HORIBA
Filter
Showing 331–360 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LA-960 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5 mm |
| Repeatability | ≤0.06% |
| Measurement Time | <1 min |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM HR Evolution |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Focal Length | 800 mm |
| Spectral Dispersion | Flat-field output optimized for large-format CCD detectors |
| Laser Power Control | Multi-step motorized neutral density filters |
| Detector | Research-grade air-cooled large-chip CCD |
| Low-Wavenumber Capability | Down to 10 cm⁻¹ |
| Spatial Resolution | Sub-micron (diffraction-limited, wavelength- and objective-dependent) |
| Automation | Fully motorized optical path, filter wheels, grating turrets, and XYZ stage |
| Software Platform | LabSpec 6 with embedded chemometrics, fluorescence subtraction, particle search, and audit-trail-ready data handling |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM HR Evolution |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–4000 cm⁻¹ |
| Spectral Resolution | 0.6 cm⁻¹ |
| Spatial Resolution | 400 nm |
| Low-Wavenumber Limit | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Focal Length | 800 mm |
| Excitation Wavelength Range | 200–2100 nm |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Design | Achromatic Flat-Field Spectrograph |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | LabRAM Odyssey |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.35–0.65 cm⁻¹ |
| Spatial Resolution | down to 250 nm |
| Minimum Wavenumber | as low as 3.5 cm⁻¹ |
| Spectral Reproducibility | ±0.02 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LabRAM Soleil™ |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–2100 nm |
| Spectral Resolution | 0.5 cm⁻¹ |
| Spatial Resolution | <250 nm |
| Minimum Wavenumber | <5 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.01 cm⁻¹ |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA |
| Instrument Type | Confocal Raman Microspectrometer |
| Laser Options | 532 nm, 638 nm, 785 nm (multi-laser integrated) |
| Grating Configuration | 4-position automated grating turret |
| Spectral Range | 100–4000 cm⁻¹ (dependent on laser/grating selection) |
| Optical Design | Flat-field spectrograph with large-format CCD detector |
| Laser Power Control | Multi-step neutral density attenuation |
| Microscope | Research-grade upright confocal microscope |
| Automation Level | Fully motorized stage, autofocus, auto-alignment, auto-calibration, auto-exposure |
| Imaging Modes | Raman mapping, fluorescence imaging, photoluminescence (PL) imaging |
| Optional Integrations | AFM coupling, polarization accessories, cryo/heat stages, liquid cells, macro sampling modules |
| Software | HORIBA LabSpec 6 with GO!™ guided workflow engine |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA INV |
| Instrument Type | Inverted Confocal Raman Microscope |
| Laser Options | 532 nm, 638 nm, 785 nm (3 internal lasers) |
| Grating Options | 600, 1200, 1800, 2400 gr/mm (motorized auto-switching) |
| Spectral Range | 250–10,000 cm⁻¹ (configurable per laser/grating combination) |
| Laser Power Control | Multi-step neutral density attenuation |
| Automation | Auto-focus, auto-exposure, auto-calibration, self-diagnostic routine |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Optional Modules | DuoScan™ high-speed Raman imaging, SWIFT™ fast spectral acquisition, epifluorescence integration, polarization optics, precision XYZ stage, environmental stages (cryo/heated/biological incubation), AFM/Raman coupling interface, fiber-optic probe compatibility |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA INV |
| Instrument Type | Inverted Confocal Raman Microscope |
| Laser Options | 532 nm, 638 nm, 785 nm (multi-laser auto-switching) |
| Grating Options | 4 gratings auto-switched (600, 1200, 1800, 2400 gr/mm) |
| Spectral Range | 250–10,000 cm⁻¹ (configurable per laser/grating combination) |
| Spatial Resolution | Sub-micron (diffraction-limited, dependent on objective and wavelength) |
| Automation | Auto-focus, auto-exposure, auto-calibration, self-diagnostic |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-supportive workflow logging |
| Optional Modules | DuoScan™ high-speed Raman imaging, SWIFT™ fast spectral acquisition, epifluorescence integration, polarization control, precision XYZ stage, environmental stages (cryo/heated/biological incubation), AFM-Raman coupling interface |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | LabRAM XploRA PLUS XS |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral 0.4 µm, Axial 1.5 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.03 cm⁻¹ |
