- All
- Favorite
- Popular
- Most rated
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Phosphax sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric (Ascorbic Acid Reduction Method) |
| Detection Limit | <0.01 mg/L PO₄–P |
| Range | 0–2.0 mg/L and 0–10.0 mg/L (selectable) |
| Response Time | <15 minutes (typical cycle time) |
| Output | 4–20 mA, Modbus RTU, Ethernet/IP |
| Sample Inlet | 6–10 bar pressure rating |
| Cleaning | Automatic air-pulse and brush-based cleaning system |
| Controller | Integrated digital sc controller (plug-and-play) |
| Optional Pre-treatment | Filterprobe sc suspended solids removal module |
| Compliance | Designed for continuous operation in wastewater treatment environments per ISO 5667-3, ASTM D515-88, and EN ISO 15681-1 |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Phosphax sc LR Low-Range Orthophosphate Online Analyzer |
| Instrument Type | Online Analyzer |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer | Hach Company |
| Product Type | Imported |
| Model | Polymetron 9610sc |
| Instrument Category | Online Analyzer |
| Channel Options | 1, 2, 4, or 6 channels |
| Measurement Principle | Colorimetric Analysis (Silicomolybdate Method) |
| Range | 0.5–5000 µg/L as SiO₂ |
| Accuracy | ±1% or ±1 µg/L (whichever is greater) for 0–500 µg/L |
| Repeatability | ±0.5 µg/L or ±1% (whichever is greater) |
| LOD | 0.5 µg/L |
| Response Time | 9 min at 25°C |
| Reagent Consumption | 2 L per reagent per 90 days |
| Cycle Time | 15 min |
| Operating Temperature | 5–45°C |
| Sample Temp | 5–50°C |
| Sample Pressure | 2–87 psi |
| Flow Rate | 55–300 mL/min |
| Enclosure Rating | NEMA 4X / IP66 |
| Power | 100–240 V AC, 50/60 Hz |
| Output | 4–20 mA |
| Dimensions | 804 × 452 × 360 mm (H×W×D) |
| Weight | 20 kg (empty), 36.3 kg (with reagents) |
| Certifications | CE, KC, C-tick, cETLus (UL 61010-1, NEMA 250, CSA C22.2 No. 61010-1) |
| Compatible Controllers | SC200, SC1000 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Phosphax sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Colorimetry (Vanadomolybdate Yellow Method) |
| Range | 0.05–15.0 mg/L PO₄–P (Range 1) |
| Detection Limit | 0.05 mg/L PO₄–P (Range 1) |
| Installation | In-situ or flow-through configuration |
| Controller Interface | Digital, plug-and-play sc-series controller |
| Optional Pre-treatment | Filterprobe sc |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer | Hach Company |
| Product Type | Imported |
| Model | Polymetron 9611sc |
| Instrument Category | Online Analyzer |
| Measurement Principle | Ascorbic Acid Colorimetry (low range) / Vanadomolybdophosphoric Acid Colorimetry (high range) |
| Wavelength | 880 nm (low range), 480 nm (high range) |
| Range | Low: 4–5,000 µg/L PO₄ |
| High | 200–50,000 µg/L PO₄ |
| Accuracy | ±4 µg/L or ±4% (low), ±500 µg/L or ±5% (high) |
| LOD | 4 µg/L (low), 200 µg/L (high) |
| Repeatability | ±1% (low), ±5% (high) |
| Response Time | 9 min (at 25 °C) |
| Reagent Consumption | 2 L per reagent per 90 days |
| Cycle Interval | 15 min |
| Operating Temp | 5–45 °C |
| Sample Temp | 5–50 °C |
| Sample Flow Rate | 55–300 mL/min |
| Sample Pressure | 2–87 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Power | 100–240 V AC, 50/60 Hz |
| Output | 4–20 mA |
| Dimensions | 804 × 452 × 360 mm (H×W×D) |
| Weight | 20 kg (empty), 36.3 kg (with reagents) |
| Certifications | CE, cETLus, KC, C-tick |
| Compatible Controllers | SC200, SC1000 |
Show next