BrandVELP
OriginItaly
ModelNDA702
Analysis PrincipleDumas Combustion Method
Carrier GasesHelium or Argon (switchable without hardware modification)
Digestion/Combustion Time3–4 min per sample
Repeatability (RSD)< 0.5%
Recovery Rate> 99.5%
Detection Limit0.001 mg N (He), 0.01 mg N (Ar)
Combustion Temperature1030 °C
Power Consumption1400 W
Auto-sampler CapacityUp to 117 positions (4 trays × 30 positions)
Dimensions (W×D×H)655 × 510 × 410 mm
Weight55 kg
Electrical Supply230 V / 50 Hz
Gas Purity Requirement≥99.999% for He/Ar and O₂
Gas Pressure Requirement2 bar for carrier gas and O₂
DetectorCalibrated Thermal Conductivity Detector (TCD), reference-gas-free operation
Sample Mass RangeUp to 1.0 g
Data InterfacesUSB, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPickering
OriginUSA
ModelVector PCX
Temperature Range5 °C – 130 °C
Derivatization Reagent Flow Rate0.05 – 2.0 mL/min
Reaction Coil Volume0.1 – 3.0 mL
ConstructionPEEK Fluidic Path
Flow ControlElectronic, Pulse-Free
SafetyIntegrated Leak Detection, Over-Temperature & Over-Pressure Protection
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInnov-X
OriginUSA
ModelDELTA Series
PortabilityHandheld
Elemental RangeMg to U
Detection Limit1 ppm
Quantification Range1 ppm – 99.99%
Energy Resolution<165 eV
Repeatability≥95%
Excitation SourceMicro-focus X-ray Tube (10–40 kV)
DetectorHigh-Performance Silicon Drift Detector (SDD)
Weight<1.5 kg
Operating SystemMicrosoft Windows Embedded CE
Battery Life>4 hours continuous operation
Hot-Swap Battery SupportYes
Display32-bit color touchscreen
Sample TargetingIntegrated camera + collimated beam optics
Trigger OptionsMechanical trigger, Deadman safety trigger, or external PC control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelOXITEST
Instrument TypeAccelerated Oxidation Stability Analyzer
Pressure Range0–8 bar
Temperature RangeAmbient to 110 °C
Sample Volume100 mL per chamber
Power Consumption900 W
Voltage230 V / 50–60 Hz
Dimensions (L×W×H)365 × 190 × 485 mm
Weight16.5 kg
Safety FeaturesIntegrated safety vacuum tube, visual over-temperature alarm, real-time fault indication
ComplianceCE-marked, IEC-compliant, ISO 9001 / ISO 14001 / ISO 45001 (formerly OHSAS 18001) certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelCN802
Analysis PrincipleDumas Combustion Method
Measurement Range0.001–200 mg N (equivalent to ppm–100% N in sample)
Sample Weight200 mg–1 g
Digestion/Combustion Time3–4 min per sample
RepeatabilityRSD < 0.5% (verified with EDTA reference standard)
Detection Limits0.01 mg C, 0.001 mg N
Recovery Rate>99.5%
Power Consumption1400 W
Dimensions (L×W×H)655 × 510 × 410 mm
Carrier Gas OptionsHelium or Argon (dual-gas system, no hardware modification required)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK159
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelSemi-Automated Kjeldahl System
Compliance StandardsAOAC, ISO 8968, ISO 1871, EPA 350.1, DIN 10492, DIN 10493
Construction MaterialsCorrosion-Resistant Polymer Front Panel, Titanium Condenser, Patented Polymer Anti-Splash Head
Safety FeaturesTube Presence Sensor, Safety Door Interlock, Alkali Reservoir Guard Rod, Waste Tray Level Detection, Condensate Flow Monitoring, Reagent Volume Monitoring, Color-Coded Tubing
Titration MethodPhotometric (Colorimetric) Titration per AOAC Official Method 981.10
Interface OptionsUSB 2.0, RS-232, Optional Ethernet Connectivity
Data ManagementOnboard Storage, GLP-Compliant Audit Trail, Export via USB Drive or PC Connection
Peripheral CompatibilityIntegrated Balance Interface, Thermal Printer Support, External Computer Synchronization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOTEG
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelT2110
Temperature RangeAmbient to 400 °C
Gas Flow Rate0–200 mL/min
Tube Capacity10 tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiopharma
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelLyotherm3
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
OriginUSA
