- All
- Favorite
- Popular
- Most rated
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS483F |
| Airflow Type | Vertical Laminar Flow |
| Filtration Class | ISO Class 5 (equivalent to US Federal Standard 209E Class 100) |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN 1822-1, MPPS test) |
| Working Height Adjustment Range | 1014 mm (internal) |
| External Dimensions (L×W×H) | 1275 × 790 × 1316–1400 mm |
| Internal Dimensions (L×W×H) | 1172 × 692 × 1014 mm |
| Face Velocity | >0.3 m/s |
| Airflow Volume | 690 m³/h |
| Fan Configuration | 3 × LP44 centrifugal fans |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 175 W |
| Sound Pressure Level | 58 dB(A) |
| Pre-filter & HEPA Filter Monitoring | Integrated differential pressure gauge |
| Safety Alarms | Audible and visual fan failure alert |
| Standard Work Surface | Stainless steel (304 brushed, 2 mm thick, radius-edged) |
| Optional Surfaces | Solid phenolic resin (25 mm, chemical-resistant, spill-containment groove), fixed-height workbench with leveling feet |
| Optional Upgrade | GF4BE+ activated carbon filter module for gaseous contaminant removal |
| Chemical Compatibility | Liquids, liquid–dust mixtures, dry powders, weighing in controlled environments |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | S/M321 |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration System | Dual-Layer Molecular Filter Assembly (Class 1 per NFX 15-211) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 52 dB(A) |
| Lighting | 18 W IP67 Fluorescent Lamp(s), ≥500 lux |
| Dimensions (S model, mm) | L 800 × D 556 × H 1016–1200 (external) |
| Dimensions (M model, mm) | L 800 × D 620 × H 1161–1345 (external) |
| Operating Aperture | Elliptical |
| Certification | Compliant with NFX 15-211:2009 Class 1 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 391 |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) Equivalent |
| Airflow Velocity | ≥0.3 m/s |
| HEPA Filter Grade | H14 (99.999% @ 0.3 µm) |
| Air Volume | 230 m³/h |
| Dimensions (W×D×H) | External 1010 × 677 × 950 mm, Internal 969 × 523 × 640 mm |
| Operating Voltage/Frequency | 100–240 V / 50–60 Hz |
| Power Consumption | 58 W |
| Sound Pressure Level | 52 dB(A) |
| Cabinet Pressure | Positive Pressure Relative to Ambient |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 712 |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) |
| Air Velocity | > 0.3 m/s |
| Filtration | H14 HEPA Filter (EN 1822-1:2019) |
| Airflow Volume | 460 m³/h |
| Dimensions (W×D×H) | External 1750 × 689 × 950 mm |
| UV Lamp | Timer-Controlled, 254 nm |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 105 W |
| Sound Pressure Level | 55 dB(A) |
| Fan Quantity | 2 |
| Compliance | EN 12464-1, ISO 14644-1, IEC 61000-6-3 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS483 |
| Construction | All-Steel Cabinet |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter System | Dual-Stage Molecular Filtration (Class 1 per NFX 15-211) |
| Power Consumption | 175 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal Control Voltage | 24 V DC |
| Noise Level | 58 dB(A) |
| Dimensions (L×W×H, mm) | 1275 × 790 × 1316–1500 (external), 1172 × 692 × 1014 (internal) |
| Lighting | IP67-rated 18 W fluorescent lamp(s), ≥500 lux |
| Compliance | AFNOR NF X 15-211:2009, NFX 15-211 Class 1, SGS & Intertek certified |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Ministore 822 |
| Airflow Rate | 75 m³/h |
| Noise Level | 45 dB(A) |
| External Dimensions (L×D×H) | 819 × 435 × 911 mm |
| Internal Dimensions (L×D×H) | 753 × 322 × 519 mm |
| Construction | Galvanized steel with epoxy-polyester corrosion-resistant coating |
| Optional Version | Ministore 822/PP (polypropylene body, galvanized steel hood with epoxy-polyester coating) |
| Compliance | AFNOR NF X 15-211 (2016) |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M/S321W |
| Airflow Rate | 230 m³/h |
| Surface Air Velocity | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V |
