% |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Power Supply | 9 V DC battery |
| Dimensions (W × H × D) | 78 × 189 × 58 mm |
| Display | LED digital |
| Calibration | Auto-calibration with detachable sensor head |
| Data Memory | Stores up to 99 readings with statistical functions (mean, standard deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-331 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 1 GU |
| Accuracy | ±5% F.S. ±1 digit |
| Spot Size | 16 mm × 12 mm |
| Display | LED numeric |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W×H×D) | 78 × 189 × 58 mm |
| Calibration | Auto-recognition calibration system |
| Data Memory | Up to 99 measurement points with statistical functions (mean, mean deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-331 |
| Measurement Angle | 60° |
| Measurement Range | 0–100 GU |
| Resolution | 1 GU |
| Accuracy | ±5% F.S. ±1 digit |
| Spot Size | 16 × 12 mm |
| Display | LED digital |
| Power Supply | 9 V DC battery (1 pc) |
| Dimensions (W × H × D) | 78 × 189 × 58 mm |
| Calibration | Auto-calibration with reference standard recognition |
| Detector Design | Separated sensor head for flexible positioning |
| Data Memory | Stores up to 99 readings with statistical functions (mean, mean deviation) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IG-340 |
| Type | Automatic Portable Gloss Meter |
| Gloss Range | 0.0–100.0 GU (60° geometry) |
| Display Range | 0.0–199.9 GU (OVER indication above 100.0) |
| Repeatability | ±0.6 GU (±0.5% of full scale ±1 digit) |
| Measurement Area | 6 × 12 mm elliptical spot |
| Measurement Angle | 60° |
| Light Source | LED (880 nm) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 35–85% RH (non-condensing) |
| Ingress Protection | IP42 |
| Power Supply | 2 × AA batteries |
| Dimensions | 61 × 62 × 176 mm |
| Weight | ≤320 g (including batteries and protective cap) |
| Memory Capacity | 100 single readings + 200 averaged datasets (with timestamp) |
| Data Interface | USB (Windows 10 compatible, bulk export supported) |
| Accessories | Calibration standard plate integrated in protective cap, soft carrying case, lens cleaning cloth |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | IGA Array |
| Pricing | Available Upon Request |
| Spectral Range | 0.8–1.7 µm and 1.0–2.2 µm |
| Cooling Options | Thermoelectric (TE) or Liquid Nitrogen (LN₂) |
| Pixel Configurations | 512×1, 1024×1 |
| Pixel Sizes | 25 µm × 250 µm, 25 µm × 500 µm, 50 µm × 250 µm, 50 µm × 500 µm |
| Operating Temperature (LN₂) | –103 °C |
| Software Integration | SynerJY®, SDK, LabVIEW® VIs |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iHR320 / iHR550 |
| Application System | Universal |
| Grating Mount | Dual-grating turret (motorized, selectable) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Wavelength Range | 150 nm – 40 µm |
| F-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Wavelength Accuracy | ±0.20 nm |
| Stray Light | 1.5 × 10⁻⁴ (iHR320), 1.0 × 10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | iHR320 / iHR550 |
| Focal Length | 320 mm (iHR320), 550 mm (iHR550) |
| f-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Grating Size | 68 mm × 68 mm (iHR320), 76 mm × 76 mm (iHR550) |
| Stray Light | 1.5×10⁻⁴ (iHR320), 1.0×10⁻⁵ (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IM-1000E |
| Regulatory Certifications | CCAEPI-EP-2011-075, Shanghai Metrology Type Approval Certificate No. 沪制02220125, 2010F344-31 & 2009-189 |
| Core Analyzers | HORIBA ENDA-600ZG Gas Analyzer, Fixed-source Particulate Monitor, Volumetric Flow Meter |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Type | Import |
| Model Range | 8001-10C, 6560-10C, 8002-10C, 8003-10C, 8004-10C, 8005-10C, 8006-10C, 8007-10C, 8008-10C, 8009-10C, 6561-10C, 8010-10C, 8011-10C, 5002A-10C, 1512A-10C, 6581-10C, 8201-10C, 6582-10C, 8202-10C, 6583-10C, 8203-10C, and corresponding electrode cartridges (e.g., 7660, 7661, 7681–7683) |
| Compatible Instruments | HORIBA F-72 / F-73 / F-74 / F-74BW benchtop analyzers |
| Reference Electrodes Required | 2060A and/or 2565A (except for composite electrodes) |