Model1525EF
Instrument TypeHigh-Pressure Semi-Preparative HPLC System
Application LevelLaboratory-Grade
ConfigurationDual-Flow Path Architecture (Analytical + Semi-Prep)
Sample ThroughputSingle to High-Volume Batch Processing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelEMA 502
Detection ElementsC, H, N, S, O
Sample FormsSolid, Paste, Liquid
Carrier GasesHelium, Argon
ComplianceAOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA
SoftwareEMASoft
Cloud IntegrationVELP Ermes Platform
AutomationOptional Autosampler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK169
Power Supply230 V / 50–60 Hz
Distillation Time3–4 min
Dispensing Precision±2 µL per step
Sample Capacity24 × 250 mL tubes (Ø42 mm) or 21 × 400 mL tubes (Ø52 mm)
Nitrogen Recovery Rate99.5%
Rated Power2250 W
Dimensions (W×H×D)830 × 1730 × 640 mm
Weight170 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK149
Instrument TypeAutomated Kjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–200 mg N
Recovery Rate≥99.5% (for N content between 0.1–200 mg)
Power Consumption2100 W
Dimensions (W×H×D)385 × 780 × 416 mm
Touchscreen Display3.5-inch color LCD
Data Storage Capacity50,000 test records
Stored Methods20 pre-programmed SOPs
Repeatability (RSD)≤1%
Detection Limit≥0.1 mg N
Steam Output Control10–100% adjustable
Cooling Water Flow0.5 L/min at 15°C
Alkali/Water/Acid Dispensing Volume0–150 mL / 0–200 mL / 0–100 mL
Distillation Time for 100 mL Water3 minutes
Weight27 kg
Power Supply230 V, 50–60 Hz
ConnectivityRS232, USB, TTL, Ehmet interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK139
Display3.5″ Color Touchscreen
Programmable Methods10 Custom Protocols
NaOH/H₂O AdditionAutomatic (0–150 mL / 0–200 mL)
Steam Output Regulation10–100%
Cooling Water Consumption0.5 L/min at 15°C
Repeatability (RSD)≤1%
Nitrogen Recovery≥99.5% (for 1–200 mg N)
Detection Limit≥0.1 mg N
Distillation Time for 100 mL Water4 min
Power Rating2100 W
Voltage/Frequency230 V, 50–60 Hz
Dimensions (W×H×D)385 × 780 × 416 mm
Weight26 kg
Interface2×USB
Enclosure MaterialCorrosion-Resistant Polymer Housing
CondenserTitanium-Coated
Safety SensorsTube Presence, Safety Door Interlock, Alkali Container Guard Rod, Waste Tray Level, Condensate Flow, Reagent Volume Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK129
Housing MaterialCorrosion-Resistant Polymer
DisplayLCD
Programmable MethodsUser-Defined Protocols
NaOH AdditionAutomated, 0–100 mL
Cooling Water Consumption0.5 L/min at 15°C, 1 L/min at 30°C
Distillation Time≤5 min for 100 mL water
Repeatability (RSD)≤1%
Nitrogen Recovery Rate≥99.5% (for N content 1–200 mg)
Detection Limit≥0.1 mg N
Power Rating2100 W
Voltage/Frequency230/115 V, 50/60 Hz
Dimensions (W×H×D)385 × 780 × 416 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInnov-X
OriginUSA
ModelXDD-5000 Series
Elemental RangeMg to U
Detection Limit1 ppm – 99.99%
Energy Resolution<165 eV
Repeatability95%
Weight<12 kg
Excitation Source10 W Microfocus X-ray Tube
DetectorHigh-Performance Silicon Drift Detector (SDD)
Operating SystemWindows XP
ConfigurationBenchtop or Floor-Standing
Distribution TypeImported Instrument via Authorized Distributor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInnoteg
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelInnoFTIR15
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–350 cm⁻¹
Spectral Resolution<1.0 cm⁻¹
Signal-to-Noise Ratio (S/N)30,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition)
Beam Diameter15 mm
BeamsplitterMulti-layer Ge-coated KBr (imported)
SourceHigh-intensity air-cooled ceramic IR source (imported)
InterferometerMichelson-type, self-compensating, automated alignment
DetectorLow-noise deuterated triglycine sulfate (DLATGS) detector (imported)
Baseline Flatness≤0.1% T
Measurement ModesTransmittance, Absorbance, Radiant Energy
Dimensions (W×D×H)486 × 406 × 230 mm
Sample Compartment Size200 × 170 × 145 mm
Weight23 kg
InterfaceUSB 2.0
Power SupplyAC 220 V / DC 12 V, 40 W
OS CompatibilityWindows 10 (64-bit or later)
