Online Instrument
Filter
Showing 1–30 of 49 results
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OL 2030N |
| Instrument Type | Laboratory-Grade Volatile Phenol & Anionic Surfactant Analyzer |
| Sample Capacity | Anionic Surfactant – up to 55 positions |
| Sample Introduction | Rotary Disk Autosampler |
| Fluid Handling | Precision Syringe + Peristaltic Pump Hybrid Delivery |
| Extraction Protocol | Programmable Multi-Stage Chloroform Extraction & Back-Extraction (compliant with GB 7494-1987, HJ 503-2009, GB/T 39302-2020, etc.) |
| Calibration | Fully Automated Standard Preparation, Multi-Point Curve Generation, and Auto-Dilution for High-Concentration Samples |
| Waste Management | Closed-Loop Waste Collection, Activated Carbon Exhaust Scrubbing |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL 3120 |
| Instrument Type | Laboratory-Grade |
| Measurement Principle | 2-Hour Closed-Vessel Digestion Followed by Potentiometric/Colorimetric Titration |
| Measurement Range | 0–70,000 mg/L COD (with automatic dilution for over-range samples) |
| Accuracy | ≤2% RSD (vs. certified reference materials) |
| Repeatability | ≤2% RSD |
| Detection Limit | 4 mg/L COD |
| Sample Processing Time | <3 min per sample (post-digestion titration) |
| Sample Capacity | 30–100 positions (user-configurable) |
| Digestion Stations | 20 parallel positions |
| Cooling Method | Point-to-point forced-air condensation system |
| Endpoint Detection | Dual-mode (colorimetric + algorithm-assisted hue transition recognition per ISO 6060 and EPA 410.4) |
| Digestion Control | Intelligent micro-boiling temperature regulation (150–165 °C, ±0.5 °C stability) |
| Data Output | Excel/PDF export, LIMS integration (HL7/ASTM E1384 compliant), automated report generation with audit trail |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL 5012 |
| Measurement Parameters | Total Phosphorus (TP) & Total Nitrogen (TN) |
| Instrument Type | Laboratory-Based Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| TP Range | 0.04–1.2 mg/L |
| TN Range | 0.2–7 mg/L |
| Accuracy | <2% for both TP and TN |
| Detection Limit | TP: 0.01 mg/L |
| TN | 0.05 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | OL-P0103 |
| Instrument Type | Manual Portable Water Sampler |
| Sampling Method | Quantitative Sampling |
| Single Sample Volume | 500 mL |
| Sampling Volume Accuracy | ±2% |
| Sampling Depth | 0.5 m below water surface |
| Bottle Material | Borosilicate Glass (500 mL Wide-Mouth) |
| Bottle Cap | 1 cm-thick PTFE Septum with Inlet Port |
| Actuation Mechanism | Manual Pull-Chain for Septum Opening/Closing |
| Chain & Pull Cord Length | ≥3.5 m |
| Compliance | HJ/T 91–2001, HJ 970–2018, HJ 637–2018 |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1010 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | <60 s |
| Light Source | Switching Power Supply–Driven IR Emitter |
| Wavelength Selection Method | Motorized Precision Grating Drive |
| Zero Calibration | Real-time Dual-Signal Auto-Zero (Illuminated & Dark Current Compensation) |
| Extraction Solvent | Perchloroethylene (C₂Cl₄) |
| Calibration Modes | Certified Reference Standards, Multi-point Calibration Curve, Single-point Rapid Calibration |
| Compliance | Meets HJ 637–2018 (China), ASTM D7066–22 (Standard Test Method for Determination of Oil and Grease in Water by Infrared Spectrophotometry), ISO 9377-2:2000 (Water Quality — Determination of Hydrocarbon Oil Index) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | OL1010D |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2960, 2930, and 2870 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | <60 s |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL1011 |
| Instrument Type | Online |
| Measurement Principle | Infrared Spectrophotometry |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Measurement Frequency | User-Configurable |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OL1011EX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, 2870 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | OL1012 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at ~2960 cm⁻¹, ~2930 cm⁻¹, and ~2850 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | OL1020 Fully Automated Infrared Spectrophotometric Oil Analyzer |
| Instrument Category | Laboratory-Based |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L (with automatic dilution for over-range samples) |
| Detection Limit | 0.03 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | OL1020 |
| Instrument Category | Laboratory-Based |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0–50,000 mg/L |
