- All
- Favorite
- Popular
- Most rated
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Smart |
| Feed Water | Type I purified water (deionized, distilled or RO) |
| Product Water Resistivity | ≥18.2 MΩ·cm @ 25°C |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Flow Rate | Up to 1.5 L/min |
| Feed Pressure Range | 0.1–6 bar |
| Integrated UV | Dual-wavelength (185 nm + 254 nm) |
| Final Filtration | 0.2 µm charged polyethersulfone (cPES) end-filter |
| Conductivity Monitoring | Dual-channel (feed & product) |
| Sanitization Method | Injection-based chemical recirculation sanitization |
| System Footprint | Compact integrated design |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | DNA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient, 30–80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 10 mbar |
| Rotational Speed | 1465 rpm |
| Dimensions (W×D×H) | 360 × 597 × 300 mm |
| Weight | 34 kg |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Cold Trap | Not included |
| Pressure Controller | Not included |
| Operating Modes | Water, Alcohol, Other Solvents |
| Sample Compatibility | Tubes, microcentrifuge tubes, vials, round-bottom flasks, 96-well plates |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Labonova Ultra Pro |
| Feed Water | Type I purified water |
| Product Water Grade | ASTM D1193 Type I / ISO 3696 Class 1 / CLSI EP28-A3c compliant |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Flow Rate | Up to 2 L/min |
| UV Source | Dual-wavelength (185 nm + 254 nm) low-pressure mercury lamp |
| Final Filtration | Preventor 5000 ultrafiltration membrane (3-year service life) |
| Display | 7-inch full-color capacitive touchscreen with multilingual UI (English, German, Chinese) |
| Data Export | SD card interface |
| Acoustic Noise Level | <40 dBA |
| Compliance | Designed for GLP/GMP environments |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | DUO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Sample Capacity | 50 mL (max per rotor position) |
| Temperature Range | Ambient, 30–80 °C (1 °C increments) |
| Vacuum Level | Down to 10 mbar |
| Rotational Speed | 1465 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Operation Modes | Manual Defrost / Auto-Defrost / Continuous Condensation |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvent Profiles |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Labonova Central RO |
| Purification Technology | Single-stage reverse osmosis (RO) |
| Feed Water Conductivity Range | Up to 1,000 µS/cm |
| Product Water Conductivity | <20 µS/cm (at 25 °C, dependent on feed water quality) |
| Salt Rejection Rate | ≥98% |
| Interface | RS232 serial communication port |
| System Architecture | Centralized, modular, closed-loop distribution-capable |
| Compliance | Designed for ISO 3696 Grade 3 and ASTM D1193 Type IV water production |
| Configuration | Customizable with external storage tanks, booster pumps, and recirculation loops |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | HT-3i |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 60 °C |
| Temperature Control Accuracy | ±1 °C within 50 °C |
| Sample Capacity | 0.2 mL to 6 L |
| Condenser | Integrated |
| User Interface | Touchscreen Control Software |
| Safety Features | Anti-bumping (Dri-Pure™), Auto-shutdown, HCl-resistant Construction, Inert Gas Purge Capability |
| Advanced Modes | LyoSpeed™ Fast Freeze-Drying, EXALT™ Controlled Crystallization |
| Design | Front-access Door, Multi-layer Rotor Architecture, Compact Footprint |
| Compatibility | Full Interchangeability with Genevac HT-Series Sample Holders |
| Automation Integration | Lab-automation Ready (e.g., robotic arm interface support) |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | QUATTRO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 2 mbar |
| Rotational Speed | 1130 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Modes | Manual Defrost / Auto Defrost / Continuous Condensation |
