Environmental Monitoring Instruments
Filter
Showing 5941–5970 of 9094 results
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL1025 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry |
| Measurement Range | 0–50,000 mg/L (with automatic high-concentration dilution) |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | 10 min per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1030 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | UV Spectrophotometry (225 nm) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | 1 minute per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | OL1031 |
| Pricing | Upon Request |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1032 |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet (UV) Spectrophotometry |
| Measurement Range | 0–50 mg/L |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Measurement Frequency | Not Applicable |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL1040 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Ultraviolet Spectrophotometry |
| Measurement Range | 0–16 mg/L (with automatic dilution beyond range) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | <6 minutes per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | OL1041 |
| Instrument Type | Laboratory-Based |
| Measurement Principle | UV Absorption Spectrophotometry (225 nm) |
| Measurement Range | 0–16 mg/L (with automatic dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Analysis Time | <6 minutes per sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OL1043 |
| Instrument Category | Laboratory-Based |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–5 mg/L (with automatic dilution beyond range) |
| Detection Limit | 0.0010 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1045 |
| Instrument Type | Portable |
| Measurement Principle | UV Spectrophotometry |
| Measurement Range | 0–60 mg/L (auto-dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Time | <8 min per water sample |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL1045N |
| Instrument Type | Portable |
| Measurement Principle | Ultraviolet Spectrophotometry (UV-Vis) |
| Measurement Range | 0–16 mg/L |
| Analysis Time | <8 min per water sample |
| Compliance | HJ 970–2018 (China), GB 17378.4–2007 (Marine Monitoring) |
| Sample Volume Detection | Non-contact automatic measurement with <2% error |
| Extraction Solvent | n-Hexane |
| Oil Separation Method | Magnesium Silicate Adsorption Column |
| Integrated Functional Modules | Sampling, Liquid–Liquid Extraction, Phase Separation, Reagent Delivery, UV Absorbance Measurement |
| Remote Control | Web-based interface compatible with smartphones and tablets |
| Enclosure Material | High-strength engineering plastic |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OL1046 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Spectrophotometry |
| Measurement Range | 0–5 mg/L |
| Detection Limit | 0.0010 mg/L |
| Accuracy | ±2% |
| Resolution | 0.001 mg/L |
| Analysis Cycle Time | 9 minutes |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OL1050 |
| Detection Principle | Infrared Absorption (FTIR-compatible broadband IR photometry) |
| Instrument Class | Laboratory-Based Fixed-Position Analyzer |
| Primary Application Sector | Petrochemical Industry |
| Compliance Basis | Designed to support EPA Method 27 / ISO 12103-1 alignment for airborne oil aerosol quantification |
| Measurement Range | Configurable via auto-dilution (standard range: 0.1–100 mg/m³, extendable to 500 mg/m³ with intelligent over-range dilution) |
| Sample Introduction | Filter Cartridge (glass fiber or quartz) or Sleeve-Type Sampling Probe |
| Extraction Solvent | Tetrachloroethylene (C₂Cl₄) |
| Extraction Method | High-Efficiency Ultrasonic Assisted Extraction |
| Phase Separation | Automatic Density-Based Liquid-Liquid Separation (C₂Cl₄/H₂O) |
| Calibration Modes | Certified Reference Material (CRM)-based calibration, Multi-Point Standard Curve, Single-Point Rapid Calibration |
| Reagent Handling | Fully Automated Dispensing, Recovery, and Activated Carbon–Filtered Exhaust Management |
