HORIBA
Filter
Showing 301–330 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | H20-UVL |
| Spectral Range (Vacuum) | 100–400 nm (3–12.4 eV) |
| Spectral Range (Atmospheric) | 190–400 nm (3–6.5 eV) |
| Focal Length | 200 mm |
| f/# | f/4.2 |
| Grating Type | HJY4 aberration-corrected concave grating |
| Groove Density | 1200 gr/mm |
| Deviation Angle | 64° |
| Linear Dispersion at 100 nm | 3.6 nm/mm |
| Minimum Step Size | 0.06 nm |
| Scanning Speed | up to 400 nm/s |
| Wavelength Accuracy | ±0.2 nm (±0.06 nm with software calibration) |
| Repeatability | ±0.06 nm |
| Resolution (10 µm slit, 2 mm height, 121 nm) | <0.5 nm |
| Base Vacuum | ≤1×10⁻⁵ mbar (vacuum pump and gauge not included) |
| Vacuum Flange | DN40 KF (pump), DN25 KF (input/output) |
| Slit Width Range | 10 µm – 2 mm |
| Slit Height Options | 2, 4, or 6 mm |
| Optical Interfaces | Pre- and post-monochromator mirror chambers with toroidal mirrors |
| Sample Chamber | Accommodates up to four Ø25 mm samples |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HCLUE |
| Spectral Range (with dual detectors) | 185–2500 nm |
| Coupling Method | Mirror-based direct coupling |
| Detector Configuration | Dual-detector compatible |
| Spectrometer Focal Length Options | 320 mm, 500 mm, 550 mm |
| Grating Options | Multiple selectable gratings |
| Measurement Modes | Point spectrum, line scan, hyperspectral mapping |
| Compliance | Designed for integration with SEM/FIB platforms per ISO 16700 (electron probe microanalysis) and ASTM E1508 (quantitative cathodoluminescence) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | IGA array |
| Spectral Range | 0.8–1.7 µm or 1.0–2.2 µm |
| Pixel Configurations | 512× or 1024× (pixel pitch: 125 µm or 150 µm × 250 µm or 500 µm) |
| Cooling Options | Thermoelectric (TE) or Liquid Nitrogen (LN₂) |
| Operating Temperature (LN₂) | –103 °C |
| Interface | USB 2.0 / Camera Link (configurable) |
| Software Integration | SynerJY® SDK, LabVIEW® VIs |
| Compliance | CE, RoHS |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | iHR320 / iHR550 |
| Application System | Fluorescence Spectroscopy |
| Grating Mount | Dual-grating turret |
| Stray Light | 1.5×10⁻⁴ (iHR320) / 1×10⁻⁵ (iHR550) |
| Focal Length | 320 mm (iHR320), 550 mm (iHR550) |
| f-number | f/4.1 (iHR320), f/6.4 (iHR550) |
| Spectral Resolution | 0.06 nm (iHR320), 0.025 nm (iHR550) |
| Linear Dispersion | 2.31 nm/mm (iHR320), 1.34 nm/mm (iHR550) |
| Grating Size | 68 mm × 68 mm (iHR320), 76 mm × 76 mm (iHR550) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Type | OEM Custom Spectrograph/Monochromator |
| Spectral Range | 190–2100 nm |
| Focal Length | 20–140 mm |
| Resolution | 10–1 nm |
| Detector Options | Single-Channel PMT, Linear/2D Array, CCD, CMOS, NMOS, PDA, InGaAs |
| Optical Design | Monolithic Aberration-Corrected Platform |
| Grating Type | Type-4 Achromatic Grating |
| Compliance | Designed for Integration into CE/FCC-Compliant Analytical Systems |
| Manufacturing | High-Volume Production with Lot-to-Lot Performance Traceability |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Volume-Production Grating |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Space-Grade Diffraction Grating |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Standard Plane Grating |
| Pricing | Upon Request |
| Type | Replicated Grating |
| Dimensions | 120 × 140 mm |
| Spectral Range | 100 nm – 45 µm |
| Groove Density | 20 – 5670 grooves/mm |
| Diffraction Efficiency | 30% – 90% |
| Substrate Materials | Fused Silica, Heat-Resistant Glass, Zerodur®, Metal |
| Coating Options | Aluminum, Gold, Platinum, Magnesium Fluoride |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Symphony CCD |
| Cooling | Liquid Nitrogen |
| Sensor Architecture | Front-Illuminated (FI) / Back-Illuminated (BI) / Deep-Depletion (DD) |
| Resolution Options | 1024×256, 2048×512 |
| Pixel Types | UV-Enhanced, Vis-Enhanced, Open Electrode |
| ADC | 16-bit, 20 kHz – 1 MHz readout |
| Interface | Gigabit Ethernet |
| Onboard Memory | Yes |
| Software Control | SynerJY, LabVIEW VI |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows per ISO/IEC 17025 and ASTM E131–22 guidance |