| Rotor Configurations | 200 × 1.5 mL tubes, 72 × 15 mL tubes, 36 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvents |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MicroDry-96 |
| Pricing | Available Upon Request |
| Heating Method | Dry Block Heating (Optional Water Bath or Gas-Heated Module) |
| Temperature Range | RT+10°C to 100°C |
| Temperature Uniformity | ±1°C per well position |
| Temperature Stability | ±2°C (PID Control) |
| Sample Capacity | 192 positions (2 × 96-well plates) |
| Nitrogen Pressure Range | 3–100 psi |
| Gas Consumption | 0.3–0.4 L/min per nozzle |
| Needle Descent Speed | 0.1–10 mm/min (motorized, programmable) |
| Nozzle Alignment Tolerance | ±1 mm from well center |
| Flow Uniformity | ≤5% deviation across all nozzles |
| Dimensions (W×D×H) | 325 × 364 × 596 mm |
| Safety Features | High/Low Pressure Alarm, Overheat Protection |
| Brand | Organomation |
|---|---|
| Origin | USA |
| Model | N-EVAP |
| Heating Method | Water Bath |
| Temperature Control Range | Ambient to 90 °C |
| Temperature Uniformity | ±2 °C (6–24 positions), ±0.5 °C (34 & 45 positions) |
| Sample Capacity | 6–45 positions |
| Tube Diameter Compatibility | 10–29 mm (standard), up to 56 mm (optional) |
| Gas Flow Rate | 0–10 L/min (6/12/24), 0–20 L/min (34), 0–30 L/min (45) |
| Input Gas Pressure | 30–150 psig |
| Output Gas Pressure | 0–30 psig |
| Nitrogen Consumption | ~330 mL/min per sample |
| Heating Power | 500–1400 W |
| Construction | Laboratory-grade stainless steel |
| Optional Configurations | Acid-resistant coating (RT), Dry-Block with aluminum beads (DA), PTFE-coated needles (T), Extended 6-inch needles (6), Pasteur pipette adapter (P), Heater-free configuration (O) |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct Pro S |
| Pure Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Conductivity (Pure Water) | 0.1–0.2 µS/cm |
| Resistivity (Ultrapure Water) | 18.2 MΩ·cm @ 25 °C |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Pure Water Flow Rate | 16 L/h |
| Ultrapure Water Flow Rate | 2.0 L/min |
| RO Recovery Rate | >75% |
| UV Options | Dual-wavelength (185/254 nm) UV Lamp |
| TOC Monitoring | Integrated Online TOC Sensor |
| Display | 7″ Full-Color Touchscreen (Multilingual: EN/DE/FR/CN) |
| Installation | Benchtop or Wall-Mountable |
| Distribution | Two Independent Dispensers (Fixed + Extendable Handheld) |
| Internal Recirculation | Automated Flush Cycle |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VelaEvap-DC |
| Quotation | Upon Request |
| Temperature Stability | ±1 °C |
| Sample Capacity | 24 positions |
| Nitrogen Flow per Port | 0.3–0.4 L/min |
| Needle Material | 6 mm Stainless Steel Tube + Disposable Pipette Tips |
| Vertical Alignment Tolerance | ±1 mm from Center of Tube Well |
| Temperature Uniformity | ±1 °C across All Positions |
| Flow Uniformity | ≤5% deviation between ports |
| Compatible Tube Size | 5–50 mL centrifuge tubes |
| Brand | Innoteg |
|---|---|
| Origin | Germany |
| Model | Vap Smart |
| Capacity | 4 L |
| Vacuum Capability | Not Specified (Vacuum System Required Separately) |
| Rotation Speed | 20–280 rpm |
| Heating Bath Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Surface Area | 1500 cm² |
| Motorized Lift Stroke | 140 mm |
| Reversible Rotation | Yes |
| Heating Power | 1300 W |
| Bath Type | Dual-Use (Water or Oil) |
| Safety Modes | 3 Programmable Operating Modes |
| Timer Function | Yes |
| Auto-Lift on Power Failure | Yes |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 Bionic |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 30 °C to 80 °C |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | Rocket Synergy2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +5 °C to 60 °C (±1 °C accuracy) |
| Temperature Control Precision | ±1 °C across 30–80 °C operating band |
| Rotational Speed | 1800 rpm |
| Relative Centrifugal Force (RCF) | 700 × g |
| Maximum Sample Volume per Vessel | 450 mL |
| Standard Capacity | 6 positions (450 mL each) |
| Expandable Capacity | 18 positions with Puck accessory |
