| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Portable Refractometer |
| Measurement Range | 0.0–60.0 °Brix or 45–90 °Brix |
| Resolution | 0.1 °Brix |
| Accuracy | ±0.2 °Brix |
| Measurement Time | 2 s |
| Sample Volume | >0.1 mL |
| Operating Temperature | +10 °C to +70 °C |
| Measured Temperature Range | up to 100 °C |
| Power Supply | Battery-operated |
| Units | °Brix |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-BR |
| Product Type | In-line / Laboratory Refractometer |
| Temperature Control | Integrated Peltier-free prism temperature sensing |
| Digital Display | Backlit LCD (16×16 characters) |
| Measurement Range | 1.32000–1.54000 RI / 0–100 %Brix |
| Resolution | 0.00001 RI / 0.01 %Brix |
| Accuracy | ±0.00002 RI / ±0.01 %Brix (1.32–1.44), ±0.00003 RI / ±0.01 %Brix (1.44–1.54) |
| Repeatability | 0.00001 RI / 0.01 %Brix |
| Temperature Sensing | NTC sensor embedded in sapphire prism, accuracy ±0.03 °C, repeatability ±0.02 °C |
| Sample Volume | 0.3 mL |
| Prism Material | Sapphire |
| Light Source | LED with integrated interference filter, λ = 589 nm |
| Interfaces | RS-232C (bidirectional), Centronics parallel port, USB (optional) |
| Compliance | ASTM D1218, DIN 51757, ISO 21542, USP <781>, ICUMSA Method GS2/3-13, AOAC 932.12, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR-B/F new |
| Type | Benchtop Refractometer |
| Temperature Control | Built-in Peltier |
| Digital Display | 7" TFT Touchscreen |
| Measurement Range | 1.32000–1.7000 RI / 0–100% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Light Source | LED with 589 nm interference filter (>100,000 h lifetime) |
| Compliance | ASTM, ISO, DIN, USP, ICUMSA, FDA 21 CFR Part 11 ready (optional software), GLP/GMP compliant |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariRef A / B / C |
| Product Type | Inline Refractometer |
| Temperature Control | Dual-isolated Peltier system |
| Digital Display | 5" or 7" capacitive touchscreen (800 × 480 px, 16-bit color) |
| Measurement Range | 1.320000–1.580000 RI / 100% Brix (VariRef A) |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Repeatability | ±0.00001 RI / ±0.01% Brix |
| Temperature Control Range | +5°C to +100°C (VariRef B, customizable) |
| Temperature Accuracy | ±0.03°C |
| Prism Material | Sapphire (A & C), Sapphire/YAG (B) |
| Light Source | LED with integrated 589 nm interference filter |
| Compliance | ASTM D1218, ISO 2160, USP <781>, Ph. Eur. 2.2.12, ICUMSA Methods GS2/3-13, AOAC 932.12, DIN 51757, FDA 21 CFR Part 11 (software-enabled), GLP/GMP audit trail support |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM990-Flow |
| Refractive Index Range | 1.30–1.70 |
| Brix Range | 0–100 |
| RI Resolution | 0.00001 |
| Brix Resolution | 0.01 |
| RI Accuracy | ±0.00002 |
| Brix Accuracy | ±0.02 |
| Light Source | LED (589.3 nm, >100,000 hr lifetime) |
| Temperature Control | Integrated Peltier element |
| Sample Cell Volumes | 0.6 mL (micro), 1.2 mL (standard), 1.2 mL (funnel-type) |
| Compliance | OIML R22, ASTM D5006, USP <781>, EP 2.2.2, BP Appendix XVII, FDA 21 CFR Part 11, GLP/GMP data integrity requirements |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR W1 / W1 Plus / W2 / W2 Plus |
| Refractive Index Range | RI 1.33200–1.53200 (W1/W1 Plus), RI 1.33200–1.70000 (W2/W2 Plus) |
| Brix Range | 0–95% (W1/W1 Plus), 0–100% (W2/W2 Plus) |
| Resolution | RI 0.00002 / Brix 0.02 (W1/W1 Plus), RI 0.00001 / Brix 0.01 (W2/W2 Plus) |
| Accuracy | ±0.00004 RI / ±0.04 Brix (W1/W1 Plus), ±0.00002 RI / ±0.02 Brix (W2/W2 Plus) |
| Temperature Control | Peltier-controlled sapphire prism, operating range +10°C to +80°C |
| Brand | Bellingham + Stanley |
|---|---|
| Country of Origin | United Kingdom |
| Model | E-Line |
| Compliance | BS EN ISO 9001, UKAS Accredited, CE Marked |
| Optical Principle | Critical Angle Refraction (Abbe-type) |
| Temperature Compensation | Automatic Temperature Compensation (ATC) |
| Construction | All-metal body with thermal-insulating rubber grip |
| Ergonomics | Optimized hand-held geometry for single-handed operation |
| Scale Resolution | 0.1–0.5 °Brix depending on model |
