Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model1720E
ConfigurationOnline
Measurement Range0.0001–9.9999 NTU and 10.000–99.999 NTU (auto-ranging)
Resolution0.0001 NTU (0–9.9999 NTU)
Operating Temperature0–50°C (single-sensor), 0–40°C (dual-sensor)
Accuracy±2% of reading or ±0.015 NTU (whichever is greater) for 0–10 NTU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
Instrument TypeBenchtop/Laboratory
Measurement Range0.0001–1000 FNU (NTU)
Resolution0.0001–0.9999 / 1.000–9.999 / 10.00–99.99 / 100–1000 FNU (NTU)
Operating Temperature2–40 °C
Accuracy±0.008 FNU + ±1% of reading (0–10 FNU)
Sample Flow Rate1.0–2.0 L/min
Sample Temperature Range0–70 °C
Power Supply220 VAC, 50 Hz, 40 VA
Optical PrincipleSurface Scatter (90° scattered light detection at air–liquid interface)
ComplianceMeets ISO 7027 and EPA Method 180.1 requirements for turbidity measurement
Output InterfacesCompatible with HACH SC100 or SC1000 universal controllers (4–20 mA analog, Modbus RTU, relay alarms)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
ModelAccu4/T53
ConfigurationOnline Turbidimeter
Measurement Range0.000–1.000, 0.00–10.00, 0.0–100.0 NTU
Resolution0.001 NTU
Accuracy±2% of reading
Repeatability<0.1% of full scale
Operating Ambient Temperature−20 to +60 °C
Sample Temperature Range0 to 60 °C
Sample Flow Rate0.19–26.5 L/min
Max Sample Pressure50 psig
Enclosure RatingNEMA 4X (IP65)
Analog OutputsTwo isolated 4–20 mA outputs
Relay OutputsFour SPDT relays
Power Supply100–240 VAC, 50/60 Hz
Light SourceLong-life LED
ComplianceEPA Method 180.2 (GLI Method 2)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
ModelTL23 Series
Measurement Range0–20000 NTU
Resolution0.001 NTU
Operating Temperature0–40 °C
Accuracy±2% (0–1000 NTU), ±5% (1000–4000 NTU), ±10% (4000–10000 NTU)
ComplianceEPA Method 180.1, ISO 7027, DIN EN 27027, DIN 38404, NFT 90-33
Display7-inch color touchscreen
Light SourceTungsten lamp or LED (860 ± 30 nm)
UnitsNTU, FNU, FAU, EBC, Abs, %T, mg/L
Sample Cell95 × 25 mm borosilicate glass vial with rubber-sealed cap
Data Storage2000 records (measurements, calibrations, verifications)
InterfaceDual USB-A ports
Power100–240 V AC, 50/60 Hz, 3.4 A
CertificationsCE, RoHS, CMC
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
ManufacturerHach Company
TypeBenchtop/Laboratory
Measurement RangeTurbidity: 0–10,000 NTU
Color0–500 CU
ResolutionTurbidity: 0.001 NTU
Color1 CU
Operating Environment10–40 °C, ≤90% RH (non-condensing at 25 °C)
AccuracyTurbidity: (1) 0–1,000 NTU: ±0.01 NTU or ±2% of reading
(2) 1,000–4,000 NTU±5% of reading
(3) 4,000–10,000 NTU±10% of reading. Color: (1) 0–30 CU: ±2 CU
(2) 0–500 CU±5 CU
ComplianceEPA Method 180.1
Sample Volume≥20 mL
Measurement UnitsNTU, NEP, EBC, ABS, T%, CU, and user-defined units
Repeatability±1% of reading or ±0.01 NTU
Power Supply230 V, 50/60 Hz
Weight3.43 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Model2100P
Form FactorPortable (Lab-Grade)
Measurement Range0–1000 NTU
Resolution0.01 NTU (at lowest range)
Accuracy±2% of reading
Operating Temperature0–50 °C
Power Supply4 × AA alkaline batteries or optional AC adapter
Weight520 g
ComplianceEPA Method 180.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Model1900C Economical
Product TypePortable
Measurement Range0–1000 NTU
Resolution0.01 NTU
Operating Temperature0–50 °C
Accuracy±1.5% FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelTU5200
Product TypeBenchtop/Laboratory