| Sample Vessel Options | 60 mL, 250 mL, 400 mL, 450 mL |
| Automated Solvent Addition | Up to 100 L total (via integrated peristaltic dosing module) |
| Ultimate Vacuum | 3 mbar (oil-free PTFE diaphragm pump) |
| Cold Trap | Dual-stage, frost-free, auto-drain capable |
| Real-time Monitoring | Stroboscopic viewing window |
| Programmability | 15 user-storable methods |
| Data Interface | USB for method upload/download and audit log export |
| SampleGenie™ Compatibility | Yes (direct-to-vial concentration & quantitative endpoint control) |
| Dri-Pure® Anti-Bumping Technology | Integrated |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct |
| TOC | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Pure Water Output | 10 L/h (Type III, ISO 3696) |
| Ultrapure Water Output | 1.5 L/min (Type I, ASTM D1193 / ISO 3696 / CLSI A2 / CAP) |
| Integrated Storage Tank | 7 L |
| RO Recovery Rate | >75% |
| UV Wavelengths | 185 nm & 254 nm |
| Final Resistivity | ≥18.2 MΩ·cm at 25 °C |
| Brand | Organomation |
|---|---|
| Origin | USA |
| Model | 11801 |
| Heating Method | Dry-Block Heating |
| Temperature Range | 40–130 °C |
| Temperature Uniformity | ±0.5 °C |
| Sample Capacity | 96 positions |
| Gas Flow Rate | 0–25 LPM |
| Needle Material | Stainless Steel (2" × 19 gauge) |
| Compatible Formats | 96-well plates, 8-tube strips, deep-well plates |
| Construction | Laboratory-grade corrosion-resistant materials (optional acid-resistant coating available) |
| Brand | Think-lab |
|---|---|
| Origin | Germany |
| Model | Direct Pro+ |
| Purified Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Conductivity (Type II, 25°C) | 0.06–0.2 µS/cm |
| Resistivity (Type I, 25°C) | 18.2 MΩ·cm |
| Flow Rate (Type II) | up to 20 L/h |
| Flow Rate (Type I) | up to 2.0 L/min |
| TOC | <1–3 ppb |
| Microbial Count | <0.01 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Nuclease-Free (DNase/RNase/DNA) | Yes |
| Particles (>0.2 µm) | None detectable |
| Integrated Modules | RO + EDI + UV (dual-wavelength 185/254 nm) + UF + TOC Monitor |
| Display | 7-inch color touchscreen (multi-language: English, German, French, Chinese) |
| Dimensions (H×W×D) | 530 × 900 × 320 mm |
| Weight | 46 kg |
| Power Supply | 100–240 V / 50–60 Hz |
| Brand | INNOTEG |
|---|---|
| Origin | Germany |
| Model | Vap Basic |
| Rotational Speed Range | 5–300 rpm |
| Heating Bath Temperature Range | Ambient to 180 °C |
| Condenser Cooling Surface Area | 1500 cm² |
| Bath Capacity | 4 L |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 30–80 °C (±1 °C control accuracy) |
| Sample Volume Capacity | 1.5 mL to 500 mL |
| Maximum Rotor Load per Position | 1.5 kg |
| Centrifugal Force | Up to 500 × g |
| Solvent Boiling Point Limit | Up to 220 °C |
| Condenser Capacity | Unlimited (auto-drain enabled) |
| Refrigerant | Low-GWP hydrofluoroolefin (HFO) blend |
| Vacuum Source | Integrated scroll pump |
| Inert Gas Purge | IGP-compatible (N₂ or Ar) |
| Acid Resistance | HCl, HNO₃ compatible |
| Solvent Compatibility | Ethanol, DCM, EtOAc, ACN, H₂O, TFA, DMF, DMSO, ether, and others |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SmartEvap-E / SmartEvap-G / SmartEvap-Q |
| Instrument Type | Vacuum-Assisted Parallel Nitrogen Evaporator |
| Temperature Control | PID-regulated, ±1 °C accuracy |
| Gas Delivery | Non-submerged tilted nitrogen nozzles with vortex airflow generation |
| Sample Positioning | Independent thermal zones per position |
| Flow Uniformity | ≤5% inter-channel flow deviation |
| Quantitation | Integrated liquid-level sensors per position, auto-stop on target volume |
| Compatible Vessels | 15 mL centrifuge tubes (down to ~0.2 mL), 50/100/200 mL specialized evaporation tubes |
| Compliance | Designed for GLP-compliant workflows |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VelaEvap |
| Pricing | Upon Request |
| Heating Method | Water Bath |
| Temperature Range | RT+10°C to 100°C |
| Temperature Stability | ±1°C (PID Control) |
| Sample Positions | 24 / 36 / 48 |