| Data Interface | Embedded Touchscreen PC + Remote Web API & Mobile App (iOS/Android) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data logging (user authentication, electronic signature, change history) |
| Brand | Online Instrument |
|---|---|
| Model | OL1056 |
| Origin | Shanghai, China |
| Portability | Portable |
| Application Field | Food Service Industry (Commercial Kitchen Exhaust Monitoring) |
| Compliance Basis | HJ 646–2013, HJ 647–2013, HJ 1077–2019 (Chinese EPA Standards for Oil Fume Emission Monitoring) |
| Sample Handling | Fully Automated Reagent Dispensing, Dual-Stage Ultrasonic Extraction, Cuvette Cleaning, Volumetric Finalization, Photometric Quantification at 530 nm |
| Data Output | Excel, PDF, LIMS-Compatible Export |
| Remote Operation | Web-Based Dashboard & Mobile App Support |
| Enclosure Material | Reinforced Engineering Thermoplastic (IP54 Rated) |
| Brand | Online Instrument |
|---|---|
| Model | OL1061 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Infrared Absorption (C–H Stretching Band at ~2930 cm⁻¹) |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Extraction Solvent | Perchloroethylene (C₂Cl₄) |
| Extraction Ratio | Adjustable from 1:1 to 1:50 (solvent:sample) |
| Sampling Depth | Up to 0.5 m submersible |
| Power Supply | Integrated rechargeable battery (4 h continuous operation) |
| Data Interval | Programmable from 1–999 s |
| Interface | Touchscreen industrial PC |
| Compliance | Designed to support EPA Method 1664A, ISO 9377-2, and GB/T 16488–1996 equivalency |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1071 |
| Instrument Type | Portable |
| Detection Principle | UV Absorption Spectrophotometry (225 nm) with Continuous Flow Liquid-Liquid Extraction |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL1120N |
| Instrument Type | Laboratory-Based |
| Measurement Principle | Infrared Spectrophotometry (ASTM D7066, ISO 9377-2, HJ 637–2018) |
| Sample Capacity | 24-position carousel (expandable) |
| Extraction Solvent | Tetrachloroethylene (C₂Cl₄) |
| Oil Classification | Petroleum Hydrocarbons & Animal/Vegetable Oils |
| Separation Method | Triple-phase separation via extraction tube, aqueous barrier membrane, and phase separation column |
| Calibration Options | Certified reference standards, multi-point calibration curve, single-point rapid calibration |
| Reagent Recovery | Automated solvent–water immiscible phase separation |
| Remote Access | Web-based GUI + mobile-responsive interface with real-time status monitoring and audit-trail-enabled command logging |
| Sealing Mechanism | Adaptive elastic dynamic pressure seal (no rotary lid wear) |
| Fluid Handling | High-precision 3-axis robotic arm + solenoid-driven micro-pumps (MTBF ≥ 4×10⁶ cycles) |
| Mixing | Turbulent vortex injection + active flow agitation |
| Cleaning Protocol | Continuous “live-water” rinse between samples |
| Detection Range | Compliant with HJ 637–2018 quantification limits (0.01–100 mg/L for petroleum hydrocarbons |
| Data Compliance | 21 CFR Part 11–ready electronic records with user-level access control, timestamped audit trail, and GLP/GMP-aligned metadata tagging |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OL1171 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry (225 nm) with Continuous-Flow Liquid-Liquid Extraction |
| Measurement Range | 0–16 mg/L (with automatic on-board dilution for over-range samples) |
| Detection Limit | 0.005 mg/L |
| Accuracy | ±2% of reading |
| Resolution | 0.001 mg/L |
| Measurement Frequency | User-Configurable (1–12 measurements/hour typical) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | OL2010 |
| Instrument Type | Laboratory-Based Water Quality Analyzer |
| Analyte | Anionic Surfactants (e.g., LAS, SDS, AES) |
| Compliance Standards | GB 7494–1987, GB/T 5750.4–2023, GB 17378.4–2007, GB 8538–2023, GB/T 39302–2020 |
| Sample Capacity | 25 / 50 / 55 positions (field-upgradable) |
| Extraction Method | Multi-stage chloroform-based liquid–liquid extraction and back-extraction |
| Recovery Rate | ≥95% |
| Automation Level | Fully Automated (reagent dispensing, extraction, phase separation, sample introduction, calibration, waste handling) |
