| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GSL-1800X |
| Pricing | Upon Request |
| Heating Element | Kanthal Super-1900 MoSi₂ Rods |
| Max Temperature | 1800 °C (≤2 h), Continuous at 1750 °C |
| Heating Zone Length | 457 mm |
| Uniform Zone Length | 150 mm |
| Tube Dimensions | Ø60 mm OD × Ø54 mm ID × 1000 mm L |
| Insulation | High-Purity Al₂O₃ Fiber + 10 mm ZrO₂ Liner (Ref. Temp: 2300 °C) |
| Cooling | Dual-Layer Shell with Forced-Air System |
| Temperature Control | 30-Stage PID Programmable Controller |
| Accuracy | ±1 °C |
| Thermocouple | Type B (Pt/Rh) |
| Vacuum Performance | 10⁻² torr (Mechanical Pump), 10⁻⁵ torr (Turbomolecular Pump) |
| Power Supply | AC 220 V, 50/60 Hz, 5 kW (40 A Circuit Required) |
| Dimensions (W×D×H) | 590 × 490 × 760 mm |
| Weight | 150 kg |
| Safety Certification | CE Marked |
| Surface Temp | <55 °C Under Operation |
| Ambient Requirements | Altitude ≤1000 m, Ambient Temp 25 °C ±15 °C, RH 55% ±10% |
| Ventilation | Mandatory |
| Workbench Spec | ≥1200 × 600 × 700 mm, Load Capacity ≥300 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-1800X-S |
| Power Supply | AC 220 V, 50/60 Hz, 2.5 kW (30 A circuit breaker required) |
| Maximum Temperature | 1800 °C (<4 h), Continuous Operating Temperature: 1750 °C |
| Heating Zone Length | 300 mm |
| Uniform Temperature Zone | 80 mm |
| Heating Rate | 5 °C/min below 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Thermocouple Type | Type B |
| Vacuum Performance | 10⁻² torr (with mechanical pump) |
| Tube Dimensions | Al₂O₃, OD 60 mm, ID 54 mm, L 790 mm |
| Furnace Dimensions (W×D×H) | 590 × 490 × 760 mm |
| Net Weight | 150 kg |
| Insulation | High-purity alumina fiber with 10 mm ZrO₂ liner (refractoriness: 2300 °C) |
| Heating Element | Kanthal Super-1900 MoSi₂ rods (rated to 1900 °C) |
| Cooling | Dual-layer shell with forced-air cooling (surface temperature <55 °C) |
| Controller | PID-based 30-segment programmable temperature profile |
| Certification | CE compliant |
| Ambient Requirements | Altitude ≤1000 m |
| Required Infrastructure | Grounded AC power only |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GSL-1800X-ZF-AM |
| Pricing | Upon Request |
| Vacuum Chamber | Ø300 mm × 360 mm (stainless steel, electropolished interior) |
| Base Pressure | 8.0 × 10⁻⁵ Pa |
| Operating Vacuum Range | 8.0 × 10⁻⁴ Pa |
| Leak Rate | 6.7 × 10⁻⁸ Pa·L/s |
| Evaporation Power Supply | AC 0–8 V, up to 200 A (max. 1.6 kW) |
| Substrate Heater | RT–500 °C, PID-controlled |
| Film Thickness Resolution (Al) | 0.1 Å |
| Water Cooling Requirement | 15 L/min |
| Substrate Holder Diameter | Ø120 mm |
| Source-to-Substrate Distance | 140–200 mm |
| Observation Port | Ø100 mm quartz window with metal-sealed O-ring |
| Pumping Configuration | 600 L/s turbo-molecular pump + mechanical roughing pump |
| Vacuum Valves | 1 × KF40 bypass valve, 1 × CF150 gate valve, 1 × KF16 flange (for resistance gauge), 6 × CF35 flanges (including for ion gauge, 2-pin electrode, quartz crystal microbalance) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | GSL-1800X-ZF2 |
| Vacuum Base Pressure | 3.0×10⁻⁴ torr (with turbomolecular pump) |
| Maximum Evaporation Power | 1000 W (5 V / 200 A) |
| Sample Stage Diameter | Ø120 mm, Motorized Rotation |
