BrandErlab
OriginFrance
ModelXLS483F
Airflow TypeVertical Laminar Flow
Filtration ClassISO Class 5 (equivalent to US Federal Standard 209E Class 100)
Filter Efficiency≥99.995% @ 0.3 µm (EN 1822-1, MPPS test)
Working Height Adjustment Range1014 mm (internal)
External Dimensions (L×W×H)1275 × 790 × 1316–1400 mm
Internal Dimensions (L×W×H)1172 × 692 × 1014 mm
Face Velocity>0.3 m/s
Airflow Volume690 m³/h
Fan Configuration3 × LP44 centrifugal fans
Power Supply100–240 V AC, 50–60 Hz
Total Power Consumption175 W
Sound Pressure Level58 dB(A)
Pre-filter & HEPA Filter MonitoringIntegrated differential pressure gauge
Safety AlarmsAudible and visual fan failure alert
Standard Work SurfaceStainless steel (304 brushed, 2 mm thick, radius-edged)
Optional SurfacesSolid phenolic resin (25 mm, chemical-resistant, spill-containment groove), fixed-height workbench with leveling feet
Optional UpgradeGF4BE+ activated carbon filter module for gaseous contaminant removal
Chemical CompatibilityLiquids, liquid–dust mixtures, dry powders, weighing in controlled environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelS/M321
ConstructionFully Steel Enclosure
ConfigurationDouble-Sided Operation
Airflow Capacity230 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Filtration SystemDual-Layer Molecular Filter Assembly (Class 1 per NFX 15-211)
Power Consumption58 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Pressure Level52 dB(A)
Lighting18 W IP67 Fluorescent Lamp(s), ≥500 lux
Dimensions (S model, mm)L 800 × D 556 × H 1016–1200 (external)
Dimensions (M model, mm)L 800 × D 620 × H 1161–1345 (external)
Operating ApertureElliptical
CertificationCompliant with NFX 15-211:2009 Class 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelBiocap 391
Instrument TypeHorizontal Laminar Flow Clean Bench
Cleanliness ClassISO Class 5 (Class 100) Equivalent
Airflow Velocity≥0.3 m/s
HEPA Filter GradeH14 (99.999% @ 0.3 µm)
Air Volume230 m³/h
Dimensions (W×D×H)External 1010 × 677 × 950 mm, Internal 969 × 523 × 640 mm
Operating Voltage/Frequency100–240 V / 50–60 Hz
Power Consumption58 W
Sound Pressure Level52 dB(A)
Cabinet PressurePositive Pressure Relative to Ambient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelBiocap 712
Instrument TypeHorizontal Laminar Flow Clean Bench
Cleanliness ClassISO Class 5 (Class 100)
Air Velocity> 0.3 m/s
FiltrationH14 HEPA Filter (EN 1822-1:2019)
Airflow Volume460 m³/h
Dimensions (W×D×H)External 1750 × 689 × 950 mm
UV LampTimer-Controlled, 254 nm
Power Supply100–240 V AC, 50–60 Hz
Total Power Consumption105 W
Sound Pressure Level55 dB(A)
Fan Quantity2
ComplianceEN 12464-1, ISO 14644-1, IEC 61000-6-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelXLS483
ConstructionAll-Steel Cabinet
ConfigurationDouble-Faced Operation
Airflow Capacity690 m³/h
Face Velocity Range0.4–0.6 m/s (per AFNOR NF X 15-211:2009)
Filter SystemDual-Stage Molecular Filtration (Class 1 per NFX 15-211)
Power Consumption175 W
Input Voltage100–240 V AC, 50–60 Hz
Internal Control Voltage24 V DC
Noise Level58 dB(A)
Dimensions (L×W×H, mm)1275 × 790 × 1316–1500 (external), 1172 × 692 × 1014 (internal)
LightingIP67-rated 18 W fluorescent lamp(s), ≥500 lux
ComplianceAFNOR NF X 15-211:2009, NFX 15-211 Class 1, SGS & Intertek certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelMinistore 822
Airflow Rate75 m³/h
Noise Level45 dB(A)
External Dimensions (L×D×H)819 × 435 × 911 mm
Internal Dimensions (L×D×H)753 × 322 × 519 mm
ConstructionGalvanized steel with epoxy-polyester corrosion-resistant coating
Optional VersionMinistore 822/PP (polypropylene body, galvanized steel hood with epoxy-polyester coating)
ComplianceAFNOR NF X 15-211 (2016)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM/S321W
