Sutter
Filter
Showing 1–30 of 31 results
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BV-10 |
| Pricing | Upon Request |
| Heating Elements | Platinum-Iridium Wire & Tin-Lead Alloy Wire |
| Minimum Tip Diameter Achievable | < 0.3 µm |
| Control | Digital Precision Control of Heat and Tension (3 Independent Channels) |
| Construction | Corrosion-Resistant Housing |
| Footprint | Compact Benchtop Design |
| Primary Application | Patch-Clamp Electrophysiology, Intracellular Microinjection, Single-Cell Physiology |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Heating Elements | Platinum/Iridium wire and Tin-Lead alloy wire |
| Precision Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscope Integration | Dual-objective stereo microscope (low- and high-magnification objectives for coating and polishing) |
| Construction | Corrosion-resistant chassis |
| Footprint | Compact design for benchtop integration in electrophysiology rigs |
| Application Focus | Patch-clamp electrode conditioning, intracellular microinjection, sharp electrode preparation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Instrument Type | Microelectrode Processing System for Electrophysiology |
| Heating Elements | Pt/Ir wire and Sn-Pb alloy wire |
| Tip Diameter Capability | < 0.3 µm |
| Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscopy | Integrated dual-magnification optical system (low- and high-power objectives) |
| Compliance | Designed for GLP-compliant electrophysiology lab workflows |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | dPATCH |
| Pricing | Upon Request |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | EG-400 |
| Motor Speed | 50–2000 rpm |
| Electrode Manipulator Travel | 47 mm (vertical) |
| Microscope Travel | X: 7 mm, Y: 30 mm, Z: 8 mm |
| Magnification | 30× (10× eyepiece × 3× objective) |
| Capillary Outer Diameter Range | 1.0–1.5 mm |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Product Type | Replacement Filament Heating Elements |
| Compatible Models | P-1000, P-97, P-87, P80PC, P80C, PC-84, P-77B, P-30, P-2000, P-77A |
| Filament Types | Box (square), Trough (rectangular), Loop, Custom Pt/Ir, Nichrome |
| Dimensions Range | 1.5–4.5 mm width |
| Material Options | Kanthal A1, Nichrome, Platinum/Iridium alloy |
| Packaging | Minimum order quantity = 4 filaments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | IPA |
| Type | Integrated Electrophysiology Amplifier System with Built-in ADC/DAC |
| Compliance | Designed for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings |
| Software | SutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | M3301 |
| Weight | 550 g |
| Transport Weight | 1.4 kg |
| X-Axis Travel | 10 mm & 37 mm (dual-range configuration) |
| Y-Axis Travel | 25 mm |
| Z-Axis Travel | 25 mm |
| X-Axis Resolution | 0.01 mm (fine) / 0.1 mm (coarse) |
| Y/Z-Axis Resolution | 0.1 mm |
| Mounting Interface | Standard 12 mm clamp & Electrode Holder M3301EH |
| Handedness | Left- and Right-Hand Configurations Available |
| Guidance System | Precision V-groove rails with roller bearings |
| Structural Material | Stainless steel moving components |
| Optical Compatibility | Designed for integration with upright/inverted microscopes up to 250× magnification |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MF-900 |
| Heating Stage Travel (X/Y/Z) | 14 mm / 14 mm / 14 mm |
| Micropipette Manipulator Travel (X/Z) | 12 mm / 28 mm |
| Microscope Stage Travel (X/Y/Z) | ~7 mm / 30 mm / ~8 mm |
| Microscope Magnification | 50× / 100× (10× eyepiece, 5× & 10× objectives) |
| Capillary Outer Diameter | 1.0 mm |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MF2 Microforge |
| Heating Manipulator Travel | X/Y/Z ±14 mm |
| Pipette Manipulator Travel | X/Y/Z ±12 mm |
