- All
- Favorite
- Popular
- Most rated
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB900 |
| Chamber Volume | 500 L |
| Heating Power | 5100 W |
| Wash Temperature | Adjustable |
| Compatible Detergent Types | Alkaline and Acidic |
| External Dimensions (L×W×D) | 1140 × 915 × 1900 mm |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB 600D |
| Chamber Volume | 200 L |
| Heating Power | 7.5 kW |
| Temperature Range | Adjustable (up to 93 °C for thermal disinfection) |
| Compatible Detergent Types | Alkaline and acidic solutions |
| External Dimensions (L×W×H) | 650 × 660 × 1685 mm |
| Power Supply | 400 V, 3-phase, 50 Hz |
| Max. Noise Level | 56 dB(A) |
| Construction Material | AISI 316L stainless steel chamber |
| Compliance | EN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC |
| Drying System | HEPA-filtered hot air (ambient to 140 °C) |
| Programmability | 20 pre-installed + 20 user-defined cycles |
| Interface | LED display with RS232 port for data logging, program upload/download, and printer connectivity |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TL-100, TL-200, HSTL-200 |
| Capacity | Up to 500 vials/min (HSTL-200, dependent on vial geometry and tray configuration) |
| Vial Compatibility | 2–500 mL serum vials & reagent bottles |
| Control System | PLC-based menu-driven HMI with auto-configurable changeover logic |
| Nesting | Fully automatic nested tray loading |
| Dimensions (L×W×D) | Custom-engineered per integration requirements |
| Compliance | Designed in accordance with cGMP, ISO 13485-aligned architecture, FDA 21 CFR Part 11–ready data handling infrastructure |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS(C) Series Sterile Filling & Stoppering System |
| Pricing | Available Upon Request |
| Chamber Volume | Not Applicable (Inline Continuous-Flow System) |
| Heating Power | Not Applicable (No Integrated Heating Element) |
| Wash Temperature | Not Applicable (Not a Washing Device) |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Custom-Configurable per Line Integration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AC-6 |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | Not Applicable |
| Wash Temperature | Not Applicable |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Not Specified |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB 900 Series |
| Chamber Volume | 500 L |
| Heating Power | 5100 W |
| Wash Temperature | Adjustable (up to 93 °C for thermal disinfection) |
| Compatible Detergent Types | Alkaline and Acidic Solutions |
| External Dimensions (L×W×D) | 1140 × 915 × 1900 mm |
| Compliance | EN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EEC, 06/95/EEC, 89/336/EEC, 92/31/EEC, 93/68/EEC |
| Control Interface | LED Display with RS232 Port |
| Drying Air | HEPA-filtered, 20–140 °C adjustable |
| Door | Double-insulated, acoustic noise ≤58 dB(A) |
| Chamber Material | AISI 316L stainless steel, mirror-polished, weld-free rounded corners and sloped base |
| Filtration | Triple-layer stainless steel filter system |
| Standard Accessories | Built-in reagent cabinet, steam condenser, three pre-heating water tanks, two PT1000 temperature sensors, two peristaltic detergent pumps (expandable to four) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RW-Series (RW-250 / RW-500 / RW-800 / RW-1150) |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable (Modular Conveyor-Based Design) |
| Heating Power | Not Integrated (External Rinse/Preheat Options Available) |
| Wash Temperature | Ambient to 85 °C (Configurable via External Hot Water Supply) |
| Wash Liquid Compatibility | Aqueous Detergents, Sterile Water, WFI, Purified Water |
| External Dimensions (L×W×D) | Model-Dependent (RW-250: ~1,800 × 900 × 1,200 mm |
| RW-1150 | ~3,200 × 1,300 × 1,450 mm) |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model Series | LAB500, LAB680, LAB1000 |
| Chamber Volume | 171 L (LAB500) / 600 L (LAB680) / 500 L (LAB1000) |
| Max. Load Height | 440 mm (single-tier, LAB500) / 210 mm (dual-tier, LAB500) / up to 5 tiers (LAB680/LAB1000) |
| Thermal Disinfection Temperature | 93 °C (EN ISO 15883-1/2 compliant) |
| Power Supply | 400 V, 3-phase, 50 Hz |
| Heating Power | 5.6 kW (LAB500) / 20 kW (LAB680 & LAB1000) |
| Pump Power | 550 W (LAB500) / 550 + 900 W (LAB680 & LAB1000) |
| Noise Level | ≤52 dB(A) (LAB500) / ≤58 dB(A) (LAB680 & LAB1000) |
| Operating Ambient | +5 °C to +40 °C |