| Measurement Principle | Potentiometric ion-selective membrane sensing per IUPAC guidelines |
| Compliance | Designed for ASTM D1129, ISO 10523, USP <791>, and EPA Method 300.0 applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA / 0–10 V) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE-marked, RoHS-compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA or 0–10 V selectable) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE marked, RoHS compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 °C to 1000 °C |
| Measurement Time | 1–2 s |
| Spot Size (S-type) | Ø25 mm |
| Optical Resolution | High |
| Indication Method | Dual-Beam Laser Pointer |
| Mounting | Handheld / Optional Tripod Mount |
| Compliance | CE, RoHS, JIS C 1607-1 (Infrared Thermometers) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 °C to 1000 °C |
| Measurement Accuracy | ±1.5 °C or ±1.5% of reading (whichever is greater) |
| Response Time | ≤2 s |
| Spot Size | Φ25 mm at specified working distance (S-type optics) |
| Optical Resolution (D | S): 50:1 |
| Spectral Response | 8–14 µm |
| Emissivity Adjustment | 0.10–1.00 (0.01 step) |
| Display Resolution | 0.1 °C/°F |
| Power Supply | 2 × AA batteries |
| Operating Environment | –10 °C to 50 °C, <85% RH non-condensing |
| Weight | 220 g |
| Dimensions | 170 × 110 × 45 mm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 to 1000 °C |
| Measurement Principle | Dual-wavelength infrared radiometry |
| Response Time | ≤2 s |
| Spot Size (S-type) | Ø25 mm at specified working distance |
| Optical Resolution | High spatial resolution for small-area targeting |
| Indication Method | Dual-beam laser pointer system |
| Compliance | Designed per IEC 61215-2 (industrial thermometry), meets ISO 18434-1 guidelines for condition monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 15:1 (1 m → Ø24 mm) |
| Emissivity Adjustment Range | 0.10–1.00 (0.01 step) |
| Repeatability | ±0.5 °C or ±0.5 % of reading (whichever is greater) |
| Response Time (t₉₀) | ≤250 ms |
| Operating Ambient Temperature | 0 to 50 °C |
| IP Rating | IP54 (optional drip-proof housing available) |
| Output Interface | Analog 4–20 mA / 0–5 V DC + RS-485 Modbus RTU |
| Compliance | HACCP-aligned design, CE marked, RoHS compliant |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 50:1 |
| Spot Size at 1 m | Ø24 mm |
| Emissivity Adjustment Range | 0.10–1.00 (adjustable in 0.01 steps) |
| Response Time | ≤2 s |
| Output Interface | Optional RS-485 / 4–20 mA analog output |
| Enclosure Rating | IP65 (drip-proof configuration available) |
| Compliance | HACCP-aligned design for food safety monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 15:1 (1 m → Ø24 mm) |
| Emissivity Adjustment Range | 0.10–1.00 (0.01 step) |
| Accuracy | ±1.5 °C or ±1.5 % of reading (whichever is greater, at 23 ±5 °C ambient) |
| Repeatability | ±0.5 °C |
| Response Time (t₉₀) | ≤250 ms |
| Operating Ambient Temperature | 0 to 50 °C |
| IP Rating | IP54 (optional drip-proof configuration available) |
| Output Interface | Analog 4–20 mA / 0–5 V DC (configurable), RS-485 Modbus RTU |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Auto SE |
| Spectral Range | 450–1000 nm |
| Incident Angle | 70° |
| Sample Stage | Motorized XYZ Translation (200 mm × 200 mm travel, Z-height > 35 mm) |
| Detection | CCD-based Full-Spectrum Acquisition |
| Optical Architecture | Liquid-Crystal Variable Retarder (LCVR) Modulation, No Moving Parts in Measurement Path |
| Spot Visualization | Integrated Real-Time Imaging System |
| Compliance | Designed for ISO/IEC 17025-aligned QC environments, supports audit-ready data logging per GLP/GMP principles |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Gold-Coated Grating |
| Pricing | Upon Request |
| Type | Replica and Master Grating |
| Maximum Size | 1450 × 700 mm |
| Spectral Range | 600–1600 nm |
| Optimized Wavelengths | 800 nm, 1053 nm, 1550 nm |
| Groove Density | 1200, 1480, 1740 grooves/mm |
| Diffraction Efficiency | 90–95% |
| Substrate Materials | Fused Silica, Heat-Resistant Glass, ULE®, Zerodur®, Metal |
| Coating | High-Purity Gold (Au) |