BrandPilodist
OriginGermany
ModelPD 105
Application DomainPetroleum & Petrochemical R&D, Fine Chemical Synthesis, High-Purity Separation
Operating Pressure RangeAtmospheric to Vacuum (≤ 0.1 mbar)
Temperature Control MethodProgrammable Oil Bath with PID Regulation
Reflux Ratio ControlAdjustable via Motorized Reflux Divider
Fraction Collection ModesTemperature-Triggered, Volume-Triggered, or Time-Triggered
Receiver Options6-, 9-, or 18-position Automated Fraction Collector with Overflow Protection
Software PlatformWindows-Based Control Suite with Real-Time Parameter Logging and Curve Visualization
Compliance FrameworkDesigned to Support ASTM D2892 (True Boiling Point Distillation), ASTM D5236 (Extended True Boiling Point), and ISO 3405
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelBOCLE D5001
Standard ComplianceASTM D5001
Test Duration30 min
LoadFixed Ball Load (Standardized per ASTM D5001)
Sample Volume50 mL
Temperature ControlPrecision Thermostatic Bath
Humidity & Airflow ControlIntegrated Environmental Regulation System
Measurement MethodOptical Microscopy of Wear Scar Dimensions (Major & Minor Axes)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelPD 100CC
ComplianceASTM D2892, ASTM D5236
Control SystemWindows-based PC software with real-time process visualization
Vacuum ControlAuto-adjusted residual pressure (100, 50, 10, 2 Torr) with manual override
Safety FeaturesOvertemperature shutdown, nitrogen purge activation, audible/visual alarms
Fraction Collection20-position airtight fraction collector with automated cooling, weighing, logging, and cleaning
InterfaceGround-glass joints with elastomeric seals — grease-free vacuum integrity
Distillation ModesIntegrated atmospheric-to-vacuum transition with automatic gap cooling
Data OutputExcel-native reporting, TBP curve generation, AET temperature conversion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelQUICKDIST 500 CC, QUICKDIST 500M
Operating Temperature (Flask)Up to 350°C
Final Boiling Point (AET)Up to 420°C
Operating PressureAtmospheric to <1 mbar (vacuum)
Theoretical PlatesUp to 60
Flask Volumes100 mL, 500 mL, 1 L, 2 L
Feed CapacityUp to 60% of flask volume
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPILODIST
OriginGermany
ModelPD300CC
Max. Distillation Temperature400 °C
Temperature Accuracy±0.1 °C
Cold Bath Temperature Range0–25 °C
Distillation Rate180–360 mL/h
Volume Detection Range1–200 mL
Volume Resolution0.1 mL
ComplianceASTM D1160
Control Interface15.6″ IP65-rated touchscreen with integrated thermal printer
Data Export FormatsPDF, XLS, CSV, TXT
SafetyDual independent heating safety circuits, auto-termination on AET limit, bath temperature limit, flask temperature limit, distillate volume limit, pressure drop, or flask fracture detection
Optional Accessory4-position automated fraction collector
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOrienda
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelSARAlyzer Elite
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelPD 104 / PD 107
ConstructionFull Borosilicate Glass (Duran®-grade)
Distillation ModeBatch, Vacuum-to-Atmospheric
Theoretical PlatesUp to 90
Minimum Sample Volume1 mL
Column TypeConcentric-Tube Precision Fractionating Column
Vessel Options0.05–20 L (Glass or SS)
Heating OptionsOil Bath or Electric Heating Mantle
ComplianceASTM D2892, D5236, ISO 9198, IP 123
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelSP200
Vacuum Range1–0.001 mbar
Temperature Control Accuracy±0.01 °C
Construction OptionsAll-Glass or Glass-Metal Hybrid
Evaporator TypeDouble-Jacketed Glass Rotating Film Evaporator
CondenserIntegrated Helical Coil Internal Condenser
DisplayLED Digital Readouts for Film Speed, Vacuum Pressure, and Temperature
Application ScopeLab-Scale & Pilot-Scale Molecular Distillation of Thermolabile, High-Boiling, High-Viscosity, or High-Molecular-Weight Organic Compounds
ComplianceDesigned to Support ASTM D2892 / D5236, ISO 9145, and GLP/GMP-aligned documentation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelVLE 110
Operating Pressure RangeVacuum to Overpressure (Configurable)
Temperature RangeAmbient to 250 °C
Temperature Accuracy±0.1 °C
Cold Bath Temperature Range−20 °C to 100 °C
Distillation Rate30 drops/min
Sample Volume Capacity100 mL
Volume Resolution1 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelPD1120CC
Standard ComplianceASTM D1120, SAE J1704
Automation LevelFully Automated
Test Duration8–15 min per sample
OutputPermanent thermal print + network-enabled PDF export
Regulatory ContextDesigned for GLP-compliant laboratories
Application ScopeEngine coolant and brake fluid equilibrium boiling point (EBP) determination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelPD 200CC
Standard ComplianceASTM D5236
Control SystemWindows-based PC-controlled automation
Collection Capacity12 fraction receivers with IR heating and level tracking
Safety FeaturesOvertemperature shutdown, nitrogen purge activation, user-definable alarm thresholds
Distillation ModeVacuum batch distillation with automatic AET conversion and cut-point assignment
Material ConstructionHigh-purity borosilicate glass (DIN/ISO 3585), ground-glass joints with elastomeric seals (no vacuum grease required)
Thermal ManagementAdaptive heating power modulation and dynamic coolant temperature control
Data OutputNative Excel export (.xlsx), real-time curve visualization (volume % vs. AET °C), GLP-compliant audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelPD 400CC
Standards ComplianceASTM D2892 & ASTM D5236
Distillation Capacity6 L (standard), optional 2–20 L
Max Operating Temperature420 °C (AET)
Pressure Range1–760 mmHg
Control SystemWindows-based PC automation with real-time monitoring and safety interlocks
Safety FeaturesOvertemperature shutdown, vacuum overpressure protection, power-fail emergency cooling, level/leak detection, automatic condenser and pot cooldown
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPilodist
OriginGermany
ModelTF 650
Operating Temperature Rangeup to 250 °C
Operating Pressure Range0.1–10 mbar (absolute)
Feed Rate0.5–10 L/h
Evaporation Area6.5 dm²
Construction MaterialHigh-grade stainless steel (SS 316L standard)
Dimensions (W × H × D)1.20 × 1.80 × 0.60 m
Ultimate Vacuum Capability≤0.001 mbar (with compatible vacuum system)