| Measurement Range | 0–90 °Brix (multi-range variants available) |
| Prism Type | High-grade optical glass with spring-loaded flip cover |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | Germany |
| Model | RFM990-AUS32 |
| Refractive Index Range | 1.33–1.70 |
| Urea Concentration Range | 0–40% w/w |
| RI Resolution | 0.00001 |
| Urea Resolution | 0.01% |
| RI Accuracy | ±0.00002 |
| Urea Accuracy | ±0.02% |
| Temperature Control | Peltier (±0.1 °C) |
| Light Source | LED @ 589.3 nm (Lifespan >100,000 hr) |
| Temperature Compensation Modes | Urea-specific, ICUMSA sugar, AG, user-defined, none |
| Data Storage | 700 measurements with GLP-compliant audit trail |
| Interfaces | RS-232, parallel port |
| Sample Handling | Continuous flow compatible with multiple flow cell options |
| Compliance | ISO 22241-2, BS EN ISO 9001:2000, UKAS, CE |
| Brand | Bellingham + Stanley (B+S) |
|---|---|
| Country of Origin | United Kingdom |
| Model | OPTi Food Industry |
| Compliance | BS EN ISO 9001:2000, UKAS, CE |
| IP Rating | IP65 |
| Calibration | Pure water zero-point calibration |
| Temperature Compensation | Automatic (ATC) |
| Prism Design | Shallow-base, cleanable, no dead zones |
| Ergonomics | Human-engineered handheld form factor |
| Application Scope | Brix, RI, % Salt, % Urea, % Starch, Alcohol Probable (AP), Oechsle (DE/CH), KMW, °Baumé, ABV, °Plato |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Automated Liquid Dispensing System |
| Pricing | Upon Request |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | DHR |
| Type | Digital handheld refractometer |
| Temperature control | Yes (ATC) |
| Digital display | Yes (5-digit LCD) |
| Measurement range | 0–95 °Brix / 1.3300–1.5400 RI |
| Resolution | 0.1 °Brix / 0.0001 RI |
| Accuracy | ±0.2 °Brix / ±0.0003 RI |
| Operating sample temperature | 5–60 °C |
| Ambient temperature range | 5–40 °C |
| ATC compensation range | 5–70 °C |
| IP rating | IP65 |
| Compliance | CE, RoHS |
| Power | 2×AAA batteries |
| Dimensions (L×W×H) | 115×54×30 mm |
| Weight | 85 g (without batteries) |
| Prism material | Optical glass |
| Brand | Bellingham + Stanley (B+S) |
|---|---|
| Origin | United Kingdom |
| Model | Abbe 60/LR & Abbe 60/ED |
| Refractive Index Range | 1.20–1.70 RI (Abbe 60/LR), 1.30–1.74 RI (Abbe 60/ED) |
| Accuracy | ±0.00004 RI |
| Operating Temperature | 5–75 °C (digital display, 0.1 °C resolution) |
| Light Sources | Sodium D-line (589.3 nm), optional spectral lamps for multi-wavelength measurement |
| Compliance | ASTM D1218, BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE marked |
| Enclosure | Chemically resistant, IP-rated housing |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | Abbe5 |
| Measurement Range | 1.30–1.70 RI, 0–95 % °Brix |
| Resolution | 0.0005 RI, 0.25 % °Brix |
| Operating Temperature | 5–70 °C |
| Temperature Display | Built-in digital sensor, 0.1 °C resolution |
| Light Source | Sodium D-line (589.3 nm) |
| Housing | Chemical-resistant, IP-rated enclosure |
| Compliance | BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE marked |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RFM300 Digital Refractometer |
| Pricing | Available Upon Request |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | Eclipse |
| Scale Options | °Brix (0–15 to 45–80), % ABV (10–135), Water-in-Honey (10–30%), Refractive Index (1.330–1.420), Starch (0–30%), Antifreeze (°C/°F, Ethylene/Propylene Glycol % vol), Battery Acid SG (1.1–1.35), Salinity (0–28% NaCl), Wine Scales (°Oechsle CH/D, Baumé) |
| ATC Available | Yes |
| Sample Volume (Standard) | ~0.1 mL |
| Sample Volume (Micro) | ≤1 µL |
| Calibration | Single-point aqueous standard (e.g., distilled water or sucrose reference solution) |
| Construction | Full metal body with heat-insulating rubber grip |
| Compliance | BS EN ISO 9001:2000, CE, UKAS-accredited manufacturing |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RI1.42 |
| Measurement Range | 1.33–1.42 RI |
| Resolution | 0.0001 RI |
| Accuracy | ±0.0003 RI |
| ATC | Yes |
| IP Rating | IP65 |
| Calibration | Pure water zero-point calibration |
| Prism Design | Shallow-angle prism for residue-free cleaning |