| Maximum Acquisition Speed | 1600 spectra/s |
| Pixel Dwell Time | <1 ms/pixel |
| Automated Laser Selection | Up to 3 Integrated Lasers (532 nm, 638 nm, 785 nm) |
| Grating Options | 4 Motorized Gratings |
| Detection | EMCCD and XS Fast-Imaging Detector |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUA DO2000 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Galvanic Electrode (Clark-type) with Integrated Thermistor |
| DO Range | 0.0 to 60.00 mg/L, 0.0 to 600.0% saturation |
| DO Accuracy | ±0.1 mg/L, ±1.0% of reading |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Atmospheric Pressure Compensation | 10.0 to 200.0 kPa |
| BOD Protocol | Pre-programmed 5-day method with seed correction |
| Calibration Points | Up to 2-point DO calibration |
| Memory Capacity | 2000 data sets with timestamp |
| Display | 5-inch backlit 320-segment LCD |
| Connectivity | USB (for DAS20 software), RS-232C (for printer), BNC, ATC phono, DC input |
| Power | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DO2000 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Galvanic Cell (Electrochemical) |
| DO Range | 0.0 to 60.00 mg/L |
| DO Accuracy | ±0.1 mg/L |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Salt Compensation | 0.0–40.0 ppt |
| Pressure Compensation | 10.0–200.0 kPa |
| BOD Method | Standard 5-Day with Seed Correction |
| Memory Capacity | 2,000 Data Sets with Timestamp |
| Communication | USB (DAS20 Software), RS-232C (Printer) |
| Display | 5-inch Backlit LCD (320-segment) |
| Power | AC Adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | EC2000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | Conductivity (0.000 μS/cm to 2.000 S/cm), Resistivity (0.001 to 20.0 MΩ·cm), TDS (0.01 mg/L to 100 g/L), Salinity (0.0 to 100.0 ppt), Temperature (−30.0 to 130.0 °C) |
| Accuracy | ±0.6% FS (conductivity/resistivity), ±0.2% FS (salinity), ±0.5 °C (temperature) |
| Calibration | Up to 4-point auto or 5-point manual conductivity calibration |
| Data Logging | 2000 entries with real-time clock and timestamp |
| Interface | BNC, phono jack (USB/RS-232C), DC input |
| Display | 5″ backlit custom LCD (320 segments) |
| Power | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model Series | F-71A-S, F-72A-S, F-73A-S, F-74A-S |
| Measurement Parameters | pH, mV (ORP), Conductivity, Resistivity, Salinity, TDS, Temperature |
| Instrument Type | Laboratory Benchtop Water Quality Analyzer |
| Compliance | Designed for ISO/IEC 17025-compliant labs and GLP environments |
| Software Interface | USB and RS-232 connectivity for data export and instrument control |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F2000-S |
| Instrument Type | Benchtop Ion Meter |
| Ion Measured | Fluoride (F⁻) |
| Temperature Range | −30.0 to 130.0 °C |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.003 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Ion Concentration Range | 0.000 µg/L to 9999 g/L |
| Ion Resolution | 4 significant digits |
| Ion Accuracy | ±0.3% full scale or ±0.2 mV (whichever is greater) |
| Calibration Points | Up to 5 for pH/ion, up to 6 for DIN buffers |
| Temperature Accuracy | ±0.5 °C |
| Data Storage | 2000 records with timestamp |
| Connectivity | USB/RS-232C via phono jack |
| Display | 5" backlit custom LCD (320 segments) |
| Power | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ION2000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration (selectable units), Temperature (°C/°F) |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.003 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Ion Range | 0.000 μg/L to 9999 g/L |
| Ion Units | μg/L, mg/L, g/L, ppm, ppt, mmol/L, mol/L |
| Ion Resolution | 4 significant digits |
| Ion Accuracy | ±0.3% full scale or ±0.2 mV (whichever is greater) |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.5 °C / ±0.9 °F |
| Calibration Points | Up to 5 (pH/ORP), Up to 6 (DIN pH buffers) |
| Buffer Sets | USA, NIST, NIST2, DIN, Custom |
| Memory Capacity | 2000 data points |
| Data Logging | Automatic with real-time clock and timestamp |
| Measurement Modes | Auto-Stable, Auto-Hold, Real-Time |
| Display | 5″ custom LCD with backlight (320 segments) |
| Connectivity | BNC, phono (ATC), DC sockets |
| Power Supply | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PD2000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature (°C/°F) |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.003 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Ion Range | 0.000 µg/L to 9999 g/L |