| Evaporation Source Configuration | Dual Resistive Sources (Tungsten Boat + Tungsten Wire Basket) |
| Control Interface | 7-inch TFT Touchscreen (Graphical UI) |
| Film Thickness Resolution | 0.1 Å (standard), 0.01 Å (optional QCM upgrade) |
| Power Supply | AC 220 V, 50 Hz, 1500 W Total |
| Dimensions (W×D×H) | 440 × 240 × 260 mm |
| Weight | ~47 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | GSL-1800X-ZF2 |
| Power Supply | AC 220 V, 50 Hz |
| Maximum Operating Temperature | 1800 °C (via tungsten or molybdenum boat) |
| Base Pressure | ≤5 × 10⁻⁴ Pa (with optional turbomolecular pump) |
| Chamber Diameter | Ø300 mm |
| Chamber Height | 360 mm |
| Substrate Holder | Ø50 mm, rotary and optional heated (up to 500 °C) |
| Evaporation Sources | Dual resistive-heating boats (W/Mo) + optional e-beam crucible |
| Vacuum Interface | KF25 flanges |
| Compliance | CE certified |
| Dimensions (W×D×H) | 360 mm × 350 mm × 360 mm |
| Weight | 50 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-1800X-ZF4 |
| Vacuum Chamber | Ø300 mm × 400 mm (stainless steel, electropolished interior) |
| Base Pressure | ≤8.0×10⁻⁵ Pa |
| Ultimate Vacuum | ≤8.0×10⁻⁴ Pa |
| Leak Rate | ≤6.7×10⁻⁸ Pa·L/s |
| Evaporation Sources | 4 independent tungsten heating boats |
| Substrate Heater | 0–500 °C, PID-controlled |
| Film Thickness Resolution (Al) | 0.1 Å |
| Cooling Water Flow | 15 L/min |
| Power Input | AC 220 V, 50/60 Hz, <2.16 kW (excl. pumps) |
| Evaporation Output | 0–8 V AC, up to 200 A, max. 1.6 kW |
| Substrate Stage Diameter | Ø120 mm |
| Source-to-Substrate Distance | 140–200 mm |
| Dimensions (W×D×H) | 900×1100×1800 mm |
| Weight | 230 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-1800X-ZF4 |
| Vacuum Chamber | Ø300 mm × 400 mm (stainless steel, electropolished interior) |
| Base Pressure | ≤8.0×10⁻⁵ Pa |
| Ultimate Vacuum | ≤8.0×10⁻⁴ Pa |
| Leak Rate | ≤6.7×10⁻⁸ Pa·L/s |
| Evaporation Source | 4 independent tungsten boat heaters |
| Max Evaporation Current | 200 A |
| Evaporation Voltage Range | AC 0–8 V (continuously adjustable) |
| Sample Stage | Ø120 mm, top-mounted, heated (RT–500 °C, PID-controlled) |
| Substrate-to-Source Distance | 140–200 mm |
| Film Thickness Resolution (Al) | 0.1 Å |
| Cooling Water Flow | 15 L/min |
| Power Input | AC 220 V, 50/60 Hz, <2.16 kW (excl. pumps) |
| Dimensions (W×D×H) | 900 × 1100 × 1800 mm |
| Weight | 230 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-1800X-ZF4 |
| Vacuum Chamber | Ø300 mm × 400 mm (stainless steel, electropolished interior) |
| Base Pressure | ≤8.0×10⁻⁵ Pa |
| Ultimate Vacuum | ≤8.0×10⁻⁴ Pa |
| Leak Rate | ≤6.7×10⁻⁸ Pa·L/s |
| Evaporation Sources | 4 independent tungsten boat heaters (water-cooled base with 5 water-cooled electrodes) |
| Substrate Heater | Temperature-controlled, RT–500 °C |
| Film Thickness Resolution (Al) | 0.1 Å |
| Substrate-to-Source Distance | 140–200 mm |
| Viewing Port | Ø100 mm fused quartz window with metal-sealed O-ring |
| Pumping System | 600 L/s turbo-molecular pump + KF40 bypass valve + CF150 gate valve |
| Electrical Input | AC 220 V, 50/60 Hz, <2.16 kW (excl. pumps) |
| Evaporation Power Supply | 0–8 V AC, up to 200 A, max 1.6 kW |
| Cooling Water Flow | 15 L/min (deionized or purified water) |
| Dimensions (W×D×H) | 900×1100×1800 mm |
| Weight | 230 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-2Z |
