Empowering Scientific Discovery

Hach Company

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginImported
Manufacturer TypeManufacturer
ModelLA-EC20
Measurement ParameterSingle-parameter (Conductivity)
Form FactorBenchtop
Conductivity Range0.00 μS/cm – 199.9 mS/cm
TDS Range0.0 mg/L – 199.9 g/L
Resistivity RangeNot Specified
Salinity RangeNot Specified
Temperature Range0°C – 100°C
Accuracy±0.5 % of Full Scale
Minimum Resolution0.01 μS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelHQd
PriceUpon Request
Measured ParametersMulti-parameter
PortabilityPortable
Conductivity Range0–200 mS/cm
TDS Range0–200 g/L
Resistivity Range0–100 MΩ·cm
Salinity Range0–100 ppt
Temperature Range−20 to 150 °C
Accuracy±0.5% of Full Scale
Minimum Resolution0.001 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer TypeManufacturer
Model3400
Detection ParameterSingle-parameter (Conductivity)
PortabilityPen-style
Application EnvironmentIndustrial process, laboratory, and field monitoring
Conductivity Range0–200,000 µS/cm
TDS Range0–400,000 ppm
Resistivity Range0.001–20 MΩ·cm
Temperature Range−20 to +200 °C
Accuracy±0.01% of reading
Minimum Resolution0.1 µS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
ModelMP Meter
TypePortable Multiparameter Electrochemical Analyzer
Measurement ParameterspH, ORP, Conductivity, TDS, Resistivity, Salinity, Temperature
Power Supply9V Alkaline Battery (≥100 hours / ~5,000 readings)
Display4-digit LCD
Ingress ProtectionIP67 / NEMA 6 (submersible to 1 m)
Operating/Storage Temperature0–55 °C
Dimensions196 × 68 × 64 mm
Weight352 g
Sample VolumespH/ORP: 1.2 mL
Conductivity/TDS/Resistivity5 mL
Housing MaterialVALOX® thermoplastic
Conductivity Range0–9999 µS/cm, 10–200 mS/cm (5 auto-ranging scales)
Conductivity Accuracy±1% of reading
Conductivity Resolution0.01 (≤100 µS/cm), 0.1 (≤1000 µS/cm), 1.0 (≤10 mS/cm), 0.01 (≤100 mS/cm), 0.1 (≤200 mS/cm)
TDS Range0–9999 ppm, 10–200 ppt (5 auto-ranging scales)
TDS Accuracy±1% of reading
TDS Resolution0.01 (≤100 ppm), 0.1 (≤1000 ppm), 1.0 (≤10 ppt), 0.01 (≤100 ppt), 0.1 (≤200 ppt)
Resistivity Range10 kΩ·cm – 30 MΩ·cm
Resistivity Accuracy±1% of reading
Resistivity Resolution0.01 (<100 kΩ·cm), 0.1 (<1000 kΩ·cm), 0.1 (>1 MΩ·cm)
pH Range0–14 pH
pH Accuracy±0.01 pH
pH Resolution0.01 pH
ORP Range±999 mV
ORP Accuracy±1 mV
ORP Resolution1 mV
Temperature Range0–71 °C
Temperature Accuracy±0.1 °C
Temperature Resolution0.1 °C/°F
Automatic Temperature Compensation (ATC)0–71 °C
Adjustable TC Coefficient0.00–9.99 %/°C (referenced to 25 °C)
Predefined TDS Conversion FactorsKCl, 442™, NaCl
Adjustable TDS Conversion Factor0.20–7.99
Calibration IntervalTypically every 2 weeks to 1 month
Calibration MethodSingle-button field calibration with internal electronic reference
Data RetentionNon-volatile memory preserves calibration constants and logged data during battery replacement
Optional ConnectivityUSB-powered MP Base Dock + MP DataLink software (CSV export, timestamped records, automated metadata tagging)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
Manufacturer StatusManufacturer
Form FactorBenchtop
ApplicationIndustrial Online Monitoring
Conductivity Range0–200 mS/cm
Salinity Range0–45 ppt
Accuracy±1% FS
Enclosure RatingIP66
Explosion ProtectionNEPSI Ex ia IIC T4 Ga (GB/T 3836.x-2021 compliant)
Communication ProtocolHART 7
Display3.5″ Graphical LCD with Icon-Based Menu
Housing Material316 Stainless Steel with Corrosion-Resistant Coating
Compensation OptionsTemperature, Linear, Nonlinear (Ultra-Pure Water, Pure Water, Wastewater), and Custom Curves
SecurityPassword-Protected Configuration Access
DiagnosticsReal-time Sensor Health Monitoring & Predictive Alerting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerDKK TOA Corporation
ModelCM31PW-1-1B
PortabilityPortable
Conductivity Range0.05–200 µS/cm
TDS Range0–100 mg/L
Resistivity Range50 Ω·m–182 kΩ·m
Salinity Range0–100 mg/L
Temperature Range0–80 °C
Accuracy±0.5% FS
Minimum Resolution0.001 µS/cm
Electrode Constant0.01 cm⁻¹
Repeatability±0.5% FS (conductivity/resistivity), ±0.2 °C (temperature)
Temperature CompensationManual/Automatic (0–100 °C)
CalibrationElectrode constant calibration + single-point temperature calibration
Data Storage1,000 measurement records
IP RatingIP67
DisplayLCD
OutputAnalog signal or RS-232C
PowerTwo AA alkaline batteries or 100 VAC adapter
Dimensions35 × 78 × 173 mm (H×W×D)
Weight0.28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHach
OriginUSA
Manufacturer TypeManufacturer
Product OriginImported
ModelHQd Benchtop/Portable Analyzer
Detection ParameterspH, ORP, Conductivity, TDS, Resistivity, Salinity, Dissolved Oxygen (LDO), BOD, Sodium, Ammonium, Ammonia, Fluoride, Nitrate, Chloride
PortabilityPortable & Benchtop Configurable
Conductivity Range0.1 µS/cm – 200 mS/cm
TDS Range0–50,000 mg/L
Resistivity Range2.5 Ω·cm – 49 MΩ·cm
Salinity Range0–42 g/kg (ppt)
Temperature Range0–50 °C
pH Accuracy±0.01 pH
pH Resolution0.01 pH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHACH
OriginImported
ManufacturerHACH Company
Model3700E
Detection ParameterSingle-parameter (Conductivity)
PortabilityPen-style
Conductivity Range0–2,000,000 µS/cm
TDS Range0–9,999 ppm
Salinity Range0.0–200%
Temperature Range−10 to +200 °C
Accuracy±0.01% of reading across all ranges
Minimum Resolution0.1 µS/cm
Sensor InterfaceDigital (HACH SC-series compatible)
Cable Assembly6 m sensor cable + 1 m extension cable with digital adapter
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0