| Compliance | BS EN ISO 9001:2000, UKAS, CE |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Portable Handheld Refractometer |
| Measurement Ranges | Brix (4 selectable ranges), Urine (0–12 g/dL), Salt (0–28%), Alcohol (0–32 °Brix |
| Operating Temperature | +10°C to +40°C |
| Automatic Temperature Compensation (ATC) for Brix | +10°C to +30°C |
| Weight | 0.25 kg |
| Compliance | Designed per ISO 21749:2022 (Refractometric determination of soluble solids), ASTM D1218, USP <781> |
| Brand | SCHMIDT+HAENSCH (S+H) |
|---|---|
| Country of Origin | Germany |
| Model Series | ATR ST / ST plus / ST T plus |
| Refractive Index Range | 1.3320–1.5320 / 1.30000–1.54000 / 1.28000–1.54000 RI |
| Brix Range | 0–95 / 0–100 / 0–100 % |
| Resolution | RI 0.0001 / 0.00002 / 0.00001 |
| Accuracy | RI ±0.0001 / ±0.00005 / ±0.00003 |
| Temperature Control Range | +5 °C to +50 °C |
| Light Source | 589 nm LED |
| Display | 16×16 character LCD |
| Auto Temperature Compensation | Yes |
| Brand | Bellingham + Stanley (B+S) |
|---|---|
| Country of Origin | United Kingdom |
| Model | Brix54 |
| Product Type | Handheld Refractometer |
| Digital Display | Yes |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP65 |
| Measurement Scale | °Brix |
| Range | 0–54 °Brix |
| Resolution | 0.1 °Brix |
| Accuracy | ±0.2 °Brix |
| Calibration | Pure water zero-point calibration |
| Prism Design | Shallow-bottom, easy-clean prism stage |
| Housing | Corrosion-resistant, ergonomic polymer body |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | ATR-L |
| Product Type | In-line Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.33200–1.70000 RI / 0–100% Brix |
| Measurement Accuracy | ±0.00001 RI / ±0.01 Brix |
| Temperature Control Range | 10–80 °C |
| Temperature Accuracy | ±0.03 °C |
| Wavelengths | 400, 450, 490, 525, 589, 660, 700 nm (LED-based) |
| Prism Material | YAG |
| Detection Principle | Critical Angle of Total Internal Reflection (ATR) |
| Sensor | CCD array |
| Compliance | ASTM, ISO, AOAC, DIN, ICUMSA, USP, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | RFM700 |
| Measurement Scale | °Brix (0–95 %°Brix, model-dependent) |
| Resolution | 0.01–0.1 %°Brix |
| Accuracy | ±0.04–±0.1 %°Brix |
| Temperature Compensation | ICUMSA, AG Liquids, or user-defined |
| Light Source | LED at 589 nm, >100,000 hr lifetime |
| Prism Material | Synthetic sapphire |
| Compliance | ASTM D5006, BS EN ISO 9001:2000, CE, UKAS-accredited design |
| Interface | RS232 serial output |
| Enclosure | Chemical-resistant, IP-rated waterproof housing |
| Brand | Bellingham + Stanley |
|---|---|
| Origin | United Kingdom |
| Model | OPTi |
| Application | Wine & Beer Quality Control |
| Calibration | Pure Water Zero Point |
| ATC | Yes (Automatic Temperature Compensation) |
| IP Rating | IP65 |
| Prism Design | Shallow, Cleanable, No-Dead-Zone |
| Scale Options | Dual-Scale (A+B) |
| Compliance | BS EN ISO 9001:2000, UKAS, CE |
| Accuracy | ±0.2–±0.5 (varies by scale) |
| Resolution | 0.1–1 unit (scale-dependent) |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | DSR-λ |
| Wavelengths | 400, 436, 486, 546, 589, 656, 707 nm |
| Refractive Index Range | 1.33200–1.70000 (at 589 nm) |
| Resolution | 0.00001 RI unit & 0.01°C |
| Accuracy | ±0.0001 RI (at 20°C) |
| Temperature Control | Peltier-based |
| Operating Temperature Range | +18°C to +30°C (extended ranges available on request) |
| Light Source | Stable LED array with seven discrete wavelengths |
| Compliance | ASTM standard methods built-in |
| Sample Compatibility | Liquids, solutions, transparent or slightly turbid homogeneous samples |
| Brand | Bellingham + Stanley (B+S) |
|---|---|
| Country of Origin | United Kingdom |
| Model | Saline 28 |
| Scale | Salinity (% NaCl) |
| Measurement Range | 0–28% |
| Resolution | 0.1% |
| Accuracy | ±0.2% |
| Calibration | Pure water zero-point calibration |
| Temperature Compensation | Automatic (ATC) |
| Ingress Protection | IP65 |
| Prism Design | Shallow-base, cleanable prism plate |
| Housing | Corrosion-resistant, ergonomic polymer body |
| Compliance | BS EN ISO 9001:2000, UKAS-accredited manufacturing, CE-marked |