| Pricing | Available Upon Request |
| Power Supply | 185–245 VAC, 50 Hz |
| Max. Output Power | 18 W |
| Flow Control Range | Channel 1: 1–199 SCCM |
| Channel 2 | 1–499 SCCM |
| Max. Operating Pressure | 3 MPa (3 × 10⁶ Pa) |
| Accuracy | ±1% FS |
| Linearity | ±0.5–1.5% FS |
| Repeatability | ±0.2% FS |
| Response Time | Gas Dynamic: 1–4 s |
| Electrical | ≤10 s |
| Needle Valve Material | 316 Stainless Steel |
| Operating Pressure Differential | 0.1–0.5 MPa |
| Vacuum/Pressure Gauge Range | –0.1 to +0.15 MPa (0.01 MPa per division) |
| Mixing Chamber Dimensions | Ø80 mm × 120 mm |
| Shut-off Valve | 1/4″ BSP, 316 Stainless Steel |
| Ambient Operating Temperature | 5–45 °C |
| Overall Dimensions (W × D × H) | 600 × 600 × 650 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-300-PLD |
| Pricing | Upon Request |
| Ultimate Vacuum | ≤6.67×10⁻⁵ Pa (after bake-out) |
| Leak Rate | ≤5.0×10⁻⁷ Pa·L/s |
| Pump-Down Time to 5×10⁻³ Pa | ≤20 min (after N₂ purge) |
| Substrate Heater Max Temp | 800 °C ±1 °C |
| Substrate Rotation Speed | 5–60 rpm |
| Target-to-Substrate Distance | 30–90 mm |
| Target Mounting Capacity | 4 × φ1″ targets |
| Target Rotation Speed | 5–60 rpm |
| Vacuum Chamber | Ø300 mm spherical stainless steel chamber with RF150 front-loading door, RF63 UV quartz viewport (laser input), RF63 IR quartz viewport (optional pyrometry), and RF63 optical observation window |
| Cooling | Integrated closed-loop chiller (T < 25 °C, P = 0.25–0.4 MPa, flow ≥12 L/min, deionized water) |
| Power Supply | AC 380 V, 50 Hz, ≥10 kW, voltage fluctuation < ±6%, grounding resistance < 2 Ω |
| Process Gases | High-purity N₂ or Ar (≥99.99%) via dual-ferrule 10 mm tubing interface |
| Floor Space Requirement | 2000 mm × 2000 mm |
| Weight Load Capacity | ≥1000 kg |
| Exhaust | Mandatory external venting duct for ablation byproducts |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-3F |
| Pricing | Upon Request |
| Gas Channels | 3 (customizable) |
| Flow Control Method | Precision Float Flowmeters |
| Standard Flow Ranges | 10–100 mL/min, 16–160 mL/min, 25–250 mL/min |
| Tubing | Stainless Steel, OD 6 mm × ID 4 mm |
| Fitting Interface | 1/4″ (6.35 mm) Compression |
| Shut-off Valves | 1/4″ (6.35 mm) High-Pressure Manual Valves |
| Mixing Chamber | Ø80 mm × 140 mm Cylindrical Stainless Steel Tank |
| Pressure Gauge | Dual-Scale Vacuum/Pressure Gauge, –0.1 to +0.15 MPa, 0.01 MPa per division |
| Operating Environment | 5–45 °C, Compatible with High-Purity Gases |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-3Z |
| Pricing | Contact for Quotation |
| Power Supply | 185–245 V AC, 50 Hz |
| Max. Output Power | 18 W |
| Flow Control Ranges | MFC #1: 0–100 SCCM |
| MFC #2 | 1–199 SCCM |
| MFC #3 | 1–499 SCCM |
| Accuracy | ±1% FS |
| Linearity | ±0.5–1.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (Gas) | 1–4 s |
| Response Time (Electrical) | ≤10 s |
| Needle Valve Material | 316 Stainless Steel |
| Operating Pressure Differential | 0.1–0.5 MPa |
| Vacuum/Pressure Gauge Range | −0.1 to +0.15 MPa (0.01 MPa per division) |
| Mixing Chamber Dimensions | Ø80 mm × 120 mm |
| Shut-off Valves | 1/4″ BSP, 316 stainless steel |
| Ambient Operating Temperature | 5–45 °C |
| Overall Dimensions (W×D×H) | 600 × 600 × 650 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-450-PLD |
