BrandSteelco
OriginItaly
ModelLAB900
Chamber Volume500 L
Heating Power5100 W
Wash TemperatureAdjustable
Compatible Detergent TypesAlkaline and Acidic
External Dimensions (L×W×D)1140 × 915 × 1900 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
ModelLAB 600D
Chamber Volume200 L
Heating Power7.5 kW
Temperature RangeAdjustable (up to 93 °C for thermal disinfection)
Compatible Detergent TypesAlkaline and acidic solutions
External Dimensions (L×W×H)650 × 660 × 1685 mm
Power Supply400 V, 3-phase, 50 Hz
Max. Noise Level56 dB(A)
Construction MaterialAISI 316L stainless steel chamber
ComplianceEN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC
Drying SystemHEPA-filtered hot air (ambient to 140 °C)
Programmability20 pre-installed + 20 user-defined cycles
InterfaceLED display with RS232 port for data logging, program upload/download, and printer connectivity
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTL-100, TL-200, HSTL-200
CapacityUp to 500 vials/min (HSTL-200, dependent on vial geometry and tray configuration)
Vial Compatibility2–500 mL serum vials & reagent bottles
Control SystemPLC-based menu-driven HMI with auto-configurable changeover logic
NestingFully automatic nested tray loading
Dimensions (L×W×D)Custom-engineered per integration requirements
ComplianceDesigned in accordance with cGMP, ISO 13485-aligned architecture, FDA 21 CFR Part 11–ready data handling infrastructure
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFS(C) Series Sterile Filling & Stoppering System
PricingAvailable Upon Request
Chamber VolumeNot Applicable (Inline Continuous-Flow System)
Heating PowerNot Applicable (No Integrated Heating Element)
Wash TemperatureNot Applicable (Not a Washing Device)
Cleaning Solution TypeNot Applicable
External Dimensions (L×W×D)Custom-Configurable per Line Integration
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAC-6
QuotationUpon Request
Chamber VolumeNot Applicable
Heating PowerNot Applicable
Wash TemperatureNot Applicable
Cleaning Solution TypeNot Applicable
External Dimensions (L×W×D)Not Specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
ModelLAB 900 Series
Chamber Volume500 L
Heating Power5100 W
Wash TemperatureAdjustable (up to 93 °C for thermal disinfection)
Compatible Detergent TypesAlkaline and Acidic Solutions
External Dimensions (L×W×D)1140 × 915 × 1900 mm
ComplianceEN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EEC, 06/95/EEC, 89/336/EEC, 92/31/EEC, 93/68/EEC
Control InterfaceLED Display with RS232 Port
Drying AirHEPA-filtered, 20–140 °C adjustable
DoorDouble-insulated, acoustic noise ≤58 dB(A)
Chamber MaterialAISI 316L stainless steel, mirror-polished, weld-free rounded corners and sloped base
FiltrationTriple-layer stainless steel filter system
Standard AccessoriesBuilt-in reagent cabinet, steam condenser, three pre-heating water tanks, two PT1000 temperature sensors, two peristaltic detergent pumps (expandable to four)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelRW-Series (RW-250 / RW-500 / RW-800 / RW-1150)
QuotationUpon Request
Chamber VolumeNot Applicable (Modular Conveyor-Based Design)
Heating PowerNot Integrated (External Rinse/Preheat Options Available)
Wash TemperatureAmbient to 85 °C (Configurable via External Hot Water Supply)
Wash Liquid CompatibilityAqueous Detergents, Sterile Water, WFI, Purified Water
External Dimensions (L×W×D)Model-Dependent (RW-250: ~1,800 × 900 × 1,200 mm
RW-1150~3,200 × 1,300 × 1,450 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
Model SeriesLAB500, LAB680, LAB1000
Chamber Volume171 L (LAB500) / 600 L (LAB680) / 500 L (LAB1000)
Max. Load Height440 mm (single-tier, LAB500) / 210 mm (dual-tier, LAB500) / up to 5 tiers (LAB680/LAB1000)
Thermal Disinfection Temperature93 °C (EN ISO 15883-1/2 compliant)
Power Supply400 V, 3-phase, 50 Hz
Heating Power5.6 kW (LAB500) / 20 kW (LAB680 & LAB1000)
Pump Power550 W (LAB500) / 550 + 900 W (LAB680 & LAB1000)
Noise Level≤52 dB(A) (LAB500) / ≤58 dB(A) (LAB680 & LAB1000)
Operating Ambient+5 °C to +40 °C
Drying SystemHEPA-filtered hot air (adjustable 20–140 °C)
