- All
- Favorite
- Popular
- Most rated
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | MS9000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, Dissolved Oxygen (DO), Electrical Conductivity (EC), Turbidity, Permanganate Index (COD<sub>Mn</sub>), Ammonia Nitrogen (NH<sub>3</sub>-N), Total Phosphorus (TP), Total Nitrogen (TN), Temperature |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HQd Series |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Conductivity, Dissolved Oxygen (LDO), BOD/CBOD (via LBOD electrode), Sodium, Ammonium, Ammonia, Fluoride, Nitrate, Chloride |
| Electrode Types | IntelliCAL™ Standard, Rugged, and Ultra Configurations |
| Compliance | ASTM D888, EPA Method 4500-O, EPA Method 415.3, ISO 5814, USP <643>, GLP/GMP Data Integrity Support (21 CFR Part 11–ready audit trail, user ID, sample ID, electrode serial logging) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | IL500, IL530, IL550 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Oxidation Methods | UV/Persulfate (IL500), High-Temperature Catalytic Oxidation (IL530 & IL550) |
| Detection Method | NDIR for CO₂ |
| Sample Volume | 0.5–20 mL (IL500) |
| Measurement Parameters | TC, TIC, TOC, NPOC, TNb (optional) |
| TOC Range | 2 ppb–10,000 ppm (IL500) |
| Detection Limit | 2 µg/L (IL500) |
| Operating Temperature | 10–35 °C, ≤90% RH |
| Power Supply | 230 V, 50/60 Hz |
| Communication Interface | RS232 |
| Compliance | ISO 8245 |
| Brand | Hach |
|---|---|
| Model | MM374 |
| Measurement Channels | Dual independent channels (Channel 1: pH + EC + °C |
| Channel 2 | pH / mV / ISE + °C) |
| Electrode Support | Dual-channel electrode configuration with dedicated reference electrodes, Pt1000 temperature probes, integrated conductivity cells with automatic temperature compensation (ATC), and built-in magnetic stirrers per channel |
| Compliance | Designed for laboratory-based water quality analysis in accordance with ASTM D1125, ISO 7888, ISO 10523, and USP <791>, <645> |
| Software Interface | RS232 and USB connectivity for data export |
| Brand | Hach |
|---|---|
| Model | sensION+ MM156 |
| Type | Portable / Handheld Multiparameter Water Quality Analyzer |
| Measurement Parameters | pH, Electrical Conductivity, Dissolved Oxygen (DO), Temperature |
| Enclosure Rating | IP67 |
| Probe | Integrated sensION+ 5049 Multiparameter Sensor Cartridge |
| Sensor Replaceability | Individual sensor modules (pH, conductivity, DO) |
| Probe Housing Material | Polycarbonate |
| Probe Dimensions | 40 mm × 170 mm |
| Electrode Configuration | Gel-filled pH electrode, Platinum-coated conductivity cell with integrated 30 kΩ thermistor, Polarographic DO sensor with replaceable membrane |
| Connector Coding | Color-coded (blue = DO, green = conductivity, black = pH) |
| Display | Backlit graphical LCD with icon-based interface |
| Operation | Single-hand ergonomic design |
| Data Handling | Auto-stabilization, on-screen parameter correlation, real-time temperature compensation |
| Accessories Included | Rugged carrying case (doubles as field workstation), calibration/storage kit, spare membranes, buffer solutions, cleaning tools |
| Compliance | Designed for field deployment under ASTM D1129, ISO 7888, ISO 5814, and USP <643> guidelines |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Wavelength Range | 340–900 nm |
| Optical Bandwidth | 5 nm |
| Wavelength Selection | Method-Driven Automatic Selection |
| Wavelength Calibration | Fully Automatic |
| Readout Modes | Transmittance (%T), Absorbance (A), Concentration (mg/L, ppm, etc.) |
| Interface | USB 1.1 |
| Power Supply | AC Input (100–240 V, 47–63 Hz) or Rechargeable Lithium-ion Battery |
| Weight | 4.06 kg (instrument only), 4.38 kg (with battery) |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing) |
| Data Storage Capacity | 500 test records with timestamp, sample ID, operator code, and result metadata |
| Display | Touchscreen LCD with Chinese-language menu support |
| Sample Compatibility | Hach TNTplus™ pre-filled reagent vials with barcode recognition |
| Brand | OTT Hydromet |
|---|---|
| Origin | USA |
| Model | Hydrolab HL4 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Internal Memory | 4 GB |
| Operating Temperature | -5 to 50 °C |
| Max Deployment Depth | 200 m |
| Dimensions (L × Ø) | 77.78 cm × 4.44 cm |
| Weight (typical w/battery) | 2.2 kg |
| Interface Options | RS-232, SDI-12, RS-485 |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SC200 Universal Controller |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH, Conductivity, Turbidity, Dissolved Oxygen (DO), Flow |
| Communication Protocols | MODBUS RTU (RS232/RS485), Profibus DPV1 (optional), HART |
| Display | 240 × 160 pixel graphical LCD with LED backlight |
| Input Options | Dual digital sensor inputs, dual analog (4–20 mA) inputs, or hybrid digital + analog configurations |
| Output | Two independent 4–20 mA outputs (500 Ω load) |
| Enclosure Rating | NEMA 4X / IP66 |
| Operating Temperature | –20 to 60 °C |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz or 24 VDC (–15% / +20%) |
| Weight | 1.70 kg |
