| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Analysis Principle | Dumas Combustion Method |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability (RSD) | < 0.5% |
| Recovery Rate | > 99.5% |
| Detection Limit | 0.001 mg N (He), 0.01 mg N (Ar) |
| Combustion Temperature | 1030 °C |
| Power Consumption | 1400 W |
| Auto-sampler Capacity | Up to 117 positions (4 trays × 30 positions) |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 55 kg |
| Electrical Supply | 230 V / 50 Hz |
| Gas Purity Requirement | ≥99.999% for He/Ar and O₂ |
| Gas Pressure Requirement | 2 bar for carrier gas and O₂ |
| Detector | Calibrated Thermal Conductivity Detector (TCD), reference-gas-free operation |
| Sample Mass Range | Up to 1.0 g |
| Data Interfaces | USB, RS232 |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Vector PCX |
| Temperature Range | 5 °C – 130 °C |
| Derivatization Reagent Flow Rate | 0.05 – 2.0 mL/min |
| Reaction Coil Volume | 0.1 – 3.0 mL |
| Construction | PEEK Fluidic Path |
| Flow Control | Electronic, Pulse-Free |
| Safety | Integrated Leak Detection, Over-Temperature & Over-Pressure Protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Innov-X |
|---|---|
| Origin | USA |
| Model | DELTA Series |
| Portability | Handheld |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <165 eV |
| Repeatability | ≥95% |
| Excitation Source | Micro-focus X-ray Tube (10–40 kV) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Weight | <1.5 kg |
| Operating System | Microsoft Windows Embedded CE |
| Battery Life | >4 hours continuous operation |
| Hot-Swap Battery Support | Yes |
| Display | 32-bit color touchscreen |
| Sample Targeting | Integrated camera + collimated beam optics |
| Trigger Options | Mechanical trigger, Deadman safety trigger, or external PC control |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | OXITEST |
| Instrument Type | Accelerated Oxidation Stability Analyzer |
| Pressure Range | 0–8 bar |
| Temperature Range | Ambient to 110 °C |
| Sample Volume | 100 mL per chamber |
| Power Consumption | 900 W |
| Voltage | 230 V / 50–60 Hz |
| Dimensions (L×W×H) | 365 × 190 × 485 mm |
| Weight | 16.5 kg |
| Safety Features | Integrated safety vacuum tube, visual over-temperature alarm, real-time fault indication |
| Compliance | CE-marked, IEC-compliant, ISO 9001 / ISO 14001 / ISO 45001 (formerly OHSAS 18001) certified |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Analysis Principle | Dumas Combustion Method |
| Measurement Range | 0.001–200 mg N (equivalent to ppm–100% N in sample) |
| Sample Weight | 200 mg–1 g |
| Digestion/Combustion Time | 3–4 min per sample |
| Repeatability | RSD < 0.5% (verified with EDTA reference standard) |
| Detection Limits | 0.01 mg C, 0.001 mg N |
| Recovery Rate | >99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 655 × 510 × 410 mm |
| Carrier Gas Options | Helium or Argon (dual-gas system, no hardware modification required) |
| Compliance | Designed for GLP/GMP environments |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK159 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated Kjeldahl System |
| Compliance Standards | AOAC, ISO 8968, ISO 1871, EPA 350.1, DIN 10492, DIN 10493 |
| Construction Materials | Corrosion-Resistant Polymer Front Panel, Titanium Condenser, Patented Polymer Anti-Splash Head |
| Safety Features | Tube Presence Sensor, Safety Door Interlock, Alkali Reservoir Guard Rod, Waste Tray Level Detection, Condensate Flow Monitoring, Reagent Volume Monitoring, Color-Coded Tubing |
| Titration Method | Photometric (Colorimetric) Titration per AOAC Official Method 981.10 |
| Interface Options | USB 2.0, RS-232, Optional Ethernet Connectivity |
| Data Management | Onboard Storage, GLP-Compliant Audit Trail, Export via USB Drive or PC Connection |
| Peripheral Compatibility | Integrated Balance Interface, Thermal Printer Support, External Computer Synchronization |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T2110 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lyotherm3 |