| Data Interface | LIMS-compatible (ASTM E1467-compliant data export, audit trail ready) |
| Safety System | Closed-loop reagent handling, activated carbon exhaust treatment, automated hazardous waste containment |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2010N |
| Instrument Type | Benchtop |
| Ion Detection Capability | Multi-ion |
| Measurement Range | 0.05–2 mg/L |
| Limit of Detection (LOD) | 0.01 mg/L |
| Response Time | Real-time |
| Measurement Accuracy | ±2% |
| Operating Temperature Range | 5–35 °C |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OL2020N |
| Instrument Type | Laboratory-Grade Volatile Phenol Analyzer |
| Sample Capacity | 10 / 22 / 25 positions (field-upgradable) |
| Automation Level | Fully Automated (distillation, reagent addition, liquid transfer, extraction, spectrophotometric measurement) |
| Calibration | Auto-standard preparation & multi-point calibration curve generation |
| Reagent Management | Real-time monitoring, low-reagent alert, closed-loop waste & fume collection |
| Data Interface | LIMS-compatible, remote monitoring via web browser or mobile application |
| Compliance | Designed per HJ 503–2009 and HJ 998–2018 (China EPA standards) |
| Safety Architecture | Fully enclosed operation with integrated fume absorption system |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | OL2050 |
| Instrument Type | Laboratory-Grade Analyzer |
| Pricing | Upon Request |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2060 |
| Instrument Type | Laboratory Analyzer |
| Measurement Principle | Colorimetric Method (Nesslerization) |
| Measurement Range | 0.1–2.0 mg/L (auto-dilution available beyond range) |
| Accuracy | <2% RSD |
| Detection Limit | 0.025 mg/L per HJ 535–2009 |
| Analysis Time | 10 min (Direct Method), 50 min (Distillation Method) |
| Sample Capacity | 25-position or 50-position carousel |
| Measurement Modes | Direct, Coagulation-Precipitation, Distillation |
| Calibration | Multi-point Standard Curve |
| Remote Monitoring | Web-based & mobile-compatible control and data retrieval |
| Compliance | Fully aligned with HJ 535–2009, GB/T 5750.1–2023, and ISO 7150-1 |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2070 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Pricing | Upon Request |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2080 Fully Automated Hexavalent Chromium Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analyte | Hexavalent Chromium (Cr(VI)) |
| Calibration Curve Linearity | R² ≥ 0.999 |
| Automation Level | Full Walk-Away Automation (Sample Transfer, Reagent Dispensing, Interference Removal, Standard Preparation, Mixing, Dilution, Measurement, Cleaning, Waste Collection, Report Generation) |
| Compliance Context | Designed for compliance with ISO 11087, EPA Method 7196A, and GB/T 5750.6–2023 (Standard Methods for Examination of Drinking Water – Chromium) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2090 Fully Automated Nitrite Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analyte | Nitrite (NO₂⁻) |
| Linearity Coefficient | ≥0.999 |
| Automation Level | Full Workflow Automation (Sample Transfer, Reagent Dispensing, Standard Preparation, Mixing, Dilution, Measurement, Cleaning, Waste Collection, Report Generation) |
| Compliance Context | Designed for compliance with ISO 10304-1, ASTM D3869, and GB/T 5750.5–2023 (Standard Methods for Examination of Drinking Water – Nitrite) |
| Brand | Online Instrument |
|---|---|
| Model | OL2100N |
| Origin | Shanghai, China |
| Type | Fully Automated Spectrophotometric Analyzer for Anionic Surfactants (Methylene Blue Active Substances, MBAS) |
| Compliance | GB 7494–1987, GB/T 5750.4–2023, GB 17378.4–2007, GB 8538–2016, GB/T 39302–2020 |
| Sample Capacity | 54-position autosampler (expandable) |
| Automation Level | Fully Unattended Operation (sampling, reagent addition, liquid–liquid extraction, back-extraction, spectrophotometric measurement, system cleaning, pump tube pressure release) |
| Fluid Handling | Hybrid precision syringe + peristaltic pump delivery |
| Calibration | Auto-standard preparation and multi-point curve generation |