Water InletsCold, hot, and deionized water
Control InterfaceLED display (LAB500) / LCD (LAB680) / Color touchscreen (LAB1000)
Program Capacity5 pre-installed + up to 40 user-defined (LAB500) / 20 factory + 20 user (LAB680) / up to 65 total (LAB1000)
Data OutputRS232 port for program upload/download, fault diagnostics, and printer connectivity
Chamber MaterialAISI 316L stainless steel, mirror-polished, welded-free rounded corners and sloped base
FiltrationTriple-layer stainless steel filter system
OptionalView window, steam condenser (standard), automatic glass door (LAB1000)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelSterilization Tunnel
QuotationUpon Request
Chamber VolumeNot Applicable
Heating PowerNot Specified
Wash TemperatureNot Applicable
Cleaning Solution TypeNot Applicable
External Dimensions (L×W×D)Not Specified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
ModelLAB 500
Chamber Volume171 L
Heating Power5100 W
Wash TemperatureAdjustable (up to 93 °C)
Compatible DetergentsAlkaline and Acidic Solutions
External Dimensions (L×W×D)600 × 630 × 850 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEVW-60 / EVW-100 / High-Capacity External Washer
Capacity100–500 vials/min
Vial Size Range2–500 mL
Sealing MechanismDual Opposing Conveyor Belt with Watertight Aluminum Cap Seal
Cleaning MethodPressurized Spray (External Surface Only)
ComplianceDesigned in Conformance with cGMP, FDA 21 CFR Part 11 (Audit Trail Ready), ISO 13485 Supportable
FootprintCustom-Configurable (No Fixed Dimensions Provided)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOTEG
ModelEasyClean-200 / EasyClean-260
Chamber Volume200 L / 260 L
Heating Power5 kW / 10 kW
Cleaning MediumAqueous-based detergent solutions
External Dimensions (L×W×D)900×650×860 mm / 672×660×1835 mm
Construction Material316L mirror-finish stainless steel interior
Control SystemSiemens PLC with 7-inch color touchscreen (bilingual UI)
Wash Programs20 pre-installed + 20 user-customizable
SafetyTriple-level access control, electronic door lock (USA-sourced), real-time fault alarm & auto-shutdown
Circulation PumpPerfecta (Sweden), 0–600 L/min, soft-start & overload protection
Spray SystemDual rotating upper/lower spray arms with asymmetric fan nozzles
Optional FeaturesCloud-connected IoT monitoring (GPS + remote diagnostics), integrated conductivity sensor for final rinse water quality verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
ModelLAB 680
Chamber Volume600 L
Heating Power18 kW
Wash TemperatureAdjustable (up to 93 °C for thermal disinfection)
Compatible DetergentsAlkaline and acidic solutions
External Dimensions (L×W×H)1140 × 930 × 1975 mm
ComplianceEN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC
Drying SystemHEPA-filtered hot air (ambient–140 °C adjustable)
Noise Level≤58 dB(A)
Power Supply400 V, 3-phase, 50 Hz
Max. Total Power20 kW
FiltrationTriple-layer stainless steel mesh filter
Chamber MaterialAISI 316L mirror-polished stainless steel with seamless, welded-free sloped bottom and radius corners
Standard FeaturesDual PT1000 temperature sensors, dual peristaltic detergent pumps (expandable to four), automatic level sensing, RS232 interface with real-time data logging and remote diagnostics, LED display with program status and fault codes, steam condenser, double-insulated door, viewing window
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSteelco
OriginItaly
ModelLAB 610D
Chamber Volume250 L
Heating Power7.5 kW
Temperature Range0–100 °C
External Dimensions (L×W×H)650 × 687 × 1840 mm
Power Supply400 V, 3-phase, 50 Hz
Max. Noise Level57.5 dB(A)
ComplianceEN ISO 15883-1/-2, EN 61010-1, EN 61010-2-040, EN 61326, EU Directives 98/37/EC, 2006/95/EC, 89/336/EEC, 92/31/EEC, 93/68/EEC
Drying SystemHEPA-filtered hot air, adjustable 20–140 °C
Standard FeaturesDual PT1000 temperature sensors, dual peristaltic detergent dosing pumps (expandable to four), triple stainless steel filtration, AISI 316L mirror-polished chamber with welded-free sloped bottom, integrated steam condenser, RS232 interface with real-time data logging and printer support