Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS100-UMB
Measurement Principle24 GHz Doppler radar-based particle detection
Power SupplyDC 12–36 V (solar-compatible)
Operating Temperature−40 °C to +70 °C
Heating FunctionIntegrated radar dome heater
Communication ProtocolsModbus RTU, SDI-12, CAN, ASCII, MQTT (optional)
IP RatingIP66
MaintenanceNo moving parts, maintenance-free design
ComplianceCE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS500-UMB
Measurement PrinciplesUltrasonic (wind speed & direction), NTC thermistor (temperature), Capacitive polymer (relative humidity), MEMS capacitive (barometric pressure)
Wind Speed Range0–60 m/s
Wind Speed Accuracy±0.3 m/s or ±3% (0–35 m/s)
Wind Direction Range0–359.9°
Wind Direction Accuracy±3°
Temperature Range−50 to +60 °C
Temperature Accuracy±0.2 °C (−20 to +50 °C), ±0.5 °C (outside range)
Relative Humidity Range0–100 %RH
RH Accuracy±2 %RH
Barometric Pressure Range300–1200 hPa
Pressure Accuracy±1.5 hPa
Power Supply24 VDC ±10%, <4 VA (unheated), 10 W max with heater
Output InterfaceRS-485, 2-wire, half-duplex
Operating Temperature−50 to +60 °C
Enclosure MaterialAnodized aluminum
Weight1.3 kg
Dimensions (H × Ø)290 mm × 150 mm
ColorWhite powder-coated finish
ProtocolLufft UMB protocol (binary/ASCII over RS-485)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS502-UMB
Measurement PrinciplesUltrasonic time-of-flight (wind speed/direction), NTC thermistor (air temperature), capacitive hygrometer (relative humidity), MEMS barometric pressure sensor, photodiode-based pyranometer (global solar radiation)
Power Supply12–30 V DC, solar-compatible
Communication ProtocolsModbus RTU/ASCII, SDI-12, CAN bus, UMB-protocol (native), optional MQTT/HTTP via gateway
Environmental RatingIP66
Operating Temperature Range–40 °C to +70 °C
Wind Measurement Range0–75 m/s (0.01 m/s resolution), Direction: 0–360° (0.1° resolution)
Temperature Range–40 to +70 °C (±0.2 °C accuracy)
Relative Humidity Range0–100 %RH (±2 %RH typical)
Pressure Range500–1100 hPa (±0.5 hPa)
Radiation Range0–2000 W/m² (±5 % uncertainty)
Integrated Fan AspirationYes
Heating FunctionYes (ultrasonic transducers)
Data OutputReal-time wind quality index (e.g., signal-to-noise ratio, data validity flags), configurable sampling interval (1 s to 10 min)
External Sensor SupportRain gauge (pulse input), Pt100/Pt1000 temperature probes, analog 4–20 mA inputs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS601-UMB
Measurement ParametersWind Speed, Wind Direction, Air Temperature, Relative Humidity, Atmospheric Pressure, Precipitation
PrincipleUltrasonic Time-of-Flight (Wind), NTC Thermistor (Temperature), Capacitive Polymer Sensor (Humidity), MEMS Capacitive Barometer (Pressure), Tipping-Bucket Rain Gauge (Precipitation)
Power SupplyLow-power design, solar-compatible
EnclosureCompact all-in-one housing with active ventilation fan and heated ultrasonic transducers
OutputWind quality indicator, integrated electronic compass, optional external temperature probe support
Communication ProtocolsModbus RTU/ASCII, SDI-12, CAN bus, ASCII serial, optional MQTT/HTTP for IoT integration
ComplianceIP66 rated enclosure, CE marked, RoHS compliant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS501-UMB
Measurement PrincipleUltrasonic time-of-flight (wind speed & direction), NTC thermistor (temperature), capacitive humidity sensor (relative humidity), MEMS capacitive barometer (atmospheric pressure), thermopile pyranometer (global solar radiation)
Power SupplyDC 12–30 V, solar-compatible
Communication ProtocolsSDI-12, Modbus RTU (RS-485), CAN bus, UMB-ASCII (native), optional MQTT/HTTP via gateway
Wind Measurement Range0–60 m/s (±0.1 m/s @ <5 m/s), 0–360° (±2°)
Temperature Range–40 to +70 °C (±0.2 °C)
Relative Humidity Range0–100 %RH (±2 %RH)
Pressure Range500–1100 hPa (±0.5 hPa)
Radiation Range0–2000 W/m² (±5 %)
Operating Temperature–40 to +70 °C
IP RatingIP66
HeatingIntegrated ultrasonic transducer heating (–40 to +5 °C activation)
Fan-Assisted AspirationYes, continuous low-power fan for radiation and humidity sensor thermal stabilization
Sensor MountingIntegrated, single-mast mounting
Data OutputReal-time analog/digital, quality flags per parameter
ComplianceCE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/-4, WMO Guide to Instruments and Methods of Observation (CIMO) Class II recommended
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
OriginGermany
ModelWS200-UMB
Measurement PrincipleUltrasonic time-of-flight anemometry
Wind Speed Range0–60 m/s
Wind Direction Range0–360°
Power Supply12–24 VDC, solar-compatible
Operating Temperature−40 to +70 °C
IP RatingIP66
Communication ProtocolsSDI-12, RS-232/485, Modbus RTU, CAN bus, MQTT (optional)
Integrated Electronic CompassYes
Heating FunctionIntegrated ultrasonic transducer heating
Output ParametersWind speed (m/s), wind direction (°), wind quality index (WQI), status diagnostics
External Sensor SupportRain gauge, temperature/humidity probe, barometric pressure sensor
ComplianceCE, RoHS, WMO Guide to Instruments and Methods of Observation (CIMO)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLufft
ModelWS300-UMB
Measurement ParametersAir Temperature, Relative Humidity, Atmospheric Pressure, Dew Point Temperature
Sensor PrinciplesNTC Thermistor (Temperature), Capacitive Polymer (Humidity), MEMS Barometric Sensor (Pressure)
Power SupplyLow-power design, compatible with solar power systems
EnclosureCompact, integrated, IP66-rated housing
Fan-Assisted AspirationIntegrated active ventilation fan for radiation-shielded temperature/humidity measurement
Communication InterfacesRS-232, RS-485, SDI-12, Modbus RTU, CAN bus, UMB-ASCII
ExpandabilitySupports external rain gauge, PT100/PT1000 temperature probes, and third-party analog/digital sensors
ComplianceCE, RoHS, WEEE, EN 61326-1 (EMC), EN 61000-6-2/-6-4
Operating Temperature Range–40 °C to +70 °C
Storage Temperature Range–40 °C to +70 °C
Relative Humidity Range0–100 % RH (non-condensing)
Pressure Range500–1100 hPa
Typical Power Consumption<1.5 W (standby), <3.2 W (fan active)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0