| Pricing | Upon Request |
| Ultimate Vacuum | ≤6.67×10⁻⁵ Pa (after bake-out) |
| Leak Rate | ≤5.0×10⁻⁷ Pa·L/s |
| Pump-down Time | ≤20 min to 5×10⁻³ Pa after N₂ purge |
| Chamber Diameter | Ø450 mm |
| Base Pressure Recovery | Achieves 5×10⁻³ Pa within 20 min after brief atmospheric exposure and dry N₂ backfill |
| Substrate Holder | Accommodates Ø2″ wafers with shutter |
| Target Assembly | 4-position rotating turret (Ø1″ or Ø2″ targets) |
| Optical Ports | One RF100 UV-grade fused silica viewport (for laser beam delivery), one RF100 IR-grade fused silica viewport (optional, for pyrometric temperature monitoring), one RF100 standard optical glass viewport (visual observation) |
| Cooling | Integrated closed-loop chiller |
| Power Supply | AC 380 V, 50 Hz, ≥10 kW, voltage fluctuation <±6%, grounding resistance <2 Ω |
| Process Gases | High-purity N₂ or Ar (≥99.99%) |
| Ventilation | Mandatory external exhaust ducting for ablation byproducts |
| Footprint | 1800 mm × 1000 mm × 1600 mm (W×D×H) |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-4Z |
| Pricing | Available Upon Request |
| Power Supply | 185–245 VAC, 50 Hz |
| Max. Output Power | 18 W |
| Flow Control Ranges | MFC1: 0–100 SCCM |
| MFC2 | 1–199 SCCM |
| MFC3 | 1–199 SCCM |
| MFC4 | 1–499 SCCM |
| Max. Operating Pressure | 3 MPa |
| Accuracy | ±1% FS |
| Linearity | ±0.5–1.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (Gas) | 1–4 s |
| Response Time (Electrical) | ≤10 s |
| Needle Valves | 316 Stainless Steel |
| Operating Pressure Drop Range | 0.1–0.5 MPa |
| Vacuum/Pressure Gauge Range | –0.1 to +0.15 MPa (0.01 MPa/division) |
| Mixing Chamber | Ø80 mm × 120 mm |
| Shut-off Valves | 1/4″ BSP, 316 SS |
| Ambient Operating Temperature | 5–45 °C |
| Dimensions (W×D×H) | 600 × 600 × 650 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-CKJS-450-B1 |
| Pricing | Available Upon Request |
| Main Chamber Dimensions | Ø450 × 355 mm cylindrical vacuum chamber |
| Base Vacuum | ≤5 × 10⁻⁵ Pa |
| Magnetron Targets | 3 × permanent-magnet RF/DC-compatible sputtering targets (Ø2″) |
| Target-to-Substrate Distance | 90–110 mm (adjustable) |
| Co-sputtering Geometry | Tri-target angular convergence toward sample center (40–80 mm focal distance) |
| Substrate Heating | Up to 600 °C ±1 °C (interchangeable with water-cooled stage) |
| Substrate Size | Ø25.4 mm (1″) |
| Substrate Rotation | Continuous, 5–15 rpm |
| Substrate Bias | Adjustable DC negative bias up to –200 V |
| Sample Holder Configuration | 6-position planetary rotation stage |
| Cooling | Integrated closed-loop chiller (deionized water or purified water) |
| Gas Supply | High-purity Ar/N₂ (≥99.99%) |
| Power Input | AC 380 V, 50 Hz, grounded |
| Ambient Requirements | Altitude <1000 m |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | GSL-CKJS-560-B2 |
| Pricing | Upon Request |
| Main Chamber Dimensions | Ø560 × 355 mm (Pear-shaped Vacuum Chamber) |
| Base Pressure | 5 × 10⁻⁶ Pa |
| Load-lock Chamber Dimensions | Ø255 × 430 mm |
| Load-lock Base Pressure | 5 × 10⁻⁴ Pa |
| Magnetron Targets | 5 × Ø2″ Permanent Magnet Targets |
| Sputtering Modes | DC & RF Compatible per Target (1 Target Enables Ferromagnetic Material Sputtering) |
| Sample Stage | 6-Position Rotating Substrate Holder (5 Water-Cooled Positions + 1 Heated Position up to 600 °C ±1 °C) |