Airflow Rate230 m³/h
Surface Air Velocity0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Power Consumption58 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V
Sound Pressure Level52 dB(A)
Filter ConfigurationDual-layer molecular filter cartridge (Class 1 per NF X 15-211)
Dimensions (L×D×H, external)800 × 556 × 1016–1200 mm
Operating ApertureElliptical
IP Rating (Lighting)IP67
Illumination18 W fluorescent lamp, 500 lux
ComplianceNF X 15-211:2009, SGS-certified, TÜV-tested
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM632W
ConstructionFully Steel Enclosure
ConfigurationDouble-Sided Operation
Airflow Capacity460 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Filter SystemDual-layer molecular filtration (Class 1 per NF X 15-211)
Power Input100–240 V AC, 50–60 Hz
Rated Power Consumption125 W
Sound Pressure Level55 dB(A)
Internal Dimensions (L×W×H)1497 × 522 × 866 mm
External Dimensions (L×W×H)1600 × 620 × 1161–1345 mm
LightingIP67-rated fluorescent lamp(s), 18 W, 500 lux
Control InterfaceIntegrated Captair® Flex™ digital control panel with airflow monitoring, timer-based filter saturation alert (60-hr interval), and optional Melecode™ S organic vapor alarm module
Filter MonitoringDedicated sampling port for colorimetric tube-based breakthrough detection
ErgonomicsAngled front panel, elliptical access opening, central splash guard, and curved work surface edge
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelXLS714
ConstructionAll-Steel Enclosure
ConfigurationDouble-Faced Operation
Airflow Capacity920 m³/h
Face Velocity Range0.4–0.6 m/s (per AFNOR NF X 15-211:2009)
Filter SystemDual-Stage Molecular Filtration (Class 1 per NFX 15-211)
Power Consumption235 W
Input Voltage100–240 V AC, 50–60 Hz
Internal Control Voltage24 V DC
Noise Level61 dB(A)
Dimensions (L×W×H)1800 × 790 × 1316–1500 mm (external), 1697 × 692 × 1014 mm (internal)
LightingIP67-rated fluorescent lamp(s), 18 W, ≥500 lux
ComplianceAFNOR NF X 15-211:2009, NFX 15-211 SGS-certified, TÜV/Intertek validation reports available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM391
ConstructionAll-Steel Cabinet
ConfigurationDouble-Sided Operation
Airflow Capacity230 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Filtration SystemDual-Layer Molecular Filter Assembly (Class 1 per NFX 15-211)
Power Consumption58 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Pressure Level52 dB(A)
Dimensions (L×W×H, mm)1000 × 620 × 1161–1345 (external), 897 × 522 × 866 (internal)
LightingIP67-rated fluorescent lamp(s), 18 W, ≥500 lux
Ergonomic FeaturesTilted front panel, elliptical sash opening, curved work surface edge
CertificationCompliant with NFX 15-211:2009 Class 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
Model834
ConstructionPolypropylene (PP) cabinet body with modular molecular filtration system
Filtration ArchitectureMulti-stage, customizable filter modules (acid, base, solvent, aldehyde, amine-specific media)
Safety RedundancyIntegrated safety pre-filter for fail-safe operation upon primary filter saturation
Control SystemMicroprocessor-based panel with fan status monitoring, real-time airflow verification, and optional filter saturation alert (Molecode S sensor module)
ComplianceConforms to French Standard NFX 15-211 for ductless fume containment cabinets
CertificationValidated per SGS and Intertek (formerly ITS) test reports
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM391F
ConstructionDouble-sided stainless steel clean bench
Filter ClassEN 1822-1 H14 (≥99.995% @ 0.3 µm MPPS)
Airflow Velocity>0.3 m/s
Airflow Volume230 m³/h
Noise Level52 dB(A)
Power Supply100–240 V / 50–60 Hz
Total Power Consumption58 W
Dimensions (L×W×H, mm)1000 × 620 × (1161–1246) external