Measurement RangeEPA: 0–700 NTU, FNU, TE/F, FTU
ISO0–1000 NTU/FNU/TE/F/FTU
Resolution0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
Operating Temperature10–40 °C (50–104 °F), Relative Humidity: 5–95% RH (non-condensing)
Accuracy±2% of reading + 0.01 NTU for 0–40 NTU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Product TypeBenchtop/Laboratory
ModelTL2300
Measurement Range0–4000 NTU
Resolution0.001 NTU
Operating Temperature0–40 °C
Accuracy±2% + 0.01 NTU (0–1000 NTU)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
ModelFT660sc
Installation TypeOnline
Measurement Range0.000–5000 mNTU
Light Source660 nm Laser Diode (35 mW)
Accuracy±2% of reading or ±5 mNTU (whichever is greater) for 0–1000 mNTU
Resolution0.001 mNTU
Repeatability±3.6% at 30 mNTU, ±1.7% at 800 mNTU
Sample Flow Rate100–750 mL/min
Operating Ambient Temperature0–40 °C
Sample Temperature Range0–50 °C
Analog OutputsDual 4–20 mA (configurable across full range)
Alarm OutputsTwo SPDT relays (5 A / 230 VAC)
Standard ComplianceEPA Method 10133
Controller CompatibilityHACH sc100 / sc1000 universal controllers
Integrated De-bubbling SystemPatented in-line air removal
Calibration StandardsHACH-certified 200 mNTU and 800 mNTU formazin equivalents
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
Model2100Q
Product TypePortable
Measurement Range0–1000 NTU
Resolution0.01 NTU (at lowest range)
Operating Temperature0–50 °C
Accuracy±2% of reading plus stray light contribution
Stray Light< 0.02 NTU (FNU)
Measurement PrincipleRatio method—90° scattered light and transmitted light detection
Regulatory ComplianceEPA Method 180.1
Light SourceTungsten lamp
Calibration OptionsSingle-point (0–40 NTU), full-range (0–1000 NTU), or turbidity-to-suspended solids (0–100 mg/L)
Calibration MemoryLast 25 successful calibrations
Data StorageUp to 500 measurements with timestamp, operator ID, sample ID, mode, units, calibration status, and error logs
Signal AveragingUser-selectable On/Off
Reading ModesNormal, Signal Averaging, Fast-Settling Turbidity
RST (Rapid Settling Turbidity) AlgorithmYes
InterfaceUSB + power module (optional) for direct PC transfer without proprietary software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
Model2100N
Form FactorBenchtop/Laboratory
Measurement Range0–4000 NTU
Resolution0.001 NTU
Operating Temperature10–40 °C
Accuracy±2% (0–1000 NTU)
Sample Volume20 mL minimum
Measurement ModesNTU, NEP, EBC
Ratio MeasurementYes
Power Supply230 V, 50/60 Hz
Relative Humidity≤90% RH (non-condensing at 25 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model1900C
Product TypePortable
Measurement Range0–9.99 NTU, 0–99.9 NTU, or 0–1000 NTU (auto-ranging or manual range selection)
Resolution0.01 NTU (at lowest range)
Operating Temperature0–50 °C
Accuracy≤1% (0–1000 NTU)
Repeatability≤1% (0–1000 NTU)
Zero Drift±1.5% F.S.
Stability±1.5% F.S.
Linearity Error1%
Power Supply4 × AA alkaline batteries or optional AC adapter
Weight520 g
ComplianceEPA Method 180.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product TypeOnline Sensor
Measurement Range0.001–4000 NTU
Operating Temperature0–40 °C
Accuracy±1% of reading or ±0.001 NTU, whichever is greater
Optical Wavelength880 nm (near-infrared LED)
Detection PrincipleDual-angle scattered light photometry (90° for turbidity
Self-cleaning CapabilityYes
ComplianceDesigned for continuous operation in municipal and industrial water/wastewater applications per ISO 7027 and EPA Method 180.1 principles