| Substrate Size | Ø25.4 mm (1″), 6 Slots |
| Substrate Bias | Adjustable DC Bias up to –200 V |
| Load-lock Annealing Capability | Up to 800 °C ±1 °C |
| In-situ Reverse Sputter Cleaning | Yes |
| Inter-chamber Transfer | Magnetic Coupling Sample Transfer Mechanism |
| Cooling | Integrated Recirculating Chiller (Deionized/Purified Water Required) |
| Electrical Supply | AC 380 V, 50 Hz, Grounded |
| Process Gases | High-Purity Ar or N₂ (≥99.99%) |
| Ambient Operating Conditions | Altitude ≤1000 m |
| Overall Footprint | 2700 × 900 × 2000 mm (L×W×H) |
| Weight Support Requirement | ≥1000 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-LCD |
| Display | 6" Industrial Touchscreen HMI |
| Power Supply | AC 220 V / 50 Hz, 23 W |
| Dimensions (L×W×H) | 600 × 745 × 700 mm |
| Cabinet Load Capacity | 1000 lbs (454 kg) |
| Operating Temperature | 5–45 °C |
| Max Working Pressure | 3 × 10⁶ Pa (30 bar) |
| Accuracy | ±1.5 % FS |
| Linearity | ±(0.5–1.5) % FS |
| Repeatability | ±0.2 % FS |
| Flow Ranges (configurable per channel) | Channel 1: 0–100 SCCM |
| Channel 2 | 1–199 SCCM |
| Channel 3 | 1–199 SCCM |
| Channel 4 | 1–499 SCCM |
| Channel 5+ | customizable upon request |
| Gas Mixing Vessel | Φ80 × 120 mm 316 stainless steel |
| Tubing | Internal – 1/4" SS |
| Pressure Gauge | Mechanical, -0.1 to 0.15 MPa (0.01 MPa/div) |
| Valves | 316 SS needle valves & shut-off valves |
| Communication | RS485 interface with PC-compatible control software |
| Compliance | Designed for laboratory-scale CVD and thermal processing environments |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GSL-PECVD-300 |
| Pricing | Upon Request |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-2Z / GSL-3Z / GSL-4Z |
| Power Supply | 185–245 VAC, 50 Hz |
| Max. Output Power | 18 W |
| Flow Range (per Channel) | GSL-2Z — Ch1: 1–199 SCCM, Ch2: 1–499 SCCM |
| GSL-3Z — Ch1 | 0–100 SCCM, Ch2: 1–199 SCCM, Ch3: 1–499 SCCM |
| GSL-4Z — Ch1 | 0–100 SCCM, Ch2: 1–199 SCCM, Ch3: 1–199 SCCM, Ch4: 1–499 SCCM |
| Max. Operating Pressure | 3 MPa |
| Accuracy | ±1% FS |
| Linearity | ±0.5–1.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (Gas) | 1–4 s |
| (Electrical) | ≤10 s |
| Needle Valve Material | 316 Stainless Steel |
| Operating Pressure Differential | 0.1–0.5 MPa |
| Vacuum/Pressure Gauge Range | –0.1 to +0.15 MPa (0.01 MPa/div) |
| Mixing Chamber | Ø80 mm × 120 mm |
| Shut-off Valve | 1/4″ BSP, 316 SS |
| Ambient Operating Temperature | 5–45 °C |
| Dimensions (W×D×H) | 600 × 600 × 650 mm |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL-ZDDZS-500 |
| Pricing | Upon Request |
| Ultimate Vacuum | ≤6.67×10⁻⁵ Pa (after bake-out) |
| Leak Rate | ≤5.0×10⁻⁷ Pa·L/s |
| Base Pressure Recovery | 6.6×10⁻⁴ Pa within 45 min after N₂ purge and pump-down |
| Chamber Dimensions | Ø500 mm × 600 mm (U-shaped, 304 stainless steel, electropolished, metal or Viton-sealed) |
| Substrate Holder | Accommodates Ø4″ wafers with manual shutter |
| E-Gun | E-type, anode voltage 6 kV / 8 kV |
| Cooling | Integrated recirculating chiller (deionized water, <25 °C, 0.25–0.4 MPa, ≥12 L/min) |
| Electrical Supply | AC 380 V, 50 Hz, ≥10 kW, voltage fluctuation <±6%, grounding resistance <2 Ω |
| Process Gas | High-purity N₂ or Ar (≥99.99%, supplied via 10 mm double-ferrule fitting with regulator) |