| Ion Units | µg/L, mg/L, g/L, ppm, ppt, mmol/L, mol/L |
| DO Range | 0.0–60.00 mg/L / 0.0–600.0% |
| DO Resolution | 0.01 mg/L, 0.1% |
| DO Accuracy | ±0.1 mg/L or ±1.0% |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Memory Capacity | 2000 data sets with timestamp |
| Communication | USB (DAS20 software), RS232C (printer) |
| Display | 5″ backlit 320-segment LCD |
| Power | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 770 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH2000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Temperature (°C/°F) |
| pH Range | −2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.003 |
| pH Calibration Buffers | USA, NIST, NIST2, DIN, Custom |
| Max Calibration Points | 5 (USA/NIST/NIST2), 6 (DIN/Custom) |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.5 °C / ±0.9 °F |
| Memory Capacity | 2000 data points |
| Data Logging | Automatic with timestamp |
| Real-time Clock | Integrated |
| Measurement Modes | Auto-Stable, Auto-Hold, Real-Time |
| Electrode Status Indicator | On-screen |
| Diagnostic Functions | Built-in |
| Password Protection | Configurable |
| Communication Interfaces | BNC, Phono (ATC), DC sockets, USB/RS-232C via phono jack |
| Display | 5" custom LCD with backlight (320 segments) |
| Power Supply | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Product Type | Portable |
| Measurement Range | 0–2000 NTU |
| Resolution | 0.01 NTU (0.00–19.99 NTU), 0.1 NTU (20.0–199.9 NTU), 1 NTU (200–2000 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.02 NTU or ±2% (0.00–1000 NTU) |
| Calibration Points | Up to 4 (0.02, 20, 100, 800 NTU) |
| IP Rating | IP67 |
| Display | Backlit monochrome LCD |
| Data Storage | 2000 measurements with timestamp |
| Light Source | 860 nm infrared LED |
| Detector | Silicon photodiode |
| Sample Volume | 10 mL |
| Power | 4×AA batteries |
| Dimensions | 210 × 110 × 55 mm |
| Weight | 510 g (with batteries), 410 g (without) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUA200 Series |
| Type | Handheld Portable Water Quality Analyzer |
| Measured Parameters | pH, Electrical Conductivity (EC), Dissolved Oxygen (DO) |
| Display | 50 × 50 mm scratch-resistant LCD with white backlight |
| Housing Material | Polycarbonate + Thermoplastic Elastomer (TPE) |
| Compliance | IP67-rated enclosure (dust-tight and submersible up to 1 m for 30 min) |
| Operating Temperature | 0–50 °C |
| Battery Life | Up to 10,000 measurements per set of AAA batteries |
| Data Output | USB-C interface for PC connectivity and firmware updates |
| Calibration Support | Auto-buffer recognition for pH (pH 4.01, 7.00, 10.01), single- or two-point EC calibration, zero-point DO calibration in air-saturated water |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PC2000 |
| Instrument Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, TDS, Salinity, Temperature (°C/°F) |
| Calibration Standards | USA, NIST, NIST2, DIN, Custom |
| Data Storage | 2000 Points with Timestamp & RTC |
| Connectivity | USB / RS-232C |
| Display | 5" Backlit LCD (320 segments) |
| Power | AC Adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 770 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUAact D-70 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measuring Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Dissolved Oxygen (DO), Saturation DO, % Oxygen |
| pH Range | 0.00–14.00 (Display: −2.00–16.00) |
| pH Accuracy | ±0.01 pH |
| pH Repeatability | ±0.01 pH ±1 digit |
| mV Range | −2000–+2000 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C (Display: −30.0–130.0 °C) |
| Temp. Accuracy | ±0.1 °C |
| Conductivity Range | 0.0 μS/m–200.0 S/m |
| Conductivity Accuracy | ±0.05% FS |
| DO Range | 0.00–20.00 mg/L |
| DO Accuracy | ±0.01 mg/L |
| DO Repeatability | ±0.1 mg/L ±1 digit |
| IP Rating | IP67 |
| Data Storage | 1000 measurements with timestamp, ID, and parameter metadata |
| Communication | USB interface compliant with GLP/GMP data integrity requirements |
| Power | 2× AAA alkaline or Ni-MH rechargeable batteries (≈1000 h operation) |
| Dimensions | 67 × 28 × 170 mm (W×D×H, max thickness 80 mm) |
| Weight | ≈270 g (without batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-70 Series |
| Type | Portable / Handheld Water Quality Analyzer |
| Measured Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, Total Dissolved Solids (TDS), Dissolved Oxygen (DO) |
| Display | Backlit LCD with capacitive touchscreen |
| Protection Rating | IP67 (instrument and electrode) |
| Data Storage | 1,000 measurement records |