| Microscope Stage Travel | X ±7 mm, Y ±30 mm, Z ±8 mm |
| Max Bending Angle | ≤90° |
| Compatible Capillary OD | 1.0–1.5 mm |
| Magnification Options | 50×, 75×, 100×, 525× (via interchangeable objectives/eyepieces) |
| Heating Power Control | Adjustable rotary knob |
| Footswitch | Integrated for hands-free heating activation |
| Illumination | Continuously variable brightness LED ring light |
| Input Power | AC 220 V ±5% / 240 V ±5%, 50/60 Hz |
| Power Consumption | 35 W |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-aligned lab environments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MM-33 |
| Control Type | Manual |
| Coarse Adjustment Range (X/Y/Z) | 37 mm / 20 mm / 20 mm |
| Coarse Resolution | 0.1 mm per axis |
| Fine Adjustment Range (X) | 10 mm |
| Fine Resolution | 0.01 mm |
| Rotational Base | Lockable, Dual-Axis (Horizontal & Vertical) |
| Mounting Compatibility | Magnetic base, standard dovetail or clamp-style stage adapters |
| Intended Use | Electrophysiology, patch-clamp, microinjection, and extracellular stimulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MN-151 Micromanipulator |
| Pricing | Available Upon Request |
| Material | Lightweight Aluminum Alloy |
| Mounting | Side-mount compatible with standard microscope stages |
| Operation | Ambidextrous (left- or right-hand configurable) |
| Coarse Motion Range (X/Y/Z) | 25 mm / 20 mm / 25 mm |
| Fine Motion Range (X) | 8 mm (MN-152 adds X-axis fine adjustment) |
| Z-axis Fine Control | Linear push-button actuator with 250 µm full stroke, 5 µm minimum incremental displacement |
| Dimensions (W×D×H) | 121 × 36 × 145 mm |
| Weight | 330 g |
| Compatible Accessories | B-8B Ball Joint, P-1A Height Adjustment Plate, H-7 Pipette Holder, Allen Wrench Set |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-285 |
| Drive Type | Motorized (DC stepper motor) |
| Axes | 4-axis (X, Y, Z, Oblique) |
| Travel Range | 25 mm per axis |
| Minimum Step Resolution | 0.04 µm (high-res mode) / 0.2 µm (low-res mode) |
| Maximum Speed | 2.9 mm/sec |
| Drift | ≤10 nm/hr at 24°C |
| Position Display | LCD with real-time X/Y/Z coordinate readout (µm resolution) |
| Control Modes | Continuous motion and discrete step motion |
| Programmability | RS-232 and USB interface for external computer control |
| Homing Function | Yes (user-defined HOME position) |
| Microscope Compatibility | Universal mounting (standard dovetail and adapter plates) |
| Compliance | Designed for GLP-compliant electrophysiology workflows |
| Software Integration | Compatible with SutterPatch, PatchMaster, and third-party acquisition platforms (e.g., Axon pCLAMP, HEKA PatchMaster) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP-85 |
| Axes | XYZ motorized with manual coarse/fine/ultra-fine adjustment |
| X-axis rotation | 0–45° in 15° increments |
| Coarse resolution (XYZ) | 0.1 mm |
| Fine resolution (X-axis) | 0.01 mm |
| Ultra-fine resolution (X-axis) | 0.2 µm |
| Dimensions | 25 mm × 25 mm × 25 mm |
| Compliance | Designed for electrophysiology, patch-clamp, and intracellular injection workflows under GLP-aligned laboratory practices |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP225 |
| Movement Axes | X, Y, Z, and Oblique (4-axis) |
| Resolution | 0.0625–2.0 µm/step (selectable) |
| Maximum Travel | 25.4 mm per axis |
| Minimum Step Size | 0.04 µm (high-resolution mode) |
| Maximum Speed | ≥ 2.9 mm/sec |
| Thermal Drift Stability | ≤ 10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw Actuation |
| Position Display | Real-time LCD readout in micrometers |
| Return-to-Home Function | Yes |
| Motion Modes | Continuous, Stepped, Joystick, FSR Piezo Assist, ROE200 Rotary Encoder Control |
| Programmability | Multi-step motion sequences supported |