Operating Environment15–28 °C, RH <65% (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBruker
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelFourier 80
Instrument TypeHigh-Field Benchtop NMR Spectrometer
Operating Frequency80 MHz (¹H)
Sensitivity≥240:1 (¹H single-channel, 1% ethylbenzene, standard)
≥2201 (¹H single-channel with pulsed field gradient)
≥1601 (¹H/X dual-channel with pulsed field gradient)
ResolutionStandard configuration: ≤0.4/15/30 Hz (at 50%/0.55%/0.11% peak height)
HD configuration≤0.3/10/15 Hz (at 50%/0.55%/0.11% peak height)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelNDA701
Analysis MethodDumas combustion
Automation LevelFully automated
Detection Limit0.003 mg N
Reproducibility (RSD)< 0.5%
Recovery> 99.5%
Combustion Temperature1030 °C
Sample Weight Capacityup to 1 g
Autosampler Capacityup to 116 samples
Carrier GasHelium (99.999% purity, 3 bar)
Oxygen Supply99.999% purity, 3 bar
Auxiliary GasCompressed air or nitrogen (99.6%, oil- and water-free, 4 bar)
Power Consumption1400 W
Dimensions (W×H×D)655 × 510 × 410 mm (655 × 690 × 410 mm with autosampler)
Weight54 kg
InterfacesUSB, RS232
ComplianceAOAC, AACC, ASBC, ISO 14891, OIV
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeDistributor
Origin CategoryImported
ModelSMB-8
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOTEG
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (China-Made)
ModelINNOTEG EasyPrep MP
Instrument TypeMedium- to Low-Pressure Preparative Liquid Chromatography System
Flow Rate Range1–200 mL/min
Flow Accuracy≤ ±2%
Maximum Operating Pressure200 psi
UV Detection Wavelength Range200–400 nm
Baseline Noise1 × 10⁻⁴ AU (at 254 nm, water)
Added to wishlistRemoved from wishlist 0
Add to compare
Spectral Range190–3200 nm
Bandwidth (UV-VIS)0.2, 0.5, 1, 2, 3, 5 nm
Bandwidth (NIR)0.8, 2, 4, 8, 12, 20 nm
Wavelength Accuracy±0.5 nm (UV/VIS), ±2.0 nm (NIR)
Wavelength Repeatability≤0.3 nm (UV/VIS), ≤1.0 nm (NIR)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPAS
OriginGermany
ModelCONCEPT MIS
Instrument TypeGC Autosampler
Minimum Injection Volume1 µL
Positioning Accuracy<0.3 mm
Motion SystemXYZ Three-Axis
Needle WashInternal and External Wall Cleaning (Unlimited Cycles)
Re-injection CapabilityUnlimited
Sample Introduction ModesLiquid Injection (LI), Liquid–Liquid Extraction (LLE), Static/Dynamic Headspace (HS), Needle Trap (NT), Solid-Phase Microextraction (SPME), On-line Derivatization
ComplianceDesigned for GLP/GMP environments with audit-trail-ready software architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaters
ModelBreeze2 GPC
OriginUSA
Instrument TypeAmbient-Temperature SEC System
UV Detector Noise1.5 × 10⁻⁹ RIU
Column Oven Temperature Range5 °C above ambient to 60 °C
Detection ModesUV/Vis (2489), Refractive Index (2414)
Pump1500 Solvent Delivery Module
Autosampler2707
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInnoteg
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelInnoFTIR10
Instrument TypeLaboratory FTIR Spectrometer
Wavenumber Range7800–350 cm⁻¹
Spectral ResolutionBetter than 1.0 cm⁻¹
Signal-to-Noise Ratio (S/N)45,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 1-minute acquisition)
Beam Diameter10 mm
BeamsplitterImported multi-layer germanium-coated KBr, Ø60 mm with anti-humidity coating
SourceImported high-intensity air-cooled ceramic IR source
DetectorImported low-noise deuterated triglycine sulfate (DLATGS) detector
InterferometerOscillating-mirror interferometer (space-derived optical architecture)
Baseline Flatness≤0.1% T
Dimensions (W×D×H)≥590 × 355 × 185 mm
Sample Compartment Size (W×D×H)≥200 × 255 × 150 mm
Weight26 kg
InterfaceUSB
Power SupplyAC 220 V / DC 12 V, 40 W
Operating SystemWindows 10 (64-bit or later)
Ambient Temperature15–28 °C
Relative Humidity<65% RH (non-condensing)
Optional FeaturesN₂ purge port, built-in desiccant chamber with visual indicator, heater-assisted humidity control, adjustable interferometer energy output