BrandINNOTEG
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelMicroDry-96
PricingAvailable Upon Request
Heating MethodDry Block Heating (Optional Water Bath or Gas-Heated Module)
Temperature RangeRT+10°C to 100°C
Temperature Uniformity±1°C per well position
Temperature Stability±2°C (PID Control)
Sample Capacity192 positions (2 × 96-well plates)
Nitrogen Pressure Range3–100 psi
Gas Consumption0.3–0.4 L/min per nozzle
Needle Descent Speed0.1–10 mm/min (motorized, programmable)
Nozzle Alignment Tolerance±1 mm from well center
Flow Uniformity≤5% deviation across all nozzles
Dimensions (W×D×H)325 × 364 × 596 mm
Safety FeaturesHigh/Low Pressure Alarm, Overheat Protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOrganomation
OriginUSA
ModelN-EVAP
Heating MethodWater Bath
Temperature Control RangeAmbient to 90 °C
Temperature Uniformity±2 °C (6–24 positions), ±0.5 °C (34 & 45 positions)
Sample Capacity6–45 positions
Tube Diameter Compatibility10–29 mm (standard), up to 56 mm (optional)
Gas Flow Rate0–10 L/min (6/12/24), 0–20 L/min (34), 0–30 L/min (45)
Input Gas Pressure30–150 psig
Output Gas Pressure0–30 psig
Nitrogen Consumption~330 mL/min per sample
Heating Power500–1400 W
ConstructionLaboratory-grade stainless steel
Optional ConfigurationsAcid-resistant coating (RT), Dry-Block with aluminum beads (DA), PTFE-coated needles (T), Extended 6-inch needles (6), Pasteur pipette adapter (P), Heater-free configuration (O)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOTEG
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelVelaEvap-DC
QuotationUpon Request
Temperature Stability±1 °C
Sample Capacity24 positions
Nitrogen Flow per Port0.3–0.4 L/min
Needle Material6 mm Stainless Steel Tube + Disposable Pipette Tips
Vertical Alignment Tolerance±1 mm from Center of Tube Well
Temperature Uniformity±1 °C across All Positions
Flow Uniformity≤5% deviation between ports
Compatible Tube Size5–50 mL centrifuge tubes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOrganomation
OriginUSA
Model11801
Heating MethodDry-Block Heating
Temperature Range40–130 °C
Temperature Uniformity±0.5 °C
Sample Capacity96 positions
Gas Flow Rate0–25 LPM
Needle MaterialStainless Steel (2" × 19 gauge)
Compatible Formats96-well plates, 8-tube strips, deep-well plates
ConstructionLaboratory-grade corrosion-resistant materials (optional acid-resistant coating available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOTEG
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelVelaEvap
PricingUpon Request
Heating MethodWater Bath
Temperature RangeRT+10°C to 100°C
Temperature Stability±1°C (PID Control)
Sample Positions24 / 36 / 48