| Pricing | Available Upon Request |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 1525EF |
| Instrument Type | High-Pressure Semi-Preparative HPLC System |
| Application Level | Laboratory-Grade |
| Configuration | Dual-Flow Path Architecture (Analytical + Semi-Prep) |
| Sample Throughput | Single to High-Volume Batch Processing |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | EMA 502 |
| Detection Elements | C, H, N, S, O |
| Sample Forms | Solid, Paste, Liquid |
| Carrier Gases | Helium, Argon |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Software | EMASoft |
| Cloud Integration | VELP Ermes Platform |
| Automation | Optional Autosampler |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | UDK169 |
| Power Supply | 230 V / 50–60 Hz |
| Distillation Time | 3–4 min |
| Dispensing Precision | ±2 µL per step |
| Sample Capacity | 24 × 250 mL tubes (Ø42 mm) or 21 × 400 mL tubes (Ø52 mm) |
| Nitrogen Recovery Rate | 99.5% |
| Rated Power | 2250 W |
| Dimensions (W×H×D) | 830 × 1730 × 640 mm |
| Weight | 170 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK149 |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N |
| Recovery Rate | ≥99.5% (for N content between 0.1–200 mg) |
| Power Consumption | 2100 W |
| Dimensions (W×H×D) | 385 × 780 × 416 mm |
| Touchscreen Display | 3.5-inch color LCD |
| Data Storage Capacity | 50,000 test records |
| Stored Methods | 20 pre-programmed SOPs |
| Repeatability (RSD) | ≤1% |
| Detection Limit | ≥0.1 mg N |
| Steam Output Control | 10–100% adjustable |
| Cooling Water Flow | 0.5 L/min at 15°C |
| Alkali/Water/Acid Dispensing Volume | 0–150 mL / 0–200 mL / 0–100 mL |
| Distillation Time for 100 mL Water | 3 minutes |
| Weight | 27 kg |
| Power Supply | 230 V, 50–60 Hz |
| Connectivity | RS232, USB, TTL, Ehmet interface |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | UDK139 |
| Display | 3.5″ Color Touchscreen |
| Programmable Methods | 10 Custom Protocols |
| NaOH/H₂O Addition | Automatic (0–150 mL / 0–200 mL) |
| Steam Output Regulation | 10–100% |
| Cooling Water Consumption | 0.5 L/min at 15°C |
| Repeatability (RSD) | ≤1% |
| Nitrogen Recovery | ≥99.5% (for 1–200 mg N) |
| Detection Limit | ≥0.1 mg N |
| Distillation Time for 100 mL Water | 4 min |
| Power Rating | 2100 W |
| Voltage/Frequency | 230 V, 50–60 Hz |
| Dimensions (W×H×D) | 385 × 780 × 416 mm |
| Weight | 26 kg |
| Interface | 2×USB |
| Enclosure Material | Corrosion-Resistant Polymer Housing |
| Condenser | Titanium-Coated |
| Safety Sensors | Tube Presence, Safety Door Interlock, Alkali Container Guard Rod, Waste Tray Level, Condensate Flow, Reagent Volume Monitoring |
| Brand | VELP |
|---|---|
| Country of Origin | Italy |
| Model | UDK129 |
| Housing Material | Corrosion-Resistant Polymer |
| Display | LCD |
| Programmable Methods | User-Defined Protocols |
| NaOH Addition | Automated, 0–100 mL |
| Cooling Water Consumption | 0.5 L/min at 15°C, 1 L/min at 30°C |
| Distillation Time | ≤5 min for 100 mL water |
| Repeatability (RSD) | ≤1% |
| Nitrogen Recovery Rate | ≥99.5% (for N content 1–200 mg) |
| Detection Limit | ≥0.1 mg N |
| Power Rating | 2100 W |
| Voltage/Frequency | 230/115 V, 50/60 Hz |
| Dimensions (W×H×D) | 385 × 780 × 416 mm |
| Weight | 25 kg |
| Brand | Innov-X |
|---|---|
| Origin | USA |
| Model | XDD-5000 Series |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm – 99.99% |
| Energy Resolution | <165 eV |
| Repeatability | 95% |
| Weight | <12 kg |
| Excitation Source | 10 W Microfocus X-ray Tube |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Operating System | Windows XP |
| Configuration | Benchtop or Floor-Standing |
| Distribution Type | Imported Instrument via Authorized Distributor |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR15 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 30,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition) |
| Beam Diameter | 15 mm |
| Beamsplitter | Multi-layer Ge-coated KBr (imported) |
| Source | High-intensity air-cooled ceramic IR source (imported) |
| Interferometer | Michelson-type, self-compensating, automated alignment |