| Power Supply | AAA alkaline batteries, Ni-MH rechargeable batteries, or AC adapter |
| Calibration | Auto-calibration support |
| Compliance | JIS Z 8401 (pH), JIS K 0101 (conductivity), ISO 7888 (conductivity), ASTM D1125 (conductivity), USP <645> (water conductivity for pharmaceutical use) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-70 Series |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Dissolved Oxygen (DO), Saturation DO, % Oxygen |
| Display | Backlit Monochrome LCD |
| Protection Rating | IP67 |
| Data Storage | 1000 measurements |
| Communication | USB/RS-232 for GLP/GMP-compliant data export |
| Calibration | Auto-identification of 5-point pH buffers (USA/NIST), automatic temperature compensation, electrode diagnostics |
| Power | 2× AAA alkaline or Ni-MH rechargeable batteries (≈1000 h operation) |
| Dimensions | ~67 × 28 × 170 mm (W×D×H) |
| Weight | ~270–285 g (body only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-70 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Dissolved Oxygen (DO), Saturation DO, % Oxygen |
| Display | Backlit Monochrome LCD |
| Data Storage | 1,000 measurements |
| Environmental Rating | IP67 |
| Power | 2× AAA Alkaline/Ni-MH batteries or AC adapter |
| Operating Temperature | 0–45 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Compliance | JIS Z 8401 (pH), JIS K 0101 (conductivity), ISO 5667-3, ASTM D1293, ASTM D512, ASTM D1125, USP <645>, FDA 21 CFR Part 11 (with optional software & audit trail) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-70 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, Total Dissolved Solids (TDS), Dissolved Oxygen (DO) |
| Display | Backlit LCD with Capacitive Touchscreen |
| Protection Rating | IP67 (Instrument and Electrodes) |
| Data Storage | 1,000 measurement records |
| Power Supply | AAA alkaline batteries, Ni-MH rechargeable batteries, or AC adapter |
| Calibration Support | Auto-calibration prompts, 5-point pH calibration, NIST/USA standard compatibility, automatic temperature compensation (pH, conductivity, DO), pressure & salinity compensation (DO) |
| Compliance | JIS Z 8401 (pH), JIS K 0101 (conductivity), ISO 7888 (conductivity), ASTM D1125 (conductivity), USP <645> (water resistivity for pharmaceutical use) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Dissolved Oxygen (DO), Saturation DO, Oxygen Concentration |
| Display | Backlit Monochrome LCD |
| Protection Rating | IP67 |
| Data Storage | 1000 records |
| Power | 2 × AAA alkaline or Ni-MH batteries (≈1000 h battery life) |
| Dimensions | 67 × 28 × 170 mm (W × D × H) |
| Weight | ~270 g (without batteries) |
| Compliance | Supports GLP/GMP data integrity requirements |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | pH, mV (ORP), Conductivity, Resistivity, Salinity, TDS, Dissolved Oxygen (DO), Ion Concentration |
| Display | Backlit LCD with Capacitive Touchscreen |
| Protection Rating | IP67 (Instrument & Electrodes) |
| Data Storage | 1,000 measurements |
| Power Supply | AAA Alkaline/Ni-MH Batteries or AC Adapter |
| Calibration | Auto-calibration support |
| Compliance | JIS Z 8401 (pH), JIS K 0101 (Conductivity), ISO 5667-3, ASTM D1293, ASTM D5391, USP <645>, FDA 21 CFR Part 11 (with optional software module) |
| Connectivity | USB interface for PC connection and printer output |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-71 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | pH, mV (ORP), Ion Concentration, Conductivity, Resistivity, Salinity, Total Dissolved Solids (TDS) |
| IP Rating | IP67 |
| Display | Backlit LCD with Capacitive Touchscreen |
| Data Storage | 1,000 measurement records |
| Power Supply | AAA alkaline batteries, Ni-MH rechargeable batteries, or AC adapter |
| Compliance | JIS Z 8401 (pH), JIS K 0101 (conductivity), NIST-traceable calibration support |
| Calibration | Auto-calibration assist, 5-point pH calibration, automatic range switching & temperature compensation for conductivity, salinity/TDS/resistivity auto-conversion |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-71 |
| Instrument Type | Portable pH Meter |
| pH Range | 0–14 |
| Temperature Range | 0–100 °C |
| IP Rating | IP67 |
| Housing Material | Impact-Resistant Polycarbonate |
| Battery Life | Approx. 1000 hours |
| Data Storage | 1000 measurements |
| Compliance | GLP/GMP-ready (data traceability supported in compatible models |
| Electrode Mounting | Adjustable single-hand electrode holder with 360° rotation |
| Display | Backlit LCD (D-71 model: non-backlit) |
| Cleaning Compatibility | Alcohol, weak acids/bases, oils (chemically inert surface) |