BrandVELP
OriginItaly
ModelNDA702
Analysis PrincipleDumas Combustion Method
Carrier GasesHelium or Argon (switchable without hardware modification)
Digestion/Combustion Time3–4 min per sample
Repeatability (RSD)< 0.5%
Recovery Rate> 99.5%
Detection Limit0.001 mg N (He), 0.01 mg N (Ar)
Combustion Temperature1030 °C
Power Consumption1400 W
Auto-sampler CapacityUp to 117 positions (4 trays × 30 positions)
Dimensions (W×D×H)655 × 510 × 410 mm
Weight55 kg
Electrical Supply230 V / 50 Hz
Gas Purity Requirement≥99.999% for He/Ar and O₂
Gas Pressure Requirement2 bar for carrier gas and O₂
DetectorCalibrated Thermal Conductivity Detector (TCD), reference-gas-free operation
Sample Mass RangeUp to 1.0 g
Data InterfacesUSB, RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelOXITEST
Instrument TypeAccelerated Oxidation Stability Analyzer
Pressure Range0–8 bar
Temperature RangeAmbient to 110 °C
Sample Volume100 mL per chamber
Power Consumption900 W
Voltage230 V / 50–60 Hz
Dimensions (L×W×H)365 × 190 × 485 mm
Weight16.5 kg
Safety FeaturesIntegrated safety vacuum tube, visual over-temperature alarm, real-time fault indication
ComplianceCE-marked, IEC-compliant, ISO 9001 / ISO 14001 / ISO 45001 (formerly OHSAS 18001) certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelCN802
Analysis PrincipleDumas Combustion Method
Measurement Range0.001–200 mg N (equivalent to ppm–100% N in sample)
Sample Weight200 mg–1 g
Digestion/Combustion Time3–4 min per sample
RepeatabilityRSD < 0.5% (verified with EDTA reference standard)
Detection Limits0.01 mg C, 0.001 mg N
Recovery Rate>99.5%
Power Consumption1400 W
Dimensions (L×W×H)655 × 510 × 410 mm
Carrier Gas OptionsHelium or Argon (dual-gas system, no hardware modification required)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK159
Instrument TypeKjeldahl Nitrogen Determinator
Automation LevelSemi-Automated Kjeldahl System
Compliance StandardsAOAC, ISO 8968, ISO 1871, EPA 350.1, DIN 10492, DIN 10493
Construction MaterialsCorrosion-Resistant Polymer Front Panel, Titanium Condenser, Patented Polymer Anti-Splash Head
Safety FeaturesTube Presence Sensor, Safety Door Interlock, Alkali Reservoir Guard Rod, Waste Tray Level Detection, Condensate Flow Monitoring, Reagent Volume Monitoring, Color-Coded Tubing
Titration MethodPhotometric (Colorimetric) Titration per AOAC Official Method 981.10
Interface OptionsUSB 2.0, RS-232, Optional Ethernet Connectivity
Data ManagementOnboard Storage, GLP-Compliant Audit Trail, Export via USB Drive or PC Connection
Peripheral CompatibilityIntegrated Balance Interface, Thermal Printer Support, External Computer Synchronization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK169
Power Supply230 V / 50–60 Hz
Distillation Time3–4 min
Dispensing Precision±2 µL per step
Sample Capacity24 × 250 mL tubes (Ø42 mm) or 21 × 400 mL tubes (Ø52 mm)
Nitrogen Recovery Rate99.5%
Rated Power2250 W
Dimensions (W×H×D)830 × 1730 × 640 mm
Weight170 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK149
Instrument TypeAutomated Kjeldahl Nitrogen Determinator
Automation LevelFully Automated
Nitrogen Determination Range0.1–200 mg N
Recovery Rate≥99.5% (for N content between 0.1–200 mg)
Power Consumption2100 W
Dimensions (W×H×D)385 × 780 × 416 mm
Touchscreen Display3.5-inch color LCD
Data Storage Capacity50,000 test records
Stored Methods20 pre-programmed SOPs
Repeatability (RSD)≤1%
Detection Limit≥0.1 mg N
Steam Output Control10–100% adjustable
Cooling Water Flow0.5 L/min at 15°C
Alkali/Water/Acid Dispensing Volume0–150 mL / 0–200 mL / 0–100 mL
Distillation Time for 100 mL Water3 minutes
Weight27 kg
Power Supply230 V, 50–60 Hz
ConnectivityRS232, USB, TTL, Ehmet interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK139
Display3.5″ Color Touchscreen
Programmable Methods10 Custom Protocols
NaOH/H₂O AdditionAutomatic (0–150 mL / 0–200 mL)
Steam Output Regulation10–100%
Cooling Water Consumption0.5 L/min at 15°C
Repeatability (RSD)≤1%
Nitrogen Recovery≥99.5% (for 1–200 mg N)
Detection Limit≥0.1 mg N
Distillation Time for 100 mL Water4 min
Power Rating2100 W
Voltage/Frequency230 V, 50–60 Hz
Dimensions (W×H×D)385 × 780 × 416 mm
Weight26 kg
Interface2×USB
Enclosure MaterialCorrosion-Resistant Polymer Housing
CondenserTitanium-Coated
Safety SensorsTube Presence, Safety Door Interlock, Alkali Container Guard Rod, Waste Tray Level, Condensate Flow, Reagent Volume Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
Country of OriginItaly
ModelUDK129
Housing MaterialCorrosion-Resistant Polymer
DisplayLCD
Programmable MethodsUser-Defined Protocols
NaOH AdditionAutomated, 0–100 mL
Cooling Water Consumption0.5 L/min at 15°C, 1 L/min at 30°C
Distillation Time≤5 min for 100 mL water
Repeatability (RSD)≤1%
Nitrogen Recovery Rate≥99.5% (for N content 1–200 mg)
Detection Limit≥0.1 mg N
Power Rating2100 W
Voltage/Frequency230/115 V, 50/60 Hz
Dimensions (W×H×D)385 × 780 × 416 mm
Weight25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelNDA701
Analysis MethodDumas combustion
Automation LevelFully automated
Detection Limit0.003 mg N
Reproducibility (RSD)< 0.5%
Recovery> 99.5%
Combustion Temperature1030 °C
Sample Weight Capacityup to 1 g
Autosampler Capacityup to 116 samples
Carrier GasHelium (99.999% purity, 3 bar)
Oxygen Supply99.999% purity, 3 bar
Auxiliary GasCompressed air or nitrogen (99.6%, oil- and water-free, 4 bar)
Power Consumption1400 W
Dimensions (W×H×D)655 × 510 × 410 mm (655 × 690 × 410 mm with autosampler)
Weight54 kg
InterfacesUSB, RS232
ComplianceAOAC, AACC, ASBC, ISO 14891, OIV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelDKL Series
Instrument TypeKjeldahl Digestion Unit
Max Operating Temperature450 °C
Temperature Accuracy±0.5 °C
Ramp Time to 450 °C22 min
Programmable Steps54
Heating ModuleAnodized Aluminum Block
Digestion Tube CompatibilityDKL8 (250 mL, Ø42 mm), DKL12 (250/400 mL, Ø42 mm), DKL20 (250 mL, Ø42 mm), DKL42 (100 mL, Ø26 mm)
Automation LevelFully Automatic (Digestion + Cooling + End-of-Process Alert)
User InterfaceDetached LCD Display
Unique TechnologyVELP TEMS™ (Time, Energy, Money, Space Optimization)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0