| Footprint | 1800 mm × 1200 mm × 2000 mm (W×D×H) |
| Ventilation | Required external exhaust ducting |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GSL1100X-PJF |
| Instrument Type | Atmospheric-Pressure Plasma Jet System |
| Input Voltage | 110/220 V, 50/60 Hz |
| Power Consumption | <1000 W |
| RF Output Frequency | 20–23 kHz |
| Gas Supply Pressure | ≥0.275 MPa |
| Operating Plasma Pressure | 0.048–0.068 MPa |
| Nozzle Options | Ø10–12 mm circular or 15–18 mm rectangular |
| Dimensions (W×D×H) | 500 × 380 × 210 mm |
| Weight | 10 kg |
| Ambient Operating Conditions | ≤42 °C, ≤40 % RH, non-flammable atmosphere |
| Certifications | CE compliant |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GZK-101 |
| Power Supply | 220 V, 50/60 Hz |
| Mobile Frame Dimensions | 600 mm × 600 mm × 600 mm, Load Capacity: 454 kg (1000 lbs), Equipped with Four Swivel Casters |
| TRP-12 Rotary Vane Pump | Motor Power: 550 W, Pumping Speed: 4 L/s, Ultimate Pressure: 4.0 × 10⁻² Pa |
| System Base Pressure (Measured) | ≤ 0.5 Pa |
| Max. Input Power | 110 W |
| Ultimate System Vacuum | 6.7 × 10⁻⁴ mbar (≈ 5 × 10⁻⁴ Torr) |
| Oil Reservoir Volume | 1000 mL |
| Vacuum Gauge | CVM-211 Digital Pirani/Cold Cathode Hybrid Gauge, Range: 1 × 10⁻¹ Pa to 1 × 10⁵ Pa |
| Flange Material | ASTM A240 Grade 316 Stainless Steel |
| Inlet Port | KF-25 (ISO-KF) |
| Exhaust Port | 1/8" Barb Fitting |
| Bellows | Ø25.4 mm × 1000 mm, Stainless Steel |
| High-Vacuum Isolation Valve | Dual KF-25 Stainless Steel Gate Valve |
| Standard Accessories | (1) KF-40 Stainless Steel Bellows (1000 mm), (2) KF-40 Clamps, (1) KF-25 Clamp, (1) KF-25 T-Fitting, (1) CVM-211 Vacuum Gauge |
| Overall Dimensions | 800 mm × 600 mm × 600 mm |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GZK-103D |
| Quotation | Available Upon Request |
| Vacuum Range | 1×10⁻³ to <1×10⁻⁷ mbar |
| Ultimate Pressure | <1×10⁻⁷ mbar (with Edwards pump) |
| Pumping Speed | N₂: 42 L/s, He: 49 L/s, H₂: 45 L/s |
| Startup Time | ≤2 min |
| Input Voltage | 185–265 V AC |
| Power Consumption | 100 W (continuous), 110 W (max) |
| Mobile Cart Dimensions | 600 × 600 × 700 mm (L×W×H) |
| Load Capacity | 150 kg (600 lbs) |
| Control Interface | Integrated LCD panel with one-touch start |
| Pre-pump | Edwards dual-stage diaphragm pump |
| Main pump | Edwards turbo-molecular pump |
| Vacuum Line | 1200 mm KF40 stainless-steel bellows |
| Standard Fittings | 1× KF40 vacuum flange, 1× KF40 butterfly valve, 1× flange support bracket, 1× KF40 clamp |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GZK-103GS |
| Quotation | Upon Request |
| Ambient Temperature | 5–32 °C |
| Relative Humidity | ≤80% |
| Input Voltage | 220 V ±10%, 50–60 Hz |
| Power Consumption | 1 kW |
| Ultimate System Vacuum | 1.0 × 10⁻⁴ Pa |
| Dimensions (W × D × H) | 600 × 600 × 750 mm |
| Mechanical Pump | 4 L/s pumping speed, 400 W motor, ultimate pressure 6 × 10⁻² Pa |
| Turbo Molecular Pump (F-100/110) | 100 L/s nominal pumping speed, ultimate pressure 6 × 10⁻⁶ Pa, startup time <2 min, rated speed 4300 rpm, air/water cooling |
| Turbo Pump Power Supply | 200–240 V input, 250 W output, acceleration time 3 min, output frequencies: high-speed 704 Hz ±10%, low-speed 430 Hz ±10% |
| ZDF-III Composite Vacuum Gauge | 220 V, 50–60 Hz |