| Sound Pressure Level | 52 dB(A) |
| Filter Configuration | Dual-layer molecular filter cartridge (Class 1 per NF X 15-211) |
| Dimensions (L×D×H, external) | 800 × 556 × 1016–1200 mm |
| Operating Aperture | Elliptical |
| IP Rating (Lighting) | IP67 |
| Illumination | 18 W fluorescent lamp, 500 lux |
| Compliance | NF X 15-211:2009, SGS-certified, TÜV-tested |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M632W |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filter System | Dual-layer molecular filtration (Class 1 per NF X 15-211) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Rated Power Consumption | 125 W |
| Sound Pressure Level | 55 dB(A) |
| Internal Dimensions (L×W×H) | 1497 × 522 × 866 mm |
| External Dimensions (L×W×H) | 1600 × 620 × 1161–1345 mm |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, 500 lux |
| Control Interface | Integrated Captair® Flex™ digital control panel with airflow monitoring, timer-based filter saturation alert (60-hr interval), and optional Melecode™ S organic vapor alarm module |
| Filter Monitoring | Dedicated sampling port for colorimetric tube-based breakthrough detection |
| Ergonomics | Angled front panel, elliptical access opening, central splash guard, and curved work surface edge |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS714 |
| Construction | All-Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 920 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter System | Dual-Stage Molecular Filtration (Class 1 per NFX 15-211) |
| Power Consumption | 235 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal Control Voltage | 24 V DC |
| Noise Level | 61 dB(A) |
| Dimensions (L×W×H) | 1800 × 790 × 1316–1500 mm (external), 1697 × 692 × 1014 mm (internal) |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, ≥500 lux |
| Compliance | AFNOR NF X 15-211:2009, NFX 15-211 SGS-certified, TÜV/Intertek validation reports available |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M391 |
| Construction | All-Steel Cabinet |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration System | Dual-Layer Molecular Filter Assembly (Class 1 per NFX 15-211) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 52 dB(A) |
| Dimensions (L×W×H, mm) | 1000 × 620 × 1161–1345 (external), 897 × 522 × 866 (internal) |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, ≥500 lux |
| Ergonomic Features | Tilted front panel, elliptical sash opening, curved work surface edge |
| Certification | Compliant with NFX 15-211:2009 Class 1 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | 834 |
| Construction | Polypropylene (PP) cabinet body with modular molecular filtration system |
| Filtration Architecture | Multi-stage, customizable filter modules (acid, base, solvent, aldehyde, amine-specific media) |
| Safety Redundancy | Integrated safety pre-filter for fail-safe operation upon primary filter saturation |
| Control System | Microprocessor-based panel with fan status monitoring, real-time airflow verification, and optional filter saturation alert (Molecode S sensor module) |
| Compliance | Conforms to French Standard NFX 15-211 for ductless fume containment cabinets |
| Certification | Validated per SGS and Intertek (formerly ITS) test reports |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M391F |
| Construction | Double-sided stainless steel clean bench |
| Filter Class | EN 1822-1 H14 (≥99.995% @ 0.3 µm MPPS) |
| Airflow Velocity | >0.3 m/s |
| Airflow Volume | 230 m³/h |
| Noise Level | 52 dB(A) |
| Power Supply | 100–240 V / 50–60 Hz |
| Total Power Consumption | 58 W |
| Dimensions (L×W×H, mm) | 1000 × 620 × (1161–1246) external |
| Internal Working Area | 897 × 522 × 866 mm |
| Cleanliness Class | ISO 14644-1 Class 5 (equivalent to US FED STD 209E Class 100) |
| Compliance | EU GMP Annex 1 Class A/B environments |
| Pre-filter & HEPA monitoring | Integrated differential pressure gauge and fan failure alarm |