| Detector | Low-noise deuterated triglycine sulfate (DLATGS) detector (imported) |
| Baseline Flatness | ≤0.1% T |
| Measurement Modes | Transmittance, Absorbance, Radiant Energy |
| Dimensions (W×D×H) | 486 × 406 × 230 mm |
| Sample Compartment Size | 200 × 170 × 145 mm |
| Weight | 23 kg |
| Interface | USB 2.0 |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| OS Compatibility | Windows 10 (64-bit or later) |
| Operating Environment | 15–28 °C, RH <65% (non-condensing) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fourier 80 |
| Instrument Type | High-Field Benchtop NMR Spectrometer |
| Operating Frequency | 80 MHz (¹H) |
| Sensitivity | ≥240:1 (¹H single-channel, 1% ethylbenzene, standard) |
| ≥220 | 1 (¹H single-channel with pulsed field gradient) |
| ≥160 | 1 (¹H/X dual-channel with pulsed field gradient) |
| Resolution | Standard configuration: ≤0.4/15/30 Hz (at 50%/0.55%/0.11% peak height) |
| HD configuration | ≤0.3/10/15 Hz (at 50%/0.55%/0.11% peak height) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA701 |
| Analysis Method | Dumas combustion |
| Automation Level | Fully automated |
| Detection Limit | 0.003 mg N |
| Reproducibility (RSD) | < 0.5% |
| Recovery | > 99.5% |
| Combustion Temperature | 1030 °C |
| Sample Weight Capacity | up to 1 g |
| Autosampler Capacity | up to 116 samples |
| Carrier Gas | Helium (99.999% purity, 3 bar) |
| Oxygen Supply | 99.999% purity, 3 bar |
| Auxiliary Gas | Compressed air or nitrogen (99.6%, oil- and water-free, 4 bar) |
| Power Consumption | 1400 W |
| Dimensions (W×H×D) | 655 × 510 × 410 mm (655 × 690 × 410 mm with autosampler) |
| Weight | 54 kg |
| Interfaces | USB, RS232 |
| Compliance | AOAC, AACC, ASBC, ISO 14891, OIV |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SMB-8 |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China-Made) |
| Model | INNOTEG EasyPrep MP |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ≤ ±2% |
| Maximum Operating Pressure | 200 psi |
| UV Detection Wavelength Range | 200–400 nm |
| Baseline Noise | 1 × 10⁻⁴ AU (at 254 nm, water) |
| Spectral Range | 190–3200 nm |
|---|---|
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | PAS |
|---|---|
| Origin | Germany |
| Model | CONCEPT MIS |
| Instrument Type | GC Autosampler |
| Minimum Injection Volume | 1 µL |
| Positioning Accuracy | <0.3 mm |
| Motion System | XYZ Three-Axis |
| Needle Wash | Internal and External Wall Cleaning (Unlimited Cycles) |
| Re-injection Capability | Unlimited |
| Sample Introduction Modes | Liquid Injection (LI), Liquid–Liquid Extraction (LLE), Static/Dynamic Headspace (HS), Needle Trap (NT), Solid-Phase Microextraction (SPME), On-line Derivatization |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Brand | Waters |
|---|---|
| Model | Breeze2 GPC |
| Origin | USA |
| Instrument Type | Ambient-Temperature SEC System |
| UV Detector Noise | 1.5 × 10⁻⁹ RIU |
| Column Oven Temperature Range | 5 °C above ambient to 60 °C |
| Detection Modes | UV/Vis (2489), Refractive Index (2414) |
| Pump | 1500 Solvent Delivery Module |
| Autosampler | 2707 |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 45,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 1-minute acquisition) |
| Beam Diameter | 10 mm |
| Beamsplitter | Imported multi-layer germanium-coated KBr, Ø60 mm with anti-humidity coating |
| Source | Imported high-intensity air-cooled ceramic IR source |
| Detector | Imported low-noise deuterated triglycine sulfate (DLATGS) detector |
| Interferometer | Oscillating-mirror interferometer (space-derived optical architecture) |
| Baseline Flatness | ≤0.1% T |
| Dimensions (W×D×H) | ≥590 × 355 × 185 mm |
| Sample Compartment Size (W×D×H) | ≥200 × 255 × 150 mm |
| Weight | 26 kg |
| Interface | USB |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| Operating System | Windows 10 (64-bit or later) |
| Ambient Temperature | 15–28 °C |
| Relative Humidity | <65% RH (non-condensing) |
| Optional Features | N₂ purge port, built-in desiccant chamber with visual indicator, heater-assisted humidity control, adjustable interferometer energy output |