| High-Vacuum Manual Isolation Valve | fluorocarbon elastomer (FKM) seal, quick-release CF flange, leak rate ≤5 × 10⁻⁹ Pa·m³/s |
| Stainless Steel Tubing & Fittings | electropolished 304/316 SS, welded joints with leak rate <1 × 10⁻⁹ Pa·m³/s |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HF-PJ-10/14 |
| Max. Operating Temperature | 1000 °C (optional 1400 °C) |
| Heating Rate | 0–20 °C/min (programmable) |
| Expansion Measurement Range | 0–3 mm |
| Resolution | 0.1–1 µm |
| Sample Dimensions | Ø6–10 mm × 50 mm (cylindrical or prismatic) |
| Accuracy | ±0.1–0.5% |
| Power Supply | 220 V ±10%, 50 Hz |
| Max. Power Consumption | 2.5 kW |
| Interface | Standard RS-232/USB computer interface |
| Compliance | GB/T 3810.8–2016, GB/T 16920–1997, YB/T 4-2003, GB/T 7320–2008 |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HP-100 |
| Heating Plate Material | Cr12MoV Tool Steel |
| Max Operating Temperature | 500 °C (<30 min) |
| Continuous Operating Temperature | 450 °C (with water cooling) |
| Max Applied Pressure (heated) | 12 Ton (20 MPa gauge reading) |
| Heating Plate Dimensions | 90 mm × 90 mm |
| Temperature Control Precision | ±1 °C |
| Programmable Ramp/Soak | 30-segment |
| Cooling | Integrated 1/4" BSP water-cooling ports |
| Power Supply | Single-phase AC 208–240 V, 50/60 Hz |
| Max Power Consumption | 1.6 kW |
| Max Stroke | 50 mm |
| Unit Weight | 60 kg |
| Optional Accessory | External Chiller Unit |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPM-1.6 |
| Instrument Type | Manual Pellet Press |
| Maximum Force | 1600 N |
| Stroke Range | 0–40 mm |
| Platen Dimensions | 75 mm × 50 mm |
| Center Hole Diameter (Platen) | 20H7 |
| Mounting Hole Diameter | 10H7 |
| Adjustable Height Range | 50–150 mm |
| Overall Dimensions (L×W×H) | 200 mm × 150 mm × 400 mm |
| Net Weight | 8 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPM-12 |
| Instrument Type | Manual Hydraulic Pellet Press |
| Max Force | 12,000 N |
| Stroke Range | 0–45 mm |
| Platen Dimensions | 150 mm × 110 mm |
| Platen Bore Diameter | Ø20H7 |
| Mounting Hole Diameter | Ø10H7 |
| Adjustable Height Range | 80–210 mm |
| Overall Dimensions (W×D×H) | 250 mm × 150 mm × 600 mm |
| Net Weight | 23 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HT-150 |
| Pricing | Available Upon Request |
| Heating Plate Diameter | 170 mm |
| Max Substrate Size | 6-inch round wafer |
| Max Temperature | 250 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.2 °C (at setpoint) |
| Surface Uniformity | < ±1% |
| Power Input | 220 V, 5 A, 800 W |
| Dimensions (W×D×H) | 369 × 270 × 126 mm |
| Weight | 8 kg |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | HT-200 |
| Max. Temperature | 300 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Resolution | 0.1 °C |
| Surface Uniformity | <±1% |
| Timer Range | 0–100,000 s |
| Time Resolution | 0.1 s |
| Chuck Size | 220 mm × 220 mm |
| Lift Pin Travel | 0–30.0 mm |
| Lift Resolution | 0.1 mm |
| Heating Power | 1000 W |
| Program Storage | 100 recipes × 5 stages each |
| Compatible Substrate Diameter | ≥40 mm |
| Touch Interface | 7″ Full-Color TFT LCD |
| Construction | Stainless Steel Frame + Hard-Anodized Aluminum Heating Plate |
| Optional Features (HT-200B) | Vacuum Chuck, Radiant Heat Shield, Linear Ramp Control |