| Brand | Erlab |
|---|---|
| Origin | Germany |
| Model | XLS483W |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009 Class 1) |
| Filtration System | Dual-layer molecular filter columns (3 filter frames total) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Power Consumption | 175 W |
| Noise Level | 58 dB(A) |
| Illumination | 18 W IP67 fluorescent lamp(s), ≥500 lux at work surface |
| Safety Certification | Compliant with NF X 15-211:2009 Class 1 |
| Operating Modes | Liquid handling, liquid + particulate, powder weighing, cleanroom-compatible applications |
| Enclosure Dimensions (L×D×H, mm) | External 1275 × 790 × 1316–1500 |
| Voltage Output | 24 V DC (low-voltage control circuitry) |
| Current Draw | 1.75 A |
| Access Opening | Full-height open-face design |
| Optional Mobility | Castor-mounted trolley kit available |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Storeflex™ 1634 |
| Construction | Galvanized Steel with Epoxy Coating |
| External Dimensions (W×D×H) | 1600 × 510 × 2205–2395 mm |
| Internal Dimensions (W×D×H) | 1510 × 450 × 1750 mm |
| Storage Capacity | 320 bottles (500 mL each) |
| Noise Level | 49 dBA |
| Adjustable PP Shelves | 20 layers (tray-type, 3 L capacity per shelf) |
| Fan Power | 36 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Current Draw | 0.36 A |
| Filter Housing Material | Polypropylene (PP) |
| Spill Containment | >3 L per shelf |
| Compliance | Designed to meet EN 14175-5, NF X 15-211, and OSHA 29 CFR 1910.1200 requirements |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M481 |
| Construction | Fully Steel Enclosure |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration Class | Class 1 (dual-layer molecular filter configuration) |
| Power Consumption | 85 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 52 dB(A) |
| Dimensions (L×W×H, mm) | External 1275 × 620 × 1161–1345 |
| Operating Aperture | Elliptical |
| Lighting | 18 W fluorescent lamp(s), 500 lux, IP67 rated |
| Filter Monitoring | Integrated saturation timer (0–250 h), optional Melecode™ S organic vapor alarm, and physical sampling port for breakthrough verification |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Chemtrap V 201 |
| Dimensions (L×W×H) | 200 × 537 × 605 mm |
| Sound Level | 55 dBA |
| Airflow Capacity | 75 m³/h |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 19 W |
| Current Draw | 0.1 A |
| Telescopic Duct Length | 1 m (Ø80 mm) |
| Flange Diameter Range | Ø75–110 mm |
| Filtration Standard | NFX 15-211 Class 2 (organic vapors) |
| Filter Lifetime | ~12 months (typical, dependent on VOC load and exposure profile) |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M391W |
| Construction | Fully Steel, Double-Sided Operation |
| Airflow Capacity | 230 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Filtration System | Dual-layer molecular filter array (Class 1 per NF X 15-211) |
| Power Consumption | 58 W |
| Input Voltage | 100–240 V AC / 24 V DC internal |
| Sound Pressure Level | 52 dB(A) |
| Dimensions (L×W×H, mm) | External 1000 × 620 × 1161–1345 |
| Lighting | 18 W fluorescent lamp(s), 500 lux, IP67 rated |
| Certifications | Compliant with NF X 15-211:2009, SGS & Intertek validated performance report |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Biocap 321 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (Class 100) |
| Airflow Velocity | ≥0.3 m/s |
| Airflow Volume | 230 m³/h |
| Filter Class | H14 HEPA (EN 1822-1:2022, ≥99.995% @ 0.1 µm) |
| UV Lamp | Timer-Controlled, 254 nm |
| External Dimensions (W×D×H) | 800 × 657 × 890 mm |
| Internal Dimensions (W×D×H) | 767 × 530 × 600 mm |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Total Power Consumption | 58 W |
| Sound Pressure Level | 52 dB(A) |
| Fan Quantity | 1 |
| Compliance | EN 14644-1, EN 1822-1, IEC 61000-6-3, IEC 61000-6-4 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M632 F |
| Airflow Type | Vertical Laminar Flow |