| Detection Limit | 0.03 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Analysis Time per Sample | <5 minutes |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL1025 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry |
| Measurement Range | 0–50,000 mg/L (with automatic high-concentration dilution) |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | 10 min per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1030 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | UV Spectrophotometry (225 nm) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | 1 minute per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | OL1031 |
| Pricing | Upon Request |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1032 |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet (UV) Spectrophotometry |
| Measurement Range | 0–50 mg/L |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Measurement Frequency | Not Applicable |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL1040 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Ultraviolet Spectrophotometry |
| Measurement Range | 0–16 mg/L (with automatic dilution beyond range) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | <6 minutes per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | OL1041 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | UV Absorption Spectrophotometry (225 nm) |
| Measurement Range | 0–16 mg/L (with automatic dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Analysis Time | <6 minutes per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OL1043 |
| Instrument Category | Laboratory-Based |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–5 mg/L (with automatic dilution beyond range) |
| Detection Limit | 0.0010 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1045 |
| Instrument Type | Portable |
| Measurement Principle | UV Spectrophotometry |
| Measurement Range | 0–60 mg/L (auto-dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | <8 min per water sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL1045N |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0–16 mg/L |
| Analysis Time | <8 min per water sample |
| Compliance | HJ 970–2018 (China), GB 17378.4–2007 (Marine Monitoring) |
| Sample Volume Detection | Non-contact automatic measurement with <2% error |
| Extraction Solvent | n-Hexane |
| Oil Separation Method | Magnesium Silicate Adsorption Column |
| Integrated Functional Modules | Sampling, Liquid–Liquid Extraction, Phase Separation, Reagent Delivery, UV Absorbance Measurement |
| Remote Control | Web-based interface compatible with smartphones and tablets |
| Enclosure Material | High-strength engineering plastic |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OL1046 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–5 mg/L |
| Detection Limit | 0.0010 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Cycle Time | 9 minutes |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OL1050 |
| Detection Principle | Infrared Absorption (FTIR-compatible broadband IR photometry) |
| Instrument Class | Laboratory-Based Fixed-Position Analyzer |
| Primary Application Sector | Petrochemical Industry |
| Compliance Basis | Designed to support EPA Method 27 / ISO 12103-1 alignment for airborne oil aerosol quantification |
| Measurement Range | Configurable via auto-dilution (standard range: 0.1–100 mg/m³, extendable to 500 mg/m³ with intelligent over-range dilution) |
| Sample Introduction | Filter Cartridge (glass fiber or quartz) or Sleeve-Type Sampling Probe |
| Extraction Solvent | Tetrachloroethylene (C₂Cl₄) |
| Extraction Method | High-Efficiency Ultrasonic Assisted Extraction |
| Phase Separation | Automatic Density-Based Liquid-Liquid Separation (C₂Cl₄/H₂O) |
| Calibration Modes | Certified Reference Material (CRM)-based calibration, Multi-Point Standard Curve, Single-Point Rapid Calibration |
| Reagent Handling | Fully Automated Dispensing, Recovery, and Activated Carbon–Filtered Exhaust Management |
| Data Interface | Embedded Touchscreen PC + Remote Web API & Mobile App (iOS/Android) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging (user authentication, electronic signature, change history) |
| Brand | Online Instrument |
|---|---|
| Model | OL1056 |
| Origin | Shanghai, China |
| Portability | Portable |
| Application Field | Food Service Industry (Commercial Kitchen Exhaust Monitoring) |
| Compliance Basis | HJ 646–2013, HJ 647–2013, HJ 1077–2019 (Chinese EPA Standards for Oil Fume Emission Monitoring) |
| Sample Handling | Fully Automated Reagent Dispensing, Dual-Stage Ultrasonic Extraction, Cuvette Cleaning, Volumetric Finalization, Photometric Quantification at 530 nm |