| Drying System | HEPA-filtered hot air (adjustable 20–140 °C) |
| Water Inlets | Cold, hot, and deionized water |
| Control Interface | LED display (LAB500) / LCD (LAB680) / Color touchscreen (LAB1000) |
| Program Capacity | 5 pre-installed + up to 40 user-defined (LAB500) / 20 factory + 20 user (LAB680) / up to 65 total (LAB1000) |
| Data Output | RS232 port for program upload/download, fault diagnostics, and printer connectivity |
| Chamber Material | AISI 316L stainless steel, mirror-polished, welded-free rounded corners and sloped base |
| Filtration | Triple-layer stainless steel filter system |
| Optional | View window, steam condenser (standard), automatic glass door (LAB1000) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Sterilization Tunnel |
| Quotation | Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | Not Specified |
| Wash Temperature | Not Applicable |
| Cleaning Solution Type | Not Applicable |
| External Dimensions (L×W×D) | Not Specified |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB 500 |
| Chamber Volume | 171 L |
| Heating Power | 5100 W |
| Wash Temperature | Adjustable (up to 93 °C) |
| Compatible Detergents | Alkaline and Acidic Solutions |
| External Dimensions (L×W×D) | 600 × 630 × 850 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EVW-60 / EVW-100 / High-Capacity External Washer |
| Capacity | 100–500 vials/min |
| Vial Size Range | 2–500 mL |
| Sealing Mechanism | Dual Opposing Conveyor Belt with Watertight Aluminum Cap Seal |
| Cleaning Method | Pressurized Spray (External Surface Only) |
| Compliance | Designed in Conformance with cGMP, FDA 21 CFR Part 11 (Audit Trail Ready), ISO 13485 Supportable |
| Footprint | Custom-Configurable (No Fixed Dimensions Provided) |
| Brand | INNOTEG |
|---|---|
| Model | EasyClean-200 / EasyClean-260 |
| Chamber Volume | 200 L / 260 L |
| Heating Power | 5 kW / 10 kW |
| Cleaning Medium | Aqueous-based detergent solutions |
| External Dimensions (L×W×D) | 900×650×860 mm / 672×660×1835 mm |
| Construction Material | 316L mirror-finish stainless steel interior |
| Control System | Siemens PLC with 7-inch color touchscreen (bilingual UI) |
| Wash Programs | 20 pre-installed + 20 user-customizable |
| Safety | Triple-level access control, electronic door lock (USA-sourced), real-time fault alarm & auto-shutdown |
| Circulation Pump | Perfecta (Sweden), 0–600 L/min, soft-start & overload protection |
| Spray System | Dual rotating upper/lower spray arms with asymmetric fan nozzles |
| Optional Features | Cloud-connected IoT monitoring (GPS + remote diagnostics), integrated conductivity sensor for final rinse water quality verification |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB 680 |
| Chamber Volume | 600 L |
| Heating Power | 18 kW |
| Wash Temperature | Adjustable (up to 93 °C for thermal disinfection) |
| Compatible Detergents | Alkaline and acidic solutions |
| External Dimensions (L×W×H) | 1140 × 930 × 1975 mm |
| Compliance | EN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC |
| Drying System | HEPA-filtered hot air (ambient–140 °C adjustable) |
| Noise Level | ≤58 dB(A) |
| Power Supply | 400 V, 3-phase, 50 Hz |
| Max. Total Power | 20 kW |
| Filtration | Triple-layer stainless steel mesh filter |
| Chamber Material | AISI 316L mirror-polished stainless steel with seamless, welded-free sloped bottom and radius corners |
| Standard Features | Dual PT1000 temperature sensors, dual peristaltic detergent pumps (expandable to four), automatic level sensing, RS232 interface with real-time data logging and remote diagnostics, LED display with program status and fault codes, steam condenser, double-insulated door, viewing window |
| Brand | Steelco |
|---|---|
| Origin | Italy |
| Model | LAB 610D |
| Chamber Volume | 250 L |
| Heating Power | 7.5 kW |
| Temperature Range | 0–100 °C |
| External Dimensions (L×W×H) | 650 × 687 × 1840 mm |
| Power Supply | 400 V, 3-phase, 50 Hz |
| Max. Noise Level | 57.5 dB(A) |
| Compliance | EN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC |
| Drying System | HEPA-filtered hot air, adjustable 20–140 °C |
| Standard Features | Dual PT1000 temperature sensors, dual peristaltic detergent dosing pumps (expandable to four), triple stainless steel filtration, AISI 316L mirror-polished chamber with welded-free sloped bottom, integrated steam condenser, RS232 interface with real-time data logging and printer support |
Show next