| Certifications | CE (EMC: EN 50081-2, Immunity: EN 61000-6-2), UL, ETL |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HACH 5500sc |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Ammonia, Monochloramine, Free Ammonia |
| Range | 0.01–2 ppm as N |
| Accuracy | ±5% or 0.01 ppm (as N) at 5–40 °C |
| Repeatability | ±3% or 0.01 ppm (as N), whichever is greater |
| Detection Limit | 0.01 ppm as N |
| Response Time | <5 minutes |
| Sample Flow Rate | 100–1000 mL/min |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Sample Pressure | 0.17–6.0 bar |
| Sample Temperature | 5–50 °C |
| Power Output | 4 × 0/4–20 mA (600 Ω max load) |
| Communication Options | Modbus RS-485, Profibus DP (with external controller) |
| Enclosure Rating | NEMA 4X / IP56 |
| Dimensions | 804 × 452 × 360 mm |
| Weight | 20.5 kg (empty) |
| Certifications | CE, cETLus, Australian RCM |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | DR/800 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measured Parameters | Multi-Parameter |
| Wavelength Range (DR/890) | 420, 520, 560, 610 nm |
| Wavelength Range (DR/850) | 520, 610 nm |
| Wavelength Range (DR/820) | 520 nm |
| Wavelength Accuracy | ±1 nm |
| Photometric Range | 0–2 A |
| Wavelength Selection | Automatic |
| Readout Modes | % Transmittance, Absorbance, Concentration |
| Data Storage Capacity | 99 measurements |
| Interface | Infrared (IR) via Data Transfer Adapter to RS-232 serial port |
| Power Supply | 4 × AA alkaline batteries |
| Weight | 470 g |
| Operating Environment | 0–50 °C, ≤90% RH (non-condensing) |
| Standard Curves Stored | DR/890 – 90, DR/850 – 50, DR/820 – 20 |
| Reagent Compatibility | Powder pillows, ampoules, pre-filled TNT tubes |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Capability | Multi-Parameter |
| Wavelength Range | 320–1100 nm |
| Preloaded Methods | 240+ Standard & TNTplus Methods |
| Interface | Color Touchscreen Display |
| Connectivity | Dual USB Ports |
| Software Compatibility | Hach DataTrans™, LINK2SC™ |
| Compliance Support | ASTM D1253, ISO 7027, USP <85>, EPA Methods 4500-NO₂⁻, 4500-PO₄³⁻, 4500-NH₃, etc. |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QC8500 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Analyte Scope | Water Quality Parameters (e.g., Nitrate, Nitrite, Phosphate, Ammonia, Silica, Cyanide, Phenol, etc.) |
| Analysis Method | Flow Injection Analysis (FIA) |
| Number of Channels | Up to 8 simultaneous analytical channels per system (2 systems controllable via one PC) |
| Sample Injection Volume | 2–250 µL |
| Heating Module Range | 25–160 °C |
| Sample Introduction Valve | High-precision 6-port injection valve |
| Detection Principle | Photometric (UV-Vis), with 10-mm pathlength flow cell |
| Quantification Method | Peak area integration |
| Accuracy & Repeatability | ±0.5% RSD |
| Sample Throughput | 20–90 determinations per hour per channel |
| System Footprint (4-channel configuration including PC and printer) | 2.72 × 0.74 × 0.58 m |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SL1000/250 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Colorimetric Parameters | Free Chlorine, Total Chlorine, Free Ammonia, Total Ammonia, Monochloramine, Nitrite, Copper, Alkalinity, Phosphate, Dissolved Iron, Hardness, Peracetic Acid |
| Electrochemical Parameters | pH, Conductivity, Dissolved Oxygen (DO), Temperature, Ion-Selective Electrode (ISE) |
| Measurement Capacity | Up to 6 parameters simultaneously |
| Technology | Chemkey® Microfluidic Cartridge-Based System (U.S. Patents #9012234, #9052302, #9180449, #9182353) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | PCII |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | Multiple (Single-Parameter Operation Mode) |
| Wavelength | Model-Dependent |
| Photometric Range | 0–2.5 ABS |
| Power Supply | AAA Alkaline Batteries (4×) |
| Weight | 230 g |
| Operating Environment | 10–50 °C, 0–90% RH (non-condensing) |
| IP Rating | IP67 (submersible up to 0.9 m for 30 min) |
| Data Storage | 10 recent measurements with timestamp |
| Display | Backlit LCD with battery level indicator |
| Calibration | Factory-calibrated against standardized methods (e.g., APHA, ASTM, ISO) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | sensION+ MM378 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Parameters | pH, ORP (mV), ISE, Conductivity, Dissolved Oxygen (DO) |
| Dual-Channel Architecture | Channel 1 (pH/ORP/ISE/Conductivity), Channel 2 (DO) |
| GLP Compliance | Yes |
| Data Storage Capacity | 400 measurement records |
| Temperature Compensation | Automatic (NTC or Pt1000), Electrode Isoelectric Point Detection Supported |
| Software Integration | LabCom PC Software (optional, bidirectional control) |
| Accessories Included | pH electrode, conductivity electrode, polarographic DO probe, magnetic stirrer (dual-control capable), electrode stand, base, beakers, and calibration accessories |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Polymetron 9500 |
| Pricing | Upon Request |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Dissolved Oxygen (DO), Conductivity, pH, ORP, Turbidity, Sodium, Silica, Chlorine (with compatible sensors) |
Show next