| Key | Brand: HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synchrotron-Optimized Grating |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | T64000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | UV–VIS–NIR (excitation-dependent) |
| Spectral Resolution | ≤ 0.15 cm⁻¹ (triple-add mode) |
| Low-Wavenumber Limit | ≥ 5 cm⁻¹ (triple-subtract mode) |
| Spatial Resolution | Sub-micron (confocal, diffraction-limited) |
| Focal Length | 640 mm (single stage), 3 × 640 mm (triple stage) |
| Detector | Research-grade air-cooled large-format CCD |
| Laser Power Control | Multi-step neutral density attenuation |
| Optical Output | Flat-field dispersive output compatible with large-area detectors |
| Polarization Options | Full-suite polarization accessories (excitation, Raman, white-light) |
| Sample Handling | Integrated research microscope + large sample chamber |
| Optional Accessories | XYZ high-precision motorized stage, cryo/heat stages, fiber-optic probes, fast mapping module, simultaneous Stokes/anti-Stokes detection port, secondary detector outlet for PL/NIR-Raman |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | TGM300 |
| Spectral Range | 10–300 nm (configurable via interchangeable gratings) |
| Focal Length | 320 mm |
| f-number | f/10 |
| Optical Design | Monolithic toroidal grating monochromator with HJY aberration-corrected toroidal gratings |
| Vacuum Compatibility | UHV up to 1×10⁻⁹ mbar |
| Grating Options | Three standard gratings (550 gr/mm: 10–50 nm & 15–150 nm |
| 275 gr/mm | 50–300 nm) |
| Resolution | ≤0.4 nm (at 15 nm, using 550 gr/mm grating) |
| Slit Integration | Motorized or manual micrometer-driven entrance/exit slits |
| Grating Exchange | In-vacuum dual-grating turret |
| Optional Accessories | Pre-mirror chamber (2 toroidal mirrors), post-mirror chamber (2 toroidal mirrors), sample chamber (4× Ø25 mm positions), polarization insertion optics, 4 K cryostat, DN100LF vacuum flange, DN40KF vacuum gauge port |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | UVISEL 2 |
| Spectral Range | 190–2100 nm |
| Minimum Spot Size | 35 × 85 µm |
| Sample Stage | 200 mm × 200 mm with Motorized XYZ Translation and Auto-Leveling |
| Incidence Angle Range | 35°–90° (Auto-Adjustable, 0.01° Minimum Step) |
| Detector Configuration | Three Independent Detectors (UV-Optimized, VIS-Optimized, NIR-Optimized) |
| Optical Architecture | Dual-Grating Spectrometer with High Stray-Light Suppression |
| Modulation Technology | 50 kHz Photoelastic Modulator (PEM) |
| Imaging Capability | Integrated Visible Microscope with Real-Time Spot Visualization |
| Beam Delivery | Fixed-Path, No Moving Elements in Measurement Light Path |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | VHR640 / VHR1000 |
| Focal Length | 640 mm / 1000 mm |
| Input/Output Ports | Dual entrance & dual exit |
| Grating Mount | Turret with dual gratings |
| Optical Design | Czerny–Turner |
| Wavelength Range | 100 nm – 15 µm (grating-dependent) |
| Spectral Resolution (10 µm slit) | 0.016 nm (VHR640) / 0.010 nm (VHR1000) |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Spectral Dispersion | 1.2 nm/mm (VHR640) / 0.8 nm/mm (VHR1000) |
| Entrance F/# | f/5.4 (VHR640) / f/9.0 (VHR1000) |
| Grating Size (single-grating mode) | 110 mm × 110 mm |
| Grating Size (dual-grating mode) | 80 mm × 110 mm |
| Slit Range | 0–2 mm (micrometer-adjustable) |
| Vacuum Compatibility | <1×10⁻⁵ mbar |
| Vacuum Flanges | DN25 KF (pump & gauge), DN63 LF (slit), DN100 LF (CCD), PC interface (RS232 to USB) |
| Dimensions (L×W×H) | 740×350×350 mm (VHR640) / 1160×430×350 mm (VHR1000) |
| Mass | 65 kg (VHR640) / 70 kg (VHR1000) |
| Optional Accessories | Pre-mirror chamber (two toroidal mirrors), Post-mirror chamber (two toroidal mirrors), Sample chamber (up to four 25 mm Ø samples), Polarizer inserts, 4 K cryostat, Vacuum pump |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | 200 nm – 1050 nm |
| Spectral Resolution (UV-Vis) | 2.7 nm @ 75 µm slit, 2048-pixel array |
| Numerical Aperture | f/2.8 |
| Stray Light Suppression | ≤ 0.08% (max) |
| Dynamic Range | 7000:1 |
| Quantum Efficiency | >65% at 250 nm, >70% at 650 nm, >55% at 850 nm |
| Readout Speed | up to 223 spectra/s (ultra-fast mode, zero exposure) |
| A/D Conversion | 16-bit, 500 kHz |
| Dark Current | 2.8 counts/ms @ 20°C |
| Read Noise | ≤45 e⁻ (sensitive mode), ≤90 e⁻ (high full-well mode) |