| Compatibility | Universal mounting for upright & inverted microscopes |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows requiring traceable positioning and audit-ready operation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP85 / MP285 / MP-33 |
| Type | Electrochemical Sample Manipulator |
| Axes | 3–4 axis (manual or motorized) |
| Positioning Resolution | Down to 62.5 nm (MP-285/MP-225), 0.2 µm (MP-85 ultra-fine), 0.01 mm (MP-33 fine), 0.1 mm (coarse) |
| Drift | <10 nm/h (MP-285, 24°C), <1 µm/h (MPC-325-2/MPC-385-2) |
| Travel Range | Up to 25 mm (X/Y/Z/oblique), 1 inch (MP-285), 37 × 20 × 20 mm (MP-33 coarse) |
| Control Interface | RS-232 serial, software-driven (XenoWorks™ compatible) |
| Compliance | Designed for GLP/GMP-aligned electrophysiology and electrochemical microelectrode positioning |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-200 / MPC-385 / MPC-325 |
| Drive Type | Motorized (DC servo) |
| Position Resolution | ≤ 10 nm (closed-loop) |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 25 mm (standard) |
| Repeatability | ±0.1 µm |
| Max Load Capacity | 250 g |
| Compatibility | Standard micropipette holders (e.g., Sutter MO-103, MO-203), compatible with upright & inverted microscopes |
| Interface | Analog voltage input (±10 V), RS-232, optional USB-to-serial adapter |
| Operating Temperature | 15–30 °C |
| Humidity | 20–80% RH (non-condensing) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-225 |
| Component Category | Optical Instrument Component |
| Actuation | Stepper Motor–Driven |
| Axes | 3 (X/Y/Z) + Optional 4th Diagonal Axis via ROE-225 |
| Travel Range per Axis | 25 mm |
| Motion Resolution | Adjustable via Dual-Range Position Knobs (Coarse/Fine, 10 µm fine increment) |
| Bearing System | Preloaded Ball-Bearing Slides |
| Compatibility | Mounting Interfaces for MP-285 Pipette Holders and Probes |
| Controller | Integrated Self-Diagnosing MP-225 Controller with ROE-225 Human-Machine Interface |
| Configuration | Factory-Assembled Right- or Left-Handed |
| Mounting | Standard ¼-20 or 10-32 threaded holes on Square Base Plate |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC-385-2 |
| Controller | MPC-200 |
| Manipulators | (2) MP-285 |
| Rotary Encoder Module | ROE-200 |
| Axes | X, Y, Z, Oblique |
| Travel Range | 25 mm per axis |
| Max Speed | 5 mm/s |
| Resolution | 0.04 µm (high), 0.2 µm (low) |
| Drift | ≤10 nm/hr at 24°C |
| Motion Modes | Continuous & Step |
| Programmable | Yes, via RS-232/USB |
| Homing Function | Yes |
| Compatibility | Universal microscope mounting |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MPC325-2 |
| Axes | X, Y, Z, and Oblique (4-axis) |
| Travel Range | 25.4 mm per axis |
| Step Resolution | 0.0625–2.0 µm |
| Maximum Speed | 3 mm/s |
| Thermal Drift | ≤10 nm/h at 24°C |
| Drive Mechanism | Precision Lead-Screw |
| Position Display | LCD (µm resolution) |
| Control Modes | ROE200 Rotary Encoder, FSR Piezo Controller, Joystick |
| Repeatability Function | Yes |
| Compatibility | Universal Microscope Mounting |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-1000 |
| Dimensions | 53 cm × 36 cm × 30 cm |
| Weight | 18.59 kg |
| Power Supply | 115/230 V, 50/60 Hz |
| Certification | CE |
| Included | User Manual, Sutter Pipette Cookbook (hard copy), FB255B filament, glass sample kit |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-2000 |
| Heating Source | CO₂ Laser |
| Max Capillary OD | Glass 1.5 mm / Quartz 1.8 mm |
| Min Capillary OD | Glass 0.125 mm / Quartz 0.6 mm |
| Tip Diameter Range | 5–10 µm (reproducible down to ≤0.03 µm) |
| Programmable Protocols | 100 |
| Laser Lifetime | >10 years |
| Control System | Microprocessor-based with write-protected timestamp logging |
| Symmetry | Dual-symmetric pull per cycle |