Internal Working Area897 × 522 × 866 mm
Cleanliness ClassISO 14644-1 Class 5 (equivalent to US FED STD 209E Class 100)
ComplianceEU GMP Annex 1 Class A/B environments
Pre-filter & HEPA monitoringIntegrated differential pressure gauge and fan failure alarm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginGermany
ModelXLS483W
ConstructionFully Steel Enclosure
ConfigurationDouble-Faced Operation
Airflow Capacity690 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009 Class 1)
Filtration SystemDual-layer molecular filter columns (3 filter frames total)
Power Input100–240 V AC, 50–60 Hz
Power Consumption175 W
Noise Level58 dB(A)
Illumination18 W IP67 fluorescent lamp(s), ≥500 lux at work surface
Safety CertificationCompliant with NF X 15-211:2009 Class 1
Operating ModesLiquid handling, liquid + particulate, powder weighing, cleanroom-compatible applications
Enclosure Dimensions (L×D×H, mm)External 1275 × 790 × 1316–1500
Voltage Output24 V DC (low-voltage control circuitry)
Current Draw1.75 A
Access OpeningFull-height open-face design
Optional MobilityCastor-mounted trolley kit available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelStoreflex™ 1634
ConstructionGalvanized Steel with Epoxy Coating
External Dimensions (W×D×H)1600 × 510 × 2205–2395 mm
Internal Dimensions (W×D×H)1510 × 450 × 1750 mm
Storage Capacity320 bottles (500 mL each)
Noise Level49 dBA
Adjustable PP Shelves20 layers (tray-type, 3 L capacity per shelf)
Fan Power36 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Current Draw0.36 A
Filter Housing MaterialPolypropylene (PP)
Spill Containment>3 L per shelf
ComplianceDesigned to meet EN 14175-5, NF X 15-211, and OSHA 29 CFR 1910.1200 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM481
ConstructionFully Steel Enclosure
ConfigurationDouble-Sided Operation
Airflow Capacity230 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Filtration ClassClass 1 (dual-layer molecular filter configuration)
Power Consumption85 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Pressure Level52 dB(A)
Dimensions (L×W×H, mm)External 1275 × 620 × 1161–1345
Operating ApertureElliptical
Lighting18 W fluorescent lamp(s), 500 lux, IP67 rated
Filter MonitoringIntegrated saturation timer (0–250 h), optional Melecode™ S organic vapor alarm, and physical sampling port for breakthrough verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelChemtrap V 201
Dimensions (L×W×H)200 × 537 × 605 mm
Sound Level55 dBA
Airflow Capacity75 m³/h
Power Supply220 V / 50 Hz
Power Consumption19 W
Current Draw0.1 A
Telescopic Duct Length1 m (Ø80 mm)
Flange Diameter RangeØ75–110 mm
Filtration StandardNFX 15-211 Class 2 (organic vapors)
Filter Lifetime~12 months (typical, dependent on VOC load and exposure profile)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM391W
ConstructionFully Steel, Double-Sided Operation
Airflow Capacity230 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Filtration SystemDual-layer molecular filter array (Class 1 per NF X 15-211)
Power Consumption58 W
Input Voltage100–240 V AC / 24 V DC internal
Sound Pressure Level52 dB(A)
Dimensions (L×W×H, mm)External 1000 × 620 × 1161–1345
Lighting18 W fluorescent lamp(s), 500 lux, IP67 rated
CertificationsCompliant with NF X 15-211:2009, SGS & Intertek validated performance report
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelBiocap 321
Instrument TypeVertical Laminar Flow Clean Bench
Cleanliness ClassISO Class 5 (Class 100)
Airflow Velocity≥0.3 m/s
Airflow Volume230 m³/h
Filter ClassH14 HEPA (EN 1822-1:2022, ≥99.995% @ 0.1 µm)
UV LampTimer-Controlled, 254 nm
External Dimensions (W×D×H)800 × 657 × 890 mm
Internal Dimensions (W×D×H)767 × 530 × 600 mm
Power Supply100–240 V AC, 50–60 Hz
Total Power Consumption58 W