| Linearity Error (factory corrected) | <0.4% (sensitive mode), <0.8% (high full-well mode) |
| On-board Linearization & Wavelength Calibration | Yes |
| Interface | USB 2.0 |
| Optical Design | Monolithic aberration-corrected Czerny–Turner with Type-4 flat-field concave holographic grating |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Application System | Fluorescence Spectroscopy |
| Grating Mount | Motorized or Fixed Grating Turret (OEM Configurable) |
| Spectral Resolution | 0.33 nm/pixel (at 75 µm slit, 2048-pixel CCD, UV-VIS configuration) |
| Dispersion | ~1.6 nm/mm (typical, dependent on grating and focal length) |
| Wavelength Range | 200–1050 nm (configurable via grating & filter options) |
| F/# | f/2.8 |
| Wavelength Accuracy | ±0.2 nm (calibrated, traceable to NIST standards) |
| Stray Light | <0.04% (typical), <0.08% (max), measured with 300 µm UV-VIS CCD, 510 nm bandpass filter, 75 µm slit |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | VUV Grating |
| Pricing | Available Upon Request |
| Diffraction Efficiency | High |
| Stray Light Level | Low |
| Optical Surface Types | Plane, Spherical, Toroidal |
| Grating Types | Monochromator Grating, Spectrograph Grating |
| Aberration Correction | Variable Line Spacing (VLS) |
| Coating Materials | Gold, Platinum, Magnesium Fluoride (MgF₂) |
| Substrate Materials | Silicon, Fused Silica |
| Spectral Range | 1–200 nm |
| Brand | HORIBA |
|---|---|
| Model | 1000M / 1250M |
| Focal Length | 1000 mm / 1250 mm |
| F-number | f/8 / f/9 |
| Spectral Resolution | 0.008 nm (1000M) / 0.006 nm (1250M) |
| Linear Dispersion | 0.8 nm/mm (1000M) / 0.65 nm/mm (1250M) |
| Grating Size | 110 mm × 110 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.005 nm |
| Slit Adjustment Range | 0–3 mm (2 µm step resolution) |
| Step Resolution | 0.00025 nm |
| Input/Output Ports | Dual entrance & dual exit with motorized mirror switching |
| Grating Mount | Manual or motorized interchangeable grating turret |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Flex-CLUE |
| Spectral Range | 200–1000 nm or 400–1700 nm |
| Optical Coupling | Fiber-coupled |
| Spectrometer Focal Length Options | 140 mm, 200 mm, 320 mm |
| Grating Options | Multiple selectable |
| Measurement Modes | Point acquisition, line scan, hyperspectral mapping |
| Detector Compatibility | Open-electrode CCD, EMCCD, InGaAs arrays |
| Integration | SEM-compatible (FE-SEM, SEM, STEM) |
| Spatial Resolution | Sub-100 nm (dependent on electron beam conditions and sample properties) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HE |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | < 5 cm⁻¹ (typical, dependent on grating and slit configuration) |
| Spatial Resolution | Diffraction-limited, down to ~1 µm (with 50× long-working-distance objective and confocal option) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | < ±0.2 cm⁻¹ (over 8-hour operation, temperature-stabilized optics) |
| Detector | 1024 × 256 pixel CCD, MPP mode |
| Cooling | Peltier-cooled to −70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Wavelength Options | 532 nm, 633 nm, 785 nm |
| Laser Power Range | 80–300+ mW (adjustable per application) |
| Fiber Probe Support | Up to 4 simultaneous SuperHead™ probes |
| Software | LabSpec 6 (Windows-compatible, FDA 21 CFR Part 11–ready audit trail & user access control) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | In-situ Series |
| Application | In-line thin-film process monitoring during deposition and etching |
| Measurement Principle | Spectroscopic ellipsometry (SE) |
| Optical Configuration | Fiber-coupled, modular probe head design for integration into vacuum chambers or CVD/PVD/ALD tools |
| Spectral Range | Typically 190–1700 nm (configurable per system variant) |
| Spot Size | Adjustable, down to ~50 µm (dependent on optical interface and working distance) |
| Angle of Incidence | Fixed or motorized, commonly 65°–75° (customizable per integration requirement) |
| Measurement Speed | Up to 10 Hz spectral acquisition (full spectrum), sub-second single-wavelength monitoring |
| Single-Measurement Time | <100 ms (at fixed wavelength) |
| Sample Compatibility | Wafers up to 300 mm, flat or curved substrates, high-temperature or cryogenic environments (with optional thermal management) |