| Compliance | GLP-compliant audit trail capability (timestamped protocol execution logs) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-2000 |
| Dimensions | 76 cm × 36 cm × 33.5 cm |
| Weight | 36 kg |
| Power Supply | 115/230 V, 50/60 Hz |
| Laser Type | CO₂ |
| Max. Glass OD | 1.5 mm (quartz), 1.8 mm (borosilicate) |
| Programmable Protocols | 100 × 8-step |
| Tip Diameter Reproducibility | < 30 nm |
| Laser Lifetime | > 10 years |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Dual-Pipette Capability | Yes |
| Tip Diameter Range | Down to 0.3 µm |
| Pipette Length Range | 10–15 mm |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Adjustment | Integrated Micrometer for Repeatable Pull Length |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| EMI Suppression | Built-in RFI Filtering |
| Voltage/Frequency Options | Dual (115 V / 60 Hz & 230 V / 50 Hz) |
| Clamp Material | Rubber-Padded Stainless Steel |
| Construction | Corrosion-Resistant Components |
| Application Focus | Patch-Clamp Electrophysiology, Intracellular Recording, Microinjection |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Mechanism | Micrometer-Based Pull Length Reproducibility |
| Electrode Tip Diameter | Down to <0.3 µm |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| Dual-Step Heating Mode | Yes |
| RFI Filtering | Integrated |
| Mounting Base | Rubber-Pad Clamping System |
| Construction Materials | Corrosion-Resistant Alloys and Ceramics |
| Voltage/Frequency Options | Dual (115 V / 230 V |
| Application Domain | Intracellular Electrophysiology, Patch-Clamp Recording, Microinjection, Single-Cell Manipulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal programmable micropipette puller for electrophysiology and microinjection |
| Heating mechanism | Resistive filament (tungsten/platinum coil) with precision-controlled current |
| Pulling force | Pneumatically actuated, programmable pressure and release timing |
| Control system | Embedded microprocessor with 100-program non-volatile memory |
| Display | Vacuum fluorescent display (VFD) |
| Filament and solenoid power supply | Constant-current |
| Electrode symmetry | Dual symmetric pipettes per pull |
| Tip diameter reproducibility | ≤0.06 µm (SEM-verified), routinely <0.1 µm |
| Cooling mode | Optional external airflow for large-diameter/multi-barrel glass |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P97 |
| Instrument Type | Electrochemical Micropipette Fabrication System |
| Heating Element | Dual-Loop Resistive Wire (NiChrome or Platinum) |
| Control Architecture | Embedded Microprocessor with Non-Volatile Program Memory |
| Max. Program Storage | 100 Protocols |
| Display | Vacuum Fluorescent Display (VFD), Omnidirectional View |
| Environmental Control | Integrated Humidity-Stabilized Chamber |
| Cooling Options | Pneumatic Blast Cooling (Selectable Mode) |
| Glass Compatibility | Single- and Multi-Barrel Capillaries (OD up to 2.0 mm) |
| Tip Diameter Resolution | Sub-100 nm (Typical for Borosilicate & Aluminosilicate Glass) |
| Compliance | Designed for GLP/GMP-Adjacent Electrophysiology Labs |
| Software Features | Date/Time-Stamped Protocol Logging, Write-Protected Program Mode, Atmospheric Pressure Compensation Parameter |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | V3402 |
| Power Supply | 6 × AA batteries |
| Memory Capacity | 99 data sets |
| Alarm | Visual and audible, user-adjustable |
| Optional Accessories | Infrared printer (Model 8411), AC chargers (Model 1611: 105–125 V |
| Model 1612 | 208–252 V) |
| Intended Use | Veterinary patient monitoring across species and environments |
| Compliance | Designed for use in surgical suites, preoperative holding areas, field settings, and mobile clinics |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XenoWorks™ |
| Pricing | Available Upon Request |