Sound Pressure Level52 dB(A)
Fan Quantity1
ComplianceEN 14644-1, EN 1822-1, IEC 61000-6-3, IEC 61000-6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM632 F
Airflow TypeVertical Laminar Flow
Filter ClassH14 (EN 1822-1, MPPS ≥ 0.3 µm, 99.995% efficiency)
Cleanroom ClassificationISO Class 5 (EN ISO 14644-1) / US Federal Standard 209E Class 100
Operating Face Velocity> 0.3 m/s
Air Volume Flow460 m³/h
Sound Pressure Level55 dB(A)
Power Supply100–240 V, 50–60 Hz
Total Power Consumption125 W
Dimensions (L × W × H, mm)External 1600 × 620 × 1161–1246
Internal Work Area (L × W × H, mm)1497 × 522 × 866
Fan ConfigurationDual LP44 Fans
Pre-filter & HEPA MonitoringIntegrated differential pressure gauge and audible/visual alarm for fan failure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelXLS392
ConstructionAll-Steel Enclosure
ConfigurationDouble-Faced Operation
Airflow Capacity460 m³/h
Face Velocity Range0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009)
Power Consumption105 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Pressure Level55 dB(A)
Filter ConfigurationDual-Layer Molecular Filtration System (Class 1 per NFX 15-211)
External Dimensions (L×W×H)1000 × 790 × 1316–1500 mm
Internal Work Area (L×W×H)897 × 692 × 1014 mm
LightingIP67-rated fluorescent lamp(s), 18 W, ≥500 lux
CertificationsCompliant with NFX 15-211:2009 Class 1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM321F
Airflow TypeVertical Laminar Flow
Filtration ClassISO Class 5 (equivalent to US Federal Standard 209E Class 100)
Filter Efficiency≥99.995% @ 0.3 µm (EN 1822-1, MPPS method)
HEPA Filter GradeH14
Face Velocity>0.3 m/s
Airflow Volume230 m³/h
Sound Pressure Level52 dB(A)
Power Supply100–240 V, 50–60 Hz
Total Power Consumption58 W
Dimensions (W×D×H, mm)External 800 × 620 × 1161–1246
Internal Work Area (W×D×H, mm)764 × 546 × 866
Pre-filter MonitoringIntegrated differential pressure gauge
Alarm SystemAudible and visual fan failure alert
Standard Work Surface Options2 mm brushed 304 stainless steel or 25 mm solid phenolic resin with chemical-resistant finish and integral spill containment trough
Optional Add-onsFixed-height ergonomic workbench with leveling feet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelXLS633
ConstructionAll-Steel Cabinet
ConfigurationDouble-Sided Operation
Airflow Capacity690 m³/h
Face Velocity Range0.4–0.6 m/s
Power Consumption175 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Level58 dB(A)
Filter ConfigurationDual-Layer Molecular Filtration (Class 1 per NF X 15-211:2009)
Filter Housing Quantity3
External Dimensions (L×W×H)1600 × 790 × 1316–1500 mm
Internal Dimensions (L×W×H)1497 × 692 × 1014 mm
Operating ApertureTrapezoidal
Lighting18 W IP67 Fluorescent Lamp(s), 500 lux
ComplianceNF X 15-211:2009 Class 1, SGS Certified, Intertek Verified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelM632
Airflow Capacity460 m³/h
Face Velocity Range0.4–0.6 m/s (per AFNOR NF X 15-211:2009)
Filter ConfigurationDual-layer molecular filtration system (Class 1 per NFX 15-211)
Power Consumption125 W
Input Voltage100–240 V AC, 50–60 Hz
Internal DC Voltage24 V DC
Sound Pressure Level55 dB(A)
Dimensions (L × W × H, external)1600 × 620 × 1161–1345 mm
Operating ApertureElliptical
Lighting18 W fluorescent lamp(s), 500 lux, IP67 rated
ComplianceAFNOR NF X 15-211:2009, SGS-certified per NFX 15-211 filtration standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandErlab
OriginFrance
ModelShelf812
Dimensions (Internal)738 × 188 × 348 mm
Dimensions (External)821 × 280–310 × 582–792 mm (variant-dependent)
Airflow Rate75 m³/h
Air Changes per Minute25
Sound Level45 dBA
Power Supply220 V / 50 Hz
Power Consumption20 W
Current Draw0.17 A
Filtration StandardCompliant with AFNOR NFX 15-211