| Reagent Management | Closed-loop waste & vapor containment |
| Remote Access | Web-based interface with mobile compatibility (iOS/Android), voice-assisted troubleshooting support |
| Dimensions | Compact benchtop design |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OL2200N |
| Instrument Type | Laboratory-Based Volatile Phenol Analyzer |
| Sample Capacity | 45 positions (expandable upon customization) |
| Distillation Stations | 8 parallel |
| Automation Level | Fully Automated (XYZ robotic sampling, auto-calibration, auto-distillation, reagent addition, phase transfer, liquid-liquid extraction, spectrophotometric quantification) |
| Standard Preparation | Automated multi-point standard curve generation |
| Waste Handling | Closed-loop exhaust and waste liquid collection system |
| Reagent Monitoring | Real-time level sensing with low-reagent alert |
| Remote Access | Web-enabled instrument control and data retrieval via secure HTTPS interface |
| Compliance Framework | Designed to support ISO 6439, HJ 502–2009 (Chinese EPA method), and ASTM D1783–20 for phenolic compounds in water |
| Brand | Online Instrument |
|---|---|
| Model | OL2500N |
| Origin | Shanghai, China |
| Instrument Type | Laboratory-Based Analyzer |
| Compliance Standards | HJ 484–2009, HJ 745–2015, GB/T 5750.5–2023 |
| Sample Capacity | 36 positions |
| Distillation Stations | 8 |
| Fluid Handling | Precision syringe + peristaltic pump hybrid delivery |
| Temperature Control | Programmable water bath with ±0.5 °C stability |
| Reagent Management | Auto-low-reagent alert, auto-standard preparation (multi-level calibration curves), sealed waste & off-gas collection |
| Data Interface | LIMS-compatible, remote monitoring via web-based dashboard, audit-trail-enabled operation logs |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OL2600N |
| Instrument Type | Laboratory-Based Automated Analyzer |
| Measurement Principle | Colorimetric Method (Nessler Reagent Spectrophotometry per HJ 535–2009 and GB/T 5750.1–2023) |
| Sample Capacity | 45 positions |
| Distillation Stations | 8 |
| Measurement Modes | Direct Method, Coagulation-Precipitation Method, Distillation Method |
| Calibration | Automated Standard Preparation & Multi-Point Calibration Curve Generation |
| Remote Access | Web-based & Mobile-Compatible Monitoring & Data Retrieval |
| System Integration | Compatible with Unmanned Laboratory Platforms (e.g., LIMS, SCADA, IoT Edge Gateways) |
| Compliance | Designed to support GLP-compliant workflows and audit-ready data traceability per ISO/IEC 17025 requirements |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL2700N |
| Instrument Type | Laboratory Benchtop Analyzer |
| Sample Capacity | 45 positions |
| Distillation Stations | 8 |
| Automation Level | Fully Automated (sample transfer, reagent addition, calibration curve generation, mixing, colorimetric reaction timing, final volume adjustment, photometric measurement, post-run cleaning and waste disposal) |
| Data Management | Cloud-synced reporting with remote mobile access |
| Compliance Context | Designed for compliance with ISO 16392:2017 (Water quality — Determination of sulfide — Colorimetric method using methylene blue), EPA Method 376.1, and HJ 1226-2021 (Chinese Environmental Protection Standard for Sulfide in Water) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Model | OL2800N |
| Measurement Principle | Diphenylcarbazide Spectrophotometry (GB 7467–1987, GB/T 5750.6–2023) |
| Automation Level | Fully Automated Sample Handling, Reagent Dispensing, Standard Preparation, Curve Fitting, Dilution, Mixing, Cuvette Conditioning, Measurement, Cleaning & Waste Collection |
| Compliance | Aligned with Chinese National Standards for Drinking Water and Environmental Monitoring |
| Connectivity | Remote Web-Based Control via Mobile/Tablet |
| Data Management | Audit-Trail Enabled Reporting with Timestamped Metadata |
| Sample Throughput | Continuous Unattended Operation with Priority Queueing |
| Detection Range | Adjustable Multi-Range Calibration (Auto-Dilution Supported) |
| Waste Handling | Closed-Loop Waste Recovery System |