| Data Output | Excel, PDF, LIMS-Compatible Export |
| Remote Operation | Web-Based Dashboard & Mobile App Support |
| Enclosure Material | Reinforced Engineering Thermoplastic (IP54 Rated) |
| Brand | Online Instrument |
|---|---|
| Model | OL1061 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption (C–H Stretching Band at ~2930 cm⁻¹) |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Extraction Solvent | Perchloroethylene (C₂Cl₄) |
| Extraction Ratio | Adjustable from 1:1 to 1:50 (solvent:sample) |
| Sampling Depth | Up to 0.5 m submersible |
| Power Supply | Integrated rechargeable battery (4 h continuous operation) |
| Data Interval | Programmable from 1–999 s |
| Interface | Touchscreen industrial PC |
| Compliance | Designed to support EPA Method 1664A, ISO 9377-2, and GB/T 16488–1996 equivalency |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1071 |
| Instrument Type | Portable |
| Detection Principle | UV Absorption Spectrophotometry (225 nm) with Continuous Flow Liquid-Liquid Extraction |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL1120N |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Infrared Spectrophotometry (ASTM D7066, ISO 9377-2, HJ 637–2018) |
| Sample Capacity | 24-position carousel (expandable) |
| Extraction Solvent | Tetrachloroethylene (C₂Cl₄) |
| Oil Classification | Petroleum Hydrocarbons & Animal/Vegetable Oils |
| Separation Method | Triple-phase separation via extraction tube, aqueous barrier membrane, and phase separation column |
| Calibration Options | Certified reference standards, multi-point calibration curve, single-point rapid calibration |
| Reagent Recovery | Automated solvent–water immiscible phase separation |
| Remote Access | Web-based GUI + mobile-responsive interface with real-time status monitoring and audit-trail-enabled command logging |
| Sealing Mechanism | Adaptive elastic dynamic pressure seal (no rotary lid wear) |
| Fluid Handling | High-precision 3-axis robotic arm + solenoid-driven micro-pumps (MTBF ≥ 4×10⁶ cycles) |
| Mixing | Turbulent vortex injection + active flow agitation |
| Cleaning Protocol | Continuous “live-water” rinse between samples |
| Detection Range | Compliant with HJ 637–2018 quantification limits (0.01–100 mg/L for petroleum hydrocarbons |
| Data Compliance | 21 CFR Part 11–ready electronic records with user-level access control, timestamped audit trail, and GLP/GMP-aligned metadata tagging |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1171 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry (225 nm) with Continuous-Flow Liquid-Liquid Extraction |
| Measurement Range | 0–16 mg/L (with automatic on-board dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Measurement Frequency | User-Configurable (1–12 measurements/hour typical) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | OL2010 |
| Instrument Type | Laboratory-Based Water Quality Analyzer |
| Analyte | Anionic Surfactants (e.g., LAS, SDS, AES) |
| Compliance Standards | GB 7494–1987, GB/T 5750.4–2023, GB 17378.4–2007, GB 8538–2023, GB/T 39302–2020 |
| Sample Capacity | 25 / 50 / 55 positions (field-upgradable) |
| Extraction Method | Multi-stage chloroform-based liquid–liquid extraction and back-extraction |
| Recovery Rate | ≥95% |
| Automation Level | Fully Automated (reagent dispensing, extraction, phase separation, sample introduction, calibration, waste handling) |
| Data Interface | LIMS-compatible (ASTM E1467-compliant data export, audit trail ready) |
| Safety System | Closed-loop reagent handling, activated carbon exhaust treatment, automated hazardous waste containment |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2010N |
| Instrument Type | Benchtop |
| Ion Detection Capability | Multi-ion |
| Measurement Range | 0.05–2 mg/L |
| Limit of Detection (LOD) | 0.01 mg/L |
| Response Time | Real-time |
| Measurement Accuracy | ±2% |
| Operating Temperature Range | 5–35 °C |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OL2020N |
| Instrument Type | Laboratory-Grade Volatile Phenol Analyzer |
| Sample Capacity | 10 / 22 / 25 positions (field-upgradable) |
| Automation Level | Fully Automated (distillation, reagent addition, liquid transfer, extraction, spectrophotometric measurement) |
| Calibration | Auto-standard preparation & multi-point calibration curve generation |
| Reagent Management | Real-time monitoring, low-reagent alert, closed-loop waste & fume collection |
| Data Interface | LIMS-compatible, remote monitoring via web browser or mobile application |
| Compliance | Designed per HJ 503–2009 and HJ 998–2018 (China EPA standards) |
| Safety Architecture | Fully enclosed operation with integrated fume absorption system |