| Filter Class | H14 (EN 1822-1, MPPS ≥ 0.3 µm, 99.995% efficiency) |
| Cleanroom Classification | ISO Class 5 (EN ISO 14644-1) / US Federal Standard 209E Class 100 |
| Operating Face Velocity | > 0.3 m/s |
| Air Volume Flow | 460 m³/h |
| Sound Pressure Level | 55 dB(A) |
| Power Supply | 100–240 V, 50–60 Hz |
| Total Power Consumption | 125 W |
| Dimensions (L × W × H, mm) | External 1600 × 620 × 1161–1246 |
| Internal Work Area (L × W × H, mm) | 1497 × 522 × 866 |
| Fan Configuration | Dual LP44 Fans |
| Pre-filter & HEPA Monitoring | Integrated differential pressure gauge and audible/visual alarm for fan failure |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS392 |
| Construction | All-Steel Enclosure |
| Configuration | Double-Faced Operation |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (compliant with AFNOR NF X 15-211:2009) |
| Power Consumption | 105 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 55 dB(A) |
| Filter Configuration | Dual-Layer Molecular Filtration System (Class 1 per NFX 15-211) |
| External Dimensions (L×W×H) | 1000 × 790 × 1316–1500 mm |
| Internal Work Area (L×W×H) | 897 × 692 × 1014 mm |
| Lighting | IP67-rated fluorescent lamp(s), 18 W, ≥500 lux |
| Certifications | Compliant with NFX 15-211:2009 Class 1 |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M321F |
| Airflow Type | Vertical Laminar Flow |
| Filtration Class | ISO Class 5 (equivalent to US Federal Standard 209E Class 100) |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN 1822-1, MPPS method) |
| HEPA Filter Grade | H14 |
| Face Velocity | >0.3 m/s |
| Airflow Volume | 230 m³/h |
| Sound Pressure Level | 52 dB(A) |
| Power Supply | 100–240 V, 50–60 Hz |
| Total Power Consumption | 58 W |
| Dimensions (W×D×H, mm) | External 800 × 620 × 1161–1246 |
| Internal Work Area (W×D×H, mm) | 764 × 546 × 866 |
| Pre-filter Monitoring | Integrated differential pressure gauge |
| Alarm System | Audible and visual fan failure alert |
| Standard Work Surface Options | 2 mm brushed 304 stainless steel or 25 mm solid phenolic resin with chemical-resistant finish and integral spill containment trough |
| Optional Add-ons | Fixed-height ergonomic workbench with leveling feet |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | XLS633 |
| Construction | All-Steel Cabinet |
| Configuration | Double-Sided Operation |
| Airflow Capacity | 690 m³/h |
| Face Velocity Range | 0.4–0.6 m/s |
| Power Consumption | 175 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Level | 58 dB(A) |
| Filter Configuration | Dual-Layer Molecular Filtration (Class 1 per NF X 15-211:2009) |
| Filter Housing Quantity | 3 |
| External Dimensions (L×W×H) | 1600 × 790 × 1316–1500 mm |
| Internal Dimensions (L×W×H) | 1497 × 692 × 1014 mm |
| Operating Aperture | Trapezoidal |
| Lighting | 18 W IP67 Fluorescent Lamp(s), 500 lux |
| Compliance | NF X 15-211:2009 Class 1, SGS Certified, Intertek Verified |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | M632 |
| Airflow Capacity | 460 m³/h |
| Face Velocity Range | 0.4–0.6 m/s (per AFNOR NF X 15-211:2009) |
| Filter Configuration | Dual-layer molecular filtration system (Class 1 per NFX 15-211) |
| Power Consumption | 125 W |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Internal DC Voltage | 24 V DC |
| Sound Pressure Level | 55 dB(A) |
| Dimensions (L × W × H, external) | 1600 × 620 × 1161–1345 mm |
| Operating Aperture | Elliptical |
| Lighting | 18 W fluorescent lamp(s), 500 lux, IP67 rated |
| Compliance | AFNOR NF X 15-211:2009, SGS-certified per NFX 15-211 filtration standard |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Shelf812 |
| Dimensions (Internal) | 738 × 188 × 348 mm |
| Dimensions (External) | 821 × 280–310 × 582–792 mm (variant-dependent) |
| Airflow Rate | 75 m³/h |
| Air Changes per Minute | 25 |
| Sound Level | 45 dBA |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 20 W |
| Current Draw | 0.17 A |
| Filtration Standard | Compliant with AFNOR NFX 15-211 |
Show next