| Thickness Accuracy | ±0.1 nm (for SiO₂ on Si reference films, under controlled conditions) |
| Repeatability | <0.05 nm RMS over 24 h (thermal drift compensated) |
| n/k Determination Uncertainty | Δn < 0.002, Δk < 0.0005 (for transparent dielectrics) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicroHR |
| Focal Length | 140 mm |
| f/# | f/3.88 |
| Linear Dispersion | 5.25 nm/mm |
| Grating Format | Dual-position motorized or manual turret (32 mm × 32 mm) |
| Spectral Range | 180 nm – 20 µm (dependent on grating and detector selection) |
| Detector Interface | Compatible with CCD, PMT, and other single-channel detectors |
| Application Modes | Transmission, Reflection, Fluorescence, Laser Spectroscopy, In-situ & Field Deployment |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PGS/PGM 1000 |
| Application Modes | Transmission/Reflection Spectroscopy |
| Optical Configuration | Aberration-Corrected Plane Grating + Toroidal Mirror |
| Focal Length | 1000 mm |
| F-number | f/48 |
| Vacuum Compatibility | UHV up to 1×10⁻⁹ mbar |
| Wavelength Range | 4–125 nm (10–310 eV) |
| Resolution (typ.) | 0.02–0.3 nm (dependent on grating selection) |
| Grating Options | 550, 1800, 3600 grooves/mm |
| Exit Slit Interface | Adjustable micrometer slits, DN100 CF/ICF152 detector flange |
| Input/Output Flanges | DN63 LF (pump), DN100 CF (UHV pump), DN40 CF (vacuum gauge) |
| Motorized Wavelength Drive | Stepper motor with USB 2.0 interface |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 (at m/z 208, high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | <1 nm |
| Ion Mode | Positive and Negative |
| Flexible Ion Blanking | Up to 4 ions |
| Sample Loading | Horizontal, ambient-pressure compatible |
| Mass Coverage | H to U, including isotopes and molecular species |
| Analysis Mode | Pulsed RF sputtering with 3D depth profiling capability |
| Quantification | Matrix-effect-reduced semi-quantitative analysis without calibration standards |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Profiler 2 |
| Excitation Source | Pulsed RF Glow Discharge |
| Depth Range | 1 nm – 200 µm |
| Depth Resolution | < 1 nm |
| Elemental Coverage | ≥70 elements including C, H, O, N, Cl |
| Spectral Range | 110–800 nm |
| Spectral Resolution (Polyscan) | 18–25 pm |
| Detector | High Dynamic Detector (HDD), dynamic range 5×10¹⁰ |
| Compliance | ISO 14707, ISO 16962 |
| Software | Quantum v5.x with GLP/GMP audit trail support |
| Optional Configuration | Monochromator for n+1 flexible channel selection |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Profiler HR |
| Spectral Range | 110–800 nm |
| Resolution (Polyscan) | 14 pm |
| Resolution (Optional Monochromator) | 9 pm |
| Dynamic Detection Range | 5 × 10¹⁰ |
| Simultaneous Elements | Up to 60 |
| Compliant Standards | ISO 14707, ISO 16962 |
| Detector Type | High Dynamic Detector (HDD) |
| RF Generator | Standard RF Source with D-Class Amplifier Architecture |
| Sample Chamber | Large-volume, modular design for heterogeneous sample loading |
| Software | Quantum v5.x with GLP-compliant audit trail and report export (PDF, CSV, XML) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | VS20 |
| Optical Configuration | Czerny–Turner with concave holographic grating |
| Spectral Range | 200–1700 nm |
| Spectral Resolution | 6.5 nm (FWHM, typical) |
| Dispersion | 90 nm/mm |
| F/# | 2.7 |
| Wavelength Accuracy | < ±0.5 nm |
| Stray Light | < 0.25% @ 260 nm |
| Thermal Drift | < 0.03 nm/°C |
| Dimensions | 15 × 22 × 35 mm |
| Detector Compatibility | CMOS, CCD, InGaAs (e.g., Hamamatsu S837X, S390X, S1011X |
| Application Modes | Transmission & Reflection Spectroscopy |
| Compliance | RoHS-compliant optical housing, ISO 9001 manufacturing environment |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-300 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–600 µm |
| Repeatability | <1% |
| Measurement Time | 20 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LA-350 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 100 nm – 1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01–5000 µm |
| Repeatability | < 0.1% |
| Measurement Time | < 10 s |
| Compliance | ISO 13320 